Abstract Aims Current electrophysiology signal recording and mapping systems have limited dynamic range (DR) and bandwidth, which causes loss of valuable information during acquisition of cardiac signals. We evaluated a novel advanced signal processing platform with the objective to obtain and assess additional information of clinical importance. Methods and results Over 10 canines, we compared intracardiac recordings within all cardiac chambers, in various rhythms, in pacing and during radiofrequency (RF) ablation across two platforms; a conventional system and the PURE EP™ [(PEP); Bio Sig Technologies, Inc., Los Angeles, CA, USA]. Recording cardiac signals with varying amplitudes were consistently and reproducibly observed, without loss of detail or introduction of artefact. Further the amplitude of current of injury (COI) on the unipolar signals correlated with the instantaneous contact force (CF) recorded on the sensing catheter in all the animals (r2 = 0.94 in ventricle). The maximum change in the unipolar COI correlated with the change in local electrogram amplitude during non-irrigated RF ablation (r2 = 0.61 in atrium). Reduction in artefact attributable to pacing (20 sites) and noise during ablation (48 sites) was present on the PEP system. Within the PEP system, simultaneous display of identical signals, filtered differently, aided the visualization of discrete conduction tissue signals. Conclusion Compared to current system, the PEP system provided incremental information including identifying conduction tissue signals, estimates of CF and a surrogate for lesion formation. This novel signal processing platform with increased DR and minimal front-end filtering may be useful in clinical practice.
Background— People with heart failure and preserved ejection fraction develop increases in left ventricular (LV) end-diastolic pressures during exercise that contribute to dyspnea. In normal open-chest animal preparations, the pericardium restrains LV filling when central blood volume increases. We hypothesized that resection of the pericardium using a minimally invasive epicardial approach would mitigate the increase in LV end-diastolic pressure that develops during volume loading in normal and diseased hearts with the chest intact. Methods and Results— Invasive hemodynamic assessment was performed at baseline and after saline load before and after pericardial resection in normal canines with open (n=3) and closed chest (n=5) and in a pig model with features of human heart failure and preserved ejection fraction with sternum intact (n=4). In closed-chest animals, pericardiotomy was performed using a novel subxiphoid procedure. In both experimental preparations of normal dogs, pericardiotomy blunted the increase in LV end-diastolic pressure with saline infusion, while enhancing the saline-mediated increase in LV end-diastolic volume. With chest intact in the pig model, percutaneous pericardial resection again blunted the increase in LV end-diastolic pressure secondary to volume expansion (+4±3 versus +13±5 mm Hg; P =0.014), while enhancing the saline-mediated increase in LV end-diastolic volume (+17±1 versus +10±2 mL; P =0.016). Conclusions— This proof of concept study demonstrates that pericardial resection through a minimally invasive percutaneous approach mitigates the elevation in LV filling pressures with volume loading in both normal animals and a pig model with diastolic dysfunction. Further study is warranted to determine whether this method is safe and produces similar acute and chronic hemodynamic benefits in people with heart failure and preserved ejection fraction.