Back to Authors

McCrady-Spitzer, Shelly

https://orcid.org/0000-0002-9278-1099

Mayo Clinic

Mayo Clinic

Citations 27

Prospective Longitudinal Study Evaluating Comprehensive Metabolic and Life Style Characteristics of Pancreas Transplantation Recipients
Kaur, Ravinder Jeet , Rizvi, Shafaq R., Reid, Corey, McCrady-Spitzer, Shelly , Dean, Patrick G. , Kukla, Aleksandra , Kudva, Yogish C. , Rizvi, Shafaq, Stegall, Mark D.

Journal of the Endocrine Society | May 3, 2021 | Volume: 5 | Issue: Supplement_1 | Pages: A461-A461

10.1210/jendso/bvab048.941 Get It

Abstract Introduction: Pancreas Transplantation (PT) improves quality of life in Type 1 Diabetes (T1D) patients but limited longitudinal data are available regarding comprehensive metabolic assessment and lifestyle. Our objective was to comprehensively assess T1D patients who underwent PT (PTA and SPK) ≥ 1 year prior on two separate visits 1 year apart. Methodology: We studied 12 PT recipients ≥1 year post PT. Two assessments 1 year apart included comprehensive assessment of graft function using standard mixed meal tolerance test (MMTT), Continuous Glucose Monitoring (CGM) for 1 week, body composition using DEXA scan, physical activity using ActiGraph for 1 week and dietary assessment by VIOCARE®. Results: PT recipients (9F) were 55.5± 9.7 years old, 91.7 % Caucasian with 34.9 ± 12.3 years of diabetes, 6.7 ± 5.2 years (range-1.3–17.6 years) after PT. Ten participants underwent Pancreas Transplantation alone and two received Simultaneous Pancreas Kidney transplantation. Visit 1(V1) showed HbA1c 5.5 ± 0.7%, Fructosamine 238.4 ± 25.6 mcmol/L, BMI 31.2 ± 6.7 kg/m2, fasting plasma glucose (FPG) 95.2 ± 19.4mg/dL and C-peptide 2.6 ± 1.0 ng/ml and visit 2 (V2) HbA1c 5.5 ± 0.6%, Fructosamine 244.4 ± 41.3 mcmol/L, BMI 29.9 ± 5.1kg/m2, FPG 95.4 ± 27.7mg/dL, and C-peptide 2.5 ± 0.8 ng/ml (p-value not significant). One week CGM (n=9) showed excellent glucose control at both visits with mean glucose 117.8 ± 7.0 vs.112 ± 6.2 mg/dl and 96.3 ± 3.6 vs. 96.9±2.8 % time in target range (70-180mg/dl). Time >180mg/dl and >250mg/dl were 2.7 ± 3.0 vs. 1.3±1.7 % (p=0.0413) and 0.2 ± 0.6 vs. 0.1 ± 0.1 % respectively. Mild CGM hypoglycemia (<70 mg/dl) was observed during both visits (1.0 ± 1.0 vs. 1.7± 2 %). CV was 21.1 ± 5.5 and 20.1 ± 4.8 %. Eight recipients underwent MMTT and showed excellent response to Boost® with no significant difference between visits with exception of insulin concentrations at 60 mins (increased from V1) and 90 mins (decreased from V1) (p=0.0424 and 0.0235). DEXA (n=10) revealed similar total % mean fat, and fat distribution in arms, legs and trunk. ActiGraph (n=10) showed similar physical activity during both visits with 16761 ± 5176 and 14499 ± 4192 average steps/day respectively. Mean MET score was 1.6 ± 0.4 and 1.6 ± 0.2 indicating light intensity activity during both periods. Total mean sedentary bouts increased over 1 year (49.6 ± 39.1 vs. 60.8 ± 43.7, p=0.0038). Dietary assessment in 11 recipients showed no significant difference in dietary intake with calories intake 1.3± 0.4 vs. 1.2±0.5 daily Harris-Benedict and macronutrient intake with fat of 36.7 ± 4.3 % and 36.5 ± 5.7 %, CHO of 45.7 ± 5.5 % and 45.7 ± 5.5 % and Omega-3 of 0.1 ± 0.1 g and 0.05 ± 0.1 g respectively. Conclusion: PT recipients have excellent glucose control and pancreas graft function 1 or more years after PT when assessed over successive 2 years with suboptimal body composition and dietary intake and above average physical activity.
Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial
Isganaitis, Elvira , Raghinaru, Dan, Ambler-Osborn, Louise, Pinsker, Jordan E. , Buckingham, Bruce A. , Ekhlaspour, Laya , Kudva, Yogish C., Forlenza, Gregory P. , Beck, Roy W., Kollman, Craig, Lum, John W. , Brown, Sue A. , Laffel, Lori M. , Kovatchev, Boris, Anderson, Stacey, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Laffel, Lori, Pinsker, Jordan, Doyle, Francis, Renard, Eric, Reznik, Yves , Lum, John, Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Green, Jennifer , Legault, Laurent , Wysham, Carol , Eggerman, Thomas, Forlenza, Gregory P , Buckingham, Bruce , Wadwa, R Paul , Kudva, Yogish C. , Levy, Carol J. , Kollman, Craig , Kovatchev, Boris , Anderson, Stacey M. , Oliveri, Mary Clancy , Kumari, Kanchan , Messer, Laurel H , Jacobson, Tali, Doyle, Francis J. , Patibandla, Nandan, Laffel, Lori M. , Cobelli, Claudio , Beck, Roy W. , Willi, Steven Matthew

Diabetes Technology & Therapeutics | November 20, 2020 | Volume: 23 | Issue: 5 | Pages: 342-349

10.1089/dia.2020.0572 Get It

Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
O’Malley, Grenye , Messer, Laurel H. , Pinsker, Jordan E. , Forlenza, Gregory P. , Isganaitis, Elvira , Kudva, Yogish C. , Ekhlaspour, Laya , Raghinaru, Dan, Lum, John W. , Brown, Sue A. , Kovatchev, Boris, Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Laffel, Lori M. , E.I., Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, J.E.P., Church, Mei Mei , André, Camille , Piper, Molly, C.J.L., Lam, David W. , G.O., Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Wadwa, R. Paul, Alonso, G. Todd, Slover, Robert H., Jost, Emily , L.H.M., Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce, L.E., Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Paulson, John A., Beck, Jan-Philipp, Passman, Samantha, Campos, Tiffany, Kollman, D.R. Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Reznik, Yves , Arreza-Rubin, Guillermo, Buckingham, Bruce A. , Forlenza, Gregory P , Messer, Laurel H , Buckingham, Bruce , Levy, Carol J. , Pinsker, Jordan E. , Kovatchev, Boris , Kovatchev, Boris, Oliveri, Mary Clancy , E.I., J.E.P., C.J.L., G.O., Wadwa, R Paul , Kumari, Kanchan , Wadwa, R. Paul, L.H.M., L.E., Town, Marissa, Paulson, John A., Patibandla, Nandan, Arreza-Rubin, Guillermo, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Renard, Eric , Cobelli, Claudio , Arreza-Rubin, Guillermo

Diabetes Technology & Therapeutics | November 6, 2020 | Volume: 23 | Issue: 4 | Pages: 245-252

10.1089/dia.2020.0472 Get It

Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Use of the Interoperable Artificial Pancreas System for Type 1 Diabetes Management During Psychological Stress
Pinsker, Jordan E. , McCrady-Spitzer, Shelly , Church, Mei Mei , Kaur, Ravinder Jeet , Pérez, Jimena, Desjardins, Donna, Piper, Molly, Reid, Corey, Kudva, Yogish C. , Dassau, Eyal , Dassau, Eyal , Deshpande, Sunil , Perez, Jimena, Doyle, Francis J.

Journal of Diabetes Science and Technology | August 12, 2020 | Volume: 15 | Issue: 1 | Pages: 184-185

10.1177/1932296820948566 Get It

Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, Sue A. , Beck, Roy W. , Raghinaru, Dan, Buckingham, Bruce A. , Laffel, Lori M. , Kudva, Yogish C. , Pinsker, Jordan E. , Dassau, Eyal , Ambler-Osborn, Louise, Anderson, Stacey M. , Church, Mei Mei , Ekhlaspour, Laya , Forlenza, Gregory P. , Levister, Camilla, Simha, Vinaya , Breton, Marc D. , Kollman, Craig, Lum, John W. , Kovatchev, Boris , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Isganaitis, Elvira , Flint, Emily, Kim, Kenny, Roethke, Lindsay, André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Ogyaadu, Selassie, Lovett, Jessica, Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Pinsker, Jordan E , Dassau, Eyal , Doyle, Francis J , Ekhlaspour, Laya , Forlenza, Gregory P , Breton, Marc D , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Beck, Roy W , Wadwa, R Paul , Levy, Carol J. , Doyle, Francis J. , Kollman, Craig , Oliveri, Mary Clancy , Kumari, Kanchan , Alonso, G. Todd , Messer, Laurel H , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Diabetes Care | May 30, 2020 | Volume: 43 | Issue: 8 | Pages: 1822-1828

10.2337/dc20-0124 Get It

OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P &lt; 0.001). Time &gt;180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P &lt; 0.001) while time &lt;54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, Boris , Anderson, Stacey M. , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Buckingham, Bruce A. , Doyle, Francis J. , Brown, Sue A. , Church, Mei Mei , Dadlani, Vikash, Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Isganaitis, Elvira , Lam, David W. , Lum, John W. , Group, iDCL Study, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Schultz, Alan , Kim, Kenny, Church, Mei Mei, André, Camille , Lam, David W., O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Simha, Vinaya , McCrady-Spitzer, Shelly , Reid, Corey, Jost, Emily , Berget, Cari , Towers, Lindsey, Buckingham, Bruce, Ekhlaspour, Laya, Hsu, Liana, Loebner, Sarah E., Doyle, Francis J., Campos, Tiffany, Passman, Samantha, Murphy, Carlos, Patibandla, Nandan, Kollman, Craig, Pinsker, Jordan E , Doyle, Francis J , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Wadwa, R Paul , Beck, Roy W. , Group, iDCL Study, Oliveri, Mary Clancy , Church, Mei Mei, Lam, David W., Messer, Laurel H , Buckingham, Bruce, Ekhlaspour, Laya, Doyle, Francis J., Kollman, Craig

Diabetes Care | January 15, 2020 | Volume: 43 | Issue: 3 | Pages: 607-615

10.2337/dc19-1310 Get It

OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c &lt;10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P &lt; 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P &lt; 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.
Accuracy of Accelerometers for Measuring Physical Activity and Levels of Sedentary Behavior in Children: A Systematic Review
Lynch, Brian , Kaufman, Tara K. , Rajjo, Tamim , Mohammed, Khaled , Kumar, Seema, Murad, M. Hassan , Gentile, Natalie, Koepp, Gabriel A., McCrady-Spitzer, Shelly , Levine, James A. , Lynch, Brian A , Rajjo, Tamim I, Gentile, Natalie E, Murad, M Hassan

Journal of Primary Care & Community Health | September 11, 2019 | Volume: 10 | Issue: No issue available | Pages: No page available

10.1177/2150132719874252 Get It

Objectives: This systematic review evaluated the accuracy of triaxial and omnidirectional accelerometers for measuring physical activity and sedentary behavior in children. Design: Systematic review of the literature. Methods: We comprehensively searched several databases for studies published from January 1996 through June 2018 that reported diagnostic accuracy measures in children and adolescents (age 3-18 years) and compared accelerometers with energy expenditure using indirect calorimetry. Results: We included 11 studies that enrolled 570 participants. All studies used indirect calorimetry as the reference standard. Across the studies, median sensitivity ranged from 46% to 96% and median specificity ranged from 71% to 96%. Median area under the curve ranged from 69% to 98%. Conclusions: Accuracy measures were greatest when detecting sedentary behavior and lowest when detecting light physical activity. Accuracy was higher when the accelerometer was placed on the hip compared with the wrist. The current evidence suggests that triaxial and omnidirectional accelerometers are accurate in measuring sedentary behavior and physical activity levels in children.
Resting Metabolic Rate, Total Daily Energy Expenditure, and Metabolic Adaptation 6 Months and 24 Months After Bariatric Surgery
Wolfe, Bruce M. , Schoeller, Dale A. , McCrady-Spitzer, Shelly , Thomas, Diana M. , Sorenson, Chad E., Levine, James A. , McCrady-Spitzer, Shelly K , Sorenson, Chad

Obesity | March 31, 2018 | Volume: 26 | Issue: 5 | Pages: 862-868

10.1002/oby.22138 Get It

Objective Little is known about long‐term metabolic (energy expenditure) adaptation after bariatric surgery. Methods Resting metabolic rate under basal conditions (RMR), total daily energy expenditure (TDEE), and body composition were measured in 25 participants in the Longitudinal Assessment of Bariatric Surgery‐2. Results Six months after surgery, BMI (±SD) decreased (47 ± 6 kg/m 2 to 37 ± 5 kg/m 2 ), body fat went from 48% ± 6% to 40% ± 6% fat, and fat‐free mass went from 67 ± 9 kg to 60 ± 9 kg. In absolute terms, RMR and TDEE both decreased significantly (1,730 ± 278 kcal/d vs. 1,430 ± 200 kcal/d and 2,879 ± 544 kcal/d vs. 2,369 ± 304 kcal/d), and the achieved energy balance was −1,293 ± 355 kcal/d. Sixteen of these participants underwent repeated measures at ∼24 months; TDEE decreased 6 months postoperatively (2,957 ± 540 kcal/d to 2,423 ± 324 kcal/d; P = 0.0003), but at ∼24 months, TDEE (2,602 ± 471 kcal/d) was not significantly different compared with month 6. The average negative energy balance from baseline to month 24 was −379 ± 131 kcal/d. Conclusions RMR and TDEE fall precipitously in the first 6 months after bariatric surgery, but these adaptive changes were no longer significant after 2 years.
Twelve-Week 24/7 Ambulatory Artificial Pancreas With Weekly Adaptation of Insulin Delivery Settings: Effect on Hemoglobin A1c and Hypoglycemia
Dassau, Eyal , Pinsker, Jordan E. , Kudva, Yogish C. , Brown, Sue A. , Gondhalekar, Ravi , Man, Chiara Dalla , Patek, Steve, Schiavon, Michele , Dadlani, Vikash, Dasanayake, Isuru , Church, Mei Mei , Carter, Rickey E. , Bevier, Wendy C. , Huyett, Lauren M. , Hughes, Jonathan , Anderson, Stacey M. , Lv, Dayu, Schertz, Elaine, Emory, Emma, McCrady-Spitzer, Shelly , Jean, Tyler, Bradley, Paige K., Hinshaw, Ling , Sanz, Alejandro José Laguna , Basu, Ananda , Kovatchev, Boris , McCrady-Spitzer, Shelly K, Cobelli, Claudio , Doyle, Francis J , Dalla Man, Chiara , Carter, Rickey E , Kovatchev, Boris , Cobelli, Claudio , Doyle, Francis J. , Schiavon, Michele

Diabetes Care | October 14, 2017 | Volume: 40 | Issue: 12 | Pages: 1719-1726

10.2337/dc17-1188 Get It

OBJECTIVE Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. RESEARCH DESIGN AND METHODS Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A1c (HbA1c). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. RESULTS Twenty-nine patients completed the trial. HbA1c, 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (−0.3, 95% CI −0.5 to −0.2, P &lt; 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (−3.1, 95% CI −4.1 to −2.1, P &lt; 0.001) and overnight from 4.1 to 1.1% (−3.1, 95% CI −4.2 to −1.9, P &lt; 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. CONCLUSIONS Use of our novel adaptive AP yielded significant reductions in HbA1c and hypoglycemia.
Addressing obesity in homeless children
Levine, James A. , McCrady-Spitzer, Shelly , Batko, S. M., McCrady-Spitzer, Shelly K, Batko, Samantha

Science | September 22, 2016 | Volume: 353 | Issue: 6306 | Pages: 1374-1375

10.1126/science.aaj1468 Get It