Back to Authors

Herman, Michael G.

Mayo Clinic

Mayo Clinic

Citations 17

Designing a Collaborative Immersive Visualization System for Radiation Treatment Planning Teams
Tran, Kiet , Broske, Matthias , Herman, Michael G., Interrante, Victoria , Rosenberg, Evan Suma , Mundy, Daniel, Keefe, Daniel F. , Mundy, Daniel W.

IEEE Transactions on Visualization and Computer Graphics | April 23, 2026 | Volume: 32 | Issue: 7 | Pages: 6712-6725

10.1109/tvcg.2026.3686821 Get It

A Radiomics-Based Classifier for the Progression of Oropharyngeal Cancer Treated with Definitive Radiotherapy
Garcia, D. , Jeans, Elizabeth B. , Morris, Lindsay K., Shiraishi, Satomi , Laughlin, Brady S. , Rwigema, Jean‐Claude M. , Foote, Robert L. , Herman, Michael , Garcia, Darwin A , Foote, Robert , Herman, Michael G., Qian, Jing , Shiraishi, Satomi , Laughlin, Brady S , Rong, Yi , Qian, Jing

Cancers | July 24, 2023 | Volume: 15 | Issue: 14 | Pages: 3715

10.3390/cancers15143715 Get It

In this study, we investigated whether radiomics features from pre-treatment positron emission tomography (PET) images could be used to predict disease progression in patients with HPV-positive oropharyngeal cancer treated with definitive proton or x-ray radiotherapy. Machine learning models were built using a dataset from Mayo Clinic, Rochester, Minnesota (n = 72) and tested on a dataset from Mayo Clinic, Phoenix, Arizona (n = 22). A total of 71 clinical and radiomics features were considered. The Mann–Whitney U test was used to identify the top 2 clinical and top 20 radiomics features that were significantly different between progression and progression-free patients. Two dimensionality reduction methods were used to define two feature sets (manually filtered or machine-driven). A forward feature selection scheme was conducted on each feature set to build models of increased complexity (number of input features from 1 to 6) and evaluate model robustness and overfitting. The machine-driven features had superior performance and were less prone to overfitting compared to the manually filtered features. The four-variable Gaussian Naïve Bayes model using the ‘Radiation Type’ clinical feature and three machine-driven features achieved a training accuracy of 79% and testing accuracy of 77%. These results demonstrate that radiomics features can provide risk stratification beyond HPV-status to formulate individualized treatment and follow-up strategies.
Early Impact of Proton Beam Therapy on Electrophysiological Characteristics in a Porcine Model
Imamura, Kimitake, Deisher, A., Dickow, Jannis , Rettmann, Maryam E. , Yasin, Omar , Pepin, M. , Suzuki, Atsushi , Newman, Laura K. , Sun, Xiaojing , Kruse, Jon J. , Merrell, Kenneth W. , Herman, Michael , Foote, Robert L. , Packer, Douglas L. , Deisher, Amanda J, Yasin, Omar Z, Pepin, Mark D , Hohmann, Stephan , Konishi, Hiroki , Suzuki, Atsushi , Newman, Laura K , Kruse, Jon J , Herman, Michael G., Foote, Robert , Packer, Douglas L , Hohmann, Stephan

Circulation: Arrhythmia and Electrophysiology | May 15, 2023 | Volume: 16 | Issue: 6 | Pages: No page available

10.1161/circep.122.011179 Get It

Background: Particle therapy is a noninvasive, catheter-free modality for cardiac ablation. We previously demonstrated the efficacy for creating ablation lesions in the porcine heart. Despite several earlier studies, the exact mechanism of early biophysical effects of proton and photon beam delivery on the myocardium remain incompletely resolved. Methods: Ten normal and 9 infarcted in situ porcine hearts received proton beam irradiation (40 Gy) delivered to the left ventricular myocardium with follow-up for 8 weeks. High-resolution electroanatomical mapping of the left ventricular was performed at baseline and follow-up. Bipolar voltage amplitude, conduction velocity, and connexin-43 were determined within the irradiated and nonirradiated areas. Results: The irradiated area in normal hearts showed a significant reduction of bipolar voltage amplitude (10.1±4.9 mV versus 5.7±3.2, P <0.0001) and conduction velocity (85±26 versus 55±13 cm/s, P =0.03) beginning at 4 weeks after irradiation. In infarcted myocardium after irradiation, bipolar voltage amplitude of the infarct scar (2.0±2.9 versus 0.8±0.7 mV, P =0.008) was significantly reduced as well as the conduction velocity in the infarcted heart (43.7±15.7 versus 26.3±11.4 cm/s, P =0.02). There were no significant changes in bipolar voltage amplitude and conduction velocity in nonirradiated myocardium. Myocytolysis, capillary hyperplasia, and dilation were seen in the irradiated myocardium 8 weeks after irradiation. Active caspase-3 and reduction of connexin-43 expression began in irradiated myocardium 1 week after irradiation and decreased over 8 weeks. Conclusions: Irradiation of the myocardium with proton beams reduce connexin-43 expression, conduction velocity, and bipolar conducted electrogram amplitude in a large porcine model. The changes in biomarkers preceded electrophysiological changes after proton beam therapy.
Dosimetric Assessment of a High Precision System for Mouse Proton Irradiation to Assess Spinal Cord Toxicity
Howard, Michelle E. , Denbeigh, Janet M. , Debrot, Emily , Garcia, D. , Remmes, Nicholas B. , Herman, Michael , Beltran, Chris , Garcia, Darwin A, Herman, Michael G., Beltran, Chris J., Beltran, Chris J , Garcia, Darwin A

Radiation Research | May 20, 2021 | Volume: 195 | Issue: 6 | Pages: No page available

10.1667/rade-20-00153.1 Get It

Inhibition of ATM Induces Hypersensitivity to Proton Irradiation by Upregulating Toxic End Joining
Zhou, Qin , Howard, Michelle E. , Tu, Xinyi , Zhu, Qian , Denbeigh, Janet M. , Remmes, Nicholas B. , Herman, Michael , Beltran, Chris , Greipp, Patricia T. , Wang, Liewei , Johnson, Neil , Mutter, Robert W. , Herman, Michael G., Beltran, Chris J., Boughey, JC , Beltran, Chris J , Greipp, Patricia T , Yuan, Jian , Boughey, Judy C. , Goetz, Matthew P. , Sarkaria, Jann N. , Lou, Zhenkun

Cancer Research | February 17, 2021 | Volume: 81 | Issue: 12 | Pages: 3333-3346

10.1158/0008-5472.can-20-2960 Get It

Abstract Proton Bragg peak irradiation has a higher ionizing density than conventional photon irradiation or the entrance of the proton beam profile. Whether targeting the DNA damage response (DDR) could enhance vulnerability to the distinct pattern of damage induced by proton Bragg peak irradiation is currently unknown. Here, we performed genetic or pharmacologic manipulation of key DDR elements and evaluated DNA damage signaling, DNA repair, and tumor control in cell lines and xenografts treated with the same physical dose across a radiotherapy linear energy transfer spectrum. Radiotherapy consisted of 6 MV photons and the entrance beam or Bragg peak of a 76.8 MeV spot scanning proton beam. More complex DNA double-strand breaks (DSB) induced by Bragg peak proton irradiation preferentially underwent resection and engaged homologous recombination (HR) machinery. Unexpectedly, the ataxia-telangiectasia mutated (ATM) inhibitor, AZD0156, but not an inhibitor of ATM and Rad3-related, rendered cells hypersensitive to more densely ionizing proton Bragg peak irradiation. ATM inhibition blocked resection and shunted more DSBs to processing by toxic ligation through nonhomologous end-joining, whereas loss of DNA ligation via XRCC4 or Lig4 knockdown rescued resection and abolished the enhanced Bragg peak cell killing. Proton Bragg peak monotherapy selectively sensitized cell lines and tumor xenografts with inherent HR defects, and the repair defect induced by ATM inhibitor coadministration showed enhanced efficacy in HR-proficient models. In summary, inherent defects in HR or administration of an ATM inhibitor in HR-proficient tumors selectively enhances the relative biological effectiveness of proton Bragg peak irradiation. Significance: Coadministration of an ATM inhibitor rewires DNA repair machinery to render cancer cells uniquely hypersensitive to DNA damage induced by the proton Bragg peak, which is characterized by higher density ionization. See related commentary by Nickoloff, p. 3156
Catheter-Free Arrhythmia Ablation Using Scanned Proton Beams
Suzuki, Atsushi , Deisher, A., Rettmann, Maryam E. , Lehmann, H. Immo , Hohmann, Stephan , Wang, Songyun , Kruse, Jon J. , Cusma, Jack T., Newman, Laura K. , Parker, Kay D., Monahan, Kristi H. , Herman, Michael , Packer, Douglas L. , Deisher, Amanda J, Konishi, Hiroki, Herman, Michael G., Hohmann, Stephan , Suzuki, Atsushi , Konishi, Hiroki

Circulation: Arrhythmia and Electrophysiology | September 13, 2020 | Volume: 13 | Issue: 10 | Pages: No page available

10.1161/circep.120.008838 Get It

Background: Proton beam therapy offers radiophysical properties that are appealing for noninvasive arrhythmia elimination. This study was conducted to use scanned proton beams for ablation of cardiac tissue, investigate electrophysiological outcomes, and characterize the process of lesion formation in a porcine model using particle therapy. Methods: Twenty-five animals received scanned proton beam irradiation. ECG-gated computed tomography scans were acquired at end-expiration breath hold. Structures (atrioventricular junction or left ventricular myocardium) and organs at risk were contoured. Doses of 30, 40, and 55 Gy were delivered during expiration to the atrioventricular junction (n=5) and left ventricular myocardium (n=20) of intact animals. Results: In this study, procedural success was tracked by pacemaker interrogation in the atrioventricular junction group, time-course magnetic resonance imaging in the left ventricular group, and correlation of lesion outcomes displayed in gross and microscopic pathology. Protein extraction (active caspase-3) was performed to investigate tissue apoptosis. Doses of 40 and 55 Gy caused slowing and interruption of cardiac impulse propagation at the atrioventricular junction. In 40 left ventricular irradiated targets, all lesions were identified on magnetic resonance after 12 weeks, being consistent with outcomes from gross pathology. In the majority of cases, lesion size plateaued between 12 and 16 weeks. Active caspase-3 was seen in lesions 12 and 16 weeks after irradiation but not after 20 weeks. Conclusions: Scanned proton beams can be used as a tool for catheter-free ablation, and time-course of tissue apoptosis was consistent with lesion maturation.
AAPM medical physics practice guideline 7.a.: Supervision of medical physicist assistants
Seibert, J. Anthony , Blatnica, A, Clements, Jessica B., Halvorsen, Per H. , Herman, Michael , Johnson, Jennifer L. , Schueler, Beth A. , Martin, Melissa , Palta, Jatinder , Pfeiffer, D , Pizzutiello, R, Prisciandaro, Joann I. , Sherouse, George W., Herman, Michael G.

Journal of Applied Clinical Medical Physics | December 4, 2019 | Volume: 21 | Issue: 7 | Pages: 11-15

10.1002/acm2.12774 Get It

AbstractThe American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States.The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner.Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized.The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM’s Executive Committee May 28, 2019
Optimization of motion management parameters in a synchrotron‐based spot scanning system
Johnson, J. , Herman, Michael , Kruse, Jon J. , Johnson, Jedediah E, Herman, Michael G.

Journal of Applied Clinical Medical Physics | September 20, 2019 | Volume: 20 | Issue: 9 | Pages: 69-77

10.1002/acm2.12702 Get It

AbstractPurposeTo quantify the effects of combining layer‐based repainting and respiratory gating as a strategy to mitigate the dosimetric degradation caused by the interplay effect between a moving target and dynamic spot‐scanning proton delivery.MethodsAn analytic routine modeled three‐dimensional dose distributions of pencil‐beam proton plans delivered to a moving target. Spot positions and weights were established for a single field to deliver 100 cGy to a static, 15‐cm deep, 3‐cm radius spherical clinical target volume with a 1‐cm isotropic internal target volume expansion. The interplay effect was studied by modeling proton delivery from a clinical synchrotron‐based spot scanning system and respiratory target motion, patterned from surrogate patient breathing traces. Motion both parallel and orthogonal to the beam scanning direction was investigated. Repainting was modeled using a layer‐based technique. For each of 13 patient breathing traces, the dose from 20 distinct delivery schemes (combinations of four gate window amplitudes and five repainting techniques) was computed. Delivery strategies were inter‐compared based on target coverage, dose homogeneity, high dose spillage, and delivery time.ResultsNotable degradation and variability in plan quality were observed for ungated delivery. Decreasing the gate window reduced this variability and improved plan quality at the expense of longer delivery times. Dose deviations were substantially greater for motion orthogonal to the scan direction when compared with parallel motion. Repainting coupled with gating was effective at partially restoring dosimetric coverage at only a fraction of the delivery time increase associated with very small gate windows alone. Trends for orthogonal motion were similar, but more complicated, due to the increased severity of the interplay.ConclusionsLayer‐based repainting helps suppress the interplay effect from intra‐gate motion, with only a modest penalty in delivery time. The magnitude of the improvement in target coverage is strongly influenced by individual patient breathing patterns and the tumor motion trajectory.
The Medical Physicist in the balance
Herman, Michael , Herman, Michael G.

Journal of Applied Clinical Medical Physics | June 24, 2019 | Volume: 20 | Issue: 7 | Pages: 4-6

10.1002/acm2.12669 Get It

Clinical implementation of respiratory‐gated spot‐scanning proton therapy: An efficiency analysis of active motion management
Gelover, Edgar, Deisher, A., Herman, Michael , Johnson, J. , Kruse, Jon J. , Tryggestad, E., Deisher, Amanda J, Herman, Michael G., Johnson, Jedediah E, Tryggestad, Erik J

Journal of Applied Clinical Medical Physics | April 11, 2019 | Volume: 20 | Issue: 5 | Pages: 99-108

10.1002/acm2.12584 Get It

AbstractPurposeThe aim of this work is to describe the clinical implementation of respiratory‐gated spot‐scanning proton therapy (SSPT) for the treatment of thoracic and abdominal moving targets. The experience of our institution is summarized, from initial acceptance and commissioning tests to the development of standard clinical operating procedures for simulation, motion assessment, motion mitigation, treatment planning, and gated SSPT treatment delivery.Materials and methodsA custom respiratory gating interface incorporating the Real‐Time Position Management System (RPM, Varian Medical Systems, Inc., Palo Alto, CA, USA) was developed in‐house for our synchrotron‐based delivery system. To assess gating performance, a motion phantom and radiochromic films were used to compare gated vs nongated delivery. Site‐specific treatment planning protocols and conservative motion cutoffs were developed, allowing for free‐breathing (FB), breath‐holding (BH), or phase‐gating (Ph‐G). Room usage efficiency of BH and Ph‐G treatments was retrospectively evaluated using beam delivery data retrieved from our record and verify system and DICOM files from patient‐specific quality assurance (QA) procedures.ResultsMore than 70 patients were treated using active motion management between the launch of our motion mitigation program in October 2015 and the end date of data collection of this study in January 2018. During acceptance procedures, we found that overall system latency is clinically‐suitable for Ph‐G. Regarding room usage efficiency, the average number of energy layers delivered per minute was <10 for Ph‐G, 10‐15 for BH and ≥15 for FB, making Ph‐G the slowest treatment modality. When comparing to continuous delivery measured during pretreatment QA procedures, the median values of BH treatment time were extended from 6.6 to 9.3 min (+48%). Ph‐G treatments were extended from 7.3 to 13.0 min (+82%).ConclusionsActive motion management has been crucial to the overall success of our SSPT program. Nevertheless, our conservative approach has come with an efficiency cost that is more noticeable in Ph‐G treatments and should be considered in decision‐making.