MRI-based numerical modeling of cardiac pulsed field ablation (PFA) with sub-microsecond pulses
Ladas, Thomas P. , Zyl, Martin van , Tan, Nicholas Y. , Christopoulos, Georgios , Tri, Jason , Yasin, Omar , Sugrue, Alan , Killu, Ammar M. , Munoz, Freddy Del‐Carpio , ASIRVATHAM, SAMUEL, Ivorra, A, García-Sánchez, Tomás , Connolly, Richard J. , DeSimone, Christopher V. , Asirvatham, Samuel J. , Ivorra, Antoni

European Heart Journal | October 15, 2022 | Volume: 43 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehac544.475 Get It

Abstract Background The use of irreversible electroporation (IRE) for cardiac ablation in the management of cardiac arrhythmias, known as Pulsed Field Ablation (PFA), has gained the attention of many researchers, physicians and companies. Despite the demonstrated efficacy and safety profiles of the technique, there are still many open questions. One of them deals with the effective electric field thresholds necessary for cardiac tissue ablation. Contrary to radiofrequency (RF) ablation, where the thermotemporal thresholds for tissue damage are well established, the electric field thresholds for effective IRE are uncertain and depend on the tissue type and the waveform characteristics of the delivered electric field. Purpose The use of numerical models to understand the electric field distribution and the corresponding lesion for a specific electrode geometry are widely used in IRE for cancer treatment. Models can predict ablation volumes when the field thresholds are known or can be used to estimate the field thresholds when the lesion geometry is established post-treatment. The goal of the present study was to build a subject-specific realistic 3D numerical model to assess the ability of modeling to predict PFA lesions. Methods PFA experiments were performed in male mongrel dogs following a protocol approved by the Mayo Clinic Institutional Animal Care and Use Committee. Briefly, animals were sedated and intubated, and two non-irrigated deflectable catheters with an 8-mm tip were positioned on both sides of the interventricular septum under fluoroscopy guidance. Submicrosecond pulses were delivered in a bipolar fashion across both catheters. Sequences of pulses of 300 ns duration (or other durations in that range) were repetitively applied with voltage levels in the kV range. 30 days after the procedure, MRI with late gadolinium enhancement (LGE) were acquired to assess the presence of ablation lesions in the treated tissue. Ventricular areas were segmented from MRI images and 3D volumes were created. The generated 3D geometries were imported into software COMSOL Multiphysics. Realistic 3D geometries of the catheters were placed in the same positions than during the experiments, fluoroscopy videos recorded during the procedures were used as a guidance. The computed electric field intensity distributions were compared to the LGE areas to extract the range of electric field thresholds where the predicted lesion size was compatible with the real size of the LGE areas for each application site and pulsing protocol. Results and conclusions Our results show how the numerical model is able to reproduce the shape of the LGE fibrotic lesion areas observed 30 days after the procedure. Additionally, the model clearly confirms the dose-dependent lesion sizes observed experimentally. This study supports that numerical modeling is a valuable tool for understanding PFA treatments and that it could be used as patient-specific treatment planning tool. Funding Acknowledgement Type of funding sources: Public grant(s) – EU funding. Main funding source(s): European Union's Horizon 2020 research and innovation programme under the Marie Skłodowska-Curie
Effects of Pulsed Electric Fields on the Coronary Arteries in Swine
Ladejobi, Adetola, Christopoulos, Georgios , Tan, Nicholas Y. , Ladas, Thomas P. , Tri, Jason , Zyl, Martin van , Yasin, Omar , Sugrue, Alan , Khabsa, Mariam , Uecker, Darrin, Danitz, David J., Killu, Ammar M. , Holmes, David R. , Asirvatham, Samuel J. , Munoz, Freddy Del‐Carpio , Tan, Nicholas , van Zyl, Martin , DeSimone, Christopher V , Killu, Ammar M , Maor, Elad , Holmes, David R , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Tri, Jason A , Christopoulos, Georgios, Connolly, Richard J. , DeSimone, Christopher V. , Maor, Elad

Circulation: Arrhythmia and Electrophysiology | October 4, 2022 | Volume: 15 | Issue: 10 | Pages: No page available

10.1161/circep.121.010668 Get It

Background: Previous animal studies have shown no significant vascular injury from pulsed electrical field (PEF) ablation. We sought to assess the effect of PEF on swine coronary arteries. Methods: We performed intracoronary and epicardial (near the coronary artery) PEF ablations in swine pretreated with dual antiplatelet and antiarrhythmic therapy. Intracoronary PEF was delivered using MapiT catheters (Biotronik, Berlin), whereas epicardial PEF was delivered using EPT catheters (Boston Scientific, MA). PEF pulse duration was microseconds (Nanoknife 3.0, Angio Dynamics, NY) or nanoseconds (CellFX, Pulse Biosciences, CA). Results: We performed 39 intracoronary ablations in 10 swine and 20 epicardial-pericoronary ablations in 4 separate swine. Intracoronary PEF was delivered at higher energy compared with epicardial PEF (46 [interquartile range, IQR 20–85] J versus 10 [IQR 10–11] J, P < 0.01). Reversible coronary spasm occurred in 49% intracoronary ablations and 45% epicardial ablations ( P =0.80). At the end study, fixed coronary stenosis was demonstrated in 44% intracoronary ablations (80% for microsecond PEF and 18% for nanosecond PEF) and 0% epicardial ablations. Visible hemorrhagic and/or fibrotic myocardial lesions were observed at necropsy with similar frequency between intracoronary and epicardial PEF (45% versus 50%, P =0.70). Nanosecond PEF (49 ablations in 11 swine), when compared with microsecond PEF (10 intracoronary ablations in 3 swine), resulted in lower energy delivery (21 [IQR 10–46] J versus 129 [IQR 24–143] J, P =0.03) and less incidence of fixed coronary stenosis (18% versus 80%, P =0.04). Conclusions: In the swine model, intracoronary PEF resulted both in significant coronary spasm and fixed coronary stenosis. Epicardial PEF, delivered at lower energy, resulted in reversible spasm but no fixed coronary stenosis.
Substrate Characterization and Outcomes of Catheter Ablation of Ventricular Arrhythmias in Patients With Mitral Annular Disjunction
Ezzeddine, Fatima M. , Siontis, Konstantinos C. , Giudicessi, John R. , Ackerman, Michael J. , Killu, Ammar M. , Deshmukh, Abhishek , Madhavan, Malini , Zyl, Martin van , Vaidya, Vaibhav R. , Karki, Roshan , Munger, Thomas M. , Asirvatham, Samuel J. , Munoz, Freddy Del‐Carpio , Giudicessi, J R , Deshmukh, Abhishek J , van Zyl, Martin , Tseng, A S , McLeod, Christopher J , Asirvatham, Samuel J , Del-Carpio Munoz, Freddy , Ezzeddine, Fatima , Tseng, Andrew S. , McLeod, Christopher J.

Circulation: Arrhythmia and Electrophysiology | September 8, 2022 | Volume: 15 | Issue: 9 | Pages: No page available

10.1161/circep.122.011088 Get It

Background: Mitral annular disjunction (MAD) has recently been recognized as an arrhythmogenic entity. Data on the electrophysiological substrate as well as the outcomes of catheter ablation of ventricular arrhythmias in patients with MAD is limited. Methods: Forty patients with MAD (mean age 47±15 years; 70% female) underwent catheter ablation for ventricular arrhythmias. Detailed clinical, electrocardiographic, cardiac imaging, and procedural data were collected. Clinical outcomes were compared between patients who had substrate modification in the MAD area and those who did not. Results: Twenty-three (57.5%) patients had ablation for premature ventricular contractions, 10 (25%) patients for sustained ventricular tachycardia, and 7 (17.5%) patients for premature ventricular contraction-triggered ventricular fibrillation. Mean end-systolic MAD length was 10.58±3.49 mm on transthoracic echocardiography. Seventeen (42.5%) patients had preprocedural cardiac magnetic resonance imaging, and 5 (29%) patients had late gadolinium enhancement. Among the 18 (45%) patients who had abnormal local electrograms (low voltage, long-duration, fractionated, isolated mid-diastolic potentials) during electroanatomical mapping, 10 (25%) patients had abnormal electrograms in the anterolateral mitral annulus and/or MAD area. Substrate modification was performed in 10 (25%) patients. Catheter ablation was acutely successful in 36 (90%) patients (elimination of premature ventricular contraction or noninducibility of ventricular tachycardia). After a median follow-up duration of 54.08 (interquartile range, 10.67–89.79) months, premature ventricular contraction burden decreased from a median of 9.75% (interquartile range, 3.25–14) before the ablation to a median of 4% (interquartile range, 1–7.75) after the ablation ( P =0.03 [95% CI, 0.055–6.5]). Eight (20.5%) patients had repeat ablation for ventricular arrhythmias. Substrate modification of the MAD was associated with a trend toward lower rates of repeat ablation (0% versus 26.7%; P =0.16). Conclusions: Patients with MAD have a complex arrhythmogenic substrate, and catheter ablation is effective in reducing recurrence of ventricular arrhythmias. Substrate mapping and ablation may be considered in these patients.
Cardiac resynchronization therapy response in cardiac sarcoidosis
Shabtaie, Samuel A. , Sehrawat, Ojasav , Lee, Justin Z. , Cha, Yong‐Mei , Mulpuru, Siva K. , Kowlgi, Gurukripa N. , Siontis, Konstantinos C. , Rosenbaum, Andrew , Bois, John P. , AbouEzzeddine, Omar F. , Asirvatham, Samuel J. , Deshmukh, Abhishek , Kowlgi, Narayan G , Rosenbaum, Andrew N , Noseworthy, Peter A , Asirvatham, Samuel J , DeSimone, Christopher V , Deshmukh, Abhishek J , AbouEzzeddine, Omar F , Noseworthy, Peter A. , DeSimone, Christopher V.

Journal of Cardiovascular Electrophysiology | July 23, 2022 | Volume: 33 | Issue: 9 | Pages: 2072-2080

10.1111/jce.15631 Get It

AbstractIntroductionCardiac sarcoidosis (CS) is a nonischemic cardiomyopathy (NICM) characterized by infiltration of noncaseating granulomas involving the heart with highly variable clinical manifestations that can include conduction abnormalities and systolic heart failure. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its efficacy in patients with CS.ObjectiveTo determine if CRT improved cardiac remodeling in patients with CS.MethodsWe retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at the Mayo Clinic enterprise from 2000 to 2021. Baseline characteristics, imaging parameters, heart failure hospitalizations and need for advanced therapies, and major adverse cardiac events (MACE) were assessed.ResultsOur cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. Eighteen (32.7%) patients had definite CS, 21 (38.2%) had probable CS, while 16 (29.1%) had presumed CS, and 26 (47.3%) with extracardiac sarcoidosis. The majority underwent CRT‐D implantation (n = 52, 94.5%) and 3 (5.5%) underwent CRT‐P implantation with 67.3% of implanted devices being upgrades from prior pacemakers or implantable cardioverter defibrillators. At 6 months postimplantation there was no significant improvement in ejection fraction (34.8 ± 10.9% vs. 37.7 ± 14.2%, p = .331) or left ventricular end‐diastolic diameter (58.5 ± 10.2 vs. 57.5 ± 8.1 mm, p = .236), though mild improvement in left ventricular end systolic diameter (49.1 ± 9.9 vs. 45.7± 9.9 mm, p < .0001). Within the first 6 months postimplantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow‐up of 4.1± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent left ventricular assist device implantation and 7 (12.7%) patients died.ConclusionsOur findings suggest variable response to CRT in patients with CS with no overall improvement in ventricular function within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
Cardiac Implantable Electronic Devices in Ebstein Anomaly: Management and Outcomes
Tan, Nicholas Y. , Amin, Mustapha, McLeod, Christopher J. , Stephens, Elizabeth H. , Cannon, Bryan C. , Miranda, William R. , Connolly, Heidi M. , Egbe, Alexander C. , Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J , Stephens, Elizabeth H , Miranda, William R , Connolly, Heidi M , Egbe, Alexander C , Asirvatham, Samuel J , Madhavan, Malini , Dearani, Joseph A.

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010744 Get It

Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P =0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.
Atrial Arrhythmia Ablation in Patients With D-Transposition of the Great Arteries and Atrial Switch
Chiriac, Anca , Cheema, Kamal Preet, Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Perez-Downes, Julio , Umadat, Goyal , Hodge, David O. , Phillips, Sabrina D. , Madhavan, Malini , Asirvatham, Samuel J. , Cheema, Kamal P, Espinosa, Samantha M, Perez-Downes, Julio C , McLeod, Christopher J , Asirvatham, Samuel J , Giardi, Davide , McLeod, Christopher J.

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010546 Get It

Background: Patients with D-transposition of the great arteries and atrial switch have a high incidence of atrial arrhythmias. We sought to analyze the arrhythmia substrate, ablation strategies, and outcomes for catheter ablation in this population. Methods: An in-depth analysis of all clinical and procedural data in patients with D-transposition of the great arteries, atrial baffles, and atrial arrhythmia ablation was performed. Results: A cohort of 32 patients (72% male, mean age 38±7 years) underwent ablation for non-AV nodal reentrant tachycardia atrial arrhythmias, and 4 patients underwent AV nodal reentrant tachycardia ablation. Cavotricuspid isthmus flutter (CTI-flutter) was the most common arrhythmia, encountered in 75% of patients, followed by scar-related intraatrial reentrant tachycardia (non-CTI intraatrial reentrant tachycardia, 53%) and focal atrial tachycardia (focal atrial tachycardia, 6%). Among the 32 patients, 26 underwent 31 procedures at our institution. For patients with prior outside intervention, the index ablation at our institution revealed CTI-dependent flutter in 3/5 cases. However, redo ablation after an index ablation with demonstrated bidirectional CTI block revealed different/new arrhythmia substrates (80% non-CTI intraatrial reentrant tachycardia, 40% focal atrial tachycardia). Achieving bidirectional block across the CTI often required ablating on both sides of the baffle (retroaortic access, 81%; using a baffle leak, 11.5%; or transbaffle puncture, 7.7%). Combined approaches were necessary in 19% to reach the critical tissue. Acute procedural success was 81%, and recurrence was documented in 58% of patients. Despite recurrence, clinical arrhythmia burden was significantly reduced post-ablation ( P <0.001), with rare episodes, amenable to antiarrhythmic therapy. Redo ablation was required in 5 (19%) patients and uncovered new arrhythmia substrates. AV nodal reentrant tachycardia ablation also required transbaffle approaches in 3/4 patients. Conclusions: CTI-dependent flutter was the most common arrhythmia in patients with Dextro-Transposition of the Great Arteries and atrial switch. Transbaffle approaches were often necessary, and, provided that bidirectional CTI block was achieved at the index ablation, late recurrence was due to different arrhythmia mechanisms. Despite recurrence, ablation was associated with significant clinical improvement.
Abstract 12187: Arrhythmia Substrate and Approaches for First-Time and Repeat Catheter Ablation in Patients With D-transposition of the Great Arteries and Atrial Baffles
Chiriac, Anca , Cheema, Kamal Preet P, Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Perez-Downes, Julio , Phillips, Sabrina D. , Madhavan, Malini , Umadat, Goyal , Asirvatham, Samuel J. , McLeod, Christopher J.

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.12187 Get It

Introduction: Atrial arrhythmias are common in patients with D-TGA and atrial switch. We sought to analyze the arrhythmia substrate and catheter ablation approaches and outcomes. Methods: We performed a retrospective review of all clinical and procedural data in patients with D-TGA followed at a large tertiary care center. Results: In a cohort of 152 patients (mean age 30±11 years), atrial tachycardia was present in 69(45%) patients. Ablations were performed in 39(26%) patients: macro-reentrant atrial flutter (N=37), atrial fibrillation (N=4), and focal automatic atrial tachycardia (N=3). Detailed electrophysiology study data was available for 34 patients. At first ablation (N=28), cavo-tricuspid isthmus dependent flutter (CTI, 23(82%)) was most common, followed by right atriotomy-related flutter (IART, 16(57%)) and focal atrial tachycardia (FAT, 1(3.5%)). Bidirectional CTI block often required ablation on both sides of the baffle to complete the isthmus line. Access to the pulmonary venous atrium was obtained in 82% of first-time ablations (via retrograde aortic access, 74%, baffle puncture, 6%, or baffle fenestration, 12%) and in 100% of redo procedures. The first ablation was acutely successful in 25 (89%) patients; the other 3 patients had either partial procedural success (1), failed ablation (1), or underwent an empirical ablation (1). Long-term arrhythmia recurrence occurred in 13(46%) after the first ablation and class III antiarrhythmic medications were utilized in 12 patients. At least one long-term recurrence occurred in 11(44%) patients. Importantly, clinical arrhythmia burden was significantly reduced post-ablation, with rare and short-limited episodes amenable to antiarrhythmic drugs or cardioversion. Repeat ablation was required in 3 cases. Long-term arrhythmia recurrence after a previously completed CTI line involved different arrhythmia mechanisms: scar-related reentry (80%) and automatic atrial tachycardia (40%). Conclusions: Atrial arrhythmia in patients with D-TGA often involves the CTI and atriotomy scars. Ablation of the CTI typically requires access to the pulmonary venous atrium to achieve bidirectional block. Despite late recurrence, the clinical arrhythmic burden is substantially improved.
Abstract 55: Use of a Novel Electrogram Filter to Visualise the Conduction Tissue Signals in the Ventricle in Sinus Rhythm and Arrhythmia: Canine Studies
Padmanabhan, Deepak , Witt, Chance M. , Sugrue, Alan , Killu, Ammar M. , Naksuk, Niyada , Ladewig, Dorothy J., Powers, Joanne, Suddendorf, Scott H., DeSimone, Christopher V. , Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.55 Get It

Background: Conduction tissue in the ventricles is closely intertwined with myocardium. Owing to high velocity of conduction, there is near simultaneous activation , making it difficult to discern. Restricted sampling rates and limited dynamic range make real time signal processing challenging for these signals in routine recording systems. Objectives: We aimed to use novel signal processing techniques in a new system to isolate the conduction tissue signals from the rest of the myocardial activation. Methods: We used the PURE-EP™ (BioSig Technologies, MN) signal processing system to record endocardial and epicardial signals from 6 anesthetized canines in an acute study setting. A novel filter based on proprietary algorithms to isolate the high frequency signal was applied at sites where the electrogram signals were thought to have a conduction tissue component to them. . In addition, ventricular fibrillation (VF) was induced at the end of the experiment and signals were then recorded from the endocardium and the conduction system. Results: This filter was successfully able to isolate conduction tissue signals in the myocardium from those of the ventricular muscle. It did over sense atrial signals at the basal left ventricular septum owing to the high frequency components of the atrial signal at this location. When applied to epicardial signals, it did not pick up any conduction tissue signals. In VF, we could discern signals originating from the conduction system endocardially. (Figure 1) Conclusions: This filter can isolate conduction tissue signals from those of the myocardium and may prove to be a useful adjunct in mapping arrhythmias originating near the conduction system.
Abstract 371: Assessment of Catheter Position Above or Below the Aortic Valve by Evaluation of Characteristics of the Local Electro Gram: an Acute Canine Study
Pa, Deepak, Witt, Chance M. , Sugrue, Alan , Suddendorf, Scott H., Powers, Joanne, Ladewig, Dejae, Drakulic, Budimir , Foxall, Thomas, LADEWIG, DEJAE J., Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.371 Get It

Background: Ablation in the sinuses of Valsalva (SoV) within the aorta is fraught with risk, owing to the proximity of the coronary arteries. Assessment of catheter tip position is not very easy at this location owing to complex local anatomy and poor images from available modalities. Objectives: We propose the use of novel local unipolar electrogram characteristics using a new signal recording system to guide the assessment of catheter tip position in this region. Methods: We recorded unipolar signals from above the SoV, within the coronaries and below the SoV using the PURE-EP™ (BioSig Technologies, MN) signal processing system in 4 anesthetized canines in the setting of an acute study. We used fluoroscopy, intracardiac echocardiography and angiography for confirmation of the position of the catheter tip. We recorded changes in the signals when transitioning between (1) the coronary arteries and the SoV and (2) the SoV and below the SoV. Results: The unipolar signal showed a negative current of injury (COI) when the catheter tip was present in the SoV, whereas within the coronary artery or below the SoV, the COI was positive. We propose that the difference in the distribution of ventricular muscle below and above the SoV is responsible for this phenomenon. These changes in the COI were noted immediately when transitioning from one location to another and were present reproducibly in all the dogs. ( Figure 1 ) Conclusions: Analysis of the changes on the local electrogram can provide information about the location of the catheter tip which could prove critical in saving lives.
Abstract 344: Optimal Serum Potassium, Calcium and Magnesium in the Coronary Care Unit
Krittanawong, Chayakrit , Park, Jae Y, Sharma, Sunita , Gaba, Prakriti , Rosenbaum, Andrew , Hu, Tiffany , Bell, Malcolm R. , Brady, Peter A. , Naksuk, Niyada , Krittanawong, Chayakrit , Thongprayoon, Charat , Herasevich, Vitaly , Kapa, Suraj , Asirvatham, Samuel J.

Circulation: Cardiovascular Quality and Outcomes | March 20, 2022 | Volume: 8 | Issue: suppl_2 | Pages: No page available

10.1161/circoutcomes.8.suppl_2.344 Get It

Background: It is known that hypokalemia, hypocalcemia and hypomagnesemia cause a prolonged QTc interval and are associated with an increased risk of ventricular arrhythmias. However, there are limited data on optimal serum electrolytes for patients admitted to the coronary care unit (CCU). Objective: Here, we aimed to evaluate the relationship between serum potassium, ionized calcium and magnesium levels and in-hospital mortality in the CCU setting. Methods: This retrospective cohort study included 8,498 consecutive patients admitted to the CCU at an academic tertiary medical center from 2004 through 2013. The mean of serum electrolytes was categorized as <3.5, 3.5-<4.0, 4.0-<4.5 (reference), 4.5-<5.0, and ≥5.0 mEq/L for potassium; <4.4, 4.4-<4.6, 4.6-<4.8, 4.8-<5.0 (reference), and ≥5.0 mg/dL for ionized calcium; and <1.8, 1.8-<2.0, 2.0-<2.2 (reference), 2.2-<2.4, and ≥2.4 mg/dL for magnesium. Multivariate logistic regression analysis was used to determine the association between the mean of serum electrolytes and in-hospital mortality. Results: Of the 8,498 patients, 599 (7%) died during hospitalization. Relationship between mean serum potassium (U-shaped), ionized calcium (inverted J-shape) and magnesium (J-shaped) and in-hospital mortality was present in Figure. Serum potassium levels <3.5, 4.5-<5.0 and ≥5.0 mEq/L were independently associated with an increased risk of in-hospital mortality (adjusted OR 1.7 95% CI 1.1-2.5, OR 1.7 95% CI 1.3-2.2, and OR 3.4 95% CI 2.4-4.8, respectively), compared to the reference group. As for serum ionized calcium, the levels of <4.4, 4.4-<4.6, and 4.6-<4.8 mg/dL independently increased risk of mortality (adjusted OR 3.0 95% CI 2.3-4.0, OR 2.0 95% CI 1.5-2.6, and OR 1.4 95% CI, 1.1-1.8, respectively). As for serum magnesium, an only level above 2.4 mg/dL was associated with an increased mortality risk (OR 1.6 95% CI, 1.1-2.2). Conclusions: In the CCU setting, serum potassium 3.5-<4.5 mEq/L, ionized calcium ≥5.0 mg/dL and magnesium <2.4 mg/dL are associated with the lowest in-hospital mortality. These findings do not support supratherapeutic repletion of potassium and magnesium.