Ex vivo coronary calcium volume quantification using a high-spatial-resolution clinical photon-counting-detector computed tomography
Marsh, Jeffrey F., VanMeter, Patrick D., Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | July 4, 2023 | Volume: 10 | Issue: 04 | Pages: No page available

10.1117/1.jmi.10.4.043501 | PMID 37408984 Get It

Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Ahmed, Zaki , Ferrero, Andrea , Ren, Liqiang , Vrieze, Thomas J., Favazza, Christopher , Yu, Lifeng , Bruesewitz, Michael R. , Favazza, Christopher P, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Journal of Applied Clinical Medical Physics | June 19, 2023 | Volume: 24 | Issue: 7 | Pages: No page available

10.1002/acm2.14074 | PMID 37335819 Get It

AbstractPurposeTo determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.MethodsA daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.ResultsThe daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.ConclusionProtocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.
Quantifying lumen diameter in coronary artery stents with high‐resolution photon counting detector CT and convolutional neural network denoising
Koons, Emily K. , Thorne, Jamison E. , Huber, Nathan R. , Chang, Shaojie , Rajendran, Kishore , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | April 18, 2023 | Volume: 50 | Issue: 7 | Pages: 4173-4181

10.1002/mp.16415 | PMID 37069830 Get It

AbstractBackgroundSmall coronary arteries containing stents pose a challenge in CT imaging due to metal‐induced blooming artifact. High spatial resolution imaging capability is as the presence of highly attenuating materials limits noninvasive assessment of luminal patency.PurposeThe purpose of this study was to quantify the effective lumen diameter within coronary stents using a clinical photon‐counting‐detector (PCD) CT in concert with a convolutional neural network (CNN) denoising algorithm, compared to an energy‐integrating‐detector (EID) CT system.MethodsSeven coronary stents of different materials and inner diameters between 3.43 and 4.72 mm were placed in plastic tubes of diameters 3.96–4.87 mm containing 20 mg/mL of iodine solution, mimicking stented contrast‐enhanced coronary arteries. Tubes were placed parallel with or perpendicular to the scanner's z‐axis in an anthropomorphic phantom emulating an average‐sized patient and scanned with a clinical EID‐CT and PCD‐CT. EID scans were performed using our standard coronary computed tomography angiography (cCTA) protocol (120 kV, 180 quality reference mAs). PCD scans were performed using the ultra‐high‐resolution (UHR) mode (120 × 0.2 mm collimation) at 120 kV with tube current adjusted so that CTDIvol was matched to that of EID scans. EID images were reconstructed per our routine clinical protocol (Br40, 0.6 mm thickness), and with the sharpest available kernel (Br69). PCD images were reconstructed at a thickness of 0.6 mm and a dedicated sharp kernel (Br89) which is only possible with the PCD UHR mode. To address increased image noise introduced by the Br89 kernel, an image‐based CNN denoising algorithm was applied to the PCD images of stents scanned parallel to the scanner's z‐axis. Stents were segmented based on full‐width half maximum thresholding and morphological operations, from which effective lumen diameter was calculated and compared to reference sizes measured with a caliper.ResultsSubstantial blooming artifacts were observed on EID Br40 images, resulting in larger stent struts and reduced lumen diameter (effective diameter underestimated by 41% and 47% for parallel and perpendicular orientations, respectively). Blooming artifacts were observed on EID Br69 images with 19% and 31% underestimation of lumen diameter compared to the caliper for parallel and perpendicular scans, respectively. Overall image quality was substantially improved on PCD, with higher spatial resolution and reduced blooming artifacts, resulting in the clearer delineation of stent struts. Effective lumen diameters were underestimated by 9% and 19% relative to the reference for parallel and perpendicular scans, respectively. CNN reduced image noise by about 50% on PCD images without impacting lumen quantification (<0.3% difference).ConclusionThe PCD UHR mode improved in‐stent lumen quantification for all seven stents as compared to EID images due to decreased blooming artifacts. Implementation of CNN denoising algorithms to PCD data substantially improved image quality.
High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose
Dunning, Chelsea A. S. , Tandon, Yasmeen K. , Ahmed, Zaki, Larson, Nicholas B. , Thorne, Jamison E. , Williamson, Eric E. , Larson, Nicholas B , Rajiah, Prabhakar , Rajendran, Kishore , Collins, Jeremy D. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Investigative Radiology | February 23, 2023 | Volume: 58 | Issue: 9 | Pages: 681-690

10.1097/rli.0000000000000961 | PMID 36822655 Get It

Objectives The aim of this study was to evaluate the high-helical pitch, multienergy (ME) scanning mode of a clinical dual-source photon-counting detector (PCD) computed tomography (CT) and the benefit of virtual monoenergetic images (VMIs) for low-contrast-dose coronary CT angiography (CTA). Materials and Methods High-pitch (3.2) ME coronary CTA was performed in PCD-CT in 27 patients using low contrast dose (30 mL of iohexol 350 mg/mL) and in 26 patients at routine contrast dose (60 mL). Low-energy-threshold 120 kV images (also known as T3D images) and 50 kiloelectron volts (50 keV) and 100 kiloelectron volts (100 keV) VMIs were reconstructed using a 1024 × 1024 matrix and 0.6-mm slices. The CT numbers, noise, and contrast-to-noise ratio (CNR) were measured in the ascending aorta (AA), left main coronary artery (LMCA), and distal left anterior descending (LAD) artery. Confidence in grading luminal stenosis with calcific plaque, noncalcific plaque, and stent was evaluated by 2 independent readers on a 0–100 scale (0 the lowest), and a CAD-RADS score was assigned. Image contrast enhancement, sharpness, noise, artifacts, and overall image quality were rated using a 5-point ordinal scale (1 the lowest). Results The radiation doses (CTDI) in low- and routine-contrast cohorts were 2.5 ± 0.6 mGy and 3.1 ± 1.7 mGy, respectively ( P = 0.12). At all measured locations, the mean CT number was >300 HU in 120 kV (LMCA 382.9 ± 76.2, distal LAD 341.0 ± 53.9, AA 399.5 ± 76.1) and 50 keV images (LMCA 667.5 ± 139.9, distal LAD 578.1 ± 121.5, AA 700.8 ± 142.5) in the low-contrast cohort, with a 96% increase in CT numbers for 50 keV over 120 kV. The CT numbers were significantly higher ( P < 0.0001) in 50 keV than 120 kV and 100 keV VMI. The CNR was also significantly ( P < 0.0001) higher in 50 keV than 120 kV and 100 keV images in all vessels. Confidence in the assessment of luminal stenosis in the presence of calcific plaque was significantly higher ( P = 0.001) with the addition of 100 keV VMI (median score, 100) than using 50 keV alone (median score, 70) and 120 kV (median score, 70) for reader 1, but no significant differences were seen for reader 2 who had same median scores of 100 for all image types. The confidence in the assessment of luminal stenosis within a stent improved with the use of 100 keV images for both readers (reader 1: median scores for 50 + 100 keV = 100, 50 keV = 82.5, 120 kV = 82.5; reader 2: 50 + 100 keV = 100, 50 keV = 90, 120 kV = 90). There were no significant differences in confidence scores for assessment of luminal stenosis from noncalcific plaques for both readers. The reader-averaged qualitative scores for vascular enhancement and overall image quality were significantly higher for 50 keV VMI than for 120 kV images in both low- and routine-contrast dose cohorts. The image sharpness was nonsignificantly higher at 50 keV VMI than 120 kV images, and the artifact score was comparable for 50 keV VMI and 120 kV images. The noise was higher in 50 keV VMI than in 120 kV images. Conclusions High-pitch ME PCD-CT mode produced diagnostic quality coronary CTA images at low radiation and iodinated contrast doses. The availability of ME VMIs significantly improved the CNR, overall image quality, and confidence in assessment of luminal stenosis in the presence of calcific plaques and stents, and resulted in change of CAD-RADS categories in 9 patients.
Measurement of enhanced vasa vasorum density in a porcine carotid model using photon counting detector CT
Marsh, Jeffrey F., Vercnocke, Andrew J. , Tao, Shengzhen , Anderson, Jill , Ritman, Erik L., Rajendran, Kishore , Anderson, Jill L, Leng, Shuai , McCollough, Cynthia H , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | February 6, 2023 | Volume: 10 | Issue: 01 | Pages: No page available

10.1117/1.jmi.10.1.016001 | PMID 36778671 Get It

High‐pitch, high temporal resolution, multi‐energy cardiac imaging on a dual‐source photon‐counting‐detector CT
Ahmed, Zaki, Campeau, David, Gong, Hao , Rajiah, Prabhakar , McCollough, Cynthia, Rajiah, Prabhakar , Rajendran, Kishore , McCollough, Cynthia H. , Leng, Shuai

Medical Physics | November 25, 2022 | Volume: 50 | Issue: 3 | Pages: 1428-1435

10.1002/mp.16124 | PMID 36427356 Get It

AbstractObjectiveTo measure the accuracy of material decomposition using a dual‐source photon‐counting‐detector (DS‐PCD) CT operated in the high‐pitch helical scanning mode and compare the results against dual‐source energy‐integrating‐detector (DS‐EID) CT, which requires use of a low‐pitch value in dual‐energy mode.MethodsA DS‐PCD CT and a DS‐EID CT were used to scan a cardiac motion phantom consisting of a 3‐mm diameter iodine cylinder. Iodine maps were reconstructed using DS‐PCD in high‐pitch mode and DS‐EID in low‐pitch mode. Image‐based circularity, diameter, and iodine concentration of the iodine cylinder were calculated and compared between the two scanners. With institutional review board approval, in vivo exams were performed with the DS‐PCD CT in high‐pitch mode. Images were qualitatively compared against patients with similar heart rates that were scanned with DS‐EID CT in low‐pitch dual‐energy mode.ResultsOn iodine maps, the mean circularity was 0.97 ± 0.02 with DS‐PCD in high‐pitch mode and 0.95 ± 0.06 with DS‐EID in low‐pitch mode. The mean diameter was 2.9 ± 0.2 mm with DS‐PCD and 3.1 ± 0.2 mm with DS‐EID, both of which are close to the 3 mm ground truth. For DS‐PCD, the mean iodine concentration was 9.6 ± 0.8 mg/ml and this was consistent with the 9.4 ± 0.6 mg/ml value obtained with the cardiac motion disabled. For DS‐EID, the concentration was 12.7 ± 1.2 mg/ml with motion enabled and 11.7 ± 0.5 mg/ml disabled. The background noise in the iodine maps was 15.1 HU with DS‐PCD and 14.4 HU with DS‐EID, whereas the volume CT dose index (CTDIvol) was 3 mGy with DS‐PCD and 11 mGy with DS‐EID. On comparison of six patients (three on PCD, three on EID) with similar heart rates, DS‐PCD provided iodine maps with well‐defined coronaries even at a high heart rate of 86 beats per minute. Meanwhile, there were substantial motion artifacts in iodine maps obtained with DS‐EID for patients with similar heart rates.ConclusionIn a cardiac motion phantom, DS‐PCD CT can perform accurate material decomposition in high‐pitch mode, providing iodine maps with excellent geometric accuracy and robustness to motion at approximately 38% of the dose for similar noise as DS‐EID CT.
Photon-Counting Detector CT for Musculoskeletal Imaging: A Clinical Perspective
Glazebrook, Katrina N. , Ferrero, Andrea , Baffour, Francis , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Rajendran, Kishore

American Journal of Roentgenology | October 19, 2022 | Volume: 220 | Issue: 4 | Pages: 551-560

10.2214/ajr.22.28418 | PMID 36259593 Get It

Role of MIF1 / MIF2 / CD74 interactions in bladder cancer
Woolbright, Benjamin L. , Rajendran, Ganeshkumar, Abbott, Erika, Martin, Austin, Amalraj, Sarah, Dennis, Katie , Warrick, Joshua, Li, Xiaogang , Taylor, John Arthur

The Journal of Pathology | October 10, 2022 | Volume: 259 | Issue: 1 | Pages: 46-55

10.1002/path.6018 | PMID 36214539 Get It

Abstract Macrophage migration inhibitory factor (MIF1) is a pleiotropic cytokine involved in inflammation and cancer. Genetic knockout of Mif1 in the validated N ‐butyl‐ N ‐(4‐hydroxybutyl) nitrosamine (BBN) model of bladder cancer (BCa) resulted in stage arrest at non‐muscle‐invasive disease in prior studies. Small‐molecule inhibition of MIF1 reduced cancer‐associated outcomes, but it did not fully recapitulate genetic models. D‐dopachrome tautomerase (gene symbol DDT ), commonly referred to as MIF2, is a functional homolog of MIF1, and both MIF1 and MIF2 can bind the cell surface receptor CD74 on multiple cell types to initiate a signaling cascade. It has been proposed that this interaction mediates part of the protumorigenic effects of MIF1 and MIF2 and may explain the discordance in prior studies. We hypothesized that MIF2 functions redundantly with MIF1 in BCa development and progression. The Cancer Genome Atlas (TCGA) analysis indicated MIF and DDT expression were increased in BCa patients compared to control. 4‐Iodopyridine (4‐IPP), a combined MIF1/MIF2 inhibitor, was more efficacious than ISO‐1, a MIF1‐only inhibitor, in preventing cellular proliferation in BCa cell lines. To evaluate these findings in vivo , wild‐type (WT) and Mif1 −/− animals were exposed to 0.05% BBN in drinking water for 16 weeks to initiate tumorigenesis and then evaluated over the subsequent 4 weeks for tumor formation and progression in the presence or absence of 4‐IPP. 4‐IPP reduced bladder weights in WT animals and bladder weights/tumor stage in Mif1 −/− animals. To determine whether MIF1/MIF2 functioned through CD74 in BCa, WT or Cd74 −/− animals were used in the same BBN model. Although these animals were partially protected against BBN‐induced BCa, 4‐IPP did not enhance this effect. In conclusion, our data suggest that MIF2 mechanistically functions in a similar protumorigenic manner to MIF1, and this is at least partially through CD74. Dual inhibition of MIF homologs is more efficacious at reducing tumor burden in this model of BCa. © 2022 The Pathological Society of Great Britain and Ireland.
Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography
Huber, Nathan R. , Ferrero, Andrea , Rajendran, Kishore , Glazebrook, Katrina N. , Yu, Lifeng , Baffour, Francis , Diehn, Felix E. , Inoue, Akitoshi , Rajendran, Kishore , Huber, Nathan Robert , Fletcher, Joel G. , Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H.

Physics in Medicine & Biology | August 9, 2022 | Volume: 67 | Issue: 17 | Pages: 175014

10.1088/1361-6560/ac8866 | PMID 35944556 Get It

Abstract Objective. To develop a convolutional neural network (CNN) noise reduction technique for ultra-high-resolution photon-counting detector computed tomography (UHR-PCD-CT) that can be efficiently implemented using only clinically available reconstructed images. The developed technique was demonstrated for skeletal survey, lung screening, and head angiography (CTA). Approach . There were 39 participants enrolled in this study, each received a UHR-PCD and an energy integrating detector (EID) CT scan. The developed CNN noise reduction technique uses image-based noise insertion and UHR-PCD-CT images to train a U-Net via supervised learning. For each application, 13 patient scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) and allocated into training, validation, and testing datasets (9:1:3). The subtraction of FBP and IR images resulted in approximately noise-only images. The 5-slice average of IR produced a thick reference image. The CNN training input consisted of thick reference images with reinsertion of spatially decoupled noise-only images. The training target consisted of the corresponding thick reference images without noise insertion. Performance was evaluated based on difference images, line profiles, noise measurements, nonlinear perturbation assessment, and radiologist visual assessment. UHR-PCD-CT images were compared with EID images (clinical standard). Main results. Up to 89% noise reduction was achieved using the proposed CNN. Nonlinear perturbation assessment indicated reasonable retention of 1 mm radius and 1000 HU contrast signals (>80% for skeletal survey and head CTA, >50% for lung screening). A contour plot indicated reduced retention for small-radius and low contrast perturbations. Radiologists preferred CNN over IR for UHR-PCD-CT noise reduction. Additionally, UHR-PCD-CT with CNN was preferred over standard resolution EID-CT images. Significance. CT images reconstructed with very sharp kernels and/or thin sections suffer from increased image noise. Deep learning noise reduction can be used to offset noise level and increase utility of UHR-PCD-CT images.