Kanack and colleagues analyze anti-platelet factor 4 antibodies from 5 patients with vaccine-induced thrombotic thrombocytopenia (VITT) secondary to COVID-19 adenoviral vaccination and antibodies from patients with spontaneous heparin-induced thrombocytopenia (HIT) and classical HIT. VITT antibodies are monoclonal or oligoclonal, similar to spontaneous HIT, whereas classical HIT antibodies are polyclonal. Heparin inhibits antibody-induced platelet activation in VITT, suggesting that heparin should be considered for the treatment of VITT.
Prevalence of heavy chain MGUS by race and family history risk groups using a high-sensitivity screening method
Abstract Mass-spectrometry (MS) assays detect lower levels of monoclonal proteins and result in earlier detection of monoclonal gammopathy of undetermined significance (MGUS). We examined heavy chain MGUS prevalence using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS among 3 risk groups, ages 50 or older: 327 African Americans (AA) and 1223 European Americans (EA) from a clinical biobank and 1093 unaffected first-degree relatives (FDR) of patients with hematologic disorders. Age- and sex-adjusted prevalence rates were directly standardized to 2010 United States population. Prevalence ratios were estimated for comparisons of AA and FDR to the EA group using the Poisson distribution. Results were also compared with population-based prevalence using conventional gel-based methods. Risk groups had similar sex and age distributions. MALDI-TOF MGUS prevalence was higher in the AA (16.5% [95% confidence interval (CI), 12.2%, 20.8%]) and FDR (18.3% [95% CI, 16.6%, 21.6%]) than in EA (10.8% [95% CI, 8.8%, 12.7%]), translating to prevalence ratios of 1.73 (95% CI, 1.31, 2.29) and 1.90 (95% CI, 1.55, 2.34), respectively. MALDI-TOF EA prevalence was over threefold higher than conventional estimates but showed similar age trends. Thus, the MALDI-TOF assay found greater numbers with MGUS but similar relative differences by race, family history, and age as prior studies.
Laboratory Detection and Initial Diagnosis of Monoclonal Gammopathies
Context.— The process for identifying patients with monoclonal gammopathies is complex. Initial detection of a monoclonal immunoglobulin protein (M protein) in the serum or urine often requires compilation of analytical data from several areas of the laboratory. The detection of M proteins depends on adequacy of the sample provided, available clinical information, and the laboratory tests used. Objective.— To develop an evidence-based guideline for the initial laboratory detection of M proteins. Design.— To develop evidence-based recommendations, the College of American Pathologists convened a panel of experts in the diagnosis and treatment of monoclonal gammopathies and the laboratory procedures used for the initial detection of M proteins. The panel conducted a systematic literature review to address key questions. Using the Grading of Recommendations Assessment, Development, and Evaluation approach, recommendations were created based on the available evidence, strength of that evidence, and key judgements as defined in the Grading of Recommendations Assessment, Development, and Evaluation Evidence to Decision framework. Results.— Nine guideline statements were established to optimize sample selection and testing for the initial detection and quantitative measurement of M proteins used to diagnose monoclonal gammopathies. Conclusions.— This guideline was constructed to harmonize and strengthen the initial detection of an M protein in patients displaying symptoms or laboratory features of a monoclonal gammopathy. It endorses more comprehensive initial testing when there is suspicion of amyloid light chain amyloidosis or neuropathies, such as POEMS (polyneuropathy, organomegaly, endocrinopathy, M protein, and skin changes) syndrome, associated with an M protein.
Belantamab mafodotin detection by MASS-FIX and immunofixation
Abstract Patients with immunoglobulin M (IgM) light chain (AL) amyloidosis have a distinct clinical presentation compared with those with non-IgM amyloidosis. We hypothesized that differential immunoglobulin light-chain variable region (IGVL) gene usage may explain the differences in organ involvement, because IGVL usage correlates with organ tropism. IGVL usage was evaluated by mass spectrometry of amyloid deposits (IgM, n = 45; non-IgM, n = 391) and differed across the 2 groups. In the λ family, LV2-08 (13% vs 2%; P < .001) and LV2-14 (36% vs 10%; P < .001) usage was more common in IgM vs non-IgM amyloidosis, whereas LV1-44 (0% vs 10%; P = .02) and LV6-57 (2% vs 18%; P = .004) usage was less common. In the κ family, there was a trend toward higher KV4-01 (11% vs 4%; P = .06) usage in IgM amyloidosis. IGVL usage correlated with disease characteristics/organ tropism. LV2-14 (more common in IgM amyloidosis) has historically been associated with peripheral nerve involvement and lower light chain burden, which were more frequent in IgM amyloidosis. LV1-44 (less common in IgM), associated with cardiac involvement, was less frequent in IgM patients. LV6-57 (less common in IgM) is associated with t(11;14), which was less frequent in IgM patients. In conclusion, IGVL gene usage differs in patients with IgM vs non-IgM amyloidosis and may explain the distinct clinical presentation.
In from the cold: M‐protein light chain glycosylation is positively associated with cold agglutinin titer levels
AbstractBackgroundPrimary cold agglutinin disease (CAD) is a monoclonal antibody (M‐protein) and complement‐mediated chronic hemolytic disease process. Antibody glycosylation can play a role in both antibody half‐life and complement fixation. Recently, M‐protein light chain (LC) glycosylation has been shown to be associated with AL amyloidosis. We hypothesized that M‐protein LC glycosylation is also associated with cold agglutinin (CA) titers and CA‐mediated hemolysis.Study Design and MethodsA cross‐sectional study of patients undergoing CA titer evaluation underwent mass spectrometric analysis for M‐proteins and M‐protein LC glycosylation. A subset of serum samples also underwent evaluation for the ability to trigger cold hemolysis in vitro. M‐protein and M‐protein LC glycosylation rates were compared across CA titer groups, clinical diagnosis, direct antiglobulin testing (DAT) results, and cold in vitro hemolysis rates.ResultsBoth M‐protein and M‐protein LC glycosylation rates significantly differed across CA titer groups with the highest rates in those with elevated CA titers. M‐protein LC glycosylation occurred almost exclusively on IgM kappa M‐proteins and was significantly associated with positive DAT results and a clinical diagnosis of CAD. Cold in vitro hemolysis was demonstrated in two patients who both had a CA titer of more than 512 but there was no significant association with CA titer group or M‐protein LC glycosylation status.ConclusionM‐protein LC glycosylation is significantly associated with higher CA titer levels. Given the role that antibody glycosylation can play in antibody half‐life and complement fixation, further studies are needed to clarify the effects of LC glycosylation within the context of CAD.
Implications of detecting serum monoclonal protein by MASS‐fix following stem cell transplantation in multiple myeloma
SummaryMeasurable residual disease (MRD) assessment by marrow‐based next‐generation flow cytometry (NGF) following autologous stem cell transplantation (ASCT) may lead to false‐negative results due to patchy marrow involvement and extramedullary disease in patients with multiple myeloma. We assessed the value of simultaneous MRD evaluation with NGF and serum matrix‐assisted laser desorption ionization time‐of‐flight mass spectrometry (MASS‐FIX). Of all 61 complete responders who were NGF‐negative for MRD, around day‐100 post ASCT, 59% were MASS‐FIX‐positive. At median follow‐up of 26 months, 69% of MASS‐FIX(+)/NGF(−) patients were alive and progression‐free versus 96% of MASS‐FIX(‐)/NGF(−) patients, P = 0·02. MASS‐FIX, a simple peripheral blood‐based assay complements marrow‐based NGF to accurately prognosticate patients with myeloma.
Automation and validation of a MALDI-TOF MS (Mass-Fix) replacement of immunofixation electrophoresis in the clinical lab
Abstract Objectives A matrix assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) method (Mass-Fix) as a replacement for gel-based immunofixation (IFE) has been recently described. To utilize Mass-Fix clinically, a validated automated method was required. Our aim was to automate the pre-analytical processing, improve positive specimen identification and ergonomics, reduce paper data storage and increase resource utilization without increasing turnaround time. Methods Serum samples were batched and loaded onto a liquid handler along with reagents and a barcoded sample plate. The pre-analytical steps included: (1) Plating immunopurification beads. (2) Adding 10 μl of serum. (3) Bead washing. (4) Eluting the immunoglobulins (Igs), and reducing to separate the heavy and light Ig chains. The resulting plate was transferred to a second low-volume liquid handler for MALDI plate spotting. MALDI-TOF mass spectra were collected. Integrated in-house developed software was utilized for sample tracking, driving data acquisition, data analysis, history tracking, and result reporting. A total of 1,029 residual serum samples were run using the automated system and results were compared to prior electrophoretic results. Results The automated Mass-Fix method was capable of meeting the validation requirements of concordance with IFE, limit of detection (LOD), sample stability and reproducibility with a low repeat rate. Automation and integrated software allowed a single user to process 320 samples in an 8 h shift. Software display facilitated identification of monoclonal proteins. Additionally, the process maintains positive specimen identification, reduces manual pipetting, allows for paper free tracking, and does not significantly impact turnaround time (TAT). Conclusions Mass-Fix is ready for implementation in a high-throughput clinical laboratory.
Glycosylation of immunoglobulin light chains is highly prevalent in cold agglutinin disease
Utilization of LC-MS to Determine Monoclonal Gammopathy-Associated Granulocyte Macrophage Colony Stimulating Factor Antibody and Novel Treatment of Pulmonary Alveolar Proteinosis