Back to Authors

Dugan, Jennifer

0000-0002-1483-3201

Mayo Clinic

Department of Cardiovascular Disease, Mayo Clinic, Rochester, Minnesota.

Citations 2

Validation of Noninvasive Detection of Hyperkalemia by Artificial Intelligence–Enhanced Electrocardiography in High Acuity Settings
Harmon, David , Dugan, Jennifer , Jentzer, Jacob C. , Attia, Zachi I. , Friedman, Paul A. , Dillon, John , Harmon, David M , Liu, Kan , Dugan, Jennifer , Jentzer, Jacob C , Attia, Zachi I , Dillon, John J

Clinical Journal of the American Society of Nephrology | June 21, 2024 | Volume: 19 | Issue: 8 | Pages: 952-958

10.2215/cjn.0000000000000483 Get It

Key Points Measuring blood potassium has always required access to blood. The surface electrocardiogram, analyzed using an artificial intelligence algorithm, can detect hyperkalemia bloodlessly. The artificial intelligence-analyzed electrocardiogram exhibited a high negative predictive value but substantially lower positive predictive value. Background Artificial intelligence (AI) electrocardiogram (ECG) analysis can enable detection of hyperkalemia. In this validation, we assessed the algorithm's performance in two high acuity settings. Methods An emergency department (ED) cohort (February to August 2021) and a mixed intensive care unit (ICU) cohort (August 2017 to February 2018) were identified and analyzed separately. For each group, pairs of laboratory-collected potassium and 12 lead ECGs obtained within 4 hours of each other were identified. The previously developed AI ECG algorithm was subsequently applied to leads 1 and 2 of the 12 lead ECGs to screen for hyperkalemia (potassium >6.0 mEq/L). Results The ED cohort ( N =40,128) had a mean age of 60 years, 48% were male, and 1% ( N =351) had hyperkalemia. The area under the curve (AUC) of the AI-enhanced ECG (AI-ECG) to detect hyperkalemia was 0.88, with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and positive likelihood ratio (LR+) of 80%, 80%, 3%, 99.8%, and 4.0, respectively, in the ED cohort. Low-eGFR (<30 ml/min) subanalysis yielded AUC, sensitivity, specificity, PPV, NPV, and LR+ of 0.83, 86%, 60%, 15%, 98%, and 2.2, respectively, in the ED cohort. The ICU cohort ( N =2636) had a mean age of 65 years, 60% were male, and 3% ( N =87) had hyperkalemia. The AUC for the AI-ECG was 0.88 and yielded sensitivity, specificity, PPV, NPV, and LR+ of 82%, 82%, 14%, 99%, and 4.6, respectively in the ICU cohort. Low-eGFR subanalysis yielded AUC, sensitivity, specificity, PPV, NPV, and LR+ of 0.85, 88%, 67%, 29%, 97%, and 2.7, respectively in the ICU cohort. Conclusions The AI-ECG algorithm demonstrated a high NPV, suggesting that it is useful for ruling out hyperkalemia, but a low PPV, suggesting that it is insufficient for treating hyperkalemia.
Automated detection of low ejection fraction from a one-lead electrocardiogram: application of an AI algorithm to an electrocardiogram-enabled Digital Stethoscope
Attia, Zachi I. , Dugan, Jennifer , Rideout, Adam, Venkatraman, Subramaniam, Guo, Ling, Noseworthy, Peter A. , Pellikka, Patricia A. , Pham, Steve L, Friedman, Paul A. , Noseworthy, Peter A , Pellikka, Patricia A , Kapa, Suraj , Lopez-Jimenez, Francisco , Attia, Zachi I , Dugan, Jennifer , Maidens, John , Pham, Steve, Kapa, Suraj , López-Jiménez, Francisco

European Heart Journal - Digital Health | May 23, 2022 | Volume: 3 | Issue: 3 | Pages: 373-379

10.1093/ehjdh/ztac030 Get It

Abstract Aims Electrocardiogram (ECG)-enabled stethoscope (ECG-Scope) acquires a single-lead ECGs during cardiac auscultation and may facilitate real-time screening for pathologies not routinely identified by cardiac auscultation alone. We previously demonstrated an artificial intelligence (AI) algorithm can identify left ventricular dysfunction (LVSD) [defined as ejection fraction (EF) ≤ 40%] with an area under the curve (AUC) of 0.91 using a 12-lead ECG. Methods and results One hundred patients referred for clinically indicated echocardiography were prospectively recruited. ECG-Scope recordings with the patient supine and sitting were obtained in multiple electrode locations at the time of the echocardiogram. The AI algorithm for the detection of LVSD was retrained using single leads from ECG-12 and validated against ECG-Scope to determine accuracy for low EF detection (≤35%, &lt;40%, or &lt;50%). We evaluated the algorithm with respect to body position and lead location. Amongst 100 patients (aged 61.3 ± 13.8; 61% male, BMI: 30.0 ± 5.4), eight had EF≤40%, and six had EF 40–50%. The best single recording position was V2 with the patient supine [AUC: 0.88 (CI: 0.80–0.97) for EF≤35%, 0.85 (CI: 0.75–0.95) for EF≤40%, and 0.81 (CI: 0.71–0.90) for EF &lt; 50%]. When using an AI model to select the recording automatically, AUC was 0.91 (CI: 0.84–0.97) for EF≤35%, 0.89 (CI: 0.83–0.96) for EF≤40%, and 0.84 (CI: 0.73–0.94) for EF &lt; 50%. Conclusion An AI algorithm applied to an ECG-enabled stethoscope recording in standard auscultation positions reliably detected the presence of a low EF in this prospective study of patients referred for echocardiography. The ability to screen patients with a possible low EF during routine physical examination may facilitate rapid detection of LVSD.