Back to Authors

Hu, Tiffany

https://orcid.org/0000-0002-7285-5070

Mayo Clinic

Mayo Clinic

Citations 7

Catheter Ablation of Atrial Fibrillation in Adult Congenital Heart Disease: Procedural Characteristics and Outcomes
Hu, Tiffany , Janga, Chaitra , Amin, Mustapha, Tan, Nicholas Y. , Hodge, David O. , Mehta, Ramila A. , McLeod, Christopher J. , Chiriac, Anca , Miranda, William R. , Connolly, Heidi M. , Asirvatham, Samuel J. , Deshmukh, Abhishek , Egbe, Alexander C. , Madhavan, Malini , Hu, Tiffany Y , Deshmukh, Abhishek J , Asirvatham, Samuel J , McLeod, Christopher J

Circulation: Arrhythmia and Electrophysiology | July 24, 2023 | Volume: 16 | Issue: 8 | Pages: 437-446

10.1161/circep.122.011392 Get It

BACKGROUND: The outcomes of catheter ablation for atrial fibrillation in adults with congenital heart disease are not well described. METHODS: In a retrospective study of adult patients with congenital heart disease who underwent catheter ablation for atrial fibrillation between 2000 and 2020 at Mayo Clinic, procedural characteristics and outcomes were collected. The primary outcomes were atrial arrhythmia (AA) recurrence following a 3-month blanking period and repeat ablation. An arrhythmia clinical severity score was assessed pre- and post-ablation based on the duration of arrhythmia episodes, symptoms, cardioversion frequency, and antiarrhythmic drug use. RESULTS: One hundred forty-five patients (age, 57±12 years; 28% female; 63% paroxysmal atrial fibrillation) underwent 198 ablations with a median follow-up of 26 months (interquartile range, 14–69). One hundred ten, 26, and 9 patients had simple, moderate, and complex congenital heart disease, respectively. All patients underwent pulmonary vein isolation, and non–pulmonary vein targets were ablated in 79 (54%). AA recurrence at 12 months was 37% (95% CI, 29%–45%). On univariate analysis, increasing left atrial volume index was associated with higher odds of AA recurrence (odds ratio, 1.03 [1.00–1.06] per 1 mL/m 2 increment; P =0.05). Noninducibility of atrial flutter was predictive of decreased odds of AA recurrence (odds ratio, 0.43 [0.21–0.90]; P =0.03). A second ablation was performed in 43 patients after a median of 20 (interquartile range, 8–37) months. Arrhythmia clinical severity scores improved following ablation, reflecting a decrease in symptoms, cardioversions, and antiarrhythmic drugs. CONCLUSIONS: Catheter ablation of atrial fibrillation is feasible and effective in patients with adult congenital heart disease and reduces symptoms. Recurrence of AA frequently requires repeat ablation.
Paroxysmal supine hypoxaemia with hyperthyroidism and atrial fibrillation: a case report of a diagnostic challenge
Liu, Liang Yen , Reddy, Yogesh N.V. , Niven, Alexander S. , Hu, Tiffany , Mulpuru, Siva K. , Cullen, Michael W. , Hu, Tiffany Y, Larson, Kathryn F. , Nishimura, Rick , Niven, Alexander S

European Heart Journal - Case Reports | May 24, 2022 | Volume: 6 | Issue: 6 | Pages: No page available

10.1093/ehjcr/ytac214 Get It

Abstract Background A patent foramen ovale (PFO) is a persistent embryonic defect in the interatrial septum. Platypnoea-orthodeoxia syndrome is characterized by positional hypoxaemia that is most commonly due to right-to-left shunting through a PFO. Dynamic right-to-left shunting through a PFO can also exacerbate positional hypoxaemia without platypnea-orthodeoxia syndrome. Case summary A 78-year-old woman with hyperthyroidism and paroxysmal atrial fibrillation (AF) presented with positional hypoxaemia exacerbated by supine positioning. Diagnostic testing revealed intermittent right-to-left shunting through a PFO triggered by worsening atrial functional tricuspid regurgitation and elevated right atrial pressures. Diuresis, rate control, and thyroidectomy initially led to resolution of positional hypoxaemia, but recurrent AF episodes triggered right-to-left shunting with recurrent desaturation. Left atrial and cavo-tricuspid isthmus ablation led to restoration of normal sinus rhythm and resolution of positional hypoxaemia without PFO closure. Discussion The clinical presentation of intermittent intracardiac right-to-left shunting can mimic decompensated heart failure with pulmonary oedema. Persistent hypoxaemia out of proportion to the degree of pulmonary oedema and minimally responsive to supplemental O2 should raise suspicion for right-to-left shunt aetiology. Positional arterial blood gases can facilitate the diagnostic evaluation of refractory hypoxaemia in cases of suspected shunting. Diagnostic imaging for PFO detection includes both transthoracic and transesophageal echocardiography with Valsalva manoeuver and agitated saline injection. Closure of a PFO for management of arterial deoxygenation syndromes should not be performed before treating other causes of arterial deoxygenation and optimizing factors that may exacerbate shunting across the PFO.
Abstract 344: Optimal Serum Potassium, Calcium and Magnesium in the Coronary Care Unit
Krittanawong, Chayakrit , Park, Jae Y, Sharma, Sunita , Gaba, Prakriti , Rosenbaum, Andrew , Hu, Tiffany , Bell, Malcolm R. , Brady, Peter A. , Naksuk, Niyada , Krittanawong, Chayakrit , Thongprayoon, Charat , Herasevich, Vitaly , Kapa, Suraj , Asirvatham, Samuel J.

Circulation: Cardiovascular Quality and Outcomes | March 20, 2022 | Volume: 8 | Issue: suppl_2 | Pages: No page available

10.1161/circoutcomes.8.suppl_2.344 Get It

Background: It is known that hypokalemia, hypocalcemia and hypomagnesemia cause a prolonged QTc interval and are associated with an increased risk of ventricular arrhythmias. However, there are limited data on optimal serum electrolytes for patients admitted to the coronary care unit (CCU). Objective: Here, we aimed to evaluate the relationship between serum potassium, ionized calcium and magnesium levels and in-hospital mortality in the CCU setting. Methods: This retrospective cohort study included 8,498 consecutive patients admitted to the CCU at an academic tertiary medical center from 2004 through 2013. The mean of serum electrolytes was categorized as <3.5, 3.5-<4.0, 4.0-<4.5 (reference), 4.5-<5.0, and ≥5.0 mEq/L for potassium; <4.4, 4.4-<4.6, 4.6-<4.8, 4.8-<5.0 (reference), and ≥5.0 mg/dL for ionized calcium; and <1.8, 1.8-<2.0, 2.0-<2.2 (reference), 2.2-<2.4, and ≥2.4 mg/dL for magnesium. Multivariate logistic regression analysis was used to determine the association between the mean of serum electrolytes and in-hospital mortality. Results: Of the 8,498 patients, 599 (7%) died during hospitalization. Relationship between mean serum potassium (U-shaped), ionized calcium (inverted J-shape) and magnesium (J-shaped) and in-hospital mortality was present in Figure. Serum potassium levels <3.5, 4.5-<5.0 and ≥5.0 mEq/L were independently associated with an increased risk of in-hospital mortality (adjusted OR 1.7 95% CI 1.1-2.5, OR 1.7 95% CI 1.3-2.2, and OR 3.4 95% CI 2.4-4.8, respectively), compared to the reference group. As for serum ionized calcium, the levels of <4.4, 4.4-<4.6, and 4.6-<4.8 mg/dL independently increased risk of mortality (adjusted OR 3.0 95% CI 2.3-4.0, OR 2.0 95% CI 1.5-2.6, and OR 1.4 95% CI, 1.1-1.8, respectively). As for serum magnesium, an only level above 2.4 mg/dL was associated with an increased mortality risk (OR 1.6 95% CI, 1.1-2.2). Conclusions: In the CCU setting, serum potassium 3.5-<4.5 mEq/L, ionized calcium ≥5.0 mg/dL and magnesium <2.4 mg/dL are associated with the lowest in-hospital mortality. These findings do not support supratherapeutic repletion of potassium and magnesium.
Heart Watch Study: protocol for a pragmatic randomised controlled trial
Dhruva, Sanket S. , Shah, Nilay D. , Vemulapalli, Sreekanth , Deshmukh, Abhishek , Gamble, Ginger , Hummel, James P. , Piccini, Jonathan P. , Akar, Joseph G. , Ervin, Keondae, Arges, Kristine, Emanuel, Lindsay, Hu, Tiffany , Bartlett, Victoria , Gamble, Ginger M , Piccini, Jonathan P , Beatty, Alexis L. , Freeman, James V. , Noseworthy, Peter A. , Hu, Tiffany, Ross, Joseph S.

BMJ Open | December 30, 2021 | Volume: 11 | Issue: 12 | Pages: e054550

10.1136/bmjopen-2021-054550 Get It

Introduction Personal digital devices that provide health information, such as the Apple Watch, have developed an increasing array of cardiopulmonary tracking features which have received regulatory clearance and are directly marketed to consumers. Despite their widespread and increasing use, data about the impact of personal digital device use on patient-reported outcomes and healthcare utilisation are sparse. Among a population of patients with atrial fibrillation and/or atrial flutter undergoing cardioversion, our primary aim is to determine the impact of the heart rate measurement, irregular rhythm notification, and ECG features of the Apple Watch on quality of life and healthcare utilisation. Methods and analysis We are conducting a prospective, open-label multicentre pragmatic randomised clinical trial, leveraging a unique patient-centred health data sharing platform for enrolment and follow-up. A total of 150 patients undergoing cardioversion for atrial fibrillation or atrial flutter will be randomised 1:1 to receive the Apple Watch Series 6 or Withings Move at the time of cardioversion. The primary outcome is the difference in the Atrial Fibrillation Effect on QualiTy-of-life global score at 6 months postcardioversion. Secondary outcomes include inpatient and outpatient healthcare utilisation. Additional secondary outcomes include a comparison of the Apple Watch ECG and pulse oximeter features with gold-standard data obtained in routine clinical care settings. Ethics and dissemination The Institutional Review Boards at Yale University, Mayo Clinic, and Duke University Health System have approved the trial protocol. This trial will provide important data to policymakers, clinicians and patients about the impact of the heart rate, irregular rhythm notification, and ECG features of widely used personal digital devices on patient quality of life and healthcare utilisation. Findings will be disseminated to study participants, at professional society meetings and in peer-reviewed journals. Trial registration number NCT04468321
Trends in reported industry payments to physicians practicing cardiac electrophysiology from 2013 to 2018 in the United States
Tseng, Andrew S. , Hu, Tiffany , Lee, Justin Z. , Amin, Mustapha, Vaidya, Vaibhav R. , Deshmukh, Abhishek , Madhavan, Malini , Cha, Yong‐Mei , Asirvatham, Samuel J. , Mulpuru, Siva K. , Hu, Tiffany Y, Vaidya, Vaibhav , Tseng, A S , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | September 21, 2020 | Volume: 31 | Issue: 12 | Pages: 3106-3114

10.1111/jce.14754 Get It

AbstractIntroductionThe need for transparency in financial relationships in the healthcare system, has culminated in Open Payments database, managed by the Center for Medicare and Medicaid Services (CMS). Since its inception in 2013, the trend in such payments to physicians practicing cardiac electrophysiology was not examined.Methods and ResultsPayment information reported to CMS from January 2013 to December 2018 was obtained from the publicly available Open Payments data set using the online query tool. The data were analyzed by an individual provider and by state. An in‐depth analysis of payments in the year 2018 payments was performed. From 2014 to 2018, there was an 18% increase in the total number of payments reported from 88 877 payments in 2014 to 105 000 in 2018. Despite the increase in the total number of payments reported, the average payment steadily decreased over time, resulting in an overall reduction in the total amount of payments from 2014 to 2018 ($34.9 million to $28.2 million). Payments to the top 5% of individual recipients have also decreased over this time. In 2018, 2888 unique providers received reportable payments, a total of 105 000 payments, with a median payment amount of $1378 (interquartile range: $165–$5781). The majority of these payments were for food and beverage (82%) and travel/lodging (10%). The top five payers include Boston Scientific, Medtronic Vascular, Abbott Laboratories, Janssen Pharmaceuticals, and Biotronik.ConclusionAmong cardiac electrophysiologists, there is increased reporting of payments in the Open Payments program over time, with a notable decrease in the payment amount.
Editor’s Choice-Clinical impact of delirium and antipsychotic therapy: 10-Year experience from a referral coronary care unit
Naksuk, Niyada , Park, Jae Y, Sharma, Sunita, Gaba, Prakriti , Rosenbaum, Andrew , Peeraphatdit, Thoetchai , Hu, Tiffany , Bell, Malcolm R. , Herasevich, Vitaly , Brady, Peter A. , Asirvatham, Samuel J. , Rosenbaum, Andrew N , Hu, Tiffany Y, Kapa, Suraj , Thongprayoon, Charat , Asirvatham, Samuel J , Herasevich, Vitaly

European Heart Journal: Acute Cardiovascular Care | June 30, 2015 | Volume: 6 | Issue: 6 | Pages: 560-568

10.1177/2048872615592232 Get It

Catheter Ablation Related Mitral Valve Injury: The Importance of Early Recognition and Rescue Mitral Valve Repair
Hu, Tiffany , Ebrille, Elisa , Syed, Faisal F. , Vaidya, Vaibhav R. , Cha, Yong‐Mei , Valverde, Arturo M. , Friedman, Paul A. , Suri, Rakesh M. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 9 | Pages: 971-975

10.1111/jce.12439 Get It

Mitral Valve Injury with Catheter AblationIntroductionAn increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation‐related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.MethodsWe searched the Mayo Clinic MV surgical database over a 19‐year period (1993–2012) and the electrophysiologic procedures database over a 23‐year period (1990–2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.ResultsIndications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left‐sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure.ConclusionCircular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.