Abstract 3223: Feasibility and Safety of the Integrated 3D Image and Contact Force-Guided Ablation for Atrial Fibrillation with the Hansen Robotic Catheter Sheath System
Henz, Benhur Davi , Johnson, Susa B, Packer, Douglas L. , Okumura, Yasuo , Johnson, Susan B.

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_725-a Get It

Background: Current technologies to fully “register” surrogate maps onto 3D CT (CartoMerge, NavxMerge) or 3D ICE images (CartoSound) have emerged to guide ablation. The feasibility of navigation with the Hansen Robotic Catheter Sheath System (HRCS) has also been reported. Integrated 3D Image and contact force sensor with this robotic system may allow for feasibility and safety for guiding complex anatomic-based ablation. Methods: Circumferential pulmonary vein (PV) ablation with the robotic system guided by integrated 3D images (CartoMerge, NavxMerge or CartoSound) (n=3), were done and compared to manual manipulation guided by the integrated 3D images (CartoSound) (n=8). Each ablation was performed using contact force ranges of 10 –20 grams (20W, 17 ml/min flow, 30 seconds). Accuracy of PV ablation was assessed by comparing distance from the PV ostia (specific 4 sites) to the ablative points on the 3D image structures, and the corresponding distances of the actual ablative lesions at pathologic exam. Results: Using three integrated 3D image systems, circumferential PV ablation was successfully guided in 6 PVs (3 RSPVs and 3 LSPVs) with the robotic system. During all ablations with contact forces of 10 –20 grams, no impedance rises, pops or type 2 microbubbles were seen. Accuracy of the PV ablation was 0.22±0.84 mm (range 0 –2). The PV rings were 100% circumferential by electroanatomic mapping, yielding an 86±7% (range 80 –98%) uninterrupted circumferential ablative ring around each PV with 1.1 ± 0.4 gaps (3.0 ± 0.9 mm). These resulting parameters were equal to those in the integrated 3D image-based manual navigation (Accuracy: 0.5±0.9 (range 0 –2.5) mm, Gaps:1.3 ± 0.9 ( 2.6 ± 0.9 mm), circumferential lesions 88 ± 10% (range 70 –100). Conclusions: This feasibility study demonstrated successful integrated 3D image and contact force-guided robotic ablation. Contact sensor guided 3D volume construction and real time 3D images accurately replicated atrial and venous anatomy, resulting in successful circumferential ablation.
Abstract 2247: Feasibility of Long Ventricular Transmural Linear Lesions Created with a New Novel Saline-Injection Needle Catheter: Utility for Ablating Scar Related VT
Henz, Benhur Davi , Curley, Michael , Johnson, Susan B., Packer, Douglas L. , Okumura, Yasuo

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_489-d Get It

Introduction: Unstable scar related ventricular tachycardia (VT) is a common problem after myocardial infarction. Aggressive ablation may be limited, however, by incomplete scar penetration with available RF energy delivery technologies. The purpose of this study was to test the feasibility of full thickness linear ablation of infarcted ventricular substrate with a high penetration virtual electrode needle based electrode system. Methods: Chronic infarcted (> 2months) mongrel dogs (35–40 kg) underwent percutaneous catheter ablation of the LV with a saline-injection needle catheter employing an 8 mm 20-GA tip. Constant power at 40W was delivered for 90 sec via the virtual electrode needle during infusion of saline 10 ml/h at 50°C. The lines were created under electroanatomic map guidance and intracardiac ultrasound (ICE). The ejection fraction was monitored immediately before and after the ablation. One week after ablation, the dogs where restudied using CARTO epicardial and endocardial voltage mapping and hemodynamic testing. Results: The ablation lines created by a virtual electrode energy delivery made in the antero-lateral wall showed mean length of 4.4±1.4 cm. The mean area of ablation per lesion in the endocardium, mid myocardium and epicardium was 1.1±1.0, 2.6±1.3 and 1.9±1.3 cm 2 (p<0.05) respectively, with a mean ablation depth of 1.5±0.5 cm. Sixty-four percent of the length of lesions were transmural and in non-transmural areas had an average depth of 90±16% of wall thickness. The mean number of gaps/line was 0.5±0.7 with a length of 0.6 cm. Ejection fraction was 50±14, 52±17 and 52±13% before, after and 1 week post ablation respectively. At one week the epicardial and endocardial areas of low bipolar voltage < 1.5mV and dense scar < 0.5mV in the Carto map were 11.4±1.2 and 7.9±6.1cm 2 respectively which measurements were confirmed at necropsy by macroscopic scar in the epicardium and endocardium of 11.8±4.3 and 6.6±4.1 cm 2 respectively. Conclusion: This new novel saline-injection needle catheter effectively creates continuous long transmural lines in the infarcted LV. These data also confirm that the macroscopic ablation lesions can be consistently and accurately monitored by 3D electroanatomical mapping in both endocardium and epicardium.
Abstract 4648: Mechanism of Tissue Cooling With Cryoenergy Delivery to Pulmonary Veins: Tissue Temperature Distribution and Chonic Esophageal Effects
Dalegrave, Charles, Henz, Benhur Davi , Kolasa, Mark, Miller, Dylan V. , Johnson, Susan B., Packer, Douglas L. , Okumura, Yasuo

Circulation | July 3, 2021 | Volume: 118 | Issue: suppl_18 | Pages: No page available

10.1161/circ.118.suppl_18.s_924-a Get It

Background: Although pulmonary vein (PV) isolation has been used to treat AF, complications create important limitations. New energy sources, including cryothermal, have been developed to minimize these complications. The purpose of this study was to evaluate the effect of PV cryoablation on esophageal (ESO) temperatures acutely and correlate them with chronic effects on the esophageal wall. Methods: A 23 mm cryoballoon was placed in the LA of 10 dogs through a 12 Fr deflectable sheath. PV and ESO temperatures (TEMP) were recorded using 7–9 thermocouples (TC) outside the PVs and on the external and internal ESO surfaces during 2 cryoablations of 4 min duration. Results : Cryoablation of 15 PV (10 RIPV and 5 LIPV) during 1.7±0.6 ablations yielded a total of 168 TC time-TEMP profiles (6.4±2.4/PV). Minimum tissue TEMP was inversely dependent on the distance of the TC from the balloon surface (Table 1 ). All PVs were isolated acutely and 14/15 (93%) chronically. Minimum TEMP achieved at the PV surface and external ESO were similar (−32±8 and −37±9 at targets within 2.5 mm from the balloon respectively [P=NS]). A TEMP decrease at the internal ESO was seen during 15 of 25 (60%) ablations, but was significantly less pronounced than the external TEMP (17.9°C±13.3 and 6.1°C±24.8 [p<0.05]) resulting in a minimum recorded internal TEMP of −6.2°C. The ESO histological examination in 5 dogs showed very limited external lesions in these dogs (depth= 2.2±1.1, width3 18.6±7.4 and length= 12±5.7 mm), but no transmural or internal ulceration, fibrosis or scarring seen. Conclusion: Although PV cryoablation decreases external ESO temperature and produces minor lesions, significant chronic disruptive tissue damage was not seen. Esophageal injury is an unlikely, but potential complication of cryoablation, with internal temperature proving unhelpful in predict negative outcome.
Abstract 637: Utilization of Retrograde Right Bundle Branch Block to Differentiate Atrio Ventricular Nodal from Accessory Pathway Conduction
Henz, Benhur Davi , Dib, Chadi, Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Ladewig, Dorothy J., Hammill, Stephen C., Packer, Douglas L. , Kapa, Suraj , Asirvatham, Samuel J.

Circulation | July 3, 2021 | Volume: 118 | Issue: suppl_18 | Pages: No page available

10.1161/circ.118.suppl_18.s_590-b Get It

Determining whether retrograde ventriculoatrial (VA) conduction is through the AV node (AVN) or an accessory pathway (AP) is critical for successful ablation of supraventricular tachycardia (SVT). With introduction of ventricular extrastimuli (VEST), retrograde right bundle branch block (retro RBBB) may occur and result in abrupt VH interval prolongation. We hypothesized when retrograde conduction is via an AP, VA interval change is less than VH interval change, whereas with retrograde AVN conduction, VA interval change is equal to or greater than VH interval change. We retrospectively reviewed the electrophysiology (EP) studies of patients undergoing ablation for AVNRT (n=55) or AVRT (n=50). The intracardiac electrograms were reviewed for induction of retro RBBB and change in VH and VA intervals during VEST. Parahisian pacing, decremental pacing, arrhythmia diagnosis and ablation outcomes were reviewed. All results were found to be reproducible between two independent observers with inter and intra observer reliability scores of 1.00 for identification of retro RBBB and greater than 0.85 for measurement of VH and VA intervals. Of 105 patients, 84 (80%) had evidence of induced retro RBBB during VEST. The average VH interval increase with induction of retro RBBB was 53.7 ms for patients with retrograde AP conduction and 54.4 ms for patients with AVN conduction (p=ns). The average VA interval increase with induction of retro RBBB was 13.6 ms with AP conduction and 70.1 ms with AVN conduction (P < 0.001). All patients with a greater VH than VA interval change had a final diagnosis of AVRT and those with a VH change less than VA change had AVNRT, yielding sensitivity and specificity of 100%. Using a cutoff of 50 ms for change in VA interval with onset of retro RBBB to diagnose AVNRT accurately identified AVNRT in 100% and AVRT in 95%. Induction of retro RBBB during VEST is common during EP studies for SVT. The relative change in the VH and VA intervals during retro RBBB accurately differentiates retrograde AVN from retrograde AP conduction with strong predictive accuracy. The use of retro RBBB based intervals is a useful technique facilitating the diagnosis of SVT in the EP laboratory, even in the absence of inducible tachycardia.
Characterization of Lesions Created by a Heated, Saline Irrigated Needle-Tip Catheter in the Normal and Infarcted Canine Heart
Dickow, Jannis , Suzuki, Atsushi , Henz, Benhur Davi , Madhavan, Malini , Lehmann, H. Immo , Wang, Songyun , Parker, Kay D., Monahan, Kristi H. , Rettmann, Maryam E. , Curley, Michael , Packer, Douglas L. , Henz, Benhur D, Suzuki, Atsushi

Circulation: Arrhythmia and Electrophysiology | November 17, 2020 | Volume: 13 | Issue: 12 | Pages: No page available

10.1161/circep.120.009090 Get It

Background: Inability to eliminate intramural arrhythmogenic substrate may lead to recurrent ventricular tachycardia after catheter ablation. The aim of the present study was to evaluate intramural and full thickness lesion formation using a heated saline-enhanced radiofrequency (SERF) needle-tip catheter, compared with a conventional ablation catheter in normal and infarcted myocardium. Methods: Twenty-two adult mongrel dogs (30–40 kg, 15 normal and 7 myocardial infarct group) were studied. Lesions were created using the SERF catheter (40 W/50 °C) or a standard contact force (CF) catheter in both groups. Results: Comparing SERF to CF ablation, the SERF catheter produced larger lesion volumes than the standard CF catheter—even with >20 g of CF—in both normal (983.1±905.8 versus 461.9±178.3 mm 3 ; P =0.023) and infarcted left ventricular myocardium (1052.3±543.0 versus 340.3±160.5 mm 3 ; P =0.001). SERF catheter lesions were more often transmural than standard CF lesions with >20 g of CF in both groups (59.1% versus 7.7%; P <0.001 and 60.0% versus 12.5%; P =0.017, respectively). Using the SERF catheter, mean depth of ablated lesions reached 90% of the left ventricular wall in both normal and infarcted myocardium. Conclusions: The SERF catheter created more transmural and larger ablative lesions in both normal and infarcted canine myocardium. SERF ablation is a promising new approach for endocardial intramural and full thickness ablation of ventricular tachycardia substrate that is not accessible with current techniques.
Three-Dimensional Ultrasound for Image-Guided Mapping and Intervention
Henz, Benhur Davi , Johnson, Susan B., Bunch, T. Jared , O'BRIEN, CHRISTINE J., Hodge, David O. , Altman, Andres, Govari, Assaf , Packer, Douglas L. , Okumura, Yasuo

Circulation: Arrhythmia and Electrophysiology | April 30, 2008 | Volume: 1 | Issue: 2 | Pages: 110-119

10.1161/circep.108.769935 Get It

Background— Multiple factors create discrepancies between electroanatomic maps and merged, preacquired computed tomographic images used in guiding atrial fibrillation ablation. Therefore, a Carto-based 3D ultrasound image system (Biosense Webster Inc) was validated in an animal model and tested in 15 atrial fibrillation patients. Methods and Results— Twelve dogs underwent evaluation using a newly developed Carto-based 3D ultrasound system. After fiducial clip markers were percutaneously implanted at critical locations in each cardiac chamber, 3D ultrasound geometries, derived from a family of 2D intracardiac echocardiographic images, were constructed. Point-source error of 3D ultrasound-derived geometries, assessed by actual real-time 2D intracardiac echocardiographic clip sites, was 2.1�1.1 mm for atrial and 2.4�1.2 mm for ventricular sites. These errors were significantly less than the variance on CartoMerge computed tomographic images (atria: 3.3�1.6 mm; ventricles: 4.8�2.0 mm; P< 0.001 for both). Target ablation at each clip, guided only by 3D ultrasound-derived geometry, resulted in lesions within 1.1�1.1 mm of the actual clips. Pulmonary vein ablation guided by 3D ultrasound-derived geometry resulted in circumferential ablative lesions. Mapping in 15 patients produced modestly smaller 3D ultrasound versus electroanatomic map left atrial volumes (98�24 cm 3 versus 109�25 cm 3 , P< 0.05). Three-dimensional ultrasound-guided pulmonary vein isolation and linear ablation in these patients were successfully performed with confirmation of pulmonary vein entrance/exit block. Conclusions— These data demonstrate that 3D ultrasound images seamlessly yield anatomically accurate chamber geometries. Image volumes from the ultrasound system are more accurate than possible with CartoMerge computed tomographic imaging. This clinical study also demonstrates the initial feasibility of this guidance system for ablation in patients with atrial fibrillation.