Abstract 55: Use of a Novel Electrogram Filter to Visualise the Conduction Tissue Signals in the Ventricle in Sinus Rhythm and Arrhythmia: Canine Studies
Padmanabhan, Deepak , Witt, Chance M. , Sugrue, Alan , Killu, Ammar M. , Naksuk, Niyada , Ladewig, Dorothy J., Powers, Joanne, Suddendorf, Scott H., DeSimone, Christopher V. , Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.55 Get It

Background: Conduction tissue in the ventricles is closely intertwined with myocardium. Owing to high velocity of conduction, there is near simultaneous activation , making it difficult to discern. Restricted sampling rates and limited dynamic range make real time signal processing challenging for these signals in routine recording systems. Objectives: We aimed to use novel signal processing techniques in a new system to isolate the conduction tissue signals from the rest of the myocardial activation. Methods: We used the PURE-EP™ (BioSig Technologies, MN) signal processing system to record endocardial and epicardial signals from 6 anesthetized canines in an acute study setting. A novel filter based on proprietary algorithms to isolate the high frequency signal was applied at sites where the electrogram signals were thought to have a conduction tissue component to them. . In addition, ventricular fibrillation (VF) was induced at the end of the experiment and signals were then recorded from the endocardium and the conduction system. Results: This filter was successfully able to isolate conduction tissue signals in the myocardium from those of the ventricular muscle. It did over sense atrial signals at the basal left ventricular septum owing to the high frequency components of the atrial signal at this location. When applied to epicardial signals, it did not pick up any conduction tissue signals. In VF, we could discern signals originating from the conduction system endocardially. (Figure 1) Conclusions: This filter can isolate conduction tissue signals from those of the myocardium and may prove to be a useful adjunct in mapping arrhythmias originating near the conduction system.
Abstract 637: Utilization of Retrograde Right Bundle Branch Block to Differentiate Atrio Ventricular Nodal from Accessory Pathway Conduction
Henz, Benhur Davi , Dib, Chadi, Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Ladewig, Dorothy J., Hammill, Stephen C., Packer, Douglas L. , Kapa, Suraj , Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 118 | Issue: suppl_18 | Pages: No page available

10.1161/circ.118.suppl_18.s_590-b Get It

Determining whether retrograde ventriculoatrial (VA) conduction is through the AV node (AVN) or an accessory pathway (AP) is critical for successful ablation of supraventricular tachycardia (SVT). With introduction of ventricular extrastimuli (VEST), retrograde right bundle branch block (retro RBBB) may occur and result in abrupt VH interval prolongation. We hypothesized when retrograde conduction is via an AP, VA interval change is less than VH interval change, whereas with retrograde AVN conduction, VA interval change is equal to or greater than VH interval change. We retrospectively reviewed the electrophysiology (EP) studies of patients undergoing ablation for AVNRT (n=55) or AVRT (n=50). The intracardiac electrograms were reviewed for induction of retro RBBB and change in VH and VA intervals during VEST. Parahisian pacing, decremental pacing, arrhythmia diagnosis and ablation outcomes were reviewed. All results were found to be reproducible between two independent observers with inter and intra observer reliability scores of 1.00 for identification of retro RBBB and greater than 0.85 for measurement of VH and VA intervals. Of 105 patients, 84 (80%) had evidence of induced retro RBBB during VEST. The average VH interval increase with induction of retro RBBB was 53.7 ms for patients with retrograde AP conduction and 54.4 ms for patients with AVN conduction (p=ns). The average VA interval increase with induction of retro RBBB was 13.6 ms with AP conduction and 70.1 ms with AVN conduction (P < 0.001). All patients with a greater VH than VA interval change had a final diagnosis of AVRT and those with a VH change less than VA change had AVNRT, yielding sensitivity and specificity of 100%. Using a cutoff of 50 ms for change in VA interval with onset of retro RBBB to diagnose AVNRT accurately identified AVNRT in 100% and AVRT in 95%. Induction of retro RBBB during VEST is common during EP studies for SVT. The relative change in the VH and VA intervals during retro RBBB accurately differentiates retrograde AVN from retrograde AP conduction with strong predictive accuracy. The use of retro RBBB based intervals is a useful technique facilitating the diagnosis of SVT in the EP laboratory, even in the absence of inducible tachycardia.
A cool modality to restore sinus rhythm
Yasin, Omar , Sugrue, Alan , Zyl, Martin van , Ladejobi, Adetola, Tri, Jason , Rynbrandt, J, Seifert, Gregory J., Sanders, R., Pedersen, Joanne, Yngsdal, Lisa, Ladewig, Dorothy J., Taubel, R, Ritrivi, Charles, Asirvatham, S, Friedman, Paul A. , Rynbrandt, Jeff, Seifert, Greg

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0551 Get It

Abstract Background Slowing electrical conduction by cooling the myocardium can be used for defibrillation. We previously demonstrated the efficacy of a small cold device placed in oblique sinus (OS) in terminating atrial fibrillation (AF). However, the parameters needed to achieve effective atrial defibrillation are unknown. Purpose Assess effect of the size of cooled myocardium on frequency of AF termination in acute canine animal models. Methods Sternotomy was performed under general anesthesia in 10 acute canine experiments. AF was induced using rapid atrial pacing and intra-myocardial epinephrine and acetylcholine injections. Once AF sustained for at least 30s, either a cool (7–9°C) or placebo (body temperature) device was placed in the OS. Four device sizes were tested; ½X½, ¾X¾, and 1X1 inch devices and two ¾X¾ inch devices placed side by side simultaneously. Time to AF termination was recorded. Chi-squared or Fisher's exact test were used to compare the frequency of arrhythmia termination with cooling versus placebo. Results A total of 166 applications were performed (89 cool vs 77 placebo) in 10 animal experiments. Overall, AF terminated in 82% of the cooling applications vs. 67.5% of placebo (P=0.03, Figure 1). For the ½X½ inch device 88% of cold applications restored sinus rhythm vs. 63.6% for placebo (P=0.05). The frequency of sinus restoration for cold ¾X¾, 1X1 and two ¾X¾ side by side devices was 86.7%, 83.3% and 70% respectively. Time to sinus restoration when achieved was within three minutes was also not significantly changed. Conclusion Placing a cool device in the oblique sinus can terminate AF and efficacy is not affected by the size of device. Funding Acknowledgement Type of funding source: Private grant(s) and/or Sponsorship. Main funding source(s): MediCool Technologies
Age and Sex Estimation Using Artificial Intelligence From Standard 12-Lead ECGs
Friedman, Paul A. , Ladewig, Dorothy J., Satam, Gaurav, Pellikka, Patricia A. , Munger, Thomas M. , Asirvatham, Samuel J. , Carter, Rickey E. , Asirvatham, Samuel J , Pellikka, Patricia A , Carter, Rickey E , Attia, Zachi I. , Noseworthy, Peter A. , López-Jiménez, Francisco , Scott, Christopher G. , Kapa, Suraj

Circulation: Arrhythmia and Electrophysiology | August 27, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.119.007284 Get It

Background: Sex and age have long been known to affect the ECG. Several biologic variables and anatomic factors may contribute to sex and age-related differences on the ECG. We hypothesized that a convolutional neural network (CNN) could be trained through a process called deep learning to predict a person’s age and self-reported sex using only 12-lead ECG signals. We further hypothesized that discrepancies between CNN-predicted age and chronological age may serve as a physiological measure of health. Methods: We trained CNNs using 10-second samples of 12-lead ECG signals from 499 727 patients to predict sex and age. The networks were tested on a separate cohort of 275 056 patients. Subsequently, 100 randomly selected patients with multiple ECGs over the course of decades were identified to assess within-individual accuracy of CNN age estimation. Results: Of 275 056 patients tested, 52% were males and mean age was 58.6±16.2 years. For sex classification, the model obtained 90.4% classification accuracy with an area under the curve of 0.97 in the independent test data. Age was estimated as a continuous variable with an average error of 6.9±5.6 years (R-squared =0.7). Among 100 patients with multiple ECGs over the course of at least 2 decades of life, most patients (51%) had an average error between real age and CNN-predicted age of <7 years. Major factors seen among patients with a CNN-predicted age that exceeded chronologic age by >7 years included: low ejection fraction, hypertension, and coronary disease ( P <0.01). In the 27% of patients where correlation was >0.8 between CNN-predicted and chronologic age, no incident events occurred over follow-up (33±12 years). Conclusions: Applying artificial intelligence to the ECG allows prediction of patient sex and estimation of age. The ability of an artificial intelligence algorithm to determine physiological age, with further validation, may serve as a measure of overall health.
Safety and compatibility of smart device heart rhythm monitoring in patients with cardiovascular implantable electronic devices
Abudan, Anas, Isath, Ameesh , Ryan, J. , Henrich, Mark, Dugan, Jennifer , Ladewig, Dorothy J., Friedman, Paul A. , Abudan, Anas A , Ryan, James D , Henrich, Mark J, Dugan, Jennifer L, Dillon, John J, Friedman, Paul A , Attia, Zachi I. , Dillon, John

Journal of Cardiovascular Electrophysiology | June 13, 2019 | Volume: 30 | Issue: 9 | Pages: 1602-1609

10.1111/jce.14024 Get It

AbstractIntroductionEmerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration‐approved AliveCor Kardia device in patients with CIEDs.Methods and ResultsWe prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1).ConclusionThe AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.
Intrapulmonary Vein Ablation Without Stenosis: A Novel Balloon‐Based Direct Current Electroporation Approach
Witt, Chance M. , Sugrue, Alan , Padmanabhan, Deepak , Vaidya, Vaibhav R. , Gruba, Sarah M., Rohl, James, Killu, Ammar M. , Naksuk, Niyada , Pederson, Joanne, Suddendorf, Scott H., Ladewig, Dorothy J., Maor, Elad , Holmes, David R. , Asirvatham, Samuel J. , Vaidya, Vaibhav, Suddendorf, Scott, Kapa, Suraj , Asirvatham, Samuel J , Maor, Elad , DeSimone, Christopher V.

Journal of the American Heart Association | July 9, 2018 | Volume: 7 | Issue: 14 | Pages: No page available

10.1161/jaha.118.009575 Get It

Background Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of triggers inside the vein. We previously reported on the acute effects of a novel direct current electroporation approach with a balloon catheter to create lesions inside the PVs in addition to the antrum. In this study, we aimed to determine whether the effects created by this nonthermal ablation method were associated with irreversible lesions and whether PV stenosis or other adverse effects occurred after a survival period. Methods and Results Initial and survival studies were performed in 5 canines. At the initial study, the balloon catheter was inflated to contact the antrum and interior of the PV. Direct current energy was delivered between 2 electrodes on the catheter in ECG‐gated 100 μs pulses. A total of 10 PVs were treated demonstrating significant acute local electrogram diminution (mean amplitude decrease of 61.2±19.8%). After the survival period (mean 27 days), computed tomography imaging showed no PV stenosis. On histologic evaluation, transmural, although not circumferential, lesions were seen in each treated vein. No PV stenosis or esophageal injury was present. Conclusions Irreversible, transmural lesions can be created inside the PV without evidence of stenosis after a 27‐day survival period using this balloon‐based direct current ablation approach. These early data show promise for an ablation approach that could directly treat PV triggers in addition to traditional PV antrum ablation.
Percutaneous epicardial pacing using a novel transverse sinus device
Vaidya, Vaibhav R. , Sugrue, Alan , Padmanabhan, Deepak , Killu, Ammar M. , Naksuk, Niyada , Al‐Masry, Anas Abudan , Isath, Ameesh , Pedersen, Joanne, Yngsdal, Lisa, Ladewig, Dorothy J., Friedman, Paul A. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | June 8, 2018 | Volume: 29 | Issue: 9 | Pages: 1308-1316

10.1111/jce.13661 Get It

AbstractBackgroundTransvenous lead implantation has multiple drawbacks and complications that can be overcome by epicardial lead placement. We aimed to design percutaneously implanted epicardial leads that are anchored through the transverse sinus (TS).Methods and resultsWe designed a novel multielectrode pacing device with four bipole electrode pairs. The device is advanced through the TS, with both ends externalized out of the pericardium. We tested the prototype in one proof‐of‐concept and 5 additional acute canine experiments.The TS device recorded ventricular and atrial electrograms. The median amplitude of near‐field ventricular electrograms was 3.3 mA (IQR 2.0–4.3) and of near‐field atrial electrograms was 2.1 mA (IQR 1.3–2.2). The median ventricular threshold (N = 30) was 1.1 mA (IQR 0.7–3.1) at a median pulse width of 0.5 ms (IQR 0.5–0.5). The median atrial threshold (N = 10) was 2.4 mA (IQR 1.1–7.8) at a median pulse width of 0.5 ms (IQR 0.5–0.9). Right and left ventricular and atrial pacing morphologies were noted while pacing electrodes adjacent to these chambers. Simultaneous left (LV) and right ventricular (RV) pacing showed reduction in QRS duration from 116 ms (RV) and 105 ms (LV) to 91 ms. On necropsy, the device was located in the TS in all animals. There were TS abrasions in one animal, and no other acute complications.ConclusionsThis study highlights a novel approach to epicardial pacing harnessing the unique anatomy of the transverse sinus as an anchoring point. Placement of this novel transverse sinus device was safe and feasible, with acceptable atrial and ventricular thresholds.
Beating Heart Validation of Safety and Efficacy of a Percutaneous Pericardiotomy Tool
Killu, Ammar M. , Naksuk, Niyada , Gaba, Prakriti , Suddendorf, Scott H., Powers, Joanne, Ladewig, Dorothy J., Lerman, Lilach O. , Borlaug, Barry A. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J , Borlaug, Barry A

Journal of Cardiovascular Electrophysiology | October 19, 2016 | Volume: 28 | Issue: 3 | Pages: 357-361

10.1111/jce.13108 Get It

Percutaneous Pericardiotomy ToolIntroductionEpicardial procedures frequently require pericardial manipulation. We aimed to develop a nonsurgical percutaneous pericardial modification tool that may (1) facilitate epicardial‐based procedures by enabling adhesiolysis or (2) attenuate the myocardial constraining effect of the pericardium.MethodsThree novel devices were developed to enable pericardiotomy, all of which can be deployed in over‐the‐wire fashion following percutaneous epicardial access. The grasper permits us to seize the pericardial membrane providing leverage for incision. The scissors enables anterograde cutting maneuvers. The reverse‐slitter allows retrograde incisions; in addition, this device has a deflectable tip that increases the potential cutting area. We optimized these tools for safety by including electrodes to test for phrenic nerve stimulation as well as myocardial stimulation to determine directionality of the cutting devices. The base of the scissors and reverse‐slitter are also blunt ensuring that the cutting element is always away from the myocardium.ResultsFollowing 5 nonbeating heart bench test experiments for prototype development, 11 animal (9 canine, 2 swine) studies were performed. Of these 2 were proof‐of‐concept open chest studies; the remaining 9 were entirely closed‐chest, percutaneous procedures allowing for remodification of the prototypes. The tools successfully permitted incision of the pericardium in all studies. Hemodynamic measurements were assessed postincision and showed no compromise of systolic function. No coronary artery or phrenic nerve damage was seen in any study.ConclusionPercutaneous pericardiotomy is feasible and appears to be safe. It may provide leverage in epicardial‐based procedures and offer treatment options in disease processes characterized by pericardial restraint.
Blood Pressure Responses to Endovascular Stimulation: A Potential Therapy for Autonomic Disorders With Vasodilatation
Naksuk, Niyada , Killu, Ammar M. , Yogeswaran, Vidhushei , Suddendorf, Scott H., Ladewig, Dorothy J., Powers, Joanne, Weber, Sarah L., Madhavan, Malini , Cha, Yong‐Mei , Asirvatham, Samuel J. , Powers, Joanne M, Weber, Sarah, Kapa, Suraj , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | May 28, 2016 | Volume: 27 | Issue: 9 | Pages: 1078-1085

10.1111/jce.13018 Get It

Endovascular Stimulation for Treatment of HypotensionBackgroundWe have previously shown that sympathetic ganglia stimulation via the renal vein rapidly increases blood pressure. This study further investigated the optimal target sites and effective energy levels for stimulation of the renal vasculatures and nearby sympathetic ganglia for rapid increase in blood pressure.MethodsThe pre‐study protocol for endovascular stimulations included 2 minutes of stimulation (1–150 V and 10 pulses per second) and at least 2 minutes of rest during poststimulation. If blood pressure and/or heart rate were changed during the stimulation, time to return to baseline was allowed prior to the next stimulation.ResultsIn 11 acute canine studies, we performed 85 renal artery, 30 renal vein, and 8 hepatic vasculature stimulations. The mean arterial pressure (MAP) rapidly increased during stimulation of renal artery (95 ± 18 mmHg vs. 103 ± 15 mmHg; P < 0.0001), renal vein (90 ± 16 mmHg vs. 102 ± 20 mmHg; P = 0.001), and hepatic vasculatures (74 ± 8 mmHg vs. 82 ± 11 mmHg; P = 0.04). Predictors of a significant increase in MAP were energy >10 V focused on the left renal artery, bilateral renal arteries, and bilateral renal veins (especially the mid segment). Overall, heart rate was unchanged, but muscle fasciculation was observed in 22.0% with an output >10 V (range 15–150 V). Analysis after excluding the stimulations that resulted in fasciculation yielded similar results to the main findings.ConclusionsStimulation of intra‐abdominal vasculatures promptly increased the MAP and thus may be a potential treatment option for hypotension in autonomic disorders. Predictors of optimal stimulation include energy delivery and the site of stimulation (for the renal vasculatures), which informs the design of subsequent research.
Novel Percutaneous Epicardial Autonomic Modulation in the Canine for Atrial Fibrillation: Results of an Efficacy and Safety Study
Madhavan, Malini , Venkatachalam, K, Swale, M., Gard, Joseph J., Johnson, Susan B., Suddendorf, Scott H., Mikell, Susan B. , Ladewig, Dorothy J., NOSBUSH, TONI GRABINGER, Danielsen, Andrew J., Knudson, Mark B., Asirvatham, Samuel J. , Knudson, Mark, DeSimone, Christopher V. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 8, 2016 | Volume: 39 | Issue: 5 | Pages: 407-417

10.1111/pace.12824 Get It

BackgroundEndocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters.MethodsPhase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n = 10). Phase 2: Percutaneous epicardial ablation of GP was done in six dogs using the most efficacious modality identified in phase 1 using two novel catheters.ResultsPhase 1: Direct current (DC) in varying doses (blocking [7–12 μA], electroporation [300–500 μA], ablation [3,000–7,500 μA]), radiofrequency ablation (25–50 W), ultrasound (1.5 MHz), and alcohol (2–5 mL) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5, and 5/7 GP sites. DC (500–5,000 μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation during DC ablation at 5,000 μA. Programmed stimulation induced AF in six dogs, preablation and no atrial arrhythmia in three, flutter in one, and AF in one postablation. Heart rate, blood pressure, effective atrial refractory period, and local atrial electrogram amplitude did not change significantly postablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium.ConclusionPercutaneous epicardial ablation of GP using DC and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of AF in order to minimize additional atrial myocardial ablation.