Back to Authors

Khetarpal, Banveet Kaur

https://orcid.org/0000-0002-4205-4969

Mayo Clinic

University of Nevada, Las Vegas

Citations 7

Abstract 14356: Trends of Acute Myocardial Infarction Mortality Rates in the United States From 1999-2019: A Retrospective Study
Venepally, Nithin R. , Dang, Thao, Sierra, Juan, Bakhati, Bibek, Sai, Mungara, Jha, Govind Kumar , Agasthi, Pradyumna , Matute, Carlos , Khetarpal, Banveet Kaur , Jha, Govind, Arsanjani, Reza

Circulation | April 23, 2024 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.14356 Get It

Introduction: In the current study, we examined the temporal trends in mortality across gender, race, and 10-year age groups over last two-decades. Methods: We conducted a retrospective population-based study using Centers for Disease Control and Prevention database. Subjects with underlying cause of death from AMI were identified using validated ICD10 codes. Age adjusted mortality rates were calculated for gender and race whereas crude rates were calculated for 10-year age group. Using Poisson regression, we estimated the rate ratio between race/ethnicity pairs adjusting for age and sex in order to analyze temporal trend. Results: We identified 2,709,173 subjects with reported underlying cause of death as AMI between January-2000 to December-2019 of which 54.7% were males (n=1,483,163). The age adjusted mortality rate per 100,000 was higher in males compared to females (52.4% vs 30.7%, OR: 1.66 [1.45-1.89]). Among ethnicities African American (AA) population had the highest age adjusted mortality rate per 100,000 [Table 1]. As expected, age group >85 years had the highest mortality rate per 100,000 constituting 30% of total deaths (78% of total deaths were noted in >65yr age group). AMI age adjusted mortality rates/100,000 showed significant decline across gender and race with highest decline in female population (66.5% decline). Highest percentage decline in mortality was noted in AA female population (68.2%) whereas in males it was the white population (62%). In females, highest percentage decline in mortality was noted in 75-84 age-group (70%) while it was >85 age-group (67%) in males. Conclusion: Over last two decades there has been a significant decline in AMI mortality rates across gender and race. AA continue to have higher age adjusted mortality rate among both male and female population (38% and 22% respectively). Further studies are needed to identify and provide targeted prevention and intervention strategies in high-risk populations.
Challenges of atrial fibrillation and atrial flutter ablation in patients with pectus excavatum
Iyengar, Sumedh , Reddy, Sudeepthi, Khetarpal, Banveet Kaur , Elzamar, Mohamed, Srivathsan, Komandoor

Pacing and Clinical Electrophysiology | August 19, 2023 | Volume: 47 | Issue: 5 | Pages: 668-672

10.1111/pace.14805 Get It

Abstract Atrial fibrillation (AF) may be associated with chest wall abnormalities such as pectus excavatum (PE). Pulmonary vein isolation (PVI) has proven to be a useful strategy for radiofrequency catheter ablation (RFCA) of AF. However, the presence of chest wall abnormalities, such as pectus excavatum, imposes certain challenges during ablation due to the anatomic distortion that it causes. We highlight these challenges during ablation in this three‐patient case series.
Subcutaneous implantable cardioverter‐defibrillator noise following left ventricular assist device implantation
Khetarpal, Banveet Kaur , Javaid, Awad , Lee, Justin Z. , Mulpuru, Siva K. , Sorajja, Dan , Cha, Yong‐Mei , Mulpuru, Siva K , Kusumoto, Fred , Srivathsan, Komandoor

Journal of Arrhythmia | February 13, 2023 | Volume: 39 | Issue: 2 | Pages: 198-206

10.1002/joa3.12826 Get It

AbstractBackgroundThe incidence and impact of noise in a subcutaneous implantable cardioverter defibrillator (S‐ICD) after left ventricular assist device (LVAD) implantation is not well established.MethodsWe performed a retrospective study of patients implanted with LVAD and with a pre‐existing S‐ICD between January 2005 and December 2020 at the three Mayo Clinic centers (Minnesota, Arizona, and Florida).ResultsOf the 908 LVAD patients, a pre‐existing S‐ICD was present in 9 patients (mean age 49.1 ± 13.7 years, 66.7% males), 100% with Boston Scientific third‐generation EMBLEM MRI S‐ICD, 11% with HeartMate II (HM II), 44% with HeartMate 3 (HM 3), and 44% with HeartWare (HW) LVAD. The incidence of noise from LVAD‐related electromagnetic interference (EMI) was 33% and was only seen with HM 3 LVAD. Multiple measures attempted to resolve noise, including using alternative S‐ICD sensing vector, adjusting S‐ICD time zone, and increasing LVAD pump speed, were unsuccessful, necessitating S‐ICD device therapies to be turned off permanently.ConclusionsThe incidence of LVAD‐related S‐ICD noise is high in patients with concomitant LVAD and S‐ICD with significant impact on device function. As conservative management failed to resolve the EMI, the S‐ICDs had to be programmed off to avoid inappropriate shocks. This study highlights the importance of awareness of LVAD‐SICD device interference and the need to improve S‐ICD detection algorithms to eliminate noise.
Abstract 9796: Atypical Right Atrial Flutter with Double Loop Reentry Involving the Cavotricuspid Isthmus and Superior Vena Cava with Successful Ablation
Minaskeian, Nareg , Javaid, Awad , Khetarpal, Banveet Kaur , Srivathsan, Komandoor

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.9796 Get It

Introduction: Atrial flutter (AFL) with figure-of-eight reentry (FOER) is effectively terminated by catheter ablation (CA) of the shared isthmus. Case: A 50-year-old man with prior mitral valve (MV) repair presented to our hospital with palpitations for 9 months refractory to metoprolol. ECG showed coarse atrial fibrillation at 61 bpm. Echocardiography showed left ventricular LVEF of 45%. Electrophysiology study revealed AFL (cycle length, TCL 290 msec) with a concentric activation pattern on the coronary sinus (CS) catheter, and a chevron pattern on the Halo catheter placed against the lateral tricuspid annulus (TA). Entrainment map revealed a near equal post-pacing interval and TCL in proximal CS, low lateral right atrium (RA), and CTI. Incomplete line of block was noted in the anterior wall of RA near the superior vena cava (SVC), likely from prior atriotomy scar. Double loop reentry (DLR) was demonstrated with one wavefront (WV) traveling counterclockwise around the TA using the CTI, and the other WV traveling posteriorly around the SVC (Figure). After CTI ablation, TCL changed from 290 msec to 330 msec suggesting blocked CTI. Now, the WV was a single loop around the SVC, confirmed by repeat activation mapping. Linear ablation from anterior TA to the anterior aspect of the SVC terminated the AFL. Differential pacing from either side of the anterior line and the CTI demonstrated a conduction time of > 200 msec and 150 msec in either direction, respectively. Decremental atrial pacing was unable to induce any arrhythmias. Discussion: FOER in this case is suggested by fusion of WVs in the lateral RA. The 2 circuits each had their own conduction gap, in the CTI and anterior RA wall near the SVC, respectively. DLR was proven by entrainment as well as activation mapping. The faster CTI-dependent AFL was entraining the upper loop reentry circuit. Conclusion: Atypical right AFL with DLR mimicking FOER was successfully terminated by CA of CTI and anterior line of ablation from TA to SVC.
Electromagnetic interference from left ventricular assist device in patients with transvenous implantable cardioverter‐defibrillator
Khetarpal, Banveet Kaur , Lee, Justin Z. , Javaid, Awad , Mi, Lanyu , Venepally, Nithin R. , Narasimhan, Bharat , Hardaway, Brian , Cha, Yong‐Mei , Kusumoto, Fred , Mulpuru, Siva K. , Hardaway, Brian W, Kusumoto, Fred M , Srivathsan, Komandoor

Pacing and Clinical Electrophysiology | May 12, 2021 | Volume: 44 | Issue: 7 | Pages: 1163-1175

10.1111/pace.14265 Get It

AbstractBackgroundMany advanced heart failure patients have both a left ventricular assist device (LVAD) and an implantable cardioverter‐defibrillator (ICD). This study examines incidence, clinical impact, and management of LVAD‐related EMI.MethodsWe performed a three‐center retrospective analysis of transvenous ICD implanted patients with LVAD implanted between January 1, 2005 and December 31, 2020. The primary outcome was EMI after LVAD implantation, categorized as LVAD‐related noise or telemetry interference.ResultsThe rate of LVAD‐related EMI among the 737 patients (mean age 58.6 ± 12.8 years) studied was 5.0%. Telemetry interference (1.5%) compromised ICD interrogation in all patients. This was resolved successfully with use of a metal shield, encased wand, radiofrequency tower, different ICD programmer or by increasing distance between ICD programmer and LVAD (n = 6). ICD replacement was required to reestablish successful communication in three patients. LVAD‐related noise (3.5%) led to oversensing (n = 4), inappropriate mode switches (n = 4), noise reversion (n = 3), inhibition of pacing (n = 2), inappropriate detection as atrial fibrillation (AF) (n = 2) and inappropriate detection as ventricular tachycardia (VT) and/or ventricular fibrillation (VF) (n = 2). This noise interference persisted (n = 3), resolved spontaneously (n = 16), resolved with programming change (n = 6) or required lead revision (n = 1).ConclusionsEMI from LVAD impacts ICD function, although, the incidence rate is low. Physicians implanting both, LVAD in patients with ICD (more common) or ICD in patients with LVAD, should be aware of possible interferences. Telemetry failure not resolved by metal shielding was overcome by ICD generator replacement to a different manufacturer. In most cases, LVAD‐related noise resolves spontaneously.
P339 Gradient adjusted cardiac power index does not improve prediction of survival post transcatheter aortic valve replacement compared to cardiac power index alone
Mookadam, Farouk , Venepally, Nithin R. , Wang, P, Khetarpal, Banveet Kaur , Sweeney, Joseph C. , Eleid, M, Pollak, Peter , Fortuin, F. David , Holmes, David R. , Agasthi, Pradyumna , Mookadam, Farouk , Sweeney, J, Arsanjani, Reza

European Heart Journal - Cardiovascular Imaging | January 17, 2020 | Volume: 21 | Issue: Supplement_1 | Pages: No page available

10.1093/ehjci/jez319.192 Get It

Abstract Funding Acknowledgements None Background Cardiac Power Index (CPI) is an integrative hemodynamic measure of cardiac pumping capability and is the product of the simultaneously measured mean arterial pressure (MAP) and cardiac output (CO). In patients with aortic stenosis (AS), MAP is not reflective of mean systolic left ventricular (LV) pressure due to the transvalvular gradient. Non-invasive assessment of mean systolic LV pressure is challenging in severe aortic stenosis. CPI assessed using systemic MAP was previously shown to predict survival post transcatheter aortic valve replacement (TAVR). Purpose We evaluated the utility of a gradient adjusted CPI in predicting survival post TAVR compared to CPI alone Methods A retrospective study was performed including patients undergoing TAVR with 1 year follow-up. Baseline demographics, clinical, and echocardiographic data were abstracted from a cohort of 1,011 patients. CPI was calculated, (CO x MAP)/ (451 x BSA) Watts/m2. Gradient adjusted CPI was calculated using an augmented MAP i) adding aortic valve mean gradient(AVMG) to systolic blood pressure (CPI1); ii) adding aortic valve maximal instantaneous gradient to systolic blood pressure (CPI2) and iii) adding AVMG to MAP (CPI3). Patient survival score was calculated using a step up technique to identify the cut off value for CPI and gradient adjusted CPI to identify, where the maximum difference in mortality occurred. Multivariate cox-regression analysis was performed to adjust for baseline covariates. Receiver operator curves(ROC) for CPI and gradient adjusted CPI were calculated to predict survival post TAVR. Results The mortality rate at 1 yr was 16%. Mean age and AVMG of survivors was 81 +/- 9 yrs and 43 +/-14 mmHg vs 80 +/-9 yrs and 42 +/- 13 mmHg in the deceased group. Proportion of female patients was similar in both groups (p = 0.7). Patients in the deceased group at baseline had a higher prevalence of chronic lung disease, atrial fibrillation, heart failure within 2-weeks of procedure, higher STS-PROM score, lower serum albumin level, higher prevalence of moderate to severe tricuspid regurgitation, higher right ventricular systolic pressure and higher prevalence of dialysis. Both CPI and gradient adjusted CPI were independently associated with survival at 1 year. The area under ROC for CP, CP1, CP2 and CP3 were 0.67 (95% confidence interval [CI] 0.62 - 0.72), 0.65 (95% CI 0.60 – 0.70), 0.66 (95% CI 0.61 – 0.71) and 0.63 (95% CI 0.58 – 0.68) respectively. Conclusion Gradient adjusted CPI did not improve accuracy of predicting post TAVR survival at 1 year compared to CPI alone. Abstract P339 Figure. Area under ROC
Early fluctuations in busulfan levels with therapeutic dose monitoring during allogeneic stem cell transplantation: do they matter?
Jain, Tania , Khetarpal, Banveet Kaur , McCallen, Margaret, Betcher, Jeffrey, Ofori, Henry , Khera, Nandita , Slack, James L., Leis, José F., Sproat, Lisa Z., Noël, Pierre, Palmer, Jeanne , Kunze, Katie L. , Khetarpal, Banveet K, McCallen, Margaret R, Betcher, Jeffrey A, Ofori, Henry T, Jain, Tania

Leukemia & Lymphoma | January 10, 2019 | Volume: 60 | Issue: 8 | Pages: 2034-2041

10.1080/10428194.2018.1562183 Get It