Back to Authors

Williamson, Eric E.

https://orcid.org/0000-0002-2066-9612

Mayo Clinic

Mayo Clinic

Citations 44

Technical Note: kV‐independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction
Tao, Shengzhen , Sheedy, Emily N., Bruesewitz, Michael R. , Weber, Nikkole M. , Williams, Kyle , Halaweish, Ahmed F., Schmidt, Bernhard , Williamson, Eric E. , McCollough, C, Sheedy, Emily, Bruesewitz, Michael, Weber, Nikkole, McCollough, Cynthia, Leng, Shuai

Medical Physics | December 18, 2020 | Volume: 48 | Issue: 3 | Pages: 1307-1314

10.1002/mp.14663 Get It

Purpose To determine the accuracy of CT number and calcium score of a kV‐independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. Methods Anthropomorphic chest phantoms were scanned on a third‐generation dual‐source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20‐mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70–140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto‐kV). Phantoms were also scanned at 120 kV using a size‐dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. Results The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto‐kV provided a 25–34% dose reduction compared to AEC alone. Conclusion A kV‐independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto‐kV, this technique can reduce radiation by 25–34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.
CT for Pre- and Postprocedural Evaluation of Transcatheter Mitral Valve Replacement
Ranganath, Praveen , Moore, Alastair , Collins, Jeremy D. , Foley, Thomas A. , Williamson, Eric E. , Rajiah, Prabhakar , Collins, Jeremy , Foley, Thomas , Rajiah, Prabhakar , Guerrero, Mayra

RadioGraphics | October 1, 2020 | Volume: 40 | Issue: 6 | Pages: 1528-1553

10.1148/rg.2020200027 Get It

Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose
Gutjahr, Ralf , Lee, Yong S. , Halaweish, Ahmed F., Suresh, Vighnesh , Weber, Nikkole M. , Vrtiska, Terri J., Williamson, Eric E. , Schmidt, Bernhard , Fletcher, Joel G. , McCollough, Cynthia H.

Journal of Computer Assisted Tomography | July 3, 2019 | Volume: 43 | Issue: 4 | Pages: 612-618

10.1097/rct.0000000000000874 Get It

Objective The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. Methods The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. Results The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. Conclusion The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.
Acute ischemic stroke secondary to cardiac embolus of a ‘foreign body’ material after a redo sternotomy for mitral valve replacement: A case report
Fitzgerald, Seán , Rizvi, Asim , Williamson, Eric E. , Doyle, Karen , Kallmes, David F. , Brinjikji, Waleed , Dai, Daying , Fitzgerald, Seán , Lanzino, Giuseppe

Interventional Neuroradiology | November 14, 2018 | Volume: 25 | Issue: 2 | Pages: 208-211

10.1177/1591019918810538 Get It

Summary Cardiac surgery has been shown to be associated with increased risk of acute ischemic stroke. This report presents a case of a successful mechanical embolectomy procedure to treat a patient for an acute ischemic stroke, which was caused by the cardiac embolization of a ‘foreign body’ containing debris following a redo sternotomy procedure for mitral valve replacement and tricuspid valve annuloplasty.
Predictors of 1-year mortality after transcatheter aortic valve replacement
Greason, Kevin L. , Eleid, Mackram F. , Williamson, Eric E. , Sandhu, Gurpreet S. , Holmes, David R. , King, Katherine S. , Nkomo, Vuyisile T.

Journal of Cardiac Surgery | April 14, 2018 | Volume: 33 | Issue: 5 | Pages: 243-249

10.1111/jocs.13574 Get It

Is Intravenous Administration of Iodixanol Associated with Increased Risk of Acute Kidney Injury, Dialysis, or Mortality? A Propensity Score–adjusted Study
McDonald, Robert J. , Williamson, Eric E. , Kallmes, David F. , McDonald, Jennifer S.

Radiology | July 14, 2017 | Volume: 285 | Issue: 2 | Pages: 414-424

10.1148/radiol.2017161573 Get It

Gadolinium Deposition in Human Brain Tissues after Contrast-enhanced MR Imaging in Adult Patients without Intracranial Abnormalities
McDonald, Robert J. , Kallmes, David F. , Jentoft, Mark E. , Paolini, Michael A., Murray, David , Williamson, Eric E. , Eckel, Laurence J. , Murray, David L., McDonald, Jennifer S.

Radiology | June 27, 2017 | Volume: 285 | Issue: 2 | Pages: 546-554

10.1148/radiol.2017161595 Get It

Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality
Vasconcelos, Rogerio N., Vrtiska, Terri J., Foley, Thomas A. , Macedo, Thanila A. , Cardona, Juan C. Montoya, Williamson, Eric E. , Vasconcelos, Rogerio, McCollough, Cynthia H. , Fletcher, Joel G.

American Journal of Roentgenology | February 22, 2017 | Volume: 208 | Issue: 3 | Pages: 552-563

10.2214/ajr.16.16613 Get It

Spontaneous coronary artery dissection: challenges of coronary computed tomography angiography
Eleid, Mackram F. , Young, Phillip M. , Williamson, Eric E. , Gulati, Rajiv , Tweet, Marysia S. , Hayes, Sharonne N.

European Heart Journal: Acute Cardiovascular Care | January 31, 2017 | Volume: 7 | Issue: 7 | Pages: 609-613

10.1177/2048872616687098 Get It

Background: There is limited understanding of the role of cardiac computed tomography angiography (CCTA) for assessment of patients with spontaneous coronary artery dissection (SCAD). Methods: In this report we describe the diagnostic utility of CCTA in three young women presenting with signs and symptoms of myocardial ischemia who were eventually diagnosed with SCAD. Results: None of the women had traditional atherosclerotic risk factors. SCAD was not initially identified on CCTA in any of the three women, but was visualized during retrospective analysis in two patients after invasive coronary angiography. In two patients follow-up CCTA imaging was used successfully for subsequent management. Conclusions: In patients presenting with signs or symptoms of acute coronary syndrome, SCAD may be missed or not detectable on CCTA. A negative CCTA should not exclude a diagnosis of SCAD, and invasive coronary angiography should be considered for further evaluation.
Acute Kidney Injury After Intravenous Versus Intra-Arterial Contrast Material Administration in a Paired Cohort
Leake, Caleb B., McDonald, Robert J. , Gulati, Rajiv , Katzberg, Richard W. , Williamson, Eric E. , Kallmes, David F. , McDonald, Jennifer S.

Investigative Radiology | June 14, 2016 | Volume: 51 | Issue: 12 | Pages: 804-809

10.1097/rli.0000000000000298 Get It

Objectives The aim of this study was to determine whether intra-arterial administration of contrast material is associated with a higher risk of acute kidney injury (AKI) compared with that of intravenous (IV) administration in a cohort of patients that received both routes of administration. Materials and Methods All patients who received both a contrast-enhanced computed tomography (CT) and a diagnostic or interventional cardiac catheterization between 2000 and 2014 were identified. Patients who lacked sufficient preprocedure and postprocedure serum creatinine results, who were on preexisting renal dialysis, or who underwent additional contrast-enhanced procedures within 7 days of either procedure were excluded. The rate of AKI (serum creatinine ≥0.3 mg/dL or 50% above baseline) was compared after CT scan and cardiac catheterization using McNemar test. Results A total of 1969 patients met all study inclusion criteria. The rate of AKI after CT scan was similar to the rate after catheterization when examining all patients (9.9% CT vs 11% catheterization, P = 0.12). A similar rate of AKI after both procedures was observed regardless of procedure order, catheterization type, and patient baseline estimated glomerular filtration rate. Conclusions Intra-arterial administration of contrast material during cardiac catheterization had a similar risk of AKI as compared with that of CT scanning involving IV administration in a cohort of patients who underwent both procedures. These findings suggest that previously reported much higher rates of AKI after cardiac catheterization compared with that of IV contrast administration reflect higher baseline clinical risk factors for AKI in the former cohort compared with that in the latter.