Back to Authors

Minaskeian, Nareg

https://orcid.org/0000-0003-4343-0636

Mayo Clinic

Mayo Clinic in Arizona

Citations 3

Combined Endocardial and Epicardial Ablation of Drug-Refractory Ventricular Tachycardia by Direct Ventricular Puncture
Ashraf, Hasan , Minaskeian, Nareg , Sell‐Dottin, Kristen , Sell-Dottin, Kristen A , Ashraf, Hasan , Masry, Hicham El

No container title available | January 30, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.170666172.22783228/v1 Get It

Mechanical valves in both aortic and mitral positions pose a challenge for left ventricular (LV) access during ventricular tachycardia (VT) ablation using the antegrade transseptal or the retrograde transaortic approach. A 57 year-old male with ischemic cardiomyopathy, mechanical aortic and mitral valves, and recurrent VT underwent a combined endocardial and epicardial ablation via direct ventricular puncture via mini-thoracotomy. Successful mapping with endocardial and epicardial ablation was performed, with no recurrent VT on follow up. We showcase the feasibility of VT ablation using an open transapical approach for patients with mechanical aortic and mitral valves.
Abstract 9796: Atypical Right Atrial Flutter with Double Loop Reentry Involving the Cavotricuspid Isthmus and Superior Vena Cava with Successful Ablation
Minaskeian, Nareg , Javaid, Awad , Khetarpal, Banveet Kaur , Srivathsan, Komandoor

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.9796 Get It

Introduction: Atrial flutter (AFL) with figure-of-eight reentry (FOER) is effectively terminated by catheter ablation (CA) of the shared isthmus. Case: A 50-year-old man with prior mitral valve (MV) repair presented to our hospital with palpitations for 9 months refractory to metoprolol. ECG showed coarse atrial fibrillation at 61 bpm. Echocardiography showed left ventricular LVEF of 45%. Electrophysiology study revealed AFL (cycle length, TCL 290 msec) with a concentric activation pattern on the coronary sinus (CS) catheter, and a chevron pattern on the Halo catheter placed against the lateral tricuspid annulus (TA). Entrainment map revealed a near equal post-pacing interval and TCL in proximal CS, low lateral right atrium (RA), and CTI. Incomplete line of block was noted in the anterior wall of RA near the superior vena cava (SVC), likely from prior atriotomy scar. Double loop reentry (DLR) was demonstrated with one wavefront (WV) traveling counterclockwise around the TA using the CTI, and the other WV traveling posteriorly around the SVC (Figure). After CTI ablation, TCL changed from 290 msec to 330 msec suggesting blocked CTI. Now, the WV was a single loop around the SVC, confirmed by repeat activation mapping. Linear ablation from anterior TA to the anterior aspect of the SVC terminated the AFL. Differential pacing from either side of the anterior line and the CTI demonstrated a conduction time of > 200 msec and 150 msec in either direction, respectively. Decremental atrial pacing was unable to induce any arrhythmias. Discussion: FOER in this case is suggested by fusion of WVs in the lateral RA. The 2 circuits each had their own conduction gap, in the CTI and anterior RA wall near the SVC, respectively. DLR was proven by entrainment as well as activation mapping. The faster CTI-dependent AFL was entraining the upper loop reentry circuit. Conclusion: Atypical right AFL with DLR mimicking FOER was successfully terminated by CA of CTI and anterior line of ablation from TA to SVC.
Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices with generator and lead(s) brand mismatch
Minaskeian, Nareg , Hajnal, Sofia Pannunzio, Liu, Michael B. , Klooster, Lindsay, Devick, Katrina L. , Schwartz, Linda, Jokerst, Clinton, Sorajja, Dan , Scott, Luis, Hajnal, Sofia P, Klooster, Lindsay M, Scott, Luis Rp, Schwartz, Linda

Journal of Applied Clinical Medical Physics | January 23, 2022 | Volume: 23 | Issue: 3 | Pages: No page available

10.1002/acm2.13520 Get It

AbstractMagnetic resonance imaging (MRI) is a valuable imaging modality for the assessment of both cardiac and non‐cardiac structures. With a growing population of patients with cardiovascular implantable electronic devices (CIEDs), 50%–75% of these patients will need an MRI. MRI‐conditional CIEDs have demonstrated safety of MRI scanning with such devices, yet non‐conditional devices such as hybrid CIEDs which have generator and lead brand mismatch may pose a safety risk. In this retrospective study, we examined the outcomes of patients with hybrid CIEDs undergoing MRI compared to those patients with non‐hybrid CIEDs. A total of 349 patients were included, of which 24 patients (7%) had hybrid CIEDs. The primary endpoint was the safety of MRI for patients with hybrid CIEDs as compared to those with non‐hybrid devices, measured by the rate of adverse events, including death, lead or generator failure needing immediate replacement, loss of capture, new onset arrhythmia, or power‐on reset. Secondary endpoints consisted of pre‐ and post‐MRI changes of decreased P‐wave or R‐wave sensing by ≥50%, changes in pacing lead impedance by ≥50 ohms, increase in pacing thresholds by ≥ 0.5 V at 0.4 ms, and decreasing battery voltage of ≥ 0.04 V. The primary endpoint of any adverse reaction was present in 1 (4.2%) patient with a hybrid device, and consistent of atrial tachyarrhythmia, and in 10 (3.1%) patients with a non‐hybrid device, and consisted of self‐limited atrial and non‐sustained ventricular arrhythmias; this was not statistically significant. No significant differences were found in the secondary endpoints. This study demonstrates that MRI in patients with hybrid CIEDs does not result in increased patient risk or significant device changes when compared to those patients who underwent MRI with non‐hybrid CIEDs.