Back to Authors

Fletcher, Joel G

0000-0002-8941-5434

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, MN, 55902, United States.

Citations 30

Estimating the Clinical Impact of Photon-Counting-Detector CT in Diagnosing Usual Interstitial Pneumonia
Inoue, Akitoshi , Johnson, Tucker F. , White, Darin , Cox, Christian W. , Hartman, Thomas E. , Thorne, Jamison E. , Shanblatt, Elisabeth R. , Johnson, Matthew P. , Carter, Rickey E. , Lee, Yong S. , Fletcher, Joel G , Carter, Rickey E , Inoue, Akitoshi , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Investigative Radiology | June 15, 2022 | Volume: 57 | Issue: 11 | Pages: 734-741

10.1097/rli.0000000000000888 Get It

Objective The aim of this study was to evaluate the clinical impact of a higher spatial resolution, full field-of-view investigational photon-counting detector computed tomography (PCD-CT) on radiologist confidence in imaging findings and diagnosis of usual interstitial pneumonia (UIP) compared with conventional energy-integrating detector CT (EID-CT). Materials and Methods Patients suspected of interstitial lung disease were scanned on a PCD-CT system after informed consent and a clinically indicated EID-CT. In 2 sessions, 3 thoracic radiologists blinded to clinical history and scanner type evaluated CT images of the right and left lungs separately on EID- or PCD-CT, reviewing each lung once/session, rating confidence in imaging findings of reticulation, traction bronchiectasis, honeycombing, ground-glass opacities (GGOs), mosaic pattern, and lower lobe predominance (100-point scale: 0–33, likely absent; 34–66, indeterminate; 67–100, likely present). Radiologists also rated confidence for the probability of UIP (0–20, normal; 21–40, inconsistent with UIP; 41–60, indeterminate UIP; 61–81; probable UIP; 81–100, definite UIP) and graded image quality. Because a confidence scale of 50 represented completely equivocal findings, magnitude score (the absolute value of confidence scores from 50) was used for analysis (higher scores were more confident). Image noise was measured for each modality. The magnitude score was compared using linear mixed effects regression. The consistency of findings and diagnosis between 2 scanners were evaluated using McNemar test and weighted κ statistics, respectively. Results A total of 30 patients (mean age, 68.8 ± 11.0 years; M:F = 18:12) underwent conventional EID-CT (median CTDIvol, 7.88 mGy) and research PCD-CT (median CTDIvol, 6.49 mGy). The magnitude scores in PCD-CT were significantly higher than EID-CT for imaging findings of reticulation (40.7 vs 38.3; P = 0.023), GGO (34.4 vs 31.7; P = 0.019), and mosaic pattern (38.6 vs 35.9; P = 0.013), but not for other imaging findings (P ≥ 0.130) or confidence in UIP (34.1 vs 22.2; P < 0.059). Magnitude score of probability of UIP in PCD-CT was significantly higher than EID-CT in one reader (26.0 vs 21.5; P = 0.009). Photon-counting detector CT demonstrated a decreased number of indeterminate GGO (17 vs 26), an increased number of unlikely GGO (74 vs 50), and an increased number of likely reticulations (140 vs 130) relative to EID-CT. Interobserver agreements among 3 readers for imaging findings and probability of UIP were similar between PCD-CT and EID-CT (intraclass coefficient: 0.507–0.818 vs 0.601–0.848). Photon-counting detector CT had higher scores in overall image quality (4.84 ± 0.38) than those in EID-CT (4.02 ± 0.40; P < 0.001) despite increased image noise (mean 85.5 vs 36.1 HU). Conclusions Photon-counting detector CT provided better image quality and improved the reader confidence for presence or absence of imaging findings of reticulation, GGO, and mosaic pattern with idiosyncratic improvement in confidence in UIP presence.
CT or MR Enterography to Assess Response During Vedolizumab Therapy for Small Bowel Crohn’s Disease
Kwapisz, Lukasz , Bruining, David H. , Lee, Yong S. , Edwards, Phillip K , Holmes, David R. , Carter, Rickey E. , Siegelman, Jenifer , Fletcher, Joel G. , Inoue, Akitoshi , Fletcher, Joel G , Carter, Rickey E

Crohn's & Colitis 360 | February 1, 2022 | Volume: 4 | Issue: 1 | Pages: No page available

10.1093/crocol/otac003 Get It

Abstract Background To describe response to therapy of small bowel (SB) Crohn’s disease (CD) at CT or MR enterography (CTE/MRE) in patients on vedolizumab. Methods Patients with SB CD who underwent CTE/MRE exams greater than 12 months apart on vedolizumab therapy were included. Length (in cm) and inflammation severity (EMBARK score) of inflamed SB segments were assessed. Changes in inflammation length of 3.4 cm or greater or inflammation severity of 2 EMBARK points or greater was categorized as response or progression, as appropriate, with development of newly inflamed segments, strictures, or penetrating complications also indicating progression. Patients not meeting the criteria for response or progression were categorized as having stable disease. Results Of 36 SB CD patients, the large majority had prior surgery (86%; 31), anti-TNF use (92%; 33), and internal penetrating (78%; 28) disease. Thirty-two patients had paired baseline and follow-up CTE/MRE exams without interval surgery, with clinical response observed in 24/32 (75%). Based on imaging response criteria, 22% (7/32; 95% CI: 9%–40%) had response, 50% (16/32; 95% CI: 32%–68%) were stable, and 28% (9/32; 95% CI: 14%–47%) had disease progression. Fifty-six percent of (18/32; 95% CI: 38%–74%) patients had clinical improvement with response or stable disease by imaging. Patients with stable disease had shorter median baseline lengths of SB inflammation (P = .012). Proportion of patients with colonic inflammation, perianal disease, or penetrating complications did not change. Conclusions Most patients on vedolizumab for over 12 months demonstrated response or stable SB disease when using objective cross-sectional radiologic imaging criteria using CTE/MRE.
Predicting Risk of Surgery in Patients With Small Bowel Crohn’s Disease Strictures Using Computed Tomography and Magnetic Resonance Enterography
Inoue, Akitoshi , Bartlett, David J. , Shahraki, Narges, Sheedy, Shannon P. , Heiken, Jay P. , Voß, Benjamin, Fidler, Jeff L. , Tootooni, M. Samie , Sır, Mustafa Y. , Baker, Mark E. , Rieder, Florian , Deepak, Parakkal , Bruining, David H. , Voss, Benjamin A, Lightner, A L , Deepak, Parakkal , Fletcher, Joel G , Inoue, Akitoshi , Fidler, Jeff L. , Pasupathy, Kalyan S. , Lightner, Amy L. , Fletcher, Joel G.

Inflammatory Bowel Diseases | January 15, 2022 | Volume: 28 | Issue: 11 | Pages: 1677-1686

10.1093/ibd/izab332 Get It

Abstract Background We aimed to determine if patient symptoms and computed tomography enterography (CTE) and magnetic resonance enterography (MRE) imaging findings can be used to predict near-term risk of surgery in patients with small bowel Crohn’s disease (CD). Methods CD patients with small bowel strictures undergoing serial CTE or MRE were retrospectively identified. Strictures were defined by luminal narrowing, bowel wall thickening, and unequivocal proximal small bowel dilation. Harvey-Bradshaw index (HBI) was recorded. Stricture observations and measurements were performed on baseline CTE or MRE and compared to with prior and subsequent scans. Patients were divided into those who underwent surgery within 2 years and those who did not. LASSO (least absolute shrinkage and selection operator) regression models were trained and validated using 5-fold cross-validation. Results Eighty-five patients (43.7 ± 15.3 years of age at baseline scan, majority male [57.6%]) had 137 small bowel strictures. Surgery was performed in 26 patients within 2 years from baseline CTE or MRE. In univariate analysis of patients with prior exams, development of stricture on the baseline exam was associated with near-term surgery (P = .006). A mathematical model using baseline features predicting surgery within 2 years included an HBI of 5 to 7 (odds ratio [OR], 1.7 × 105; P = .057), an HBI of 8 to 16 (OR, 3.1 × 105; P = .054), anastomotic stricture (OR, 0.002; P = .091), bowel wall thickness (OR, 4.7; P = .064), penetrating behavior (OR, 3.1 × 103; P = .096), and newly developed stricture (OR: 7.2 × 107; P = .062). This model demonstrated sensitivity of 67% and specificity of 73% (area under the curve, 0.62). Conclusions CTE or MRE imaging findings in combination with HBI can potentially predict which patients will require surgery within 2 years.
Using MR Enterography and CT Enterography for Routine Crohn’s Surveillance: How We Do It Now, and How We Hope to Do it in the Future
Kwapisz, Lukasz , Bruining, David H. , Fletcher, Joel G. , Fletcher, Joel G

Korean Journal of Radiology | January 3, 2022 | Volume: 23 | Issue: 1 | Pages: 1

10.3348/kjr.2021.0846 Get It

Impact of dual-energy 50-keV virtual monoenergetic images on radiologist confidence in detection of key imaging findings of small hepatocellular carcinomas using multiphase liver CT
Voß, Benjamin, Khandelwal, Ashish , Wells, Michael , Venkatesh, Sudhakar K. , Lee, Yong S. , Johnson, Matthew P. , Fletcher, Joel G. , Voss, Benjamin A, Wells, Michael L, Inoue, Akitoshi , Fletcher, Joel G , Venkatesh, Sudhakar K

Acta Radiologica | November 1, 2021 | Volume: 63 | Issue: 11 | Pages: 1443-1452

10.1177/02841851211052993 Get It

Background Dual-energy virtual monoenergetic images can increase iodine signal, potentially increasing the conspicuity of hepatic masses. Purpose To determine if dual-energy 50-keV virtual monoenergetic images improve visualization of key imaging findings or diagnostic confidence for small (≤2 cm) hepatocellular carcinomas (HCC) at multiphase, contrast-enhanced liver computed tomography (CT). Material and Methods Patients with chronic liver disease underwent multiphase dual-energy CT imaging for HCC, with late arterial and delayed phase dual-energy 50-keV images reconstructed. Two non-reader subspecialized gastrointestinal (GI) radiologists established the reference standard, determining the location and diagnosis of all hepatic lesions using predetermined criteria. Three GI radiologists interpreted mixed kV CT images without or with dual-energy 50-keV images. Radiologists identified potential HCCs and rated their confidence (0–100 scales) in imaging findings of arterial enhancement, enhancing capsule, tumor washout, and LI-RADS 5 (2018) category. Results In total, 45 patients (14 women; mean age = 59.5 ± 10.9 years) with chronic liver disease were included. Of them, 19 patients had 25 HCCs ≤2 cm (mean size = 1.5 ± 0.4 cm). There were 17 LI-RADS 3 and 4 lesions and 19 benign lesions. Reader confidence in imaging findings of arterial enhancement, enhancing capsule, and non-peripheral washout significantly increased with dual-energy images ( P ≤ 0.022). Overall confidence in HCC diagnosis increased significantly with dual-energy 50-keV images (52.4 vs. 68.8; P = 0.001). Dual-energy images demonstrated a slight but significant decrease in overall image quality. Conclusion Radiologist confidence in key imaging features of small HCCs and confidence in imaging diagnosis increases with use of dual-energy 50-keV images at multiphase, contrast-enhanced liver CT.
CT Noise-Reduction Methods for Lower-Dose Scanning: Strengths and Weaknesses of Iterative Reconstruction Algorithms and New Techniques
Mohammadinejad, Payam , Mileto, Achille , Yu, Lifeng , Leng, Shuai , Guimarães, Luís , Missert, A. , Jensen, Corey T. , Gong, Hao , McCollough, Cynthia H. , Fletcher, Joel G. , Guimaraes, Luis S , Missert, Andrew D , Fletcher, Joel G , McCollough, Cynthia H , Leng, Shuai , Mohammadinejad, Payam , Yu, Lifeng

RadioGraphics | September 1, 2021 | Volume: 41 | Issue: 5 | Pages: 1493-1508

10.1148/rg.2021200196 Get It

The utility of a dual-phase, dual-energy CT protocol in patients presenting with overt gastrointestinal bleeding
Mohammadinejad, Payam , Kwapisz, Lukasz , Fidler, Jeff L. , Sheedy, Shannon P. , Heiken, Jay P. , Wells, Michael , Froemming, Adam T. , Hansel, Stephanie L. , Lee, Yong S. , Halaweish, Ahmed F., Bruining, David H. , Wells, Michael L, Hansel, Stephanie L , Inoue, Akitoshi , Fletcher, Joel G , Mohammadinejad, Payam, Fidler, Jeff L. , Khandelwal, Ashish , McCollough, Cynthia H. , Fletcher, Joel G.

Acta Radiologica Open | July 27, 2021 | Volume: 10 | Issue: 7 | Pages: No page available

10.1177/20584601211030658 Get It

Background Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. Purpose To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. Materials and Methods Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). Results 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images ( p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images ( p = 0.006, p = 0.018). Conclusion A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.
Challenges in Diagnosis and Management of Hemobilia
Parvinian, Ahmad , Fletcher, Joel G. , Venkatesh, Sudhakar K. , Fidler, Jeff L. , Khandelwal, Ashish , Storm, Andrew C , Venkatesh, Sudhakar K , Fidler, Jeff L. , Khandelwal, Ashish R , Fletcher, Joel G , Storm, Andrew C.

RadioGraphics | May 3, 2021 | Volume: 41 | Issue: 3 | Pages: 802-813

10.1148/rg.2021200192 Get It

The feasibility of low iodine dynamic CT angiography with test bolus for evaluation of lower extremity peripheral artery disease
Inoue, Akitoshi , Vrtiska, Terri J., Lee, Yong S. , Vasconcelos, Rogerio N., Weber, Nikkole M. , Halaweish, Ahmed F., Duba, Irene , Williamson, Eric E. , Fletcher, Joel G , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Vascular | January 18, 2021 | Volume: 29 | Issue: 6 | Pages: 927-937

10.1177/1708538120986304 Get It

Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.