Back to Authors

Giardi, Davide

0000-0001-9780-6403

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Jacksonville, Florida, United States.

Citations 3

Perceived Age in Patients Exposed to Distinct UV Indexes: A Systematic Review
Ávila, Francisco R. , Carter, Rickey E. , Giardi, Davide , Guliyeva, Günel , Torres‐Guzman, Ricardo A. , Maita, Karla C. , Bruce, Charles J. , Giardi, Davide , Torres, Ricardo A , Forte, Antonio Jorge , Carter, Rickey E , Avila, Francisco R , McLeod, Christopher J. , Forte, Antonio J.

Indian Journal of Plastic Surgery | December 22, 2022 | Volume: 56 | Issue: 02 | Pages: 103-111

10.1055/s-0042-1759696 Get It

AbstractPhotodamage is caused by chronic sun exposure and ultraviolet radiation and presents as wrinkles, sagging, and pigmented spots. An increase in the ultraviolet index can increase a person's perceived age by worsening skin photodamage. However, since the ultraviolet index varies considerably between geographical regions, perceived age might vary substantially among them. This review aims to describe the differences in chronological and perceived age in regions of the world with different ultraviolet indexes. A literature search of three databases was conducted for studies analyzing perceived age and its relationship to sun exposure. Ultraviolet indexes from the included studies were retrieved from the National Weather Service and the Tropospheric Emission Monitoring Internet Service. Out of 104 studies, seven fulfilled the inclusion criteria. Overall, 3,352 patients were evaluated for perceived age. All studies found that patients with the highest daily sun exposures had the highest perceived ages for their chronological age (p < 0.05). People with high sun exposure behaviors living in regions with high ultraviolet indexes will look significantly older than same-aged peers living in lower ultraviolet index regions.
Atrial Arrhythmia Ablation in Patients With D-Transposition of the Great Arteries and Atrial Switch
Chiriac, Anca , Cheema, Kamal Preet, Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Perez-Downes, Julio , Umadat, Goyal , Hodge, David O. , Phillips, Sabrina D. , Madhavan, Malini , Asirvatham, Samuel J. , Cheema, Kamal P, Espinosa, Samantha M, Perez-Downes, Julio C , McLeod, Christopher J , Asirvatham, Samuel J , Giardi, Davide , McLeod, Christopher J.

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010546 Get It

Background: Patients with D-transposition of the great arteries and atrial switch have a high incidence of atrial arrhythmias. We sought to analyze the arrhythmia substrate, ablation strategies, and outcomes for catheter ablation in this population. Methods: An in-depth analysis of all clinical and procedural data in patients with D-transposition of the great arteries, atrial baffles, and atrial arrhythmia ablation was performed. Results: A cohort of 32 patients (72% male, mean age 38±7 years) underwent ablation for non-AV nodal reentrant tachycardia atrial arrhythmias, and 4 patients underwent AV nodal reentrant tachycardia ablation. Cavotricuspid isthmus flutter (CTI-flutter) was the most common arrhythmia, encountered in 75% of patients, followed by scar-related intraatrial reentrant tachycardia (non-CTI intraatrial reentrant tachycardia, 53%) and focal atrial tachycardia (focal atrial tachycardia, 6%). Among the 32 patients, 26 underwent 31 procedures at our institution. For patients with prior outside intervention, the index ablation at our institution revealed CTI-dependent flutter in 3/5 cases. However, redo ablation after an index ablation with demonstrated bidirectional CTI block revealed different/new arrhythmia substrates (80% non-CTI intraatrial reentrant tachycardia, 40% focal atrial tachycardia). Achieving bidirectional block across the CTI often required ablating on both sides of the baffle (retroaortic access, 81%; using a baffle leak, 11.5%; or transbaffle puncture, 7.7%). Combined approaches were necessary in 19% to reach the critical tissue. Acute procedural success was 81%, and recurrence was documented in 58% of patients. Despite recurrence, clinical arrhythmia burden was significantly reduced post-ablation ( P <0.001), with rare episodes, amenable to antiarrhythmic therapy. Redo ablation was required in 5 (19%) patients and uncovered new arrhythmia substrates. AV nodal reentrant tachycardia ablation also required transbaffle approaches in 3/4 patients. Conclusions: CTI-dependent flutter was the most common arrhythmia in patients with Dextro-Transposition of the Great Arteries and atrial switch. Transbaffle approaches were often necessary, and, provided that bidirectional CTI block was achieved at the index ablation, late recurrence was due to different arrhythmia mechanisms. Despite recurrence, ablation was associated with significant clinical improvement.
Accuracy of Wearable Sensor Technology in Hand Goniometry: A Systematic Review
Ávila, Francisco R. , Carter, Rickey E. , Giardi, Davide , Guliyeva, Günel , Forte, Antonio J. , Bruce, Charles J. , Giardi, Davide , Forte, Antonio Jorge , Carter, Rickey E , Avila, Francisco R , McLeod, Christopher J.

HAND | May 25, 2021 | Volume: 18 | Issue: 2 | Pages: 340-348

10.1177/15589447211014606 Get It

Background Wearable devices and sensor technology provide objective, unbiased range of motion measurements that help health care professionals overcome the hindrances of protractor-based goniometry. This review aims to analyze the accuracy of existing wearable sensor technologies for hand range of motion measurement and identify the most accurate one. Methods We performed a systematic review by searching PubMed, CINAHL, and Embase for studies evaluating wearable sensor technology in hand range of motion assessment. Keywords used for the inquiry were related to wearable devices and hand goniometry. Results Of the 71 studies, 11 met the inclusion criteria. Ten studies evaluated gloves and 1 evaluated a wristband. The most common types of sensors used were bend sensors, followed by inertial sensors, Hall effect sensors, and magnetometers. Most studies compared wearable devices with manual goniometry, achieving optimal accuracy. Although most of the devices reached adequate levels of measurement error, accuracy evaluation in the reviewed studies might be subject to bias owing to the use of poorly reliable measurement techniques for comparison of the devices. Conclusion Gloves using inertial sensors were the most accurate. Future studies should use different comparison techniques, such as infrared camera–based goniometry or virtual motion tracking, to evaluate the performance of wearable devices.