AbstractBackgroundThe incidence and impact of noise in a subcutaneous implantable cardioverter defibrillator (S‐ICD) after left ventricular assist device (LVAD) implantation is not well established.MethodsWe performed a retrospective study of patients implanted with LVAD and with a pre‐existing S‐ICD between January 2005 and December 2020 at the three Mayo Clinic centers (Minnesota, Arizona, and Florida).ResultsOf the 908 LVAD patients, a pre‐existing S‐ICD was present in 9 patients (mean age 49.1 ± 13.7 years, 66.7% males), 100% with Boston Scientific third‐generation EMBLEM MRI S‐ICD, 11% with HeartMate II (HM II), 44% with HeartMate 3 (HM 3), and 44% with HeartWare (HW) LVAD. The incidence of noise from LVAD‐related electromagnetic interference (EMI) was 33% and was only seen with HM 3 LVAD. Multiple measures attempted to resolve noise, including using alternative S‐ICD sensing vector, adjusting S‐ICD time zone, and increasing LVAD pump speed, were unsuccessful, necessitating S‐ICD device therapies to be turned off permanently.ConclusionsThe incidence of LVAD‐related S‐ICD noise is high in patients with concomitant LVAD and S‐ICD with significant impact on device function. As conservative management failed to resolve the EMI, the S‐ICDs had to be programmed off to avoid inappropriate shocks. This study highlights the importance of awareness of LVAD‐SICD device interference and the need to improve S‐ICD detection algorithms to eliminate noise.
Reclassification of Treatment Strategy with Fractional Flow Reserve in Cancer Patients with Coronary Artery Disease
Background and Objectives: Cancer and coronary artery disease (CAD) often coexist. Compared to quantitative coronary angiography (QCA), fractional flow reserve (FFR) has emerged as a more reliable method of identifying significant coronary stenoses. We aimed to assess the specific management, safety and outcomes of FFR-guided percutaneous coronary intervention (PCI) in cancer patients with stable CAD. Materials and Methods: FFR was used to assess cancer patients that underwent coronary angiography for stable CAD between September 2008 and May 2016, and were found to have ≥50% stenosis by QCA. Patients with lesions with an FFR > 0.75 received medical therapy alone, while those with FFR ≤ 0.75 were revascularized. Procedure-related complications, all-cause mortality, nonfatal myocardial infarction, or urgent revascularizations were analyzed. Results: Fifty-seven patients with stable CAD underwent FFR on 57 lesions. Out of 31 patients with ≥70% stenosis as measured by QCA, 14 (45.1%) had an FFR ≥ 0.75 and lesions were reclassified as moderate and did not receive PCI nor DAPT. Out of 26 patients with <70% stenosis as measured by QCA, 6 (23%) had an FFR < 0.75 and were reclassified as severe and were treated with PCI and associated DAPT. No periprocedural complications, urgent revascularization, acute coronary syndromes, or cardiovascular deaths were noted. There was a 22.8% mortality at 1 year, all cancer related. Patients who received a stent by FFR assessment showed a significant association with decreased risk of all-cause death (HR: 0.37, 95% CI 0.15–0.90, p = 0.03). Conclusions: Further studies are needed to define the optimal therapeutic approach for cancer patients with CAD. Using an FFR cut-off point of 0.75 to guide PCI translates into fewer interventions and can facilitate cancer care. There was an overall reduction in mortality in patients that received a stent, suggesting increased resilience to cancer therapy and progression.
Abstract 9796: Atypical Right Atrial Flutter with Double Loop Reentry Involving the Cavotricuspid Isthmus and Superior Vena Cava with Successful Ablation
Introduction: Atrial flutter (AFL) with figure-of-eight reentry (FOER) is effectively terminated by catheter ablation (CA) of the shared isthmus. Case: A 50-year-old man with prior mitral valve (MV) repair presented to our hospital with palpitations for 9 months refractory to metoprolol. ECG showed coarse atrial fibrillation at 61 bpm. Echocardiography showed left ventricular LVEF of 45%. Electrophysiology study revealed AFL (cycle length, TCL 290 msec) with a concentric activation pattern on the coronary sinus (CS) catheter, and a chevron pattern on the Halo catheter placed against the lateral tricuspid annulus (TA). Entrainment map revealed a near equal post-pacing interval and TCL in proximal CS, low lateral right atrium (RA), and CTI. Incomplete line of block was noted in the anterior wall of RA near the superior vena cava (SVC), likely from prior atriotomy scar. Double loop reentry (DLR) was demonstrated with one wavefront (WV) traveling counterclockwise around the TA using the CTI, and the other WV traveling posteriorly around the SVC (Figure). After CTI ablation, TCL changed from 290 msec to 330 msec suggesting blocked CTI. Now, the WV was a single loop around the SVC, confirmed by repeat activation mapping. Linear ablation from anterior TA to the anterior aspect of the SVC terminated the AFL. Differential pacing from either side of the anterior line and the CTI demonstrated a conduction time of > 200 msec and 150 msec in either direction, respectively. Decremental atrial pacing was unable to induce any arrhythmias. Discussion: FOER in this case is suggested by fusion of WVs in the lateral RA. The 2 circuits each had their own conduction gap, in the CTI and anterior RA wall near the SVC, respectively. DLR was proven by entrainment as well as activation mapping. The faster CTI-dependent AFL was entraining the upper loop reentry circuit. Conclusion: Atypical right AFL with DLR mimicking FOER was successfully terminated by CA of CTI and anterior line of ablation from TA to SVC.
Electromagnetic interference from left ventricular assist device in patients with transvenous implantable cardioverter‐defibrillator
AbstractBackgroundMany advanced heart failure patients have both a left ventricular assist device (LVAD) and an implantable cardioverter‐defibrillator (ICD). This study examines incidence, clinical impact, and management of LVAD‐related EMI.MethodsWe performed a three‐center retrospective analysis of transvenous ICD implanted patients with LVAD implanted between January 1, 2005 and December 31, 2020. The primary outcome was EMI after LVAD implantation, categorized as LVAD‐related noise or telemetry interference.ResultsThe rate of LVAD‐related EMI among the 737 patients (mean age 58.6 ± 12.8 years) studied was 5.0%. Telemetry interference (1.5%) compromised ICD interrogation in all patients. This was resolved successfully with use of a metal shield, encased wand, radiofrequency tower, different ICD programmer or by increasing distance between ICD programmer and LVAD (n = 6). ICD replacement was required to reestablish successful communication in three patients. LVAD‐related noise (3.5%) led to oversensing (n = 4), inappropriate mode switches (n = 4), noise reversion (n = 3), inhibition of pacing (n = 2), inappropriate detection as atrial fibrillation (AF) (n = 2) and inappropriate detection as ventricular tachycardia (VT) and/or ventricular fibrillation (VF) (n = 2). This noise interference persisted (n = 3), resolved spontaneously (n = 16), resolved with programming change (n = 6) or required lead revision (n = 1).ConclusionsEMI from LVAD impacts ICD function, although, the incidence rate is low. Physicians implanting both, LVAD in patients with ICD (more common) or ICD in patients with LVAD, should be aware of possible interferences. Telemetry failure not resolved by metal shielding was overcome by ICD generator replacement to a different manufacturer. In most cases, LVAD‐related noise resolves spontaneously.