Abstract Background While quantitation methods for small-molecule and tryptic peptide bottom-up mass spectrometry (MS) have been well defined, quantitation methods for top-down or middle-up MS approaches have not been as well defined. Therapeutic monoclonal antibodies (t-mAbs) are a group of proteins that can be used to both demonstrate the advantages of top-down or middle-up detection methods over classic tryptic peptide bottom-up along with the growing need for robust quantitation strategies/software for these top-down or middle-up methods. Bottom-up proteolytic digest methods for the t-mAbs tend to suffer from challenges such as limited peptide selection due to potential interference from the polyclonal immunoglobulin background, complicated workflows, and inadequate sensitivity and specificity without laborious purification steps, and therefore have prompted the search for new detection and quantitation methods. Time-of-flight along with Orbitrap MS have recently evolved from the research and/or pharmaceutical setting into the clinical laboratory. With their superior mass measurement accuracy, resolution and scanning speeds, these are ideal platforms for top-down or middle-up characterization and quantitation. Methods We demonstrate a validated, robust, middle-up protein subunit detection and quantitation method for the IgG1 t-mAb, vedolizumab (VEDO), which takes advantage of the high resolution of the Orbitrap MS detection and quantitation software to increase specificity. Results Validated performance characteristics met pre-defined acceptance criteria with simple workflows and rapid turnaround times: characteristics necessary for implementation into a high-volume clinical MS laboratory. Conclusions While the extraction method can easily be used with other IgG1 t-mAbs, the detection and quantitation method may become an option for measurement of other proteins.
Correlation Between Kappa Prozone Effect and IgA Kappa M Proteins in Serum Free Light-Chain Assay
Abstract BACKGROUND Free light chain (FLC) quantification is the most analytically sensitive blood-based method commercially available to diagnose and monitor patients with plasma cell disorders (PCDs). However, instead of directly detecting monoclonal FLCs (mFLCs), FLC assays indirectly assess clonality based on quantifying κ and λ FLCs and determination of the к/λ FLC ratio. Often an abnormal FLC ratio is the only indication of a PCD, and confirmation by a direct method increases diagnostic confidence. The aim of this study was to develop an analytically sensitive method for direct detection of mFLCs. METHODS Patient sera (n = 167) previously assessed by nephelometric FLC quantification and immunofixation electrophoresis (IFE) were affinity enriched for IgG, IgA, and total and free κ and λ light chains and subjected to MALDI-TOF MS. Relative analytical sensitivity of these methods was determined using serially diluted sera containing mFLCs. RESULTS In sera with abnormal FLC ratios (n = 127), 43% of monoclonal proteins were confirmed by IFE, 57% by MALDI-TOF MS without FLC enrichment, and 87% with FLC enrichment MALDI-TOF MS. In sera with normal FLC ratios (n = 40), the FLC MALDI-TOF MS method identified 1 patient with an mFLC. Serial dilution and analysis of mFLC containing sera by IFE, nephelometry, and FLC MALDI-TOF MS demonstrated that FLC MALDI-TOF MS analysis had the highest analytical sensitivity. CONCLUSIONS FLC immunoenrichment coupled to MALDI-TOF MS enables direct detection of mFLCs and significantly increases the confirmation of abnormal serum FLC ratios over IFE and MALDI-TOF MS without FLC enrichment, thereby providing added confidence for diagnosing FLC PCDs.
Mass Spectrometry Approaches for Identification and Quantitation of Therapeutic Monoclonal Antibodies in the Clinical Laboratory
ABSTRACTTherapeutic monoclonal antibodies (MAbs) are an important class of drugs used to treat diseases ranging from autoimmune disorders to B cell lymphomas to other rare conditions thought to be untreatable in the past. Many advances have been made in the characterization of immunoglobulins as a result of pharmaceutical companies investing in technologies that allow them to better understand MAbs during the development phase. Mass spectrometry is one of the new advancements utilized extensively by pharma to analyze MAbs and is now beginning to be applied in the clinical laboratory setting. The rise in the use of therapeutic MAbs has opened up new challenges for the development of assays for monitoring this class of drugs. MAbs are larger and more complex than typical small-molecule therapeutic drugs routinely analyzed by mass spectrometry. In addition, they must be quantified in samples that contain endogenous immunoglobulins with nearly identical structures. In contrast to an enzyme-linked immunosorbent assay (ELISA) for quantifying MAbs, mass spectrometry-based assays do not rely on MAb-specific reagents such as recombinant antigens and/or anti-idiotypic antibodies, and time for development is usually shorter. Furthermore, using molecular mass as a measurement tool provides increased specificity since it is a first-order principle unique to each MAb. This enables rapid quantification of MAbs and multiplexing. This review describes how mass spectrometry can become an important tool for clinical chemists and especially immunologists, who are starting to develop assays for MAbs in the clinical laboratory and are considering mass spectrometry as a versatile platform for the task.
Quantification of the IgG2/4 kappa Monoclonal Therapeutic Eculizumab from Serum Using Isotype Specific Affinity Purification and Microflow LC-ESI-Q-TOF Mass Spectrometry