Abstract 55: Use of a Novel Electrogram Filter to Visualise the Conduction Tissue Signals in the Ventricle in Sinus Rhythm and Arrhythmia: Canine Studies
Padmanabhan, Deepak , Witt, Chance M. , Sugrue, Alan , Killu, Ammar M. , Naksuk, Niyada , Ladewig, Dorothy J., Powers, Joanne, Suddendorf, Scott H., DeSimone, Christopher V. , Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.55 Get It

Background: Conduction tissue in the ventricles is closely intertwined with myocardium. Owing to high velocity of conduction, there is near simultaneous activation , making it difficult to discern. Restricted sampling rates and limited dynamic range make real time signal processing challenging for these signals in routine recording systems. Objectives: We aimed to use novel signal processing techniques in a new system to isolate the conduction tissue signals from the rest of the myocardial activation. Methods: We used the PURE-EP™ (BioSig Technologies, MN) signal processing system to record endocardial and epicardial signals from 6 anesthetized canines in an acute study setting. A novel filter based on proprietary algorithms to isolate the high frequency signal was applied at sites where the electrogram signals were thought to have a conduction tissue component to them. . In addition, ventricular fibrillation (VF) was induced at the end of the experiment and signals were then recorded from the endocardium and the conduction system. Results: This filter was successfully able to isolate conduction tissue signals in the myocardium from those of the ventricular muscle. It did over sense atrial signals at the basal left ventricular septum owing to the high frequency components of the atrial signal at this location. When applied to epicardial signals, it did not pick up any conduction tissue signals. In VF, we could discern signals originating from the conduction system endocardially. (Figure 1) Conclusions: This filter can isolate conduction tissue signals from those of the myocardium and may prove to be a useful adjunct in mapping arrhythmias originating near the conduction system.
Abstract 371: Assessment of Catheter Position Above or Below the Aortic Valve by Evaluation of Characteristics of the Local Electro Gram: an Acute Canine Study
Pa, Deepak, Witt, Chance M. , Sugrue, Alan , Suddendorf, Scott H., Powers, Joanne, Ladewig, Dejae, Drakulic, Budimir , Foxall, Thomas, LADEWIG, DEJAE J., Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.371 Get It

Background: Ablation in the sinuses of Valsalva (SoV) within the aorta is fraught with risk, owing to the proximity of the coronary arteries. Assessment of catheter tip position is not very easy at this location owing to complex local anatomy and poor images from available modalities. Objectives: We propose the use of novel local unipolar electrogram characteristics using a new signal recording system to guide the assessment of catheter tip position in this region. Methods: We recorded unipolar signals from above the SoV, within the coronaries and below the SoV using the PURE-EP™ (BioSig Technologies, MN) signal processing system in 4 anesthetized canines in the setting of an acute study. We used fluoroscopy, intracardiac echocardiography and angiography for confirmation of the position of the catheter tip. We recorded changes in the signals when transitioning between (1) the coronary arteries and the SoV and (2) the SoV and below the SoV. Results: The unipolar signal showed a negative current of injury (COI) when the catheter tip was present in the SoV, whereas within the coronary artery or below the SoV, the COI was positive. We propose that the difference in the distribution of ventricular muscle below and above the SoV is responsible for this phenomenon. These changes in the COI were noted immediately when transitioning from one location to another and were present reproducibly in all the dogs. ( Figure 1 ) Conclusions: Analysis of the changes on the local electrogram can provide information about the location of the catheter tip which could prove critical in saving lives.
Abstract 60: Inducible Arrythmogenicity of Direct Current Electroporation Ablation: Insight from a Series of Acute Canine Studies
Sugrue, Alan , Witt, Chance M. , Padnanabhan, Deepak, Killu, Ammar M. , Naksuk, Niyada , DeSimone, Christopher V. , Kapa, Suraj , Asirvatham, Samuel J.

Circulation Research | July 3, 2021 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.60 Get It

Background: The use of direct current electroporation has the potential for significant utility because of its non-thermal approach to tissue destruction. However, the fear of inducibility of cardiac arrhythmias (particular ventricular fibrillation) when using electroporation remains of concern due to membrane poration and ion flux during periods of vulnerability occurring in ventricular repolarization. Objectives: Critically examine the incidence of arrhythmias in a series of acute canine studies to retrospectively determine cause and safe electoporative dosing margins. Methods: We performed electroporation ablation in 6 acute canine studies. These were experimental studies performed at sites critical in arrhytmogenesis. Sites included the pulmonary veins, left atrial appendage, superior vena cavae, right atrium and ventricle. Electroporation was delivered using an ECG gating algorithm so that QRS complexes are tagged and direct current energy is not delivered during the vulnerable portion of the T wave. Results: In 6 acute canine experiments, we delivered a total of 62 electroporation applications for ablation purposes. The average electroporation dosage delivered involved an average of 1427 Volts (range 750-3000 V), Pulse length of 100 ms, and number of pulses of 20.2 (range 10-100). AF was induced in 27.4% of electroporiatve applications. Atrial flutter/tachycardia occurred in 8.1%. VF occurred in only one application at a location of the left superior pulmonary vein. Conclusion: These data suggest that induction of VF is relatively uncommon with ECG gating and highlight its importance when using this modality. However, the induction of AF occurs with higher frequency. The actual mechanism as to why this occurs requires further systematic study.
Abstract 12776: Long Term Mortality With Right Ventricular Apical Versus Septal Pacing
Witt, Chance M. , Lenz, Charles J., Shih, Henry, Ebrille, Elisa , Rosenbaum, Andrew , Aung, Htin , Zyl, Martin van , Manocha, Kevin K. , Deshmukh, Abhishek , Hodge, David O. , Aung, Htin, Asirvatham, Samuel J. , McLeod, Christopher J.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12776 Get It

Introduction: Right ventricular apical (RVA) pacing appears to have detrimental effects on cardiac function and long term outcomes. Right ventricular non-apical (RVNA) pacing, especially in the septal position, has been postulated as an alternative that may lead to less morbidity and mortality. Prior studies have shown conflicting results and been limited by small numbers and short follow-up. We aimed to determine if right ventricular septal lead position was associated with a reduction in long-term mortality compared to RVA lead position. Methods: Patients who underwent dual-chamber pacemaker implantation from 2004 through 2013 were evaluated for right ventricular lead position based on chest radiographs. Lead positions were divided in to apical or non-apical. Non-apical lead positions were subdivided to isolate a septal lead position group. Mortality was compared between these groups. Results: During the study period, 3456 patients underwent dual-chamber pacemaker placement and had images appropriate for lead position evaluation. The group was 53.5% male with a mean age of 74 ± 13 years. RVNA lead position was found in 976 (28.2%) patients, including 243 (7.0%) with a septal position. There was no significant difference in age or prior heart failure diagnosis between groups. Kaplan-Meier survival analysis did not reveal a significant difference in mortality between patients with RVA versus RVNA lead position during 5 year follow-up (p = 0.82). However, septal lead position was associated with a significantly lower mortality compared with RVA position (p = 0.03) (figure). Conclusions: Right ventricular septal lead position is associated with a lower long-term mortality than RVA lead position. This has substantial implications regarding the preferred site for ventricular pacing lead placement.
Sinus rhythm heart rate increase after atrial fibrillation ablation is associated with lower risk of arrhythmia recurrence
Killu, Ammar M. , Witt, Chance M. , Sugrue, Alan , Vaidya, Vaibhav R. , Monahan, Kristi H. , Lenz, Charles J., Yogeswaran, Vidhushei , Sun, Philip Y. , Hodge, David O. , Friedman, Paul A. , Packer, Douglas L. , Asirvatham, Samuel J. , Sugrue, Alan M, Vaidya, Vaibhav , Barnes, Stephanie, Friedman, Paul A , Asirvatham, Samuel J , Sun, Philip , Barnes, Stephanie

Pacing and Clinical Electrophysiology | February 17, 2021 | Volume: 44 | Issue: 4 | Pages: 651-656

10.1111/pace.14197 Get It

AbstractBackgroundPulmonary vein isolation (PVI) with autonomic modulation may be more successful than PVI alone for atrial fibrillation (AF) ablation and may be signaled by changes in sinus rhythm heart rate (HR) post ablation. We sought to determine if a change in sinus rhythm HR predicted AF recurrence post PVI.MethodsPatients who underwent AF ablation from 2000 to 2011 were included if sinus rhythm was noted on ECG within 90 days pre and 7 days post ablation. Basic ECG interval and HR changes were analyzed and outcomes determined.ResultsA total of 1152 patients were identified (74.3% male, mean age 57 ± 11 years). Mean AF duration was 5.2 ± 5.3 years. Paroxysmal AF was noted in 712 (61.8%) of the patients. Mean EF was 61% ± 6%. Sinus rhythm HR was 61 ± 11 pre‐ablation and 76 ± 13 bpm post‐ablation (27% ± 24% increase, p < .001). The ability of relative HR change post‐ablation to predict AF recurrence was borderline (hazard ratio 0.65 [0.41–1.01], p = .067). With patients separated into quartiles based on the relative HR change, the upper quartile with the largest relative increase in HR had a significantly lower rate of AF recurrence compared to the lowest quartile following multi variable modeling (p = .038). There were significant changes in PR (171 ± 28 to 167 ± 30 ms) and QTc (424 ± 25 to 434 ± 29 ms) intervals (both p < .001) but these were not predictive of outcome.ConclusionRelative changes in HR post AF ablation correlates with AF recurrence. Further prospective studies are needed to confirm this relationship.
Efficacy of medical and ablation therapy for inappropriate sinus tachycardia: A single‐center experience
Shabtaie, Samuel A. , Witt, Chance M. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | February 10, 2021 | Volume: 32 | Issue: 4 | Pages: 1053-1061

10.1111/jce.14942 Get It

AbstractBackgroundEffective therapy for inappropriate sinus tachycardia (IST) remains challenging with high rates of treatment failure and symptom recurrence. It is uncertain how effective pharmacotherapy and procedural therapy are long‐term, with poor response to medical therapy in general.MethodsWe retrospectively reviewed all patients with the diagnosis of IST at a tertiary academic medical center from 1998 to 2018. We extracted data related to prescribing patterns and symptom response to medical therapy and sinus node modification (SNM), assessing efficacy and periprocedural complication rates.ResultsA total of 305 patients with a formal diagnosis of IST were identified, with 259 (84.9%) receiving at least one prescription medication related to the condition. Beta‐blockers were the most commonly used medication (n = 245), with a majority of patients reporting no change or worsening of symptoms, and poor response was seen to other medication classes. Improvement was seen significantly more often with ivabradine than beta blockers, though the sample size was limited (p = .003). Fifty‐five patients (18.0% of all IST patients), mean age 32.0 ± 9.1 years, underwent a SNM procedure, with an average of 1.8 ± 0.9 procedures per patient. Acute symptomatic improvement (<6 months) was seen in 58.2% of patients. Long‐term complete resolution of symptoms was seen in 5.5% of patients, modest improvement in 29.1%, and no long‐term benefit was seen in 65.5% of patients.ConclusionsAmong all medical therapies, there were high rates of treatment failure or symptom worsening in over three‐quarters of patients in our study. Ivabradine was most beneficial, though the sample size was small. While most patients receiving SNM ablation for IST perceive an acute symptomatic improvement, almost two‐thirds of patients have no long‐term improvement, and resolution of symptoms is quite rare. AV node ablation with pacemaker implantation following lack of response to SNM offered increased success, though the sample size was limited.
Incremental benefit of a novel signal recording system during mapping and ablation
Padmanabhan, Deepak , Sugrue, Alan , Vaidya, Vaibhav R. , Witt, Chance M. , Yasin, Omar , Naksuk, Niyada , Killu, Ammar M. , Foxall, T., Drakulic, Budimir , Venkatachalam, K, Asirvatham, Samuel J. , Vaidya, Vaibhav, Witt, Chance, Killu, Ammar, Venkatachalam, Kalapathi Lakshminarayana, Asirvatham, Samuel J , Foxall, Thomas

EP Europace | August 10, 2020 | Volume: 23 | Issue: 1 | Pages: 130-138

10.1093/europace/euaa194 Get It

Abstract Aims Current electrophysiology signal recording and mapping systems have limited dynamic range (DR) and bandwidth, which causes loss of valuable information during acquisition of cardiac signals. We evaluated a novel advanced signal processing platform with the objective to obtain and assess additional information of clinical importance. Methods and results Over 10 canines, we compared intracardiac recordings within all cardiac chambers, in various rhythms, in pacing and during radiofrequency (RF) ablation across two platforms; a conventional system and the PURE EP™ [(PEP); Bio Sig Technologies, Inc., Los Angeles, CA, USA]. Recording cardiac signals with varying amplitudes were consistently and reproducibly observed, without loss of detail or introduction of artefact. Further the amplitude of current of injury (COI) on the unipolar signals correlated with the instantaneous contact force (CF) recorded on the sensing catheter in all the animals (r2 = 0.94 in ventricle). The maximum change in the unipolar COI correlated with the change in local electrogram amplitude during non-irrigated RF ablation (r2 = 0.61 in atrium). Reduction in artefact attributable to pacing (20 sites) and noise during ablation (48 sites) was present on the PEP system. Within the PEP system, simultaneous display of identical signals, filtered differently, aided the visualization of discrete conduction tissue signals. Conclusion Compared to current system, the PEP system provided incremental information including identifying conduction tissue signals, estimates of CF and a surrogate for lesion formation. This novel signal processing platform with increased DR and minimal front-end filtering may be useful in clinical practice.
Left Bundle Branch Block
Tan, Nicholas Y. , Witt, Chance M. , Oh, Jae K. , Cha, Yong‐Mei

Circulation: Arrhythmia and Electrophysiology | March 18, 2020 | Volume: 13 | Issue: 4 | Pages: No page available

10.1161/circep.119.008239 Get It

Left bundle branch block may be due to conduction system degeneration or a reflection of myocardial pathology. Left bundle branch block may also develop following aortic valve disease or cardiac procedures. Patients with heart failure with reduced ejection fraction and left bundle branch block may respond positively to cardiac resynchronization therapy. Lead placement via the coronary sinus is the mainstay approach of cardiac resynchronization therapy. However, other options, including physiological pacing, are being explored. In this review, we summarize the salient pathophysiologic and clinical aspects of left bundle branch block, as well as current and future strategies for management.
Natural history and clinical outcomes of inappropriate sinus tachycardia
Shabtaie, Samuel A. , Witt, Chance M. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | November 21, 2019 | Volume: 31 | Issue: 1 | Pages: 137-143

10.1111/jce.14288 Get It

AbstractBackgroundLimited data are available regarding the demographics, disease associations, and long‐term prognosis of patients with inappropriate sinus tachycardia (IST).ObjectiveTo establish epidemiologic data for patients with IST, including symptom onset, comorbid disease, and long‐term outcomes.MethodsWe retrospectively reviewed all patients with an IST diagnosis at the Mayo Clinic (Rochester, MN) during a 20‐year period (1998‐2018). We extracted demographic data and clinical outcomes compared to an age and gender‐matched control group with atrioventricular nodal reentry tachycardia (AVNRT).ResultsWithin the study period, a total of 305 patients with IST were identified (mean follow‐up 3.5 years) with 92.1% female and mean age 33.2 ± 11.2 years. The most frequently identified circumstances triggering the condition included pregnancy (7.9%) and infectious illness (5.9%) while the most common comorbid conditions were depression (25.6%) and anxiety (24.6%). At diagnosis, the mean left ventricular ejection fraction (LVEF) was 62.3 ± 6.2%, with 77 patients having follow‐up echocardiographic data. No significant difference in LVEF was seen after a mean 4.9 ± 4.3‐year follow‐up (baseline LVEF 59.8 ± 10.7% vs subsequent 61.4 ± 8.1%; P = .2971). Two deaths occurred within the study period, with one related to myocardial infarction and the other noncardiac; compared to an age and gender‐matched AVNRT control group there was no excess mortality during the follow‐up period.ConclusionsIn our study cohort, IST predominately affects young females with structurally normal hearts and modest coexistent psychiatric disease. In most cases of IST, a major event occurring just before or at the time of diagnosis could not be identified, although nearly 8% of patients first noted symptoms during or shortly after pregnancy. In our cohort, there was no evidence of cardiomyopathy or mortality related to IST.