Back to Authors

Dugan, Jennifer

https://orcid.org/0000-0002-1483-3201

Mayo Clinic

Mayo Clinic

Citations 6

Artificial intelligence-enhanced electrocardiogram for the detection of rheumatic heart disease
Ntsekhe, Mpiko , Harmon, David , Harmon, David M , Ngo, Christie, Ntsekhe, Mpiko , Bhorat, Raeesa, Liu, Kan, Dugan, Jennifer , Ngo, Christie, Friedman, Paul A. , Bagula, Herman, Attia, Zachi I.

European Heart Journal - Digital Health | April 3, 2026 | Volume: 7 | Issue: 4 | Pages: No page available

10.1093/ehjdh/ztag056 Get It

Abstract Aims Rheumatic heart disease (RHD) remains the most prevalent acquired cardiovascular disease among young adults in developing countries, and there is a critical need for an efficient, affordable, and available screening strategy to detect RHD in these resource-limited areas. The 12-lead electrocardiogram (ECG) is a ubiquitous, inexpensive diagnostic tool, and application of artificial intelligence to the ECG (AI-ECG) has allowed for screening of various cardiovascular pathologies. Methods and results Patients aged >18 years with severe RHD with at least one transthoracic echocardiogram and one standard 12-lead ECG performed at Groote Schuur Hospital, Cape Town, within 180 days of each other were eligible. A total of 920 RHD patients were identified, with 2199 corresponding controls from the same medical centre. Patients were allocated to derivation (80%), validation (10%), and testing (10%) groups, respectively. The AI-ECG to detect RHD from a standard 12-lead ECG was built using the Keras framework under Tensorflow backend. In the test group, the AI-ECG for RHD exhibited strong algorithm performance with an AUC of 0.890 (95% Confidence Interval 0.848–0.940) and an accuracy of 83.8%. The algorithm remained robust between RHD presentation: mitral valve alone (AUC 0.913) and mixed mitral and aortic valve disease (AUC 0.858). There were minor performance differences in the subgroup analysis of patient sex, age, and ECG characteristics. Conclusion In this study, an AI-ECG algorithm was successfully developed to screen for advanced RHD from a standard 12-lead ECG, and the AI-ECG performance remained acceptable across most subgroups, including RHD manifestation, patient sex, age <70 years, and ECG characteristics.
Validation of Noninvasive Detection of Hyperkalemia by Artificial Intelligence–Enhanced Electrocardiography in High Acuity Settings
Harmon, David , Dugan, Jennifer , Jentzer, Jacob C. , Attia, Zachi I. , Friedman, Paul A. , Dillon, John , Harmon, David M , Liu, Kan , Dugan, Jennifer , Jentzer, Jacob C , Attia, Zachi I , Dillon, John J

Clinical Journal of the American Society of Nephrology | June 21, 2024 | Volume: 19 | Issue: 8 | Pages: 952-958

10.2215/cjn.0000000000000483 Get It

Key Points Measuring blood potassium has always required access to blood. The surface electrocardiogram, analyzed using an artificial intelligence algorithm, can detect hyperkalemia bloodlessly. The artificial intelligence-analyzed electrocardiogram exhibited a high negative predictive value but substantially lower positive predictive value. Background Artificial intelligence (AI) electrocardiogram (ECG) analysis can enable detection of hyperkalemia. In this validation, we assessed the algorithm's performance in two high acuity settings. Methods An emergency department (ED) cohort (February to August 2021) and a mixed intensive care unit (ICU) cohort (August 2017 to February 2018) were identified and analyzed separately. For each group, pairs of laboratory-collected potassium and 12 lead ECGs obtained within 4 hours of each other were identified. The previously developed AI ECG algorithm was subsequently applied to leads 1 and 2 of the 12 lead ECGs to screen for hyperkalemia (potassium >6.0 mEq/L). Results The ED cohort ( N =40,128) had a mean age of 60 years, 48% were male, and 1% ( N =351) had hyperkalemia. The area under the curve (AUC) of the AI-enhanced ECG (AI-ECG) to detect hyperkalemia was 0.88, with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and positive likelihood ratio (LR+) of 80%, 80%, 3%, 99.8%, and 4.0, respectively, in the ED cohort. Low-eGFR (<30 ml/min) subanalysis yielded AUC, sensitivity, specificity, PPV, NPV, and LR+ of 0.83, 86%, 60%, 15%, 98%, and 2.2, respectively, in the ED cohort. The ICU cohort ( N =2636) had a mean age of 65 years, 60% were male, and 3% ( N =87) had hyperkalemia. The AUC for the AI-ECG was 0.88 and yielded sensitivity, specificity, PPV, NPV, and LR+ of 82%, 82%, 14%, 99%, and 4.6, respectively in the ICU cohort. Low-eGFR subanalysis yielded AUC, sensitivity, specificity, PPV, NPV, and LR+ of 0.85, 88%, 67%, 29%, 97%, and 2.7, respectively in the ICU cohort. Conclusions The AI-ECG algorithm demonstrated a high NPV, suggesting that it is useful for ruling out hyperkalemia, but a low PPV, suggesting that it is insufficient for treating hyperkalemia.
Automated detection of low ejection fraction from a one-lead electrocardiogram: application of an AI algorithm to an electrocardiogram-enabled Digital Stethoscope
Attia, Zachi I. , Dugan, Jennifer , Rideout, Adam, Venkatraman, Subramaniam, Guo, Ling, Noseworthy, Peter A. , Pellikka, Patricia A. , Pham, Steve L, Friedman, Paul A. , Noseworthy, Peter A , Pellikka, Patricia A , Kapa, Suraj , Lopez-Jimenez, Francisco , Attia, Zachi I , Dugan, Jennifer , Maidens, John , Pham, Steve, Kapa, Suraj , López-Jiménez, Francisco

European Heart Journal - Digital Health | May 23, 2022 | Volume: 3 | Issue: 3 | Pages: 373-379

10.1093/ehjdh/ztac030 Get It

Abstract Aims Electrocardiogram (ECG)-enabled stethoscope (ECG-Scope) acquires a single-lead ECGs during cardiac auscultation and may facilitate real-time screening for pathologies not routinely identified by cardiac auscultation alone. We previously demonstrated an artificial intelligence (AI) algorithm can identify left ventricular dysfunction (LVSD) [defined as ejection fraction (EF) ≤ 40%] with an area under the curve (AUC) of 0.91 using a 12-lead ECG. Methods and results One hundred patients referred for clinically indicated echocardiography were prospectively recruited. ECG-Scope recordings with the patient supine and sitting were obtained in multiple electrode locations at the time of the echocardiogram. The AI algorithm for the detection of LVSD was retrained using single leads from ECG-12 and validated against ECG-Scope to determine accuracy for low EF detection (≤35%, &lt;40%, or &lt;50%). We evaluated the algorithm with respect to body position and lead location. Amongst 100 patients (aged 61.3 ± 13.8; 61% male, BMI: 30.0 ± 5.4), eight had EF≤40%, and six had EF 40–50%. The best single recording position was V2 with the patient supine [AUC: 0.88 (CI: 0.80–0.97) for EF≤35%, 0.85 (CI: 0.75–0.95) for EF≤40%, and 0.81 (CI: 0.71–0.90) for EF &lt; 50%]. When using an AI model to select the recording automatically, AUC was 0.91 (CI: 0.84–0.97) for EF≤35%, 0.89 (CI: 0.83–0.96) for EF≤40%, and 0.84 (CI: 0.73–0.94) for EF &lt; 50%. Conclusion An AI algorithm applied to an ECG-enabled stethoscope recording in standard auscultation positions reliably detected the presence of a low EF in this prospective study of patients referred for echocardiography. The ability to screen patients with a possible low EF during routine physical examination may facilitate rapid detection of LVSD.
Artificial Intelligence-Enabled ECG Algorithm to Identify Patients With Left Ventricular Systolic Dysfunction Presenting to the Emergency Department With Dyspnea
Adedinsewo, Demilade , Carter, Rickey E. , Attia, Zachi I. , Kashou, Anthony H. , Dugan, Jennifer , Albus, Michael, Bellolio, Fernanda , Friedman, Paul A. , Johnson, Patrick, Dugan, Jennifer L, Sheele, Johnathan M. , Carter, Rickey E , Adedinsewo, Demilade A , Bellolio, M Fernanda , Attia, Zachi I , Johnson, Patrick W. , López-Jiménez, Francisco , Noseworthy, Peter A.

Circulation: Arrhythmia and Electrophysiology | August 4, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circep.120.008437 Get It

Background: Identification of systolic heart failure among patients presenting to the emergency department (ED) with acute dyspnea is challenging. The reasons for dyspnea are often multifactorial. A focused physical evaluation and diagnostic testing can lack sensitivity and specificity. The objective of this study was to assess the accuracy of an artificial intelligence-enabled ECG to identify patients presenting with dyspnea who have left ventricular systolic dysfunction (LVSD). Methods: We retrospectively applied a validated artificial intelligence-enabled ECG algorithm for the identification of LVSD (defined as LV ejection fraction ≤35%) to a cohort of patients aged ≥18 years who were evaluated in the ED at a Mayo Clinic site with dyspnea. Patients were included if they had at least one standard 12-lead ECG acquired on the date of the ED visit and an echocardiogram performed within 30 days of presentation. Patients with prior LVSD were excluded. We assessed the model performance using area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity. Results: A total of 1606 patients were included. Median time from ECG to echocardiogram was 1 day (Q1: 1, Q3: 2). The artificial intelligence-enabled ECG algorithm identified LVSD with an area under the receiver operating characteristic curve of 0.89 (95% CI, 0.86–0.91) and accuracy of 85.9%. Sensitivity, specificity, negative predictive value, and positive predictive value were 74%, 87%, 97%, and 40%, respectively. To identify an ejection fraction <50%, the area under the receiver operating characteristic curve, accuracy, sensitivity, and specificity were 0.85 (95% CI, 0.83–0.88), 86%, 63%, and 91%, respectively. NT-proBNP (N-terminal pro-B-type natriuretic peptide) alone at a cutoff of >800 identified LVSD with an area under the receiver operating characteristic curve of 0.80 (95% CI, 0.76–0.84). Conclusions: The ECG is an inexpensive, ubiquitous, painless test which can be quickly obtained in the ED. It effectively identifies LVSD in selected patients presenting to the ED with dyspnea when analyzed with artificial intelligence and outperforms NT-proBNP. Graphic Abstract: A graphic abstract is available for this article.
Safety and compatibility of smart device heart rhythm monitoring in patients with cardiovascular implantable electronic devices
Abudan, Anas, Isath, Ameesh , Ryan, J. , Henrich, Mark, Dugan, Jennifer , Ladewig, Dorothy J., Friedman, Paul A. , Abudan, Anas A , Ryan, James D , Henrich, Mark J, Dugan, Jennifer L, Dillon, John J, Friedman, Paul A , Attia, Zachi I. , Dillon, John

Journal of Cardiovascular Electrophysiology | June 13, 2019 | Volume: 30 | Issue: 9 | Pages: 1602-1609

10.1111/jce.14024 Get It

AbstractIntroductionEmerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration‐approved AliveCor Kardia device in patients with CIEDs.Methods and ResultsWe prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1).ConclusionThe AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.
Novel Bloodless Potassium Determination Using a Signal‐Processed Single‐Lead ECG
Sapir, Yehu , Dugan, Jennifer , Ackerman, Michael J. , Asirvatham, Samuel J. , Striemer, Bryan L., Bukartyk, Jan , Bennet, Kevin E. , Ladewig, Dorothy J., Gilles, Emily J., Sadot, Dan , Geva, Amir B. , Friedman, Paul A. , Dillon, John J, Dugan, Jennifer L, Bruce, Charles J. , Attia, Zachi I. , DeSimone, Christopher V. , Dillon, John J., Somers, Virend K. , Scott, Christopher G. , Asirvatham, Samuel J

Journal of the American Heart Association | January 25, 2016 | Volume: 5 | Issue: 1 | Pages: No page available

10.1161/jaha.115.002746 Get It

Background Hyper‐ and hypokalemia are clinically silent, common in patients with renal or cardiac disease, and are life threatening. A noninvasive, unobtrusive, blood‐free method for tracking potassium would be an important clinical advance. Methods and Results Two groups of hemodialysis patients (development group, n=26; validation group, n=19) underwent high‐resolution digital ECG recordings and had 2 to 3 blood tests during dialysis. Using advanced signal processing, we developed a personalized regression model for each patient to noninvasively calculate potassium values during the second and third dialysis sessions using only the processed single‐channel ECG . In addition, by analyzing the entire development group's first‐visit data, we created a global model for all patients that was validated against subsequent sessions in the development group and in a separate validation group. This global model sought to predict potassium, based on the T wave characteristics, with no blood tests required. For the personalized model, we successfully calculated potassium values with an absolute error of 0.36±0.34 mmol/L (or 10% of the measured blood potassium). For the global model, potassium prediction was also accurate, with an absolute error of 0.44±0.47 mmol/L for the training group (or 11% of the measured blood potassium) and 0.5±0.42 for the validation set (or 12% of the measured blood potassium). Conclusions The signal‐processed ECG derived from a single lead can be used to calculate potassium values with clinically meaningful resolution using a strategy that requires no blood tests. This enables a cost‐effective, noninvasive, unobtrusive strategy for potassium assessment that can be used during remote monitoring.