Introduction: In the current study, we examined the temporal trends in mortality across gender, race, and 10-year age groups over last two-decades. Methods: We conducted a retrospective population-based study using Centers for Disease Control and Prevention database. Subjects with underlying cause of death from AMI were identified using validated ICD10 codes. Age adjusted mortality rates were calculated for gender and race whereas crude rates were calculated for 10-year age group. Using Poisson regression, we estimated the rate ratio between race/ethnicity pairs adjusting for age and sex in order to analyze temporal trend. Results: We identified 2,709,173 subjects with reported underlying cause of death as AMI between January-2000 to December-2019 of which 54.7% were males (n=1,483,163). The age adjusted mortality rate per 100,000 was higher in males compared to females (52.4% vs 30.7%, OR: 1.66 [1.45-1.89]). Among ethnicities African American (AA) population had the highest age adjusted mortality rate per 100,000 [Table 1]. As expected, age group >85 years had the highest mortality rate per 100,000 constituting 30% of total deaths (78% of total deaths were noted in >65yr age group). AMI age adjusted mortality rates/100,000 showed significant decline across gender and race with highest decline in female population (66.5% decline). Highest percentage decline in mortality was noted in AA female population (68.2%) whereas in males it was the white population (62%). In females, highest percentage decline in mortality was noted in 75-84 age-group (70%) while it was >85 age-group (67%) in males. Conclusion: Over last two decades there has been a significant decline in AMI mortality rates across gender and race. AA continue to have higher age adjusted mortality rate among both male and female population (38% and 22% respectively). Further studies are needed to identify and provide targeted prevention and intervention strategies in high-risk populations.
Abstract TMP81: Artificial Intelligence Beats Conventional Regression Analysis in Predicting Short and Long Term Risk of Stroke in Patients Undergoing Percutaneous Coronary Interventions
Introduction: Ischemic stroke (IS) causes substantial morbidity and mortality in patients undergoing percutaneous coronary intervention (PCI) with a 5 yr incidence ~ 3%. We sought the test the accuracy of Machine learning (ML) algorithms in predicting IS in patients undergoing PCI. Methods: Mayo Clinic CathPCI registry data were retrospectively analyzed from Jan 2003 - June 2018 including 21,872 patients who underwent PCI. The cohort was randomly divided into a training sample (75%, n=16404) and a unique test sample (25%, n=5468) prior to model generation. The risk prediction model was generated utilizing a random forest algorithm (RF model) on 188 unique variables to predict the risk of IS at 6-month, 1, 2, and 5-year post PCI. Conventional risk factors for stroke were used for logistic regression. The receiver operating characteristic (ROC) curve and area under the curve for the RF and logistic regression models were compared for the test cohort. Results: The mean age was 66.9 ± 12.4 years, and 71% were male. Patient demographics and outcomes are shown in Table 1 . The ROC area under the curve for the RF model was superior compared to the logistic regression model in predicting IS at 6 months, 1,2 and 5 yrs for the test cohort ( Figure 1 .) Conclusions: The RF model accurately predicts short and long term risk of IS and outperforms logistic regression analysis in patients undergoing PCI.
Electromagnetic interference from left ventricular assist device in patients with transvenous implantable cardioverter‐defibrillator
AbstractBackgroundMany advanced heart failure patients have both a left ventricular assist device (LVAD) and an implantable cardioverter‐defibrillator (ICD). This study examines incidence, clinical impact, and management of LVAD‐related EMI.MethodsWe performed a three‐center retrospective analysis of transvenous ICD implanted patients with LVAD implanted between January 1, 2005 and December 31, 2020. The primary outcome was EMI after LVAD implantation, categorized as LVAD‐related noise or telemetry interference.ResultsThe rate of LVAD‐related EMI among the 737 patients (mean age 58.6 ± 12.8 years) studied was 5.0%. Telemetry interference (1.5%) compromised ICD interrogation in all patients. This was resolved successfully with use of a metal shield, encased wand, radiofrequency tower, different ICD programmer or by increasing distance between ICD programmer and LVAD (n = 6). ICD replacement was required to reestablish successful communication in three patients. LVAD‐related noise (3.5%) led to oversensing (n = 4), inappropriate mode switches (n = 4), noise reversion (n = 3), inhibition of pacing (n = 2), inappropriate detection as atrial fibrillation (AF) (n = 2) and inappropriate detection as ventricular tachycardia (VT) and/or ventricular fibrillation (VF) (n = 2). This noise interference persisted (n = 3), resolved spontaneously (n = 16), resolved with programming change (n = 6) or required lead revision (n = 1).ConclusionsEMI from LVAD impacts ICD function, although, the incidence rate is low. Physicians implanting both, LVAD in patients with ICD (more common) or ICD in patients with LVAD, should be aware of possible interferences. Telemetry failure not resolved by metal shielding was overcome by ICD generator replacement to a different manufacturer. In most cases, LVAD‐related noise resolves spontaneously.
Comparison of echocardiographic parameters with cardiac magnetic resonance imaging in the assessment of right ventricular function
AbstractIntroductionThe right ventricle (RV) strain measured by speckle tracking (RVS) is an echocardiographic parameter used to assess RV function. We compared RVS to RV fractional area change (FAC%), tricuspid annular plane systolic excursion (TAPSE) and Doppler tissue imaging‐derived peak systolic velocity (Sʹ) in the assessment of right ventricular (RV) systolic function measured using cardiac magnetic resonance imaging (MRI).MethodsWe enrolled consecutive patients who underwent cardiac MRI between Jan 2012 and Dec 2017 and a transthoracic echocardiogram (TTE) within 1 month of the MRI with no interval event. Baseline clinical characteristics and MRI parameters were extracted from chart review. Echocardiographic parameters were measured prospectively. TTE parameters including RVS, TAPSE, Sʹ, and FAC% were tested for accuracy to identify impaired RV EF (EF < 45% & <30%) using receiver operator curves.ResultsThe study cohort included 500 patients with mean age 55 years ± 18 and peak tricuspid regurgitation velocity 2.7 ± 1.4 m/s. The area under ROC for RVS was 0.69 (95% CI 0.63–0.75) and 0.78 (95% CI 0.70–0.88) to predict RVEF < 45% & RVEF < 30%, respectively. The RV FAC% had second highest accuracy of predicting RVEF among all the TTE parameters tested in study.ConclusionRight ventricular strain is the most accurate echocardiographic method to detect impaired right ventricular systolic function when using MRI as the gold standard.
A Unique Compensatory Mechanism for Total Pulmonary Vein Occlusion Post Atrial Fibrillation Catheter Ablation Visualized by Multimodality Imaging
Pulmonary vein (PV) stenosis is a rare and serious complication of radiofrequency catheter ablation (RFCA) for atrial fibrillation. However, it can be asymptomatic or mildly symptomatic depending on the severity of the stenosis and the development of compensatory mechanisms. This study provides a detailed description and visualization of a unique type of venous collaterals that bypass the PV stenosis and drain directly in the left atrium alleviating PV stenosis sequelae. This study reports a case of a 61-year-old male who presented with mild dyspnea and fatigue 3 years post atrial fibrillation RFCA. After a thorough evaluation of the case, a redo-ablation was planned. As a part of the preablation workup, a transesophageal echocardiography (TEE), a ventilation-perfusion (V/Q) scan of the lungs, and a chest computed tomography angiogram (CTA) were performed. The TEE revealed total obstruction of the left superior PV, with no color Doppler flow detected. It also showed evidence of multiple collateral flows at the os of the left superior PV. The V/Q scan showed a large perfusion defect involving the entire left upper lobe consistent with a compromised left upper PV flow. The CTA with 3D volume rendering revealed the total occlusion of the left superior PV at its ostium. Moreover, the scan confirmed the pulmonary venous drainage via small collateral channels that was suggested by the TEE.
Comparison of Echocardiographic parameters with Cardiac Magnetic Resonance Imaging in the Assessment of Right Ventricular Function
Introduction: The right ventricle (RV) strain measured by speckle tracking (RVS) is a novel method of assessing RV function. We compared RVS to RV fractional area change (FAC%), tricuspid annular peak systolic excursion (TAPSE) and Doppler tissue imaging-derived peak systolic velocity (S’) in the assessment of right ventricular (RV) systolic function measured using cardiac magnetic resonance imaging (MRI). Methods: We enrolled consecutive patients who underwent cardiac MRI between Jan 2012- Dec 2017 and a transthoracic echocardiogram (TTE) within 1 month of the MRI with no interval event. Baseline clinical characteristics and MRI parameters were extracted from chart review. Echocardiographic parameters were measured prospectively. TTE parameters including RVS, TAPSE, S’ and FAC% were tested for accuracy to identify impaired RV EF (EF <45% & <30%) using receiver operator curves. Results: The study cohort included 500 patients with mean age 55 yr ± 18 and right ventricular systolic pressure 33.7 ± 13.6 mmHg. The area under ROC for RVS was 0.69 (95% CI 0.63 – 0.75) and 0.78 (95% CI 0.70 – 0.88) to predict RVEF <45% & RVEF <30% respectively. The RV FAC % had second highest accuracy of predicting RVEF among all the TTE parameters tested in study. Conclusion: Right ventricular strain is the most accurate echocardiographic method to detect impaired right ventricular systolic function when using MRI as the gold standard.
Does a Gradient-Adjusted Cardiac Power Index Improve Prediction of Post-Transcatheter Aortic Valve Replacement Survival Over Cardiac Power Index?
P339 Gradient adjusted cardiac power index does not improve prediction of survival post transcatheter aortic valve replacement compared to cardiac power index alone
Abstract Funding Acknowledgements None Background Cardiac Power Index (CPI) is an integrative hemodynamic measure of cardiac pumping capability and is the product of the simultaneously measured mean arterial pressure (MAP) and cardiac output (CO). In patients with aortic stenosis (AS), MAP is not reflective of mean systolic left ventricular (LV) pressure due to the transvalvular gradient. Non-invasive assessment of mean systolic LV pressure is challenging in severe aortic stenosis. CPI assessed using systemic MAP was previously shown to predict survival post transcatheter aortic valve replacement (TAVR). Purpose We evaluated the utility of a gradient adjusted CPI in predicting survival post TAVR compared to CPI alone Methods A retrospective study was performed including patients undergoing TAVR with 1 year follow-up. Baseline demographics, clinical, and echocardiographic data were abstracted from a cohort of 1,011 patients. CPI was calculated, (CO x MAP)/ (451 x BSA) Watts/m2. Gradient adjusted CPI was calculated using an augmented MAP i) adding aortic valve mean gradient(AVMG) to systolic blood pressure (CPI1); ii) adding aortic valve maximal instantaneous gradient to systolic blood pressure (CPI2) and iii) adding AVMG to MAP (CPI3). Patient survival score was calculated using a step up technique to identify the cut off value for CPI and gradient adjusted CPI to identify, where the maximum difference in mortality occurred. Multivariate cox-regression analysis was performed to adjust for baseline covariates. Receiver operator curves(ROC) for CPI and gradient adjusted CPI were calculated to predict survival post TAVR. Results The mortality rate at 1 yr was 16%. Mean age and AVMG of survivors was 81 +/- 9 yrs and 43 +/-14 mmHg vs 80 +/-9 yrs and 42 +/- 13 mmHg in the deceased group. Proportion of female patients was similar in both groups (p = 0.7). Patients in the deceased group at baseline had a higher prevalence of chronic lung disease, atrial fibrillation, heart failure within 2-weeks of procedure, higher STS-PROM score, lower serum albumin level, higher prevalence of moderate to severe tricuspid regurgitation, higher right ventricular systolic pressure and higher prevalence of dialysis. Both CPI and gradient adjusted CPI were independently associated with survival at 1 year. The area under ROC for CP, CP1, CP2 and CP3 were 0.67 (95% confidence interval [CI] 0.62 - 0.72), 0.65 (95% CI 0.60 – 0.70), 0.66 (95% CI 0.61 – 0.71) and 0.63 (95% CI 0.58 – 0.68) respectively. Conclusion Gradient adjusted CPI did not improve accuracy of predicting post TAVR survival at 1 year compared to CPI alone. Abstract P339 Figure. Area under ROC
P614Comparison of echo parameters with cardiac MRI in the assessment of right ventricular function
Abstract Introduction Systolic right ventricular (RV) function has prognostic significance both in acquired and congenital heart diseases. However accurate assessment of RV ejection fraction (EF) with transthoracic echocardiography (TTE) remains challenging due to the complex geometric shape of the RV. Magnetic resonance imaging (MRI) remains the gold standard modality for assessment of RV function; however the cost and availability limits the regular use of MRI in clinical practice. The RV strain measured by speckle tracking (RVS) is a novel method of assessing RV EF. Purpose The purpose of the study was to assess the accuracy of RVS compared RV fractional area change (FAC%), tricuspid annular peak systolic excursion (TAPSE) and Doppler tissue imaging-derived isovolumic acceleration and peak systolic velocity (S') at the lateral tricuspid annulus in the assessment of impaired RV EF. Methods We retrospectively identified patients who had a cardiac MRI between 2012- 2017 and only included patients with a TTE within 1 month of the MRI for our final analysis. Baseline characteristics, TTE and MRI parameters were extracted from chart review. RV strain was measured retrospectively using ECHOINSIGHT software. Four TTE parameters including RVS, TAPSE, S' and FAC% were tested for accuracy to identify impaired RV EF (defined as EF<45%) using receiver operator curves. Results The study cohort included 500 patients with mean age 55 yr ± 18 and right ventricular systolic pressure 33.7±13.6 mmHg. The proportion of female gender, diabetes, hypertension and obstructive sleep apnea were 38%, 15.6%, 43% & 19.8% respectively. The area under ROC for TAPSE, S', FAC% and RVS were 0.58 (95% confidence interval [CI] 0.51–0.65, p=0.03), 0.59 (95% CI 0.52–0.66, p=0.03), 0.67 (95% CI 0.61–0.73, p=0.03) and 0.70 (0.64–0.76, p=0.03) for assessing RV EF <45%. Conclusion Right ventricular strain most accurately detected impaired right ventricular ejection fraction as obtained by MRI. Acknowledgement/Funding None