Ablation of Refractory Ventricular Tachycardia Using Intramyocardial Needle Delivered Heated Saline-Enhanced Radiofrequency Energy: A First-in-Man Feasibility Trial
Packer, Douglas L. , Wilber, David J. , Dyrda, Katia , Nault, Isabelle , Killu, Ammar M. , Kanagasundram, Arvindh N. , Richardson, Travis D. , Stevenson, William G. , Curley, Michael , Investigators, for the SERF, Kapa, Suraj , Dyrda, Katia , Nault, Isabelle , Killu, Ammar M , Kanagasundram, Arvindh , Richardson, Travis , Stevenson, William , Verma, Atul , Curley, Michael , Kapa, Suraj , Verma, Atul , Investigators, for the SERF

Circulation: Arrhythmia and Electrophysiology | July 1, 2022 | Volume: 15 | Issue: 8 | Pages: No page available

10.1161/circep.121.010347 Get It

Background: Ablation of ventricular tachycardia (VT) is limited by the inability to create penetrating lesions to reach intramyocardial origins. Intramural needle ablation using in-catheter, heated saline-enhanced radio frequency (SERF) energy uses convective heating to increase heat transfer and produce deeper, controllable lesions at intramural targets. This first-in-human trial was designed to evaluate the safety and efficacy of SERF needle ablation in patients with refractory VT. Methods: Thirty-two subjects from 6 centers underwent needle electrode ablation. Each had recurrent drug-refractory monomorphic VT after implantable cardioverter defibrillator implantation and prior standard ablation. During the SERF study procedure, one or more VTs were induced and mapped. The SERF needle catheter was used to create intramural lesions at targeted VT site(s). Acute procedural success was defined as noninducibility of the clinical VT after the procedure. Patients underwent follow-up at 30 days, and 3 and 6 months, with implantable cardioverter defibrillator interrogation at follow-up to determine VT recurrence. Results: These refractory VT patients (91% male, 66±10 years, ejection fraction 35±11%; 56% ischemic, and 44% nonischemic) had a median of 45 device therapies (shock/antitachycardia pacing) for VT in the 3 to 6 months pre-SERF ablation. The study catheter was used to deliver an average of 10±5 lesions per case, with an average of 430±295 seconds of radiofrequency time, 122±65 minute of catheter use time, and a procedural duration of 4.3±1.3 hours. Acute procedural success was 97% for eliminating the clinical VT. At average follow-up of 5 months (n=32), device therapies were reduced by 89%. Complications included 2 periprocedural deaths: an embolic mesenteric infarct and cardiogenic shock, 2 mild strokes, and a pericardial effusion treated with pericardiocentesis (n=1). Conclusions: Intramural heated saline needle ablation showed complete acute and satisfactory mid-term control of difficult VTs failing 1 to 5 prior ablations and drug therapy. Further study is warranted to define safety and longer-term efficacy. Registration: URL: https://www.clinicaltrials.gov ; Unique Identifier: NCT03628534 and NCT02994446.
Abstract 2247: Feasibility of Long Ventricular Transmural Linear Lesions Created with a New Novel Saline-Injection Needle Catheter: Utility for Ablating Scar Related VT
Henz, Benhur Davi , Curley, Michael , Johnson, Susan B., Packer, Douglas L. , Okumura, Yasuo

Circulation | July 3, 2021 | Volume: 116 | Issue: suppl_16 | Pages: No page available

10.1161/circ.116.suppl_16.ii_489-d Get It

Introduction: Unstable scar related ventricular tachycardia (VT) is a common problem after myocardial infarction. Aggressive ablation may be limited, however, by incomplete scar penetration with available RF energy delivery technologies. The purpose of this study was to test the feasibility of full thickness linear ablation of infarcted ventricular substrate with a high penetration virtual electrode needle based electrode system. Methods: Chronic infarcted (> 2months) mongrel dogs (35–40 kg) underwent percutaneous catheter ablation of the LV with a saline-injection needle catheter employing an 8 mm 20-GA tip. Constant power at 40W was delivered for 90 sec via the virtual electrode needle during infusion of saline 10 ml/h at 50°C. The lines were created under electroanatomic map guidance and intracardiac ultrasound (ICE). The ejection fraction was monitored immediately before and after the ablation. One week after ablation, the dogs where restudied using CARTO epicardial and endocardial voltage mapping and hemodynamic testing. Results: The ablation lines created by a virtual electrode energy delivery made in the antero-lateral wall showed mean length of 4.4±1.4 cm. The mean area of ablation per lesion in the endocardium, mid myocardium and epicardium was 1.1±1.0, 2.6±1.3 and 1.9±1.3 cm 2 (p<0.05) respectively, with a mean ablation depth of 1.5±0.5 cm. Sixty-four percent of the length of lesions were transmural and in non-transmural areas had an average depth of 90±16% of wall thickness. The mean number of gaps/line was 0.5±0.7 with a length of 0.6 cm. Ejection fraction was 50±14, 52±17 and 52±13% before, after and 1 week post ablation respectively. At one week the epicardial and endocardial areas of low bipolar voltage < 1.5mV and dense scar < 0.5mV in the Carto map were 11.4±1.2 and 7.9±6.1cm 2 respectively which measurements were confirmed at necropsy by macroscopic scar in the epicardium and endocardium of 11.8±4.3 and 6.6±4.1 cm 2 respectively. Conclusion: This new novel saline-injection needle catheter effectively creates continuous long transmural lines in the infarcted LV. These data also confirm that the macroscopic ablation lesions can be consistently and accurately monitored by 3D electroanatomical mapping in both endocardium and epicardium.
Real-time intracardiac echocardiography validation of saline-enhanced radiofrequency needle-tip ablation: lesion characteristics and gross pathology correlation
Dickow, Jannis , Wang, Songyun , Suzuki, Atsushi , Imamura, Kimitake, Parker, Kay D., Newman, Laura K. , Monahan, Kristi H. , Rettmann, Maryam E. , Curley, Michael , Packer, Douglas L. , Lehmann, H. Immo

EP Europace | May 5, 2021 | Volume: 23 | Issue: 11 | Pages: 1826-1836

10.1093/europace/euab121 Get It

Abstract Aims With the implementation of saline-enhanced radiofrequency (SERF) needle-tip ablation, real-time validation of lesion formation is needed for the controllable creation of transmural lesions. The aim of the study was to analyse the ability of two-dimensional intracardiac echocardiography (2D-ICE) to guide and validate SERF ablation in real-time. Methods and results Fifty-six SERF energy deliveries at left ventricular sites of 11 dogs guided by 2D-ICE were analysed (power: 15–50 W; time: 25–120 s; irrigation saline: 60°C with 10 mL/min flow rate). Catheter tip/tissue orientation and lesion formation could be well detected by 2D-ICE in 49 (87.5%) energy deliveries. Gross pathology analysis confirmed excellent 2D-ICE lesion localization, the ability to detect transmural lesions (70% sensitivity, 47% specificity) and positive correlation between 2D-ICE and the corresponding gross pathology measurements of ‘maximal lesion depth’; (repeated measures correlation: rrm = 0.43, P = 0.012) and ‘depth at maximal lesion width’ (D@MW; rrm = 0.51, P = 0.003). The median angle between SERF catheter tip and endocardium was 76° [interquartile range (IQR) 58–83°]. The more perpendicular the catheter tip/tissue orientation was the deeper D@MW (rrm = 0.32, P = 0.045). Grade 3 microbubbles on 2D-ICE during ablation, indicating inadequate catheter tip/tissue contact, was associated with smaller lesion volumes than with Grade 1 microbubbles (284.8 mm3 [IQR 151.3–343.1] vs. 2114.1 mm3 [IQR 1437.0–3026.3], P &lt; 0.001). Conclusion With excellent lesion localization and a 70% detection rate of transmural lesions, 2D-ICE is well suited to validate SERF ablation lesion formation in real-time. The catheter tip/tissue angle impacts the lesion formation and through perpendicular catheter positioning, deeper intramural areas of the myocardium can be reached.
Characterization of Lesions Created by a Heated, Saline Irrigated Needle-Tip Catheter in the Normal and Infarcted Canine Heart
Dickow, Jannis , Suzuki, Atsushi , Henz, Benhur Davi , Madhavan, Malini , Lehmann, H. Immo , Wang, Songyun , Parker, Kay D., Monahan, Kristi H. , Rettmann, Maryam E. , Curley, Michael , Packer, Douglas L. , Henz, Benhur D, Suzuki, Atsushi

Circulation: Arrhythmia and Electrophysiology | November 17, 2020 | Volume: 13 | Issue: 12 | Pages: No page available

10.1161/circep.120.009090 Get It

Background: Inability to eliminate intramural arrhythmogenic substrate may lead to recurrent ventricular tachycardia after catheter ablation. The aim of the present study was to evaluate intramural and full thickness lesion formation using a heated saline-enhanced radiofrequency (SERF) needle-tip catheter, compared with a conventional ablation catheter in normal and infarcted myocardium. Methods: Twenty-two adult mongrel dogs (30–40 kg, 15 normal and 7 myocardial infarct group) were studied. Lesions were created using the SERF catheter (40 W/50 °C) or a standard contact force (CF) catheter in both groups. Results: Comparing SERF to CF ablation, the SERF catheter produced larger lesion volumes than the standard CF catheter—even with >20 g of CF—in both normal (983.1±905.8 versus 461.9±178.3 mm 3 ; P =0.023) and infarcted left ventricular myocardium (1052.3±543.0 versus 340.3±160.5 mm 3 ; P =0.001). SERF catheter lesions were more often transmural than standard CF lesions with >20 g of CF in both groups (59.1% versus 7.7%; P <0.001 and 60.0% versus 12.5%; P =0.017, respectively). Using the SERF catheter, mean depth of ablated lesions reached 90% of the left ventricular wall in both normal and infarcted myocardium. Conclusions: The SERF catheter created more transmural and larger ablative lesions in both normal and infarcted canine myocardium. SERF ablation is a promising new approach for endocardial intramural and full thickness ablation of ventricular tachycardia substrate that is not accessible with current techniques.