Unnecessary ED visits and transfers to hand clinics raise treatment costs and patient burden at trauma centers. In the present COVID-19 pandemic, needless transfers can increase patients’ risk of viral exposure. Therefore, this review analyzes different aspects of the remote diagnosis and triage of traumatic hand injuries. The most common file was photography, with the most common devices being cell phone cameras. Treatment, triage, diagnosis, cost, and time outcomes were assessed, showing concordance between teleconsultation and face-to-face patient evaluations. We conclude that photography and video consultations are feasible surrogates for ED visits in patients with traumatic hand injuries. These technologies should be leveraged to decrease treatment costs and potentially decrease the time to definitive treatment after initial evaluation.
13-Year Analysis of Gender Disparity in Peer Reviewed Burn Literature
Abstract Women are less likely to be senior authors, invited to write in scientific journals, and to be cited in high impact journals. The aim of this study was to investigate trends in authorship and gender differences in peer-reviewed burn literature over 13 years. We performed a retrospective analysis of original research articles published from January 2009 to September 2021 in three burn journals. A gender determination application was used to categorize the gender of the first and senior author. Of the 3,908 articles analyzed, 42.5% had a woman first author and 27.6% had a woman senior author. We identified 2,029 unique senior authors, 29.0% of whom were women. Woman senior authorship was associated with increased odds of woman first authorship [OR=2.31 (95% CI 2.00, 2.67); p<0.001]. The percentage of papers with a woman senior author increased from 17.8% in 2009 to 35.7% in 2021. If this 1.0% (95% CI: 0.50 – 1.51%) linear trend increase per year in woman senior authorship continues, we will expect to see equal proportions of woman and man senior authors in the included journals starting in 2037. The field of burn care is far from reaching gender parity with respect to authorship of peer-reviewed publications. Supporting and encouraging gender concordant and discordant first:last authorship dyads in mentorship as well as redistributing obligations that may detract from authorship opportunities are potential ways to improve parity in authorship and academia.
Perceived Age in Patients Exposed to Distinct UV Indexes: A Systematic Review
AbstractPhotodamage is caused by chronic sun exposure and ultraviolet radiation and presents as wrinkles, sagging, and pigmented spots. An increase in the ultraviolet index can increase a person's perceived age by worsening skin photodamage. However, since the ultraviolet index varies considerably between geographical regions, perceived age might vary substantially among them. This review aims to describe the differences in chronological and perceived age in regions of the world with different ultraviolet indexes. A literature search of three databases was conducted for studies analyzing perceived age and its relationship to sun exposure. Ultraviolet indexes from the included studies were retrieved from the National Weather Service and the Tropospheric Emission Monitoring Internet Service. Out of 104 studies, seven fulfilled the inclusion criteria. Overall, 3,352 patients were evaluated for perceived age. All studies found that patients with the highest daily sun exposures had the highest perceived ages for their chronological age (p < 0.05). People with high sun exposure behaviors living in regions with high ultraviolet indexes will look significantly older than same-aged peers living in lower ultraviolet index regions.
Reconstruction of Large Soft Tissue Defects in the Distal Lower Extremity: Free Chain-Linked Bilateral Anterolateral Thigh Perforator Flaps versus Extended Latissimus Dorsi Musculocutaneous Flaps
Background: Reconstruction of the large soft-tissue defects in the lower extremity still constitutes a challenge for plastic surgeons. This retrospective study was conducted to compare the surgical and clinical outcomes of the chain-linked bilateral anterolateral thigh perforator flaps and extended latissimus dorsi musculocutaneous flap in the reconstruction of the large soft tissue defects of the lower extremity. Methods: From January 2012 to December 2021, 34 patients aged between 20 and 66 years received chain-linked bilateral anterolateral thigh perforator flaps (15 cases) or extended latissimus dorsi musculocutaneous flaps (19 cases) for the reconstruction of extensive soft-tissue defects in the lower extremity. The two groups were homogeneous in terms of age, etiology, comorbidities, and flap area. In addition, the intraoperative data, outcomes, complications, and long-term follow-up results were collected and analyzed. Results: The extended latissimus dorsi musculocutaneous flap group had a shorter operation time (271.8 ± 59.5 min vs. 429.6 ± 51.9 min), harvest time (58.9 ± 24.8 min vs. 152.7 ± 41.4 min), and anastomosis time (27.2 ± 10.4 min vs. 53.7 ± 8.1 min) than the chain-linked bilateral anterolateral thigh perforator flaps group (p < 0.05). Based on patient self-assessment, the donor site temporary muscle weakness in the extended latissimus dorsi musculocutaneous flap group was significantly more than that in the chain-linked bilateral anterolateral thigh perforator flaps group (p < 0.05). Conclusion: Both methods can repair large defects and restore the function of the injured limbs at a single stage. However, considering the operation time and flap-harvesting time, the authors recommend the extended latissimus dorsi musculocutaneous flap, especially for those who cannot tolerate a prolonged surgery.
766 12-year Analysis of Gender Disparity in Authorship of Peer-Reviewed Burn and Wound Care Literature
Abstract Introduction The importance of gender equity and gender representation in academic publications has long been emphasized in medicine. It has been established that women represent a smaller proportion of primary and senior authors in high-impact medical journals than men and that original research articles written by women as primary and senior authors are less frequently sited than those authored by men. Currently, there is limited data evaluating whether this gender bias is present in plastic surgery and burn publications. We used bibliometric analysis of original research publications to analyze gender bias against women in one burn journal. Methods Using the journal, Burns, we conducted a bibliometric analysis of research publications from 2009 to 2020. A gender determining application was used to characterize the gender of the first and senior author. Ratios of male:male, female:male, male:female, and female:female were obtained and analyzed. Results Of the 1677 publications included, 40% have female first authors and 25.5% had female senior authors. Male:male authorships had the highest number of publications. Female:female authorship had the lowest number of publications of all the other ratios from 2009-2012, however there was a steep increase in 2013 in which male:female authorship had the lowest number of publications. Male senior authorship was associated with 2.9-fold increase in male first authorship [OR=2.99(95% CI 2.39, 3.76); p < 0.0001). Conclusions Female representation in senior authorship positions in burn and wound care publications is increasing, however is still far from reaching gender parity. By analyzing authorship ratios by gender, we recommend a new way to evaluate gender disparity in burn and wound care academia.
Use of adipose-derived stem cells in lymphatic tissue engineering and regeneration
The potential to differentiate into different cell lines, added to the easy and cost-effective method of extraction, makes adipose-derived stem cells (ADSCs) an object of interest in lymphedema treatment. Our study’s goal was to conduct a comprehensive systematic review of the use of ADSCs in lymphatic tissue engineering and regeneration. On July 23, 2019, using PubMed/MEDLINE, Cochrane Clinical Answers, Cochrane Central Register of Controlled Trials, and Embase databases, we conducted a systematic review of published literature on the use of ADSCs in lymphatic tissue engineering and regeneration. There were no language or time frame limitations, and the following search strategy was applied: ((Adipose stem cell) OR Adipose-derived stem cell)) AND ((Lymphedema) OR Breast Cancer Lymphedema). Only original research manuscripts were included. Fourteen studies fulfilled the inclusion criteria. Eleven studies were experimental (in vitro or in vivo in animals), and only three were clinical. Publications on the topic demonstrated that ADSCs promote lymphangiogenesis, and its effect could be enhanced by modulation of vascular endothelial growth factor-C, interleukin-7, prospero homeobox protein 1, and transforming growth factor-β1. Pilot clinical studies included 11 patients with breast cancer-related lymphedema, and no significant side effects were present at 12-month follow-up. Literature on the use of ADSCs in lymphatic tissue engineering and regeneration demonstrated promising data. Clinical evidence is still in its infancy, but the scientific community agrees that ADSCs can be useful in regenerative lymphangiogenesis. Data collected in this review indicate that unprecedented advances in lymphedema treatment can be anticipated in the upcoming years.
Response to: Blindness Due to Cosmetic Fillers: Critical Points in the External/Internal Carotid Artery Anastomosis System
Background Wearable devices and sensor technology provide objective, unbiased range of motion measurements that help health care professionals overcome the hindrances of protractor-based goniometry. This review aims to analyze the accuracy of existing wearable sensor technologies for hand range of motion measurement and identify the most accurate one. Methods We performed a systematic review by searching PubMed, CINAHL, and Embase for studies evaluating wearable sensor technology in hand range of motion assessment. Keywords used for the inquiry were related to wearable devices and hand goniometry. Results Of the 71 studies, 11 met the inclusion criteria. Ten studies evaluated gloves and 1 evaluated a wristband. The most common types of sensors used were bend sensors, followed by inertial sensors, Hall effect sensors, and magnetometers. Most studies compared wearable devices with manual goniometry, achieving optimal accuracy. Although most of the devices reached adequate levels of measurement error, accuracy evaluation in the reviewed studies might be subject to bias owing to the use of poorly reliable measurement techniques for comparison of the devices. Conclusion Gloves using inertial sensors were the most accurate. Future studies should use different comparison techniques, such as infrared camera–based goniometry or virtual motion tracking, to evaluate the performance of wearable devices.