Standardized endpoint definitions for trials of transcatheter left atrial appendage closure: a consensus from the Left Atrial Appendage Academic Research Consortium
Abstract Since its introduction in 2002, left atrial appendage closure (LAAC) has rapidly expanded as an alternative to anticoagulation in patients with atrial fibrillation at high risk of stroke. Harmonized processes for data collection, analysis, and reporting in LAAC trials are essential to enhance research quality and improve clinical practice. The Left Atrial Appendage Academic Research Consortium (LAARC) initiative is an independent collaboration of academic research organizations, cardiology and neurology experts, clinical trialists, and regulatory authorities from the USA, Europe, and Asia. The consortium engaged clinical experts, regulators—including the US Food and Drug Administration (FDA), European Notified Bodies, and Japan’s Pharmaceuticals and Medical Devices Agency (PMDA)—and industry leaders to define standardized study elements and endpoints for LAAC trials. Key considerations included alignment with prior Academic Research Consortium initiatives, procedural and mechanistic insights, and clinical relevance. Consensus definitions were proposed for mortality, stroke, bleeding, and device performance, along with composite endpoints for safety and effectiveness. The proposed LAARC consensus definitions aim to standardize endpoint reporting, improve comparability across studies, and support regulatory and clinical trial applications for this evolving therapy through broad dissemination in the peer-reviewed literature.
Left Atrial Appendage Closure or Anticoagulation for Atrial Fibrillation
One-Year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication With a Subcutaneous Implantable Cardioverter Defibrillator
BACKGROUND: MODULAR antitachycardia pacing (ATP), a multicenter, international trial, assesses a modular cardiac rhythm management system: a subcutaneous implantable cardioverter defibrillator in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia. METHODS: Enrolees had one or more clinical risk factors for ventricular tachycardia and did not require chronic pacing. Complications included prespecified major LP system- and procedure-related complications, and any complication related to the LP, subcutaneous implantable cardioverter defibrillator, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality. RESULTS: The 297 patients enrolled had an ejection fraction of 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias. Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range, 17.9–28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+ subcutaneous implantable cardioverter defibrillator system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4%, and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating ventricular arrhythmia episodes and accelerated ventricular arrhythmias in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years, of which 44/100 patient-years was for shock delivery. CONCLUSIONS: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates, suggesting that the modular cardiac rhythm management is a viable alternative to single-chamber implantable cardioverter defibrillators using low-energy pacing capability without the need for transvenous leads. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/ ; Unique identifier: NCT04798768.
Long‐Term Outcomes Following Left Atrial Appendage Occlusion in Medicare Beneficiaries: Outcomes From the National Cardiovascular Data Registry
Background Percutaneous left atrial appendage occlusion (LAAO) is an alternative to long‐term anticoagulation for preventing ischemic stroke in patients with atrial fibrillation. There are limited long‐term outcomes data for “real‐world” patients undergoing LAAO. Methods We performed a retrospective cohort study using the National Cardiovascular Data Registry LAAO registry from January 1, 2016, through December 31, 2019. We linked LAAO data to inpatient Medicare fee‐for‐service claims data using probabilistic matching to establish a cohort of patients 65 years and older undergoing LAAO with a WATCHMAN device. The primary outcomes were any stroke and all‐cause mortality. Results A total of 34 975 patients with a mean±SD CHA 2 DS 2 ‐VASc (congestive heart failure, hypertension, age ≥75 years, diabetes, previous stroke or transient ischemic attack, vascular disease, age 65 to 74 years, and sex category) score of 4.7±1.4 were included. The median follow‐up was 2.8 years (interquartile range, 2.2–3.7 years). The cumulative incidence of any stroke was 1.57 per 100 person‐years (95% CI, 1.45–1.70), with a 1‐year and 5‐year any stroke estimate of 1.70% (95% CI, 1.57–1.84%) and 5.70% (95% CI, 5.37–6.05%), respectively. The cumulative incidence of ischemic stroke was 1.36 per 100 person‐years (95% CI, 1.25–1.48), with a 1‐year and 5‐year ischemic stroke estimate of 1.42% (95% CI, 1.30–1.54%) and 5.03% (95% CI, 4.71–5.36%), respectively. The cumulative incidence of death was 10.82 per 100 person‐years (95% CI, 10.49–11.13), with a 5‐year mortality estimate of 44.34% (95% CI, 43.35–45.23%). Conclusions Long‐term stroke rates in a large nationally representative cohort of Medicare patients following LAAO were low and durably consistent during long‐term follow‐up despite a high thromboembolic risk. High mortality rates in this elderly population underscore the importance of incorporating patient values and preferences when considering LAAO.
Endovascular Ablation of the Greater Splanchnic Nerve in Heart Failure With Preserved Ejection Fraction
ImportanceGreater splanchnic nerve ablation may improve hemodynamics in patients with heart failure and preserved ejection fraction (HFpEF).ObjectiveTo explore the feasibility and safety of endovascular right-sided splanchnic nerve ablation for volume management (SAVM).Design, Setting, and ParticipantsThis was a phase 2, double-blind, 1:1, sham-controlled, multicenter, randomized clinical trial conducted at 14 centers in the US and 1 center in the Republic of Georgia. Patients with HFpEF, left ventricular ejection fraction of 40% or greater, and invasively measured peak exercise pulmonary capillary wedge pressure (PCWP) of 25 mm Hg or greater were included. Study data were analyzed from May 2023 to June 2024.InterventionSAVM vs sham control procedure.Main Outcomes and MeasuresThe primary efficacy end point was a reduction in legs-up and exercise PCWP at 1 month. The primary safety end point was serious device- or procedure-related adverse events at 1 month. Secondary efficacy end points included HF hospitalizations, changes in exercise function and health status through 12 months, and baseline to 1-month change in resting, legs-up, and 20-W exercise PCWP.ResultsA total of 90 patients (median [range] age, 71 [47-90] years; 58 female [64.4%]) were randomized at 15 centers (44 SAVM vs 46 sham). There were no differences in adverse events between groups. The primary efficacy end point did not differ between SAVM or sham (mean between-group difference in PCWP, −0.03 mm Hg; 95% CI, −2.5 to 2.5 mm Hg; P = .95). There were also no differences in the secondary efficacy end points. There was no difference in the primary safety end point between the treatment (6.8% [3 of 44]) and sham (2.2% [1 of 46]) groups (difference, 4.6%; 95% CI, −6.1% to 15.4%; P = .36). There was no difference in the incidence of orthostatic hypotension between the treatment (11.4% [5 of 44]) and sham (6.5% [3 of 46]) groups (difference, 4.9%; 95% CI, −9.2% to 18.8%; P = .48).Conclusions and RelevanceResults show that SAVM was safe and technically feasible, but it did not reduce exercise PCWP at 1 month or improve clinical outcomes at 12 months in a broad population of patients with HFpEF.Trial RegistrationClinicalTrials.gov Identifier: NCT04592445
A Modular Communicative Leadless Pacing–Defibrillator System
Introduction: Left atrial appendage closure (LAAC) device for stroke prevention is a safe and effective alternative to oral anticoagulation (OAC) in patients with atrial fibrillation (AF). The safety of performing LAAC on uninterrupted warfarin (UW) compared to interrupted warfarin (IW) is currently unknown. Hypothesis: Complication rates of performing LAAC on UW vs. IW will be similar. Methods: We reviewed the data from the second half of PROTECT-AF trial, PREVAIL trial, CAP and CAP2 registries. Patients were categorized to the UW group if INR on the day of the procedure was ≥2 and to the IW group if INR was <2. Procedural complications within 7 days of LAAC were reviewed. An association between complications and AC strategy was analyzed. Results: Data from 1580 patients were reviewed and 294 patients (18.6%) received LAAC on UW. The UW group had a mean INR of 2.4±0.4 and IW group had a mean INR of 1.3±0.3. There were several differences in baseline characteristics: lower BMI in the UW group (28.6±5.3 vs 29.5±6.0, p=0.01), fewer patients with hypertension in the UW group (87.1% vs 91.1%, p=0.04), lower HAS-BLED score in the UW group (2.0±1.0 vs 2.1±1.0, p<0.01), and more patients with persistent AF in the UW group (37.1% vs 26.4%, p<0.01). Overall, there were no significant differences in total or individual complication rates between the two groups (UW 5.1% vs IW 6.1%, p=0.59). Although not statistically significant, lower event rates were noted in the UW group for the following: stroke (0% vs 0.3%, p>0.99), pericardial effusion requiring intervention (1.7% vs 1.8%, p>0.99), pseudoaneurysm (0% vs 0.4%, p=0.59), hematoma (0% vs 0.2%, p>0.99), and device embolism (0% vs 0.2%, p=1.0). The UW group had statistically insignificant higher events rates of AV fistula (0.3% vs 0%, p=0.19) and major bleeding requiring transfusion (1% vs 0.5%, p=0.38). In addition, there was no significant difference in periprocedural ischemic stroke (0% vs 0.3%, p>0.99). Conclusion: In this retrospective analysis, no significant difference was observed in procedural complication rates when performing LAAC on UW vs. IW. These results suggest that LAAC can be safely performed without interruption of OAC.
Cost-effectiveness of left atrial appendage closure with Watchman for non-valvular atrial fibrillation patients in Japan
Background : Modulation of the cardiac autonomic nervous system (ANS) is a promising adjuvant therapy in the treatment of atrial fibrillation (AF). In pre-clinical models, pulsed field (PF) energy has the advantage of selectively ablating the epicardial ganglionated plexi (GP) that govern the ANS. Objective: This study aims to demonstrate the feasibility and safety of epicardial ablation of the GPs with PF during cardiac surgery with a primary efficacy outcome of prolongation of the atrial effective refractory period (AERP). Methods : In a single-arm, prospective analysis, patients with or without a history of AF underwent epicardial GP ablation with PF during coronary artery bypass grafting (CABG). AERP was determined immediately pre- and post- GP ablation to assess cardiac ANS function. Holter monitors were performed to determine rhythm status and Heart Rate Variability (HRV) at baseline and at 1 month post-procedure. Conclusions : This study demonstrates the safety and feasibility of epicardial ablation of the GP using PF to modulate the ANS during cardiac surgery. Large, randomized analyses are necessary to determine whether epicardial PF ablation can offer a meaningful impact on the cardiac ANS and reduce AF. Results : Of 24 patients, 23 (96%) received the full ablation protocol. No device-related adverse effects were noted. GP ablation resulted in a 20.7% ± 19.9% extension in AERP (P < 0.001). Post-operative AF was observed in 7 (29%) patients. Holter monitoring demonstrated an increase in mean heart rate (74.0±8.7 vs 80.6±12.3, P=0.01). There were no significant changes in HRV. There were no study-related complications.
Research Opportunities in Stroke Prevention for Atrial Fibrillation: A Report From a National Heart, Lung, and Blood Institute Virtual Workshop
Atrial fibrillation (AF) is one of the strongest risk factors for ischemic stroke, which is a leading cause of disability and death. Given the aging population, increasing prevalence of AF risk factors, and improved survival in those with cardiovascular disease, the number of individuals affected by AF will continue increasing over time. While multiple proven stroke prevention therapies exist, important questions remain about the optimal approach to stroke prevention at the population and individual patient levels. Our report summarizes the National Heart, Lung, and Blood Institute virtual workshop focused on identifying key research opportunities related to stroke prevention in AF. The workshop reviewed major knowledge gaps and identified targeted research opportunities to advance stroke prevention in AF in the following areas: (1) improving risk stratification tools for stroke and intracranial hemorrhage; (2) addressing challenges with oral anticoagulants; and (3) delineating the optimal roles of percutaneous left atrial appendage occlusion and surgical left atrial appendage closure/excision. This report aims to promote innovative, impactful research that will lead to more personalized, effective use of stroke prevention strategies in people with AF.