Back to Authors

Suzuki, Atsushi

https://orcid.org/0000-0001-9810-928X

Mayo Clinic

St. Mary's Medical Center

Citations 4

Early Impact of Proton Beam Therapy on Electrophysiological Characteristics in a Porcine Model
Imamura, Kimitake, Deisher, A., Dickow, Jannis , Rettmann, Maryam E. , Yasin, Omar , Pepin, M. , Suzuki, Atsushi , Newman, Laura K. , Sun, Xiaojing , Kruse, Jon J. , Merrell, Kenneth W. , Herman, Michael , Foote, Robert L. , Packer, Douglas L. , Deisher, Amanda J, Yasin, Omar Z, Pepin, Mark D , Hohmann, Stephan , Konishi, Hiroki , Suzuki, Atsushi , Newman, Laura K , Kruse, Jon J , Herman, Michael G., Foote, Robert , Packer, Douglas L , Hohmann, Stephan

Circulation: Arrhythmia and Electrophysiology | May 15, 2023 | Volume: 16 | Issue: 6 | Pages: No page available

10.1161/circep.122.011179 Get It

Background: Particle therapy is a noninvasive, catheter-free modality for cardiac ablation. We previously demonstrated the efficacy for creating ablation lesions in the porcine heart. Despite several earlier studies, the exact mechanism of early biophysical effects of proton and photon beam delivery on the myocardium remain incompletely resolved. Methods: Ten normal and 9 infarcted in situ porcine hearts received proton beam irradiation (40 Gy) delivered to the left ventricular myocardium with follow-up for 8 weeks. High-resolution electroanatomical mapping of the left ventricular was performed at baseline and follow-up. Bipolar voltage amplitude, conduction velocity, and connexin-43 were determined within the irradiated and nonirradiated areas. Results: The irradiated area in normal hearts showed a significant reduction of bipolar voltage amplitude (10.1±4.9 mV versus 5.7±3.2, P <0.0001) and conduction velocity (85±26 versus 55±13 cm/s, P =0.03) beginning at 4 weeks after irradiation. In infarcted myocardium after irradiation, bipolar voltage amplitude of the infarct scar (2.0±2.9 versus 0.8±0.7 mV, P =0.008) was significantly reduced as well as the conduction velocity in the infarcted heart (43.7±15.7 versus 26.3±11.4 cm/s, P =0.02). There were no significant changes in bipolar voltage amplitude and conduction velocity in nonirradiated myocardium. Myocytolysis, capillary hyperplasia, and dilation were seen in the irradiated myocardium 8 weeks after irradiation. Active caspase-3 and reduction of connexin-43 expression began in irradiated myocardium 1 week after irradiation and decreased over 8 weeks. Conclusions: Irradiation of the myocardium with proton beams reduce connexin-43 expression, conduction velocity, and bipolar conducted electrogram amplitude in a large porcine model. The changes in biomarkers preceded electrophysiological changes after proton beam therapy.
Spatial Thermodynamics of very High Power-Short Duration Catheter Ablation for Pulmonary Vein Isolation in an in-vivo model
Suzuki, Atsushi , Lehmann, H. Immo , Wang, Songyun , Parker, Kay, Monahan, Kristi H. , Packer, Douglas L. , Suzuki, Atsushi , Parker, Kay, Rettmann, Maryam E.

No container title available | May 10, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162065770.06236007/v1 Get It

Introduction: The spatial thermodynamics of very high power-short duration (vHPSD) radiofrequency (RF) application during pulmonary vein isolation (PVI) in in-vivo model has not been well characterized. This study was conducted to investigate the distance-temperature relationship during vHPSD-RF ablation. Methods: PVI was performed using the vHPSD catheter with the settings of 90W, RF time of 4 sec and 15mL/min irrigation in a canine model. Catheter contact force (CF) of 10-20g was defined as ‘normal’ and CF >20g as ‘firm’ CF. Tissue temperature was monitored using thermocouples implanted at the surface of the left atrial-pulmonary vein junction, left phrenic nerve, and the luminal esophagus. PVI using a standard contact-force sensing catheter (SCF) (settings of 35W, 30sec and 30mL/min irrigation) was performed for comparison. Results: A total of 334 TC profiles in 4 animals was investigated. Time to maximum tissue temperature (MTT) (6.0sec [vHPSD/normal CF] vs. 30.5 sec [SCF/normal CF], p<0.001; 8.0sec [vHPSD/firm CF] vs. 24.0sec [SCF/firm CF], p=0.022) was shorter with vHPSD than in SCF groups. MTT within 10mm from catheter-tip was lower in vHPSD ablation with normal CF than using SCF ablation (median 41.9°C [interquartile-range; 40.2-46.1] vs. 49.5°C [45.9-56.2], p=0.013). The distance margin to keep the MTT below 39ºC, 42ºC, and 50ºC were 4.9mm, 4.2mm, and 3.4mm, respectively in the vHPDS group. This margin was larger (8.0mm, 6.6mm, and 4.6mm) in the SCF group. Conclusion: Our study underscores that vHPSD creates greater resistive heating than conventional catheter ablation.
Characterization of Lesions Created by a Heated, Saline Irrigated Needle-Tip Catheter in the Normal and Infarcted Canine Heart
Dickow, Jannis , Suzuki, Atsushi , Henz, Benhur Davi , Madhavan, Malini , Lehmann, H. Immo , Wang, Songyun , Parker, Kay D., Monahan, Kristi H. , Rettmann, Maryam E. , Curley, Michael , Packer, Douglas L. , Henz, Benhur D, Suzuki, Atsushi

Circulation: Arrhythmia and Electrophysiology | November 17, 2020 | Volume: 13 | Issue: 12 | Pages: No page available

10.1161/circep.120.009090 Get It

Background: Inability to eliminate intramural arrhythmogenic substrate may lead to recurrent ventricular tachycardia after catheter ablation. The aim of the present study was to evaluate intramural and full thickness lesion formation using a heated saline-enhanced radiofrequency (SERF) needle-tip catheter, compared with a conventional ablation catheter in normal and infarcted myocardium. Methods: Twenty-two adult mongrel dogs (30–40 kg, 15 normal and 7 myocardial infarct group) were studied. Lesions were created using the SERF catheter (40 W/50 °C) or a standard contact force (CF) catheter in both groups. Results: Comparing SERF to CF ablation, the SERF catheter produced larger lesion volumes than the standard CF catheter—even with >20 g of CF—in both normal (983.1±905.8 versus 461.9±178.3 mm 3 ; P =0.023) and infarcted left ventricular myocardium (1052.3±543.0 versus 340.3±160.5 mm 3 ; P =0.001). SERF catheter lesions were more often transmural than standard CF lesions with >20 g of CF in both groups (59.1% versus 7.7%; P <0.001 and 60.0% versus 12.5%; P =0.017, respectively). Using the SERF catheter, mean depth of ablated lesions reached 90% of the left ventricular wall in both normal and infarcted myocardium. Conclusions: The SERF catheter created more transmural and larger ablative lesions in both normal and infarcted canine myocardium. SERF ablation is a promising new approach for endocardial intramural and full thickness ablation of ventricular tachycardia substrate that is not accessible with current techniques.
Catheter-Free Arrhythmia Ablation Using Scanned Proton Beams
Suzuki, Atsushi , Deisher, A., Rettmann, Maryam E. , Lehmann, H. Immo , Hohmann, Stephan , Wang, Songyun , Kruse, Jon J. , Cusma, Jack T., Newman, Laura K. , Parker, Kay D., Monahan, Kristi H. , Herman, Michael , Packer, Douglas L. , Deisher, Amanda J, Konishi, Hiroki, Herman, Michael G., Hohmann, Stephan , Suzuki, Atsushi , Konishi, Hiroki

Circulation: Arrhythmia and Electrophysiology | September 13, 2020 | Volume: 13 | Issue: 10 | Pages: No page available

10.1161/circep.120.008838 Get It

Background: Proton beam therapy offers radiophysical properties that are appealing for noninvasive arrhythmia elimination. This study was conducted to use scanned proton beams for ablation of cardiac tissue, investigate electrophysiological outcomes, and characterize the process of lesion formation in a porcine model using particle therapy. Methods: Twenty-five animals received scanned proton beam irradiation. ECG-gated computed tomography scans were acquired at end-expiration breath hold. Structures (atrioventricular junction or left ventricular myocardium) and organs at risk were contoured. Doses of 30, 40, and 55 Gy were delivered during expiration to the atrioventricular junction (n=5) and left ventricular myocardium (n=20) of intact animals. Results: In this study, procedural success was tracked by pacemaker interrogation in the atrioventricular junction group, time-course magnetic resonance imaging in the left ventricular group, and correlation of lesion outcomes displayed in gross and microscopic pathology. Protein extraction (active caspase-3) was performed to investigate tissue apoptosis. Doses of 40 and 55 Gy caused slowing and interruption of cardiac impulse propagation at the atrioventricular junction. In 40 left ventricular irradiated targets, all lesions were identified on magnetic resonance after 12 weeks, being consistent with outcomes from gross pathology. In the majority of cases, lesion size plateaued between 12 and 16 weeks. Active caspase-3 was seen in lesions 12 and 16 weeks after irradiation but not after 20 weeks. Conclusions: Scanned proton beams can be used as a tool for catheter-free ablation, and time-course of tissue apoptosis was consistent with lesion maturation.