Back to Authors

Wilber, David J.

https://orcid.org/0000-0002-5086-8217

Mayo Clinic

Loyola University Medical Center

Citations 5

Ablation of Refractory Ventricular Tachycardia Using Intramyocardial Needle Delivered Heated Saline-Enhanced Radiofrequency Energy: A First-in-Man Feasibility Trial
Packer, Douglas L. , Wilber, David J. , Dyrda, Katia , Nault, Isabelle , Killu, Ammar M. , Kanagasundram, Arvindh N. , Richardson, Travis D. , Stevenson, William G. , Curley, Michael , Investigators, for the SERF, Kapa, Suraj , Dyrda, Katia , Nault, Isabelle , Killu, Ammar M , Kanagasundram, Arvindh , Richardson, Travis , Stevenson, William , Verma, Atul , Curley, Michael , Kapa, Suraj , Verma, Atul , Investigators, for the SERF

Circulation: Arrhythmia and Electrophysiology | July 1, 2022 | Volume: 15 | Issue: 8 | Pages: No page available

10.1161/circep.121.010347 Get It

Background: Ablation of ventricular tachycardia (VT) is limited by the inability to create penetrating lesions to reach intramyocardial origins. Intramural needle ablation using in-catheter, heated saline-enhanced radio frequency (SERF) energy uses convective heating to increase heat transfer and produce deeper, controllable lesions at intramural targets. This first-in-human trial was designed to evaluate the safety and efficacy of SERF needle ablation in patients with refractory VT. Methods: Thirty-two subjects from 6 centers underwent needle electrode ablation. Each had recurrent drug-refractory monomorphic VT after implantable cardioverter defibrillator implantation and prior standard ablation. During the SERF study procedure, one or more VTs were induced and mapped. The SERF needle catheter was used to create intramural lesions at targeted VT site(s). Acute procedural success was defined as noninducibility of the clinical VT after the procedure. Patients underwent follow-up at 30 days, and 3 and 6 months, with implantable cardioverter defibrillator interrogation at follow-up to determine VT recurrence. Results: These refractory VT patients (91% male, 66±10 years, ejection fraction 35±11%; 56% ischemic, and 44% nonischemic) had a median of 45 device therapies (shock/antitachycardia pacing) for VT in the 3 to 6 months pre-SERF ablation. The study catheter was used to deliver an average of 10±5 lesions per case, with an average of 430±295 seconds of radiofrequency time, 122±65 minute of catheter use time, and a procedural duration of 4.3±1.3 hours. Acute procedural success was 97% for eliminating the clinical VT. At average follow-up of 5 months (n=32), device therapies were reduced by 89%. Complications included 2 periprocedural deaths: an embolic mesenteric infarct and cardiogenic shock, 2 mild strokes, and a pericardial effusion treated with pericardiocentesis (n=1). Conclusions: Intramural heated saline needle ablation showed complete acute and satisfactory mid-term control of difficult VTs failing 1 to 5 prior ablations and drug therapy. Further study is warranted to define safety and longer-term efficacy. Registration: URL: https://www.clinicaltrials.gov ; Unique Identifier: NCT03628534 and NCT02994446.
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation
Calkins, Hugh , Hindricks, Gerhard , Cappato, Riccardo , Kim, Young‐Hoon , Aguinaga, Luis, Akar, Joseph G. , Badhwar, Vinay , Camm, A. John , Chen, Peng‐Sheng , Chen, Shih‐Ann , Chung, Mina K. , Nielsen, Jens Cosedis , Curtis, Anne B. , Davies, D. Wyn, Groot, Natasja M.S. de , Duytschaever, Mattias , Edgerton, James R. , Ellenbogen, Kenneth A. , Ernst, Sabine , Fenelon, Guilherme , Gerstenfeld, Edward P. , Haines, David E. , Haïssaguerre, Michel , Jackman, Warren M. , Jalife, José , Kalman, Jonathan M. , Kautzner, Josef , Kottkamp, Hans , Kuck, Karl Heinz, Kumagai, Koichiro , Lee, Richard, Lewalter, Thorsten , Lindsay, Bruce D., Mansour, Moussa , Michaud, Gregory F., Nakagawa, Hiroshi , Natale, Andrea , Okumura, Ken , Packer, Douglas L. , Reynolds, Matthew R. , Sanders, Prashanthan , Scanavacca, Maurício , Schilling, Richard J. , Tondo, Claudio , Tsao, Hsuan-Ming, Verma, Atul , Wilber, David J. , Reviewers:, Document, Paola, Ângelo Amato Vincenzo de , Kistler, Peter M. , Pisani, Cristiano , Raviele, Antonio , Satomi, Kazuhiro , Stiles, Martin K. , Willems, Stephan , Haı̈ssaguerre, Michel , Packer, Douglas, Verma, Atul , Natale, Andrea , Sanders, Prashanthan , Nielsen, Jens C , de Groot, Natasja M S , Saad, Eduardo , Brugada, Josép , Day, John , d'Avila, Andre , Biase, Luigi Di , Ellinor, Patrick T. , Haissaguerre, Michel , Helm, Robert H. , Hylek, Elaine M. , Macle, Laurent , Marchlinski, Francis E. , Michaud, Gregory F. , Nattel, Stanley , Pokushalov, Evgeny A. , Tsao, Hsuan-Ming, Yamane, Teiichi , Reviewers:, Document, Blomström‐Lundqvist, Carina , Lip, Gregory Y H , Peters, Nicholas Simon , Scanavacca, Maurício , Tondo, Claudio , Ernst, Sabine , Ellenbogen, Kenneth A

EP Europace | January 17, 2018 | Volume: 20 | Issue: 1 | Pages: e1-e160

10.1093/europace/eux274 Get It

2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary
Calkins, Hugh , Hindricks, Gerhard , Cappato, Riccardo , Kim, Young‐Hoon , Aguinaga, Luis, Akar, Joseph G. , Badhwar, Vinay , Camm, A. John , Chen, Peng‐Sheng , Chen, Shih‐Ann , Chung, Mina K. , Nielsen, Jens Cosedis , Curtis, Anne B. , Davies, D. Wyn, Groot, Natasja M.S. de , Duytschaever, Mattias , Edgerton, James R. , Ellenbogen, Kenneth A. , Ernst, Sabine , Fenelon, Guilherme , Gerstenfeld, Edward P. , Haines, David E. , Haïssaguerre, Michel , Jackman, Warren M. , Jalife, José , Kalman, Jonathan M. , Kautzner, Josef , Kottkamp, Hans , Kuck, Karl Heinz, Kumagai, Koichiro , Lee, Richard, Lewalter, Thorsten , Lindsay, Bruce D., Mansour, Moussa , Michaud, Gregory F., Nakagawa, Hiroshi , Natale, Andrea , Okumura, Ken , Packer, Douglas L. , Reynolds, Matthew R. , Sanders, Prashanthan , Scanavacca, Maurício , Schilling, Richard J. , Tondo, Claudio , Tsao, Hsuan-Ming, Verma, Atul , Wilber, David J. , Haı̈ssaguerre, Michel , Packer, Douglas, Verma, Atul , Natale, Andrea , Sanders, Prashanthan , Nielsen, Jens C , de Groot, Natasja M S , Saad, Eduardo , Brugada, Josép , Day, John , d'Avila, Andre , Biase, Luigi Di , Ellinor, Patrick T. , Haissaguerre, Michel , Helm, Robert H. , Hylek, Elaine M. , Macle, Laurent , Marchlinski, Francis E. , Michaud, Gregory F. , Nattel, Stanley , Pokushalov, Evgeny A. , Tsao, Hsuan-Ming, Yamane, Teiichi , Scanavacca, Maurício , Tondo, Claudio , Ernst, Sabine , Ellenbogen, Kenneth A

EP Europace | January 5, 2018 | Volume: 20 | Issue: 1 | Pages: 157-208

10.1093/europace/eux275 Get It

Lesion Size and Safety Comparison Between the Novel Flex Tip on the FlexAbility Ablation Catheter and the Solid Tips on the ThermoCool and ThermoCool SF Ablation Catheters
Winterfield, Jeffrey R. , Jensen, James A., GILBERT, THERESE, Natale, Andrea , Packer, Douglas L. , Reddy, Vivek Y. , Mahapatra, Srijoy, Wilber, David J. , Packer, Douglas, Marchlinski, Francis E. , Natale, Andrea , Reddy, Vivek Y

Journal of Cardiovascular Electrophysiology | September 11, 2015 | Volume: 27 | Issue: 1 | Pages: 102-109

10.1111/jce.12835 Get It

Flex Tip Comparative AblationIntroductionNext‐generation catheters have been developed to reduce irrigation volume and preserve power delivery. A novel design uses a flexible tip (FlexAbility™ catheter) that directs flow to the contact surface. Because of recent safety issues with new catheters, we undertook a study in a canine heart with 3 irrigated catheters to compare efficacy and safety.MethodsEndocardial ablation was performed by 2 independent operators in 12 anesthetized canines with the FlexAbility (St. Jude Medical), ThermoCool™ (Biosense Webster), and ThermoCool™ SF (Biosense Webster) catheters. Endocardial RF lesions were delivered with each catheter in all 4 chambers of each animal for 52 ± 16 seconds. Each chamber was randomized to receive ablation from one catheter with recording of safety events. Cardiac pathology was performed with triphenyl tetrazolium chloride stain.ResultsAverage lesion dimensions were not significantly different between the 3 catheters. FlexAbility™ demonstrated a lower risk of steam pops relative to ThermoCool SF (P‐value = 0.013) despite equal mean power and radiofrequency time. High‐temperature generator shutdowns were observed with FlexAbility™ but not with either ThermoCool catheter. High‐temperature shutdowns were associated with larger average impedance drops (28.5 ohms vs. 19 ohms) without compromising lesion size.ConclusionsThe FlexAbility™ tip is safe and effective with no significant difference in lesion sizes compared to both standard ThermoCool and ThermoCool SF. FlexAbility™ has a significantly lower risk of steam pops compared to ThermoCool SF in a beating heart as defined predominantly by an abrupt rise of impedance.