AbstractAimsThe TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) clinical trial compared clinical outcomes using a contact force (CF) sensing ablation catheter (TactiCath) with a catheter that lacked CF measurement. This analysis links recorded events in the TOCCASTAR study and a large claims database, IBM MarketScan®, to determine the economic impact of using CF sensing during atrial fibrillation (AF) ablation.Methods and ResultsClinical events including repeat ablation, use of antiarrhythmic drugs, hospitalization, perforation, pericarditis, pneumothorax, pulmonary edema, pulmonary vein stenosis, tamponade, and vascular access complications were adjudicated in the year after ablation. CF was characterized as optimal if greater than or equal to 90% lesion was performed with greater than or equal to 10 g of CF. A probabilistic 1:1 linkage was created for subjects in MarketScan® with the same events in the year after ablation, and the cost was evaluated over 10 000 iterations. Of the 279 subjects in TOCCASTAR, 145 were ablated using CF (57% with optimal CF), and 134 were ablated without CF. In the MarketScan® cohort, 9811 subjects who underwent AF ablation were used to determine events and costs. For subjects ablated with optimal CF, total cost was $19 271 ± 3705 in the year after ablation. For ablation lacking CF measurement, cost was $22 673 ± 3079 (difference of $3402, P < .001). In 73% of simulations, optimal CF was associated with lower cost in the year after ablation.ConclusionCompared to ablation without CF, there was a decrease in healthcare cost of $3402 per subject in the first year after the procedure when optimal CF was used.
Lesion Size and Safety Comparison Between the Novel Flex Tip on the FlexAbility Ablation Catheter and the Solid Tips on the ThermoCool and ThermoCool SF Ablation Catheters
Flex Tip Comparative AblationIntroductionNext‐generation catheters have been developed to reduce irrigation volume and preserve power delivery. A novel design uses a flexible tip (FlexAbility™ catheter) that directs flow to the contact surface. Because of recent safety issues with new catheters, we undertook a study in a canine heart with 3 irrigated catheters to compare efficacy and safety.MethodsEndocardial ablation was performed by 2 independent operators in 12 anesthetized canines with the FlexAbility (St. Jude Medical), ThermoCool™ (Biosense Webster), and ThermoCool™ SF (Biosense Webster) catheters. Endocardial RF lesions were delivered with each catheter in all 4 chambers of each animal for 52 ± 16 seconds. Each chamber was randomized to receive ablation from one catheter with recording of safety events. Cardiac pathology was performed with triphenyl tetrazolium chloride stain.ResultsAverage lesion dimensions were not significantly different between the 3 catheters. FlexAbility™ demonstrated a lower risk of steam pops relative to ThermoCool SF (P‐value = 0.013) despite equal mean power and radiofrequency time. High‐temperature generator shutdowns were observed with FlexAbility™ but not with either ThermoCool catheter. High‐temperature shutdowns were associated with larger average impedance drops (28.5 ohms vs. 19 ohms) without compromising lesion size.ConclusionsThe FlexAbility™ tip is safe and effective with no significant difference in lesion sizes compared to both standard ThermoCool and ThermoCool SF. FlexAbility™ has a significantly lower risk of steam pops compared to ThermoCool SF in a beating heart as defined predominantly by an abrupt rise of impedance.
Impact of Transforming Growth Factor-β1 on Atrioventricular Node Conduction Modification by Injected Autologous Fibroblasts in the Canine Heart
Background— Atrioventricular (AV) nodal ablation for management of atrial fibrillation (AF) is irreversible and requires permanent pacemaker implantation. We hypothesized that as an alternative, implantation of autologous fibroblasts in the perinodal region would focally modify AV nodal conduction and that this modulation would be enhanced by pretreatment with transforming growth factor-β1 (TGF-β1), a stimulant of fibroblasts. Methods and Results— Skin biopsies were taken from 12 mongrel dogs, and derived fibroblasts were dissociated and grown in culture for 2 weeks. Multiple injections (0.25 mL) were made through an 8F NOGA catheter along the fast/slow AV nodal pathways as guided by an electroanatomic mapping system. Seven dogs received fibroblasts alone (1×10 6 cells/mL), 7 dogs received TGF-β1 (5 μg), 4 dogs received fibroblasts and TGF-β1 (1×10 6 cells/mL+5 μg), and 4 dogs received saline only. AV node function was assessed at baseline and after 4 weeks. Saline (80 mL) with assigned therapy (0.25 mL per injection) was injected into the peri-AV nodal region in each dog. At baseline, the AH interval (66±3 ms) and the average RR interval (331±17 ms) in pacing-induced AF were similar in each cohort. The increase in AH interval in normal sinus rhythm was longer after fibroblast (23±4 versus 5±5 ms; P =0.05) and fibroblast plus TGF-β1 (50±5 versus 5±5 ms; P <0.001) injections than with saline alone, with similar findings during high right atrium and distal coronary sinus pacing. The AH interval was not significantly increased after TGF-β1 injections. The AH interval was significantly longer after fibroblast plus TGF-β1 injections than with either therapy (TGF-β1 or fibroblasts) alone. The RR interval during AF was increased in dogs that received fibroblasts alone (110±36 versus −41±34 ms) and to a greater extent with the addition of TGF-β1 (294±108 versus −41±34 ms). No AV block was seen in any cohort at 4 weeks. Labeled fibroblasts that expressed vimentin were identified in all dogs that received cell injections at 4 weeks. Conclusions— AV nodal modification can be achieved with injected fibroblasts without the creation of AV block. The effect on AV node conduction is substantially enhanced by pretreatment of fibroblasts with TGF-β1. These data have therapeutic potential for the management of rapid ventricular rate during AF without pacemaker implantation.