Citations

Mayo Clinic

Clear

48 citation(s) found for "Zaki, A A".

Performance evaluation of single‐ and dual‐contrast spectral imaging on a photon‐counting‐detector CT
Ren, Liqiang , Zhou, Zhongxing , Ahmed, Zaki , Yu, Lifeng , Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | September 5, 2024 | Volume: 51 | Issue: 11 | Pages: 8034-8046

10.1002/mp.17367 | PMID 39235343 Get It

AbstractBackgroundThe first commercially available photon‐counting‐detector CT (PCD‐CT) has been introduced for clinical use. However, its spectral performance on single‐ and dual‐contrast imaging tasks has not been comprehensively assessed.PurposeTo evaluate the spectral imaging performance of a clinical PCD‐CT system for single‐contrast material [iodine (I) or gadolinium (Gd)] and dual‐contrast materials (I and Gd) in comparison with a dual‐source dual‐energy CT (DS‐DECT).MethodsIodine (5, 10, and 15 mg/mL) and gadolinium (3.3, 6.6, and 9.9 mg/mL) samples, and their mixtures (I/Gd: 5/3.3 and 10/6.6 mg/mL) were prepared and placed in two torso‐shaped water phantoms (lateral dimensions: 30 and 40 cm). These phantoms were scanned on a PCD‐CT (NAEOTOM Alpha, Siemens) at 90, 120, and 140 kV. The same phantoms were scanned on a DS‐DECT (SOMATOM Force, Siemens) with 70/Sn150, 80/Sn150, 90/Sn150, and 100/Sn150 kV. The radiation dose levels were matched [volume CT dose index (CTDIvol): 10 mGy for the 30 cm phantom and 20 mGy for the 40 cm phantom] across all tube voltage settings and between scanners. Two‐material decomposition (I/water or Gd/water) was performed on iodine or gadolinium samples, and three‐material decomposition (I/Gd/water) on both individual samples and mixtures. On each decomposed image, mean mass concentration (± standard deviation) was measured in circular region‐of‐interests placed on the contrast samples. Root‐mean‐square‐error (RMSE) values of iodine and gadolinium concentrations were reported based on the measurements across all contrast samples and repeated on 10 consecutive slices.ResultsFor all material decomposition tasks on the DS‐DECT, the kV pairs with greater spectral separation (70/Sn150 kV and 80/Sn150 kV) yielded lower RMSE values than other DS‐DECT and PCD‐CT alternatives. Specifically, for the optimal 70/Sn150 kV, RMSE values were 1.2 ± 0.1 mg/mL (I) for I/water material decomposition, 1.0 ± 0.1 mg/mL (Gd) for Gd/water material decomposition, and 4.5 ± 0.2 mg/mL (I) and 3.7 ± 0.2 mg/mL (Gd), respectively, for I/Gd/water material decomposition. On the PCD‐CT, the optimal tube voltages were 120 or 140 kV for I/water decomposition with RMSE values of 2.0 ± 0.1 mg/mL (I). For Gd/water decomposition on PCD‐CT, the optimal tube voltage was 140 kV with gadolinium RMSE values of 1.5 ± 0.1 mg/mL (Gd), with the 90 kV setting on PCD‐CT generating higher RMSE values for gadolinium concentration compared to all DS‐DECT and PCD‐CT alternatives. For three material decomposition, both imaging modalities demonstrated substantially higher RMSE values for iodine and gadolinium, with 90 kV being the optimal tube potential for Gd/I quantitation on PCD‐CT [5.4 ± 0.3 mg/mL (I) and 3.9 ± 0.2 mg/mL (Gd)], and DS‐DECT at 100/Sn150 kV having larger RMSE values for both materials compared to the alternatives for either modality.ConclusionOptimal tube voltage for material decomposition on the clinical PCD‐CT is task‐dependent but inferior to DS‐DECT using 70/Sn150 kV or 80/Sn150 kV in two‐material decomposition for single‐contrast imaging (iodine/water or gadolinium/water). Three material decomposition (iodine/gadolinium/water) in dual‐contrast imaging yields substantially higher RMSE for both imaging platforms.
Data driven discovery and quantification of hyperspectral leaf reflectance phenotypes across a maize diversity panel
Tross, Michael C. , Grzybowski, Marcin , Grove, Ryleigh J. , Nishimwe, Aime V. , Ganapathysubramanian, Baskar , Grzybowski, Marcin W , Jubery, Talukder Zaki , Torres‐Rodríguez, J. Vladimir , Sun, Guangchao , Ge, Yufeng , Schnable, James C

The Plant Phenome Journal | June 7, 2024 | Volume: 7 | Issue: 1 | Pages: No page available

10.1002/ppj2.20106 Get It

Abstract Estimates of plant traits derived from hyperspectral reflectance data have the potential to efficiently substitute for traits, which are time or labor intensive to manually score. Typical workflows for estimating plant traits from hyperspectral reflectance data employ supervised classification models that can require substantial ground truth datasets for training. We explore the potential of an unsupervised approach, autoencoders, to extract meaningful traits from plant hyperspectral reflectance data using measurements of the reflectance of 2151 individual wavelengths of light from the leaves of maize ( Zea mays ) plants harvested from 1658 field plots in a replicated field trial. A subset of autoencoder‐derived variables exhibited significant repeatability, indicating that a substantial proportion of the total variance in these variables was explained by difference between maize genotypes, while other autoencoder variables appear to capture variation resulting from changes in leaf reflectance between different batches of data collection. Several of the repeatable latent variables were significantly correlated with other traits scored from the same maize field experiment, including one autoencoder‐derived latent variable (LV8) that predicted plant chlorophyll content modestly better than a supervised model trained on the same data. In at least one case, genome‐wide association study hits for variation in autoencoder‐derived variables were proximal to genes with known or plausible links to leaf phenotypes expected to alter hyperspectral reflectance. In aggregate, these results suggest that an unsupervised, autoencoder‐based approach can identify meaningful and genetically controlled variation in high‐dimensional, high‐throughput phenotyping data and link identified variables back to known plant traits of interest.
An Analysis of the Use of Gender-Inclusive Terminology Amongst Radiology Vendors: Moving Forward From “Women’s Imaging”
Zaki-Metias, Kaitlin M. , Sharma, Sonali , Kolof, Hanna, Yan, Tyler D. , Laule, Cornelia , Carroll, Evelyn F. , Yong‐Hing, Charlotte J. , Yong-Hing, Charlotte J , Narayan, Anand K. , Spalluto, Lucy B.

Canadian Association of Radiologists Journal | January 12, 2024 | Volume: 75 | Issue: 3 | Pages: 671-672

10.1177/08465371231226164 | PMID 38216858 Get It

Motion artifact correction in cardiac CT using cross-phase temporospatial information and synergistic attention gate and spatial transformer sub-networks
Gong, Hao , Ahmed, Zaki, Chang, Shaojie , Koons, Emily K. , Thorne, Jamison E. , Foley, Thomas A. , Gong, Hao , Rajiah, Prabhakar , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Physics in Medicine & Biology | January 5, 2024 | Volume: 69 | Issue: 3 | Pages: 035023

10.1088/1361-6560/ad1b6a | PMID 38181426 Get It

Abstract Objectives. To improve quality of coronary CT angiography (CCTA) images using a generalizable motion-correction algorithm. Approach . A neural network with attention gate and spatial transformer (ATOM) was developed to correct coronary motion. Phantom and patient CCTA images (39 males, 32 females, age range 19–92, scan date 02/2020 to 10/2021) retrospectively collected from dual-source CT were used to create training, development, and testing sets corresponding to 140- and 75 ms temporal resolution, with 75 ms images as labels. To test generalizability, ATOM was deployed for locally adaptive motion-correction in both 140- and 75 ms patient images. Objective metrics were used to assess motion-corrupted and corrected phantom and patient images, including structural-similarity-index (SSIM), dice-similarity-coefficient (DSC), peak-signal-noise-ratio (PSNR), and normalized root-mean-square-error (NRMSE). In objective quality assessment, ATOM was compared with several baseline networks, including U-net, U-net plus attention gate, U-net plus spatial transformer, VDSR, and ResNet. Two cardiac radiologists independently interpreted motion-corrupted and -corrected images at 75 and 140 ms in a blinded fashion and ranked diagnostic image quality (worst to best: 1–4, no ties). Main results . ATOM improved quality metrics ( p < 0.05) before/after correction: in phantom, SSIM 0.87/0.95, DSC 0.85/0.93, PSNR 19.4/22.5, NRMSE 0.38/0.27; in patient images, SSIM 0.82/0.88, DSC 0.88/0.90, PSNR 30.0/32.0, NRMSE 0.16/0.12. ATOM provided more consistent improvement of objective image quality, compared to the presented baseline networks. The motion-corrected images received better ranks than un-corrected at the same temporal resolution ( p < 0.05): 140 ms images 1.65/2.25, and 75 ms images 3.1/3.2. The motion-corrected 75 ms images received the best rank in 65% of testing cases. A fair-to-good inter-reader agreement was observed (Kappa score 0.58). Significance . ATOM reduces motion artifacts, improving visualization of coronary arteries. This algorithm can be used to virtually improve temporal resolution in both single- and dual-source CT.
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Shalom, Eve , Kim, Harrison , Heijden, Rianne A. van der , Ahmed, Zaki , Patel, Reyna, DiCarlo, Julie C. , Yankeelov, Thomas E. , Stokes, Ashley M. , Grech‐Sollars, Matthew , Sahoo, Prativa , Verma, Sanjay Kumar , Rathore, Divya, Kazerouni, Anum S. , LoCastro, Eve , Paudyal, Ramesh , Wolansky, Ivan A. , Shukla‐Dave, Amita , Schouten, Pepijn, Gurney‐Champion, Oliver J. , Macíček, Ondřej , Vitouš, Jiří , Das, Ayesha , Mikheev, Artem , Rusinek, Henry , Cristinacce, Penny L. Hubbard , Little, Ross A. , Cheung, Susan , O’Connor, James P.B. , Moloney, Brendan, Bobholz, Samuel , Duenweg, Savannah , Laue, Hendrik , Sung, Kyunghyun , Nabavizadeh, Ali , Rad, Hamidreza Saligheh , Hu, Leland , Kazerooni, Anahita Fathi , Shalom, Eve S , van der Heijden, Rianne A , Hormuth, David A , DiCarlo, Julie C , Yankeelov, Thomas E , Dortch, Richard D , Grech-Sollars, Matthew , Kazerouni, Anum S , Partridge, Savannah C , LoCastro, Eve , Wolansky, Ivan A , Jiřík, Radovan , Macíček, Ondřej , Bartoš, Michal , Vitouš, Jiří , Das, Ayesha Bharadwaj , Kim, S Gene , Rusinek, Henry , Berks, Michael , Hubbard Cristinacce, Penny L , O'Connor, James P B , Parker, Geoff J M , LaViolette, Peter S , Bobholz, Samuel , Duenweg, Savannah , Virostko, John , Sung, Kyunghyun , Saligheh Rad, Hamidreza , Sourbron, Steven , Bell, Laura C , Fathi Kazerooni, Anahita , Paudyal, Ramesh , Shukla-Dave, Amita , Sisco, Nicholas J. , Inglese, Marianna , Toschi, Nicola , Singh, Anup K. , Schouten, Pepijn, Bokacheva, Louisa , Bell, Laura C.

Magnetic Resonance in Medicine | December 20, 2023 | Volume: 91 | Issue: 5 | Pages: 1803-1821

10.1002/mrm.29909 | PMID 38115695 Get It

AbstractPurpose has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.MethodsA framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.ResultsAcross the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.ConclusionsThis study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
Locally Low-Rank Denoising of Multi-Echo Functional MRI Data With Application in Resting-State Analysis
Meyer, Nolan , Ahmed, Zaki , In, Myung‐Ho , Shu, Yunhong , Trzasko, Joshua D. , Meyer, Nolan K , In, Myung-Ho , Kang, Daehun , Huston, John , Bernstein, Matt A.

Topics in Magnetic Resonance Imaging | October 5, 2023 | Volume: 32 | Issue: 5 | Pages: 37-49

10.1097/rmr.0000000000000307 | PMID 37796647 Get It

Abstract: Objectives: Locally low-rank (LLR) denoising of functional magnetic resonance imaging (fMRI) time series image data is extended to multi-echo (ME) data. The proposed method extends the capabilities of non-physiologic noise suppression beyond single-echo applications with a dedicated ME algorithm. Materials and Methods: Following an institutional review board (IRB) approved protocol, resting-state fMRI data were acquired in 7 healthy subjects. A compact 3T scanner enabled whole-brain acquisition of multiband ME fMRI data at high spatial resolution (1.4 × 1.4 × 2.8 mm3) with a 1810 ms repetition time (TR). Image data were denoised with ME-LLR preceding functional processing. The results of connectivity maps generated from denoised data were compared with maps generated with equivalent processing of non-denoised images. To assess ME-LLR as a method to reduce scan time, comparisons were made between maps computed from image data with full and retrospectively truncated durations. Assessments were completed with seed-based connectivity analyses using echo-combined image data. In a feasibility assessment, nondenoised and denoised full-duration echo-combined data were equivalently processed with independent component analysis (ICA) and compared. Results: ME-LLR denoising yielded strengthened resting-state network connectivity maps after nuisance regression and seed-based connectivity analysis. In assessing ME-LLR as a scan reduction mechanism, maps generated from denoised data at half scan time showed comparable quality with maps generated from full-duration, non-denoised data, at both single subject and group levels. ME-LLR substantially increased temporal signal-to-noise ratio (tSNR) for image data respective to each individual echo and for image data after nuisance regression. Among echo-specific image volumes, increases in tSNR yielded by ME-LLR were most pronounced for image data with the longest echo time and thereby lowest SNR. ICA showed resting-state networks consistently identified between non-denoised and denoised data, with clearer demarcation of networks for ME-LLR. Conclusions: ME-LLR is demonstrated to suppress non-physiologic noise, enhance functional connectivity map quality, and could potentially facilitate scan time reduction in ME-fMRI.
TRAPPC6B biallelic variants cause a neurodevelopmental disorder with TRAPP II and trafficking disruptions
Almousa, Hashem , Lewis, Sara A. , Bakhtiari, Somayeh , Nordlie, Sandra H., Pagnozzi, Alex M. , Magee, Helen, Efthymiou, Stéphanie , Heim, Jennifer, Anwar, Najwa, Maqbool, Shazia , Rahman, Fatima , Neilson, Derek , Vemuri, Anusha, Jin, Sheng Chih , Yang, Xiao‐Ru, Heidari, Abolfazl, Trimouille, Aurélien , Thauvin‐Robinet, Christel , Liu, James, Bruel, Ange‐Line , Tomoum, Hoda , Shata, Mennatallah Osama , Hashem, Mais O, Karimiani, Ehsan Ghayoor , Lingappa, Lokesh , Baruah, Debangana, Ebrahimzadeh, Farnoosh , Van‐Gils, Julien , Faivre, Laurence , Galehdari, Hamid, Sadeghian, Saeid , Mohammad, Rahema, Smagt, Jasper J. van der , Qari, Alya , Akar, Halil Tuna , Bilgüvar, Kaya , Mignot, Cyril , Keren, Boris , Raveli, Claudia, Afenjar, Alexandra , Kaat, Laura Donker , Slegtenhorst, Marjon van, Alkuraya, Fowzan S. , Houlden, Henry , Padilla‐Lopez, Sergio , Maroofian, Reza , Sacher, Michael , Kruer, Michael C. , Cornejo, Patricia , Jin, Sheng Chih , Zamani, Mina , Sadeghian, Saeid , Alkuraya, Fowzan S , Houlden, Henry , Maroofian, Reza , Sacher, Michael , Faivre, Laurence , Donker Kaat, Laura , Zaki, Maha S. , Gassen, Koen L.I. van , Hashem, Mais O, Toosi, Mehran Beiraghi , Yeşil, Gözde , Galehdari, Hamid , Shariati, Gholamreza , Vincent, John B. , Innes, A. Micheil , Dursun, Ali , Özgül, Rıza Köksal , Bürglen, Lydie

Brain | September 15, 2023 | Volume: 147 | Issue: 1 | Pages: 311-324

10.1093/brain/awad301 | PMID 37713627 Get It

Abstract Highly conserved transport protein particle (TRAPP) complexes regulate subcellular trafficking pathways. Accurate protein trafficking has been increasingly recognized to be critically important for normal development, particularly in the nervous system. Variants in most TRAPP complex subunits have been found to lead to neurodevelopmental disorders with diverse but overlapping phenotypes. We expand on limited prior reports on TRAPPC6B with detailed clinical and neuroradiologic assessments, and studies on mechanisms of disease, and new types of variants. We describe 29 additional patients from 18 independent families with biallelic variants in TRAPPC6B. We identified seven homozygous nonsense (n = 12 patients) and eight canonical splice-site variants (n = 17 patients). In addition, we identified one patient with compound heterozygous splice-site/missense variants with a milder phenotype and one patient with homozygous missense variants. Patients displayed non-progressive microcephaly, global developmental delay/intellectual disability, epilepsy and absent expressive language. Movement disorders including stereotypies, spasticity and dystonia were also observed. Brain imaging revealed reductions in cortex, cerebellum and corpus callosum size with frequent white matter hyperintensity. Volumetric measurements indicated globally diminished volume rather than specific regional losses. We identified a reduced rate of trafficking into the Golgi apparatus and Golgi fragmentation in patient-derived fibroblasts that was rescued by wild-type TRAPPC6B. Molecular studies revealed a weakened interaction between mutant TRAPPC6B (c.454C&gt;T, p.Q152*) and its TRAPP binding partner TRAPPC3. Patient-derived fibroblasts from the TRAPPC6B (c.454C&gt;T, p.Q152*) variant displayed reduced levels of TRAPPC6B as well as other TRAPP II complex-specific members (TRAPPC9 and TRAPPC10). Interestingly, the levels of the TRAPPC6B homologue TRAPPC6A were found to be elevated. Moreover, co-immunoprecipitation experiments showed that TRAPPC6A co-precipitates equally with TRAPP II and TRAPP III, while TRAPPC6B co-precipitates significantly more with TRAPP II, suggesting enrichment of the protein in the TRAPP II complex. This implies that variants in TRAPPC6B may preferentially affect TRAPP II functions compared to TRAPP III functions. Finally, we assessed phenotypes in a Drosophila TRAPPC6B-deficiency model. Neuronal TRAPPC6B knockdown impaired locomotion and led to wing posture defects, supporting a role for TRAPPC6B in neuromotor function. Our findings confirm the association of damaging biallelic TRAPPC6B variants with microcephaly, intellectual disability, language impairments, and epilepsy. A subset of patients also exhibited dystonia and/or spasticity with impaired ambulation. These features overlap with disorders arising from pathogenic variants in other TRAPP subunits, particularly components of the TRAPP II complex. These findings suggest that TRAPPC6B is essential for brain development and function, and TRAPP II complex activity may be particularly relevant for mediating this function.
Establishing a quality assurance program for photon counting detector (PCD) CT: Tips and caveats
Ahmed, Zaki , Ferrero, Andrea , Ren, Liqiang , Vrieze, Thomas J., Favazza, Christopher , Yu, Lifeng , Bruesewitz, Michael R. , Favazza, Christopher P, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Journal of Applied Clinical Medical Physics | June 19, 2023 | Volume: 24 | Issue: 7 | Pages: No page available

10.1002/acm2.14074 | PMID 37335819 Get It

AbstractPurposeTo determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon‐counting‐detector (PCD) CT system.MethodsA daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra‐high‐resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low‐energy‐threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi‐energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc.ResultsThe daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc.ConclusionProtocols and parameters must be properly selected on PCD‐CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi‐energy phantom scans are also recommended to comprehensively evaluate PCD‐CT scanner performance.
Recurrent/Subsequent Stroke and Associated Outcomes in Geriatric Patients with OSA and Prior Stroke Events: A Retrospective Study Using the 2019 National Inpatient Sample
Desai, Rupak , Mellacheruvu, Sai Priyanka , Mohammed, Adil Sarvar , Soni, Roshni, Perera, Ayodya , Makarla, Venkata Akhil, Santhosh, Sarayu, Siddiqui, Muneeb, Mohammed, Bilal Khan , Mohammed, Zaki Ur Rahman, Gandhi, Zainab , Vyas, Ankit , Jain, Akhil , Sachdeva, Rajesh , Kumar, Gautam , Mellacheruvu, Sai Priyanka , Mohammed, Adil Sarvar , Vyas, Ankit , Jain, Akhil , Sachdeva, Rajesh , Singh, Sandeep , Kumar, Gautam, Desai, Rupak

Journal of Personalized Medicine | May 1, 2023 | Volume: 13 | Issue: 5 | Pages: 782

10.3390/jpm13050782 | PMID 37240952 Get It

Background: Obstructive sleep apnea (OSA) increases the risk of stroke and cardiovascular diseases. However, its impact on geriatric patients with a prior history of stroke/transient ischemic attack (TIA) has not been adequately studied. Methods: We utilized the 2019 National Inpatient Sample in the US to identify geriatric patients with OSA (G-OSA) who had a prior history of stroke/TIA. We then compared subsequent stroke (SS) rates among sex and race subgroups. We also compared the demographics and comorbidities of SS+ and SS− groups and utilized logistic regression models to assess outcomes. Results: Out of 133,545 G-OSA patients admitted with a prior history of stroke/TIA, 4.9% (6520) had SS. Males had a higher prevalence of SS, while Asian-Pacific Islanders and Native Americans had the highest prevalence of SS, followed by Whites, Blacks, and Hispanics. The SS+ group had higher all-cause in-hospital mortality rates, with Hispanics showing the highest rate compared to Whites and Blacks (10.6% vs. 4.9% vs. 4.4%, p < 0.001), respectively. Adjusted analysis for covariates showed that complicated and uncomplicated hypertension (aOR 2.17 [95% CI 1.78–2.64]; 3.18 [95% CI 2.58–3.92]), diabetes with chronic complications (aOR 1.28 [95% CI 1.08–1.51]), hyperlipidemia (aOR 1.24 [95% CI 1.08–1.43]), and thyroid disorders (aOR 1.69 [95% CI 1.14–2.49]) were independent predictors of SS. The SS+ group had fewer routine discharges and higher healthcare costs. Conclusions: Our study shows that about 5% of G-OSA patients with a prior history of stroke/TIA are at risk of hospitalization due to SS, which is associated with higher mortality and healthcare utilization. Complicated and uncomplicated hypertension, diabetes with chronic complications, hyperlipidemia, thyroid disorders, and admission to rural hospitals predict subsequent stroke.
Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients
Kang, Daehun , In, Myung‐Ho , Halverson, Maria, Meyer, Nolan , Ahmed, Zaki , Gray, Erin M. , Fernandez, Brice , Black, David F. , Welker, Kirk M. , Trzasko, Joshua D. , Huston, John , Shu, Yunhong , Huston, John , Halverson, Maria A, Meyer, Nolan K , Ahmed, Zaki , Fernandez, Brice , Shu, Yunhong , Kang, Daehun , In, Myung-Ho , Jo, Hang Joon , Madhavan, Radhika , Foo, Thomas , Bernstein, Matt A.

Sensors | April 28, 2023 | Volume: 23 | Issue: 9 | Pages: 4329

10.3390/s23094329 | PMID 37177534 Get It

In blood-oxygen-level-dependent (BOLD)-based resting-state functional (RS-fMRI) studies, usage of multi-echo echo-planar-imaging (ME-EPI) is limited due to unacceptable late echo times when high spatial resolution is used. Equipped with high-performance gradients, the compact 3T MRI system (C3T) enables a three-echo whole-brain ME-EPI protocol with smaller than 2.5 mm isotropic voxel and shorter than 1 s repetition time, as required in landmark fMRI studies. The performance of the ME-EPI was comprehensively evaluated with signal variance reduction and region-of-interest-, seed- and independent-component-analysis-based functional connectivity analyses and compared with a counterpart of single-echo EPI with the shortest TR possible. Through the multi-echo combination, the thermal noise level is reduced. Functional connectivity, as well as signal intensity, are recovered in the medial orbital sulcus and anterior transverse collateral sulcus in ME-EPI. It is demonstrated that ME-EPI provides superior sensitivity and accuracy for detecting functional connectivity and/or brain networks in comparison with single-echo EPI. In conclusion, the high-performance gradient enabled high-spatial-temporal resolution ME-EPI would be the method of choice for RS-fMRI study on the C3T.