Citations

Mayo Clinic

Clear

2819 citation(s) found for "C, Liu".

Genetic Polymorphisms and Correlation with Treatment-Induced Cardiotoxicity and Prognosis in Patients with Breast Cancer
Peddi, Parvin F., Fasching, Peter A. , Liu, Duan , Quinaux, Emmanuel, Robert, Nicholas J., Valero, Vicente, Falkson, Carla I. , Brufsky, Adam , Cunningham, Julie M. , Weinshilboum, Richard M., Pienkowski, Tadeusz, Eiermann, Wolfgang, Bee, Valerie, Wang, Xiaoyan, Wang, Liewei, Yang, Eric H. , Slamon, Dennis J., Hurvitz, Sara A., Pieńkowski, Tadeusz , Crown, John , Falkson, Carla , Brufsky, Adam M , Cunningham, Julie M , Martin, Miguel , Yang, Eric , Liu, Duan , Peddi, Parvin F., Fasching, Peter A , Quinaux, Emmanuel, Robert, Nicholas J., Valero, Vicente, Weinshilboum, Richard M., Eiermann, Wolfgang, Bee, Valerie, Wang, Xiaoyan, Wang, Liewei, Slamon, Dennis J., Hurvitz, Sara A.

Clinical Cancer Research | February 2, 2022 | Volume: 28 | Issue: 9 | Pages: 1854-1862

10.1158/1078-0432.ccr-21-1762 | PMID 35110416 Get It

Abstract Purpose: Cardiac toxicity is a serious potential complication of HER2-directed therapies and anthracyclines. HER2 codon 655 and SLC28A3 gene polymorphisms have been reported to be associated with cardiac toxicity from anti-HER2 and anthracycline therapy, respectively. Association of the polymorphism at HER2 codon 655 with prognosis has also been reported. Experimental Design: Whole blood samples from patients treated on a randomized adjuvant breast cancer trial (BCIRG-006) that compared chemotherapy with or without trastuzumab plus either anthracycline or nonanthracycline chemotherapy were tested for genetic polymorphisms in HER2 codon 655 and SLC28A3. Genotypes were correlated with cardiac function and disease-free survival (DFS) outcomes. Results: Of 3,222 patients enrolled in BCIRG-006, 662 patient samples were successfully genotyped for the rs1136201 allele in HER2 (codon 655): 424 (64%) were AA, 30 (4.5%) were GG, and 208 (31%) were AG genotype. In addition, 665 patient samples were successfully genotyped for the rs7853758 allele in the SLC28A3 gene: 19 (3%) were AA, 475 (71%) were GG, and 171 (26%) were AG genotype. Follow-up time was 10 years. No correlation between DFS, cardiac event rate, or mean left ventricular ejection fraction (LVEF) and rs1136201 genotype was seen in the trastuzumab-treated or non–trastuzumab-treated patients. Moreover, mean LVEF and cardiac event rates were similar in all rs7853758 genotype groups treated with anthracycline-based therapy. Conclusions: In the largest study to date to evaluate whether two polymorphisms are associated with DFS and/or cardiac toxicity in HER2-positive breast cancer treated with trastuzumab and/or anthracyclines, we observed no correlation.
Genome-wide interaction analysis identified low-frequency variants with sex disparity in lung cancer risk
Li, Yafang , Xiao, Xiangjun , Cheng, Chao , McKay, James , Lam, Stephen , Tardón, Adonina , Chen, Chu, Bojesen, Stig E. , Landi, Maria Teresa , Risch, Angela , Wichmann, H‐Erich, Rennert, Gad , Goodman, Gary E. , Field, John K. , Davies, Michael P.A. , Shete, Sanjay , Melander, Olle , Brunnström, Hans , Hung, Rayjean J, Andrew, Angeline S. , Shen, Hongbing , Zienolddiny, Shan, Grankvist, Kjell , Johansson, Mikael , Caporaso, Neil E. , Aldrich, Melinda C. , Schwartz, Ann G. , Gorlov, Ivan P. , Purrington, Kristen S. , Bailey‐Wilson, Joan E. , Mandal, Diptasri , Willey, James C. , Gaba, Colette , Brennan, Paul , Hung, Rayjean J. , Rennert, Gad , Cheng, Chao , Wilson, Richard K , Hung, Rayjean J , Field, John K , Tardón, Adonina , Davies, Michael P A , Bojesen, Stig E , Risch, Angela , Grankvist, Kjell , Purrington, Kristen S , Willey, James C , Shen, Hongbing , Li, Jianrong , Byun, Jinyoung , Bossé, Yohan , Albanes, Demetrius , Johansson, Mattias , Bickeböller, Heike , Christiani, David C. , Arnold, Susanne M. , Marchand, Loı̈c Le , Liu, Geoffrey , Kiemeney, Lambertus A. , Sun, Ryan , Teare, M. Dawn , Hong, Yun‐Chul , Lazarus, Philip J. , Schabath, Matthew B. , Yang, Ping , Liu, Yanhong , Han, Younghun , Pinney, Susan M. , Amos, Christopher I.

Human Molecular Genetics | February 1, 2022 | Volume: 31 | Issue: 16 | Pages: 2831-2843

10.1093/hmg/ddac030 | PMID 35138370 Get It

Abstract Differences by sex in lung cancer incidence and mortality have been reported which cannot be fully explained by sex differences in smoking behavior, implying existence of genetic and molecular basis for sex disparity in lung cancer development. However, the information about sex dimorphism in lung cancer risk is quite limited despite the great success in lung cancer association studies. By adopting a stringent two-stage analysis strategy, we performed a genome-wide gene–sex interaction analysis using genotypes from a lung cancer cohort including ~ 47 000 individuals with European ancestry. Three low-frequency variants (minor allele frequency < 0.05), rs17662871 [odds ratio (OR) = 0.71, P = 4.29×10−8); rs79942605 (OR = 2.17, P = 2.81×10−8) and rs208908 (OR = 0.70, P = 4.54×10−8) were identified with different risk effect of lung cancer between men and women. Further expression quantitative trait loci and functional annotation analysis suggested rs208908 affects lung cancer risk through differential regulation of Coxsackie virus and adenovirus receptor gene expression in lung tissues between men and women. Our study is one of the first studies to provide novel insights about the genetic and molecular basis for sex disparity in lung cancer development.
Lack of defined apheresis collection criteria in publicly available CAR‐T cell clinical trial descriptions: Comprehensive review of over 600 studies
Thibodeaux, Suzanne R. , Aqui, Nicole A., Park, Yara A. , Su, Leon , Zubair, Abba C. , Liu, Hien , Su, Leon L , Zubair, Abba C , Schneiderman, Jennifer , Winters, Jeffrey L. , Schwartz, Joseph

Journal of Clinical Apheresis | January 27, 2022 | Volume: 37 | Issue: 3 | Pages: 223-236

10.1002/jca.21964 | PMID 35085413 Get It

AbstractBackgroundChimeric antigen receptor T (CAR‐T) cell successes have encouraged continued clinical study. Apheresis collection of starting material for CAR‐T cell therapy product manufacturing is critical but described approaches suggest variability and clinical guidelines are currently lacking. The goal of this study was to gather and assess variability in apheresis collection descriptions in publicly available CAR T‐cell therapy clinical trials.Study designWe searched clinicaltrials.gov (a publicly available clinical trial database) for “chimeric antigen receptor T cells” on July 01, 2020 and studies accessed July 30, 2020‐August 15, 2020. Data collected included date posted, study characteristics, apheresis mentions (number, location, and context), laboratory parameters and transfusion allowances. Apheresis context was analyzed using a qualitative inductive approach of grounded theory method with open coding. Text was classified into 37 context codes, grouped into 12 categories, and then consolidated into patient, procedure, product, and miscellaneous themes.ResultsApheresis was mentioned 1044 times in 322 (51.9%) of 621 total studies. Laboratory parameters mentioned included white blood cells (100 studies), absolute neutrophil count (220 studies), absolute lymphocyte count (102 studies), CD3+ cell (38 studies), hemoglobin (233 studies, 54 studies specified transfusion allowance), and platelet (269 studies, 48 studies specified transfusion allowance).ConclusionsApheresis collection of CAR‐T cell products is not well‐defined in clinical study descriptions and the context is inconsistent. Laboratory parameters useful for apheresis collection are variably present and do not consistently align with current practices. Further exploration, and clinical guideline development will encourage alignment of apheresis collections for CAR‐T cell products.
Effectiveness of a multicomponent exercise program to reverse pre-frailty in community-dwelling Chinese older adults: a randomised controlled trial
Dun, Yaoshan , Ripley-Gonzalez, Jeffrey W. , Zhou, Nanjiang , Li, Hui , Zhang, Wenliang , Chen, Meijuan , Zheng, Qingsong , Cui, Ni, Wu, Shaoping , Liu, Suixin , Liu, Suixin , Liu, Suixin , Dun, Yaoshan , Hu, Peng, Zheng, Qingsong

Age and Ageing | January 24, 2022 | Volume: 51 | Issue: 3 | Pages: No page available

10.1093/ageing/afac026 | PMID 35231098 Get It

Abstract Background the Xiangya Hospital circuit training (X-CircuiT), was developed to reverse pre-frailty in Chinese older adults and determine potential mechanisms through which pre-frailty is reversed. Methods this randomised controlled trial was performed at Xiangya Hospital, Changsha, China from September 2020 to May 2021. Forty-eight pre-frail older adults were enrolled. Participants were randomly assigned (1:1) to X-CircuiT (46 min/session, three supervised sessions/week for 3 months at a community health centre) or control (1-time advice on physical activity without supervised exercise). The primary outcome was the proportion of participants with pre-frailty after 3-month intervention. The secondary outcomes included absolute risk reduction (ARR), number needed to treat (NNT), and the changes in senior fitness, body composition and clinical measures. Results among 48 participants (mean age, 72 years; women [65%]), 22 participants in the X-CircuiT (92%) and 21 participants in the control (88%) completed the study. After 3 months, the proportion of pre-frailty was significantly lower in the X-CircuiT group than the control (14% versus 95%, P < 0.001). The ARR and NNT were 82% [95% CI, 65–99] and 1 [1–2], respectively. X-CircuiT was associated with significant improvements in senior fitness indicators and body composition. No significant difference in blood chemistry, carotid ultrasound and echocardiography parameters was found between groups. No significant interaction was detected between sex, BMI, baseline peak oxygen consumption and study groups. Conclusion this study demonstrates that X-CircuiT could significantly reverse pre-frailty in Chinese older adults. The underlying mechanisms may involve X-CircuiT-induced improvements in body composition and senior fitness. The trial is registered at Chictr.org.cn. Number: ChiCTR2100048125.
Scaffold-Free Spheroids with Two-Dimensional Heteronano-Layers (2DHNL) Enabling Stem Cell and Osteogenic Factor Codelivery for Bone Repair
Liu, Xifeng , Gaihre, Bipin , Park, Sungjo , Elder, Benjamin D. , Lu, Lichun , Li, Linli , Lu, Lichun , Li, Yong, Terzic, André

ACS Nano | January 24, 2022 | Volume: 16 | Issue: 2 | Pages: 2741-2755

10.1021/acsnano.1c09688 | PMID 35072461 Get It

ASHP Guidelines on the Safe Use of Automated Compounding Devices for the Preparation of Parenteral Nutrition Admixtures
Iredell, Benjamin, Mourad, Hesham , Nickman, Nancy A. , Dieu, Hao, Austin, Gary, Goradia, Rani, Wade, Joseph Scott, Goette, Justin, Ezekiel, Tanya O, Begnoche, Brendan R, Liu, Andrew , English, Stacey, Austin, Gary, Liu, Andrew

American Journal of Health-System Pharmacy | January 24, 2022 | Volume: 79 | Issue: 10 | Pages: 730-735

10.1093/ajhp/zxac004 | PMID 35072701 Get It

Device‐related infection associated with increased mortality risk in de novo transvenous implantable cardioverter‐defibrillator medicare patients
Liu, Yiyan , Griffiths, Robert I. , Knight, Bradley P. , Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline M., El-Chami, Mikhael F , Weiss, Raul , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | January 23, 2022 | Volume: 33 | Issue: 4 | Pages: 725-730

10.1111/jce.15385 | PMID 35066954 Get It

AbstractIntroductionTransvenous implantable cardioverter‐defibrillators (TV‐ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV‐ICD infection in a large Medicare population with de novo TV‐ICD implants.MethodsA survival analysis was conducted using 100% fee‐for‐service Medicare facility‐level claims data to identify patients who underwent de novo TV‐ICD implantation between 7/2016 and 1/2018. TV‐ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time‐dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.ResultsAmong 26,742 Medicare patients with de novo TV‐ICD, 518 (1.9%) had a device‐related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV‐ICD infection was associated with an increase of 2.4 (95% CI: 2.08–2.85) times in the mortality hazard ratio.ConclusionThe rate of TV‐ICD infection and associated mortality in a large, real‐world Medicare population is noteworthy. The positive association between device‐related infection and risk of mortality further highlights the need to reduce infections
Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices with generator and lead(s) brand mismatch
Minaskeian, Nareg , Hajnal, Sofia Pannunzio, Liu, Michael B. , Klooster, Lindsay, Devick, Katrina L. , Schwartz, Linda, Jokerst, Clinton, Sorajja, Dan , Scott, Luis, Hajnal, Sofia P, Klooster, Lindsay M, Scott, Luis Rp, Schwartz, Linda

Journal of Applied Clinical Medical Physics | January 23, 2022 | Volume: 23 | Issue: 3 | Pages: No page available

10.1002/acm2.13520 | PMID 35066975 Get It

AbstractMagnetic resonance imaging (MRI) is a valuable imaging modality for the assessment of both cardiac and non‐cardiac structures. With a growing population of patients with cardiovascular implantable electronic devices (CIEDs), 50%–75% of these patients will need an MRI. MRI‐conditional CIEDs have demonstrated safety of MRI scanning with such devices, yet non‐conditional devices such as hybrid CIEDs which have generator and lead brand mismatch may pose a safety risk. In this retrospective study, we examined the outcomes of patients with hybrid CIEDs undergoing MRI compared to those patients with non‐hybrid CIEDs. A total of 349 patients were included, of which 24 patients (7%) had hybrid CIEDs. The primary endpoint was the safety of MRI for patients with hybrid CIEDs as compared to those with non‐hybrid devices, measured by the rate of adverse events, including death, lead or generator failure needing immediate replacement, loss of capture, new onset arrhythmia, or power‐on reset. Secondary endpoints consisted of pre‐ and post‐MRI changes of decreased P‐wave or R‐wave sensing by ≥50%, changes in pacing lead impedance by ≥50 ohms, increase in pacing thresholds by ≥ 0.5 V at 0.4 ms, and decreasing battery voltage of ≥ 0.04 V. The primary endpoint of any adverse reaction was present in 1 (4.2%) patient with a hybrid device, and consistent of atrial tachyarrhythmia, and in 10 (3.1%) patients with a non‐hybrid device, and consisted of self‐limited atrial and non‐sustained ventricular arrhythmias; this was not statistically significant. No significant differences were found in the secondary endpoints. This study demonstrates that MRI in patients with hybrid CIEDs does not result in increased patient risk or significant device changes when compared to those patients who underwent MRI with non‐hybrid CIEDs.
P660 Knowledge, attitudes, and awareness of contraceptive choices in women with Inflammatory Bowel Disease
Liu, E, Jatale, Raj, Farraye, Jennifer , Cannon, Rachel , Limdi, J K, Woodhams, Elisabeth J. , Farraye, Francis A.

Journal of Crohn's and Colitis | January 21, 2022 | Volume: 16 | Issue: Supplement_1 | Pages: i571-i571

10.1093/ecco-jcc/jjab232.781 Get It

Abstract Background Active inflammatory bowel disease (IBD) at conception is associated with adverse pregnancy outcomes. Published literature suggests that almost a quarter of women with IBD do not use any form of contraception putting them at risk of unplanned pregnancy. Recent guidelines emphasise the importance of antenatal care in IBD patients, but contraception counselling and risk assessment are not addressed. Our aim was to explore the contraceptive knowledge, attitudes and preferences of women with IBD. Methods A 34-item questionnaire was prospectively administered to 245 consecutive female IBD patients aged 18–45 attending gastroenterology clinics. Disease control was measured using the validated IBD Control questionnaire, and contraceptive preferences assessed by the Contraceptive Features Survey. Results Of the 245 participants (see table 1), mean disease duration was 6.5 years, median IBD control score was 16.9 (range 0- 26), and 152 (62%) respondents had previously been pregnant. Almost three quarters of respondents (n=176) reported currently using contraception, and 41 (17%) were using highly effective contraceptives. The most commonly used contraceptives were oral birth control pills (27%) and barrier methods (18%). Participants who identified as Caucasian (74%) were more likely than those who identified as Asian (37%) to use contraception (p=0.0009). Patients who did not plan to conceive in the future were more likely to use contraception (p=0.0365). However, of the 58% (n=143) who had either no plans to conceive in the future or were unsure, 23% were not using any form of contraception, and 83% were not using a highly effective contraceptive. Current biologic therapy was significantly associated with highly effective contraceptive use (p=0.0275). Contraceptive features most important to women were effectiveness (78%), ease of use (76%), few or no side effects (68%) and not detracting from sexual enjoyment (65%). Only 25% patients (n=61) recalled discussing reproductive issues with their IBD clinician, however, 86% stated they would feel comfortable having this discussion. Women wished to receive family planning counselling from their IBD nurse (81%), General practitioner (77%), IBD doctor (68%), and gynaecologist (47%). Conclusion A quarter of patients in our cohort were not using any contraception and the majority were not using a highly effective form potentially increasing their risk of unplanned or mistimed pregnancy. Participants desired a contraceptive that was effective, easy to use and with minimal side effects. Our findings reflect the need for further studies to improve informed decision making with contraceptive counselling, to improve the overall quality of care for women with IBD.
RBE‐weighted dose and its impact on the risk of acute coronary event for breast cancer patients treated with intensity modulated proton therapy
Liu, Chunbo , Bradley, Julie A. , Beltran, Chris , Beltran, Chris J., Beltran, Chris J , Zheng, Dandan , Vega, Raymond B. Mailhot , Mendenhall, Nancy P. , Liang, Xiaoying

Journal of Applied Clinical Medical Physics | January 21, 2022 | Volume: 23 | Issue: 4 | Pages: No page available

10.1002/acm2.13527 | PMID 35060317 Get It

AbstractPurposeTo evaluate the relative biological effectiveness (RBE)‐weighted dose to the heart and to estimate RBE uncertainties when assuming a constant RBE of 1.1, for breast cancer patients receiving intensity‐modulated proton therapy (IMPT). Further, to study the impact of RBE uncertainties on the risk of an acute coronary event (ACE).Material and methodsWe analyzed 20 patients who received IMPT to either the left breast (n = 10) or left chest wall (n = 10) and regional lymph nodes. The Monte Carlo simulation engine, MCsquare, was used to simulate the dose‐averaged linear energy transfer (LETd) map. The RBE‐weighted dose to the heart and its substructures was calculated using three different RBE models. The risk of ACE was estimated per its linear relationship with mean heart dose (MHD) as established by Darby et al.ResultsThe median MHD increased from 1.33 GyRBE assuming an RBE of 1.1 to 1.64, 1.87, and 1.99 GyRBE when using the RBE‐weighted dose models. The median values (and ranges) of the excess absolute risk of ACE were 0.4% (0.1%–0.8%) when assuming an RBE of 1.1, and 0.6% (0.2%–1.0%), 0.6% (0.2%–1.1%), and 0.7% (0.2%–1.1%) with the RBE‐weighted models. For our patient cohort, the maximum excess absolute risk of ACE increased by 0.3% with the RBE‐weighted doses compared to the constant RBE of 1.1, reaching an excess absolute ACE risk of 1.1%. The interpatient LETd variation was small for the relevant high‐dose regions of the heart.ConclusionAll three RBE models predicted a higher biological dose compared to the clinical standard dose assuming a constant RBE of 1.1. An underestimation of the biological dose results in underestimation of the ACE risk. Analyzing the voxel‐by‐voxel biological dose and the LET map alongside clinical outcomes is warranted in the development of a more accurate normal‐tissue complication probability model.