Back to Authors

Dugan, Jennifer L

Mayo Clinic

Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (Z.I.A., C.V.D.S., V.K.S., J.L.D., C.J.B., M.J.A., S.J.A., J.B., P.A.F.).

Citations 3

Artificial Intelligence-Enabled ECG Algorithm to Identify Patients With Left Ventricular Systolic Dysfunction Presenting to the Emergency Department With Dyspnea
Adedinsewo, Demilade , Carter, Rickey E. , Attia, Zachi I. , Kashou, Anthony H. , Dugan, Jennifer , Albus, Michael, Bellolio, Fernanda , Friedman, Paul A. , Johnson, Patrick, Dugan, Jennifer L, Sheele, Johnathan M. , Carter, Rickey E , Adedinsewo, Demilade A , Bellolio, M Fernanda , Attia, Zachi I , Johnson, Patrick W. , López-Jiménez, Francisco , Noseworthy, Peter A.

Circulation: Arrhythmia and Electrophysiology | August 4, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circep.120.008437 Get It

Background: Identification of systolic heart failure among patients presenting to the emergency department (ED) with acute dyspnea is challenging. The reasons for dyspnea are often multifactorial. A focused physical evaluation and diagnostic testing can lack sensitivity and specificity. The objective of this study was to assess the accuracy of an artificial intelligence-enabled ECG to identify patients presenting with dyspnea who have left ventricular systolic dysfunction (LVSD). Methods: We retrospectively applied a validated artificial intelligence-enabled ECG algorithm for the identification of LVSD (defined as LV ejection fraction ≤35%) to a cohort of patients aged ≥18 years who were evaluated in the ED at a Mayo Clinic site with dyspnea. Patients were included if they had at least one standard 12-lead ECG acquired on the date of the ED visit and an echocardiogram performed within 30 days of presentation. Patients with prior LVSD were excluded. We assessed the model performance using area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity. Results: A total of 1606 patients were included. Median time from ECG to echocardiogram was 1 day (Q1: 1, Q3: 2). The artificial intelligence-enabled ECG algorithm identified LVSD with an area under the receiver operating characteristic curve of 0.89 (95% CI, 0.86–0.91) and accuracy of 85.9%. Sensitivity, specificity, negative predictive value, and positive predictive value were 74%, 87%, 97%, and 40%, respectively. To identify an ejection fraction <50%, the area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity were 0.85 (95% CI, 0.83–0.88), 86%, 63%, and 91%, respectively. NT-proBNP (N-terminal pro-B-type natriuretic peptide) alone at a cutoff of >800 identified LVSD with an area under the receiver operating characteristic curve of 0.80 (95% CI, 0.76–0.84). Conclusions: The ECG is an inexpensive, ubiquitous, painless test which can be quickly obtained in the ED. It effectively identifies LVSD in selected patients presenting to the ED with dyspnea when analyzed with artificial intelligence and outperforms NT-proBNP. Graphic Abstract: A graphic abstract is available for this article.
Safety and compatibility of smart device heart rhythm monitoring in patients with cardiovascular implantable electronic devices
Abudan, Anas, Isath, Ameesh , Ryan, J. , Henrich, Mark, Dugan, Jennifer , Ladewig, Dorothy J., Friedman, Paul A. , Abudan, Anas A , Ryan, James D , Henrich, Mark J, Dugan, Jennifer L, Dillon, John J, Friedman, Paul A , Attia, Zachi I. , Dillon, John

Journal of Cardiovascular Electrophysiology | June 13, 2019 | Volume: 30 | Issue: 9 | Pages: 1602-1609

10.1111/jce.14024 Get It

AbstractIntroductionEmerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration‐approved AliveCor Kardia device in patients with CIEDs.Methods and ResultsWe prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1).ConclusionThe AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.
Novel Bloodless Potassium Determination Using a Signal‐Processed Single‐Lead ECG
Sapir, Yehu , Dugan, Jennifer , Ackerman, Michael J. , Asirvatham, Samuel J. , Striemer, Bryan L., Bukartyk, Jan , Bennet, Kevin E. , Ladewig, Dorothy J., Gilles, Emily J., Sadot, Dan , Geva, Amir B. , Friedman, Paul A. , Dillon, John J, Dugan, Jennifer L, Bruce, Charles J. , Attia, Zachi I. , DeSimone, Christopher V. , Dillon, John J., Somers, Virend K. , Scott, Christopher G. , Asirvatham, Samuel J

Journal of the American Heart Association | January 25, 2016 | Volume: 5 | Issue: 1 | Pages: No page available

10.1161/jaha.115.002746 Get It

Background Hyper‐ and hypokalemia are clinically silent, common in patients with renal or cardiac disease, and are life threatening. A noninvasive, unobtrusive, blood‐free method for tracking potassium would be an important clinical advance. Methods and Results Two groups of hemodialysis patients (development group, n=26; validation group, n=19) underwent high‐resolution digital ECG recordings and had 2 to 3 blood tests during dialysis. Using advanced signal processing, we developed a personalized regression model for each patient to noninvasively calculate potassium values during the second and third dialysis sessions using only the processed single‐channel ECG . In addition, by analyzing the entire development group's first‐visit data, we created a global model for all patients that was validated against subsequent sessions in the development group and in a separate validation group. This global model sought to predict potassium, based on the T wave characteristics, with no blood tests required. For the personalized model, we successfully calculated potassium values with an absolute error of 0.36±0.34 mmol/L (or 10% of the measured blood potassium). For the global model, potassium prediction was also accurate, with an absolute error of 0.44±0.47 mmol/L for the training group (or 11% of the measured blood potassium) and 0.5±0.42 for the validation set (or 12% of the measured blood potassium). Conclusions The signal‐processed ECG derived from a single lead can be used to calculate potassium values with clinically meaningful resolution using a strategy that requires no blood tests. This enables a cost‐effective, noninvasive, unobtrusive strategy for potassium assessment that can be used during remote monitoring.