Back to Authors

Lee, Yong S.

https://orcid.org/0009-0005-9707-144X

Mayo Clinic

Mayo Clinic

Citations 17

A Pilot Study to Estimate the Impact of High Matrix Image Reconstruction on Chest Computed Tomography
Johnson, Tucker F. , Voß, Benjamin, Lee, Yong S. , Koo, Chi Wan , McCollough, Brian, Weaver, Jayse , Gong, Hao , Carter, Rickey E. , Inoue, Akitoshi , Voss, Benjamin A, McCollough, Brian D, Weaver, Jayse M, Carter, Rickey E , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Journal of Clinical Imaging Science | September 30, 2021 | Volume: 11 | Issue: No issue available | Pages: 52

10.25259/jcis_143_2021 Get It

Objectives: The objectives of the study were to estimate the impact of high matrix image reconstruction on chest computed tomography (CT) compared to standard image reconstruction. Material and Methods: This retrospective study included patients with interstitial or parenchymal lung disease, airway disease, and pulmonary nodules who underwent chest CT. Chest CT images were reconstructed using high matrix (1024 × 1024) or standard matrix (512 × 512), with all other parameters matched. Two radiologists, blinded to reconstruction technique, independently examined each lung, viewing image sets side by side and rating the conspicuity of imaging findings using a 5-point relative conspicuity scale. The presence of pulmonary nodules and confidence in classification of internal attenuation was also graded. Overall image quality and subjective noise/artifacts were assessed. Results: Thirty-four patients with 68 lungs were evaluated. Relative conspicuity scores were significantly higher using high matrix image reconstruction for all imaging findings indicative of idiopathic lung fibrosis (peripheral airway visualization, interlobular septal thickening, intralobular reticular opacity, and end-stage fibrotic change; P ≤ 0.001) along with emphysema, mosaic attenuation, and fourth order bronchi for both readers (P ≤ 0.001). High matrix reconstruction did not improve confidence in the presence or classification of internal nodule attenuation for either reader. Overall image quality was increased but not subjective noise/artifacts with high matrix image reconstruction for both readers (P < 0.001). Conclusion: High matrix image reconstruction significantly improves the conspicuity of imaging findings reflecting interstitial lung disease and may be useful for diagnosis or treatment response assessment.
The utility of a dual-phase, dual-energy CT protocol in patients presenting with overt gastrointestinal bleeding
Mohammadinejad, Payam , Kwapisz, Lukasz , Fidler, Jeff L. , Sheedy, Shannon P. , Heiken, Jay P. , Wells, Michael , Froemming, Adam T. , Hansel, Stephanie L. , Lee, Yong S. , Halaweish, Ahmed F., Bruining, David H. , Wells, Michael L, Hansel, Stephanie L , Inoue, Akitoshi , Fletcher, Joel G , Mohammadinejad, Payam, Fidler, Jeff L. , Khandelwal, Ashish , McCollough, Cynthia H. , Fletcher, Joel G.

Acta Radiologica Open | July 27, 2021 | Volume: 10 | Issue: 7 | Pages: No page available

10.1177/20584601211030658 Get It

Background Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. Purpose To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. Materials and Methods Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). Results 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images ( p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images ( p = 0.006, p = 0.018). Conclusion A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.
The feasibility of low iodine dynamic CT angiography with test bolus for evaluation of lower extremity peripheral artery disease
Inoue, Akitoshi , Vrtiska, Terri J., Lee, Yong S. , Vasconcelos, Rogerio N., Weber, Nikkole M. , Halaweish, Ahmed F., Duba, Irene , Williamson, Eric E. , Fletcher, Joel G , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Vascular | January 18, 2021 | Volume: 29 | Issue: 6 | Pages: 927-937

10.1177/1708538120986304 Get It

Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.
Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique
Iyer, Veena R. , Ehman, Eric C. , Khandelwal, Ashish , Wells, Michael , Lee, Yong S. , Weber, Nikkole M. , Johnson, Matthew P. , Yu, Lifeng , Fletcher, Joel G. , Wells, Michael L, Fletcher, Joel G , Yu, Lifeng , McCollough, Cynthia H.

Acta Radiologica | January 27, 2020 | Volume: 61 | Issue: 9 | Pages: 1186-1195

10.1177/0284185119898655 Get It

Background Low tube potential-high tube current computed tomography (CT) imaging allows reduction in iodine-based contrast dose and may extend the benefit of routine contrast-enhanced CT exams to patients at risk of nephrotoxicity. Purpose To determine the ability of an iodine contrast reduction algorithm to maintain diagnostic image quality for contrast-enhanced abdominal CT. Material and Methods CT exams with iodine contrast reduction were prescribed for patients at risk for renal dysfunction. The iodine contrast reduction algorithm combines weight-based contrast volume reduction with patient width-based low tube potential selection and bolus-tracking. Control exams with routine iodine dose were selected based on weight, width, and scan protocol. Three radiologists evaluated image quality and diagnostic confidence using a 4-point scale (<2 acceptable). Another radiologist assessed contrast reduction indications and measured portal vein and liver contrast-to-noise ratios. Results Forty-six contrast reduction algorithm and control exams were compared (mean creatinine 1.6 vs. 1.2 mg/dL, P ≤ 0.0001). Thirty-nine contrast reduction patients had an eGFR <60 mL/min/1.73m 2 and 15 had single or transplanted kidney. Mean iodine contrast dose was lower in the contrast reduction group (20.9 vs. 39.4 g/mL, P < 0.0001). Diagnostic confidence was rated as acceptable in 95% (131/138) of contrast reduction and 100% of control exams (1.18–1.28 vs. 1.02–1.13, respectively; P > 0.06). Liver attenuation and contrast-to-noise ratio (CNR) were similar ( P = 0.08), but portal vein attenuation and CNR were lower with contrast-reduction (mean 176 vs. 198 HU, P = 0.02; 13 vs. 16, P = 0.0002). Conclusion This size-based contrast reduction algorithm using low kV and bolus tracking reduced iodine contrast dose by 50%, while achieving acceptable image quality in 95% of exams.
Imaging Findings of Ileal Inflammation at Computed Tomography and Magnetic Resonance Enterography: What do They Mean When Ileoscopy and Biopsy are Negative?
Nehra, Avinash , Sheedy, Shannon P. , Wells, Michael , VanBuren, Wendaline M. , Deepak, Parakkal , Lee, Yong S. , Bruining, David H. , Fletcher, Joel G. , Nehra, Avinash K, Wells, Michael L, Hansel, Stephanie L. , Fletcher, Joel G , Deepak, Parakkal

Journal of Crohn's and Colitis | October 25, 2019 | Volume: 14 | Issue: 4 | Pages: 455-464

10.1093/ecco-jcc/jjz122 Get It

Abstract Background and Aims Our goal was to determine the importance of ileal inflammation at computed tomography or magnetic resonance enterography in Crohn’s disease patients with normal ileoscopy. Methods Patients with negative ileoscopy and biopsy within 30 days of CT or MR enterography showing ileal inflammation were included. The severity [0–3 scale] and length of inflammation within the distal 20 cm of the terminal ileum were assessed on enterography. Subsequent medical records were reviewed for ensuing surgery, ulceration at ileoscopy, histological inflammation, or new or worsening ileal inflammation or stricture on enterography. Imaging findings were classified as: Confirmed Progression [subsequent surgery or radiological worsening, new ulcers at ileoscopy or positive histology]; Radiologic Response [decreased inflammation with medical therapy]; or Unlikely/Unconfirmed Inflammation. Results Of 1471 patients undergoing enterography and ileoscopy, 112 [8%] had imaging findings of inflammation with negative ileoscopy, and 88 [6%] had negative ileoscopy and ileal biopsy. Half [50%; 44/88] with negative biopsy had moderate/severe inflammation at enterography, with 45%, 32% and 11% having proximal small bowel inflammation, stricture or fistulas, respectively. Two-thirds with negative biopsy [67%; 59/88] had Confirmed Progression, with 68%, 70% and 61% having subsequent surgical resection, radiological worsening or ulcers at subsequent ileoscopy, respectively. Mean length and severity of ileal inflammation in these patients was 10 cm and 1.6. Thirteen [15%] patients had Radiologic Response, and 16 [18%] had Unlikely/Unconfirmed Inflammation. Conclusion Crohn’s disease patients with unequivocal imaging findings of ileal inflammation at enterography despite negative ileoscopy and biopsy are likely to have active inflammatory Crohn’s disease. Disease detected by imaging may worsen over time or respond to medical therapy.
Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose
Gutjahr, Ralf , Lee, Yong S. , Halaweish, Ahmed F., Suresh, Vighnesh , Weber, Nikkole M. , Vrtiska, Terri J., Williamson, Eric E. , Schmidt, Bernhard , Fletcher, Joel G. , McCollough, Cynthia H.

Journal of Computer Assisted Tomography | July 3, 2019 | Volume: 43 | Issue: 4 | Pages: 612-618

10.1097/rct.0000000000000874 Get It

Objective The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. Methods The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. Results The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. Conclusion The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.
Findings of CT-Derived Bone Strength Assessment in Inflammatory Bowel Disease Patients Undergoing CT Enterography in Clinical Practice
Maldonado, Francisco J., Al‐Bawardy, Badr , Nehra, Avinash , Lee, Yong S. , Bruining, David H. , Adkins, Mark C., Keaveny, Tony M. , Johnson, Matthew P. , Fidler, Jeff L. , Al Bawardy, Badr F, Nehra, Avinash K, Maldonado, Francisco J, Fidler, Jeff L. , McCollough, Cynthia H. , Fletcher, Joel G.

Inflammatory Bowel Diseases | November 26, 2018 | Volume: 25 | Issue: 6 | Pages: 1072-1079

10.1093/ibd/izy341 Get It