Ventricular Fibrillation Mapping in a Large-Animal Model Using Dual Mechanical Circulatory Support: Electroanatomic Substrate Preservation Without Ischemic Changes
Circulation: Arrhythmia and Electrophysiology | September 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
BACKGROUND: Ventricular fibrillation (VF) remains a leading cause of sudden cardiac death with an incompletely characterized electrophysiological substrate. Traditional large-animal VF models are limited by hemodynamic collapse and myocardial ischemia. This study establishes a reproducible swine model using dual mechanical circulatory devices to enable high-density electroanatomic mapping under nonischemic conditions. METHODS: Five Yorkshire swine (55–65 kg) underwent sustained VF supported by venoarterial extracorporeal membrane oxygenation (2.5–3.0 L/min) and percutaneous left ventricular unloading (Impella CP, P-2–P-4). High-density electroanatomic mapping using CARTO 7 was performed at baseline and after defibrillation. Bipolar voltage was acquired from 7 predefined ventricular regions (21 measurements per animal per time point; n=210 paired observations). Unipolar voltage mapping and continuous surface ECG monitoring were used to assess acute ischemic injury. Systemic perfusion was maintained at systolic arterial pressure ≥80 mm Hg. Linear mixed-effects modeling was used to analyze voltage changes from pre-VF to post-VF. RESULTS: Sustained VF (10±1 minutes) was reproducibly induced and maintained with consistent hemodynamics (systolic arterial pressure, 90±5 mm Hg; extracorporeal membrane oxygenation flow, 2.5±0.5 L/min). All animals were successfully defibrillated. High-density mapping was feasible in all experiments (1000±300 points per chamber). Bipolar voltage showed no change from pre-VF (5.86±2.56 mV) to post-VF (6.53±2.22 mV; mean difference, 0.67 mV [95% CI, –0.31 to 1.65]; P =0.15). Both left ( P =0.17) and right ventricles ( P =0.08) demonstrated voltage preservation. Regional analysis showed no significant changes (all P >0.05); post-VF voltages remained above viability thresholds (>1.5 mV). Unipolar voltage maps recovered toward baseline, with no ECG injury pattern identified after defibrillation. CONCLUSIONS: Dual mechanical circulatory support with venoarterial extracorporeal membrane oxygenation and Impella CP enables reproducible, high-fidelity electroanatomic mapping and preserves myocardial substrate after sustained VF in a large-animal model. This platform overcomes key technical barriers in VF research, providing a nonischemic foundation for future mechanistic and translational studies.
Physiology-guided cardioneuroablation for vagally mediated syncope and functional bradyarrhythmias
Abstract Background Vagally mediated syncope and functional bradyarrhythmias can cause recurrent symptoms, injury and a need for permanent pacing, yet standard therapies do not address the underlying autonomic reflex. Cardioneuroablation (CNA) targets this mechanism, but adoption has been limited by uncertainty about patient selection, procedural endpoints and durable outcomes. Methods We studied 95 consecutive patients with vagally mediated syncope (n=78) or functional bradyarrhythmia (n=17) who underwent CNA at a single center by a single lead operator under a uniform, prospectively maintained protocol. Extracardiac vagal stimulation (ECVS) was performed before and after ablation to confirm vagally mediated sinus or atrioventricular (AV) nodal responses and to verify their attenuation. Outcomes through 1 year included clinical recurrence, quality of life, pacing burden and pacemaker extraction. Results Before ablation, ECVS provoked sinus pauses in 95.8% of patients and AV block in 91.6%; after ablation, sinus pauses were abolished in every patient and residual AV block was present in 4.2%. One-year freedom from recurrent syncope and from bradyarrhythmia-related events was 93.8% and 94.1%. Syncope burden fell from a median of 2.7 episodes per year to none, and disease-specific quality of life improved substantially (P<0.001). Among patients with pre-existing devices, atrial pacing burden fell from a median of 22% to 0%. There were no strokes, deaths or myocardial infarctions. Conclusions In this single-center cohort, physiology-guided CNA was associated with durable symptom control, improved quality of life and reduced pacing across vagally mediated bradyarrhythmia syndromes. Multicenter controlled studies are needed to confirm these findings.
Long‐Term Outcomes of Leadless Pacemaker vs. Transvenous Pacemaker in End‐Stage Renal Disease
ABSTRACT Background Patients with end‐stage renal disease (ESRD) undergoing dialysis have an increased risk of pacemaker‐related complications due to limited vascular access and increased susceptibility to infection. Leadless pacemakers (LPMs) may mitigate these risks compared with conventional transvenous pacemakers (TPMs), but long‐term comparative data in this population remain limited. Methods We conducted a retrospective cohort study using the TriNetX Research Network, including adults (≥ 18 years) with ESRD on dialysis who underwent LPM or TPM implantation between May 2016 and December 2020. Propensity score matching (1:1) was performed using demographics and comorbidities. Outcomes assessed over up to 5 years included all‐cause hospitalization, heart failure hospitalization, device re‐intervention, device‐related complications, infection‐related hospitalization, pacemaker‐induced cardiomyopathy, and all‐cause mortality. Results After matching, 901 patients were included in each group with well‐balanced baseline characteristics. LPM implantation was associated with a significantly lower risk of device re‐intervention compared with TPM (4.1% vs. 9.3%; hazard ratio [HR] 0.44; 95% confidence interval [CI] 0.28–0.69; p < 0.01). There were no significant differences between groups in all‐cause hospitalization (65.5% vs. 68.3%; p = 0.22), heart failure hospitalization (26.9% vs. 30.2%; p = 0.13), all‐cause mortality (37.5% vs. 35.3%; p = 0.34), device‐related complications (14.5% vs. 14.3%; p = 0.94), infection‐related hospitalization (1.6% vs. 2.1%; p = 0.35), or pacemaker‐induced cardiomyopathy (9.0% vs. 8.6%; p = 0.66). Conclusion In a large, propensity‐matched cohort of patients with ESRD on dialysis, LPMs were associated with fewer device re‐interventions and comparable long‐term clinical outcomes compared with TPMs.
Clinical Outcomes of Catheter Ablation for Atrial Fibrillation in Patients With Hypertrophic Cardiomyopathy
ABSTRACT Background Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and is associated with increased morbidity, heart failure (HF) exacerbations, and adverse long‐term outcomes. Although catheter ablation is an established rhythm‐control strategy, data comparing its long‐term clinical outcomes with anti‐arrhythmic drug (AAD) therapy in patients with HCM remain limited. Objective To compare long‐term clinical outcomes of catheter ablation versus medical therapy with AADs in patients with HCM and AF. Methods We conducted a retrospective cohort study using the TriNetX Research Network, a global federated database of electronic health records. Adult patients with HCM and AF between January 2010 and December 2020 were identified and stratified according to treatment with catheter ablation or AAD therapy. Outcomes included all‐cause mortality, HF exacerbations, AAD‐related adverse events, all‐cause hospitalization, ischemic stroke, repeat ablation, need for cardioversion, need for long‐term AAD use, and atrioventricular nodal ablation. A 1:1 propensity score matching (PSM) analysis was performed to balance baseline characteristics. Kaplan–Meier survival analysis and Cox proportional hazards models were used to estimate hazard ratios (HRs). Results After PSM, 3144 patients were included (1572 in each cohort) with a mean follow‐up of approximately 3.4 years. Catheter ablation was associated with lower all‐cause mortality compared with AAD therapy (9.5% vs. 14.8%; HR: 0.60; 95% CI: 0.49–0.74; p < 0.001). Ablation was also associated with reduced risk of HF exacerbations (38.4% vs. 43.3%; HR: 0.79; 95% CI: 0.71–0.88; p < 0.001) and fewer AAD‐related adverse events (8.4% vs. 11.2%; HR: 0.71; 95% CI: 0.55–0.93; p = 0.011). Rates of all‐cause hospitalization (HR: 0.93; p = 0.11) and ischemic stroke (HR: 0.78; p = 0.10) were similar between groups. Conclusion In this large real‐world cohort of patients with HCM and AF, catheter ablation was associated with lower mortality, reduced HF hospitalizations, and decreased AAD therapy‐related adverse events, as compared with medical therapy. These findings suggest that catheter ablation may provide meaningful clinical benefits in selected patients with HCM and AF, although prospective studies are needed to confirm these observations.
Incidence and type of recurrent ventricular arrhythmia in patients with arrhythmic mitral valve prolapse and implantable cardioverter defibrillator for secondary prevention
Abstract Aims Mitral valve prolapse (MVP) is a common valvular disorder associated with ventricular arrhythmias (VAs) in a subgroup of patients, known as arrhythmic MVP (AMVP). Arrhythmic MVP patients with malignant VAs typically receive an implantable cardioverter-defibrillator (ICD) for secondary prevention. However, data regarding the incidence of appropriate ICD therapy and the type of arrhythmia recurrence in this population remain scarce. This study aimed to evaluate the incidence of appropriate ICD therapies and type of arrhythmia recurrence in AMVP patients with an ICD implanted for secondary prevention. Methods and results A systematic literature search was conducted in PubMed/MEDLINE and EMBASE databases until January 2025. Studies reporting the incidence of appropriate ICD therapy in AMVP patients were included. A total of 9 studies met the inclusion criteria, resulting in 166 AMVP patients with ICDs for secondary prevention. The mean age was 41.8 years, with 55.8% of patients being female. Over a weighted mean follow-up of 4.9 ± 3.1 years, 34.9% [95% confidence interval (CI): 28.1–42.5] of the patients experienced recurrence of VA. The pooled incidence of appropriate ICD therapies during follow-up was 8.1 per 100 person-years (95% CI: 5.6–10.5, I2: 11.7%). Regarding the type of arrhythmic recurrence, the majority of arrhythmias (53.8%, 95% CI: 44.3–63.0%) were in the form of ventricular fibrillation or polymorphic ventricular tachycardia (VT), while the remaining arrhythmias were reported as monomorphic VT. Among 67 ventricular arrhythmic episodes reported in 7 studies with available data, 65 required shock therapy, corresponding to a shock proportion of 97.0% (95% CI: 89.6–99.6%). Conclusion Arrhythmic MVP patients with ICDs for secondary prevention exhibit a high risk of recurrent arrhythmias, with recurrences in the form of polymorphic VA occurring in more than half of the cases. PROSPERO registration number: CRD42024588610
First-in-Human Clinical Experience With Focal Pulsed Field and Radiofrequency Dual-Modality Ablation for Treatment Refractory Left Ventricular Summit PVCs
BACKGROUND: Radiofrequency (RF) ablation of premature ventricular complexes (PVCs) originating from the left ventricular summit may be unsuccessful, highlighting the need for alternative approaches. We aimed to assess the efficacy and safety of a novel dual-modality focal catheter in treating left ventricular summit PVCs in patients who had failed previous RF ablation. METHODS: Patients were prospectively enrolled and underwent a redo ablation procedure using an irrigated, contact-force sensing, dual-modality focal catheter (TactiFlex Duo, Abbott) under compassionate use indication. The ablation strategy, including the choice of energy modality (monopolar pulsed field [PF], RF, or both), was left to the operator’s discretion. Safety assessments included serial biomarkers, renal function, and CMR within 36 hours. Efficacy was defined as ≥80% reduction in PVC burden with symptom resolution at 3-month follow-up. RESULTS: Six consecutive patients (4 men; mean age, 53.8±15 years) with symptomatic left ventricular summit PVCs and a prior failed RF ablation (range, 1–2) were prospectively enrolled. All PVCs had an inferior axis, with a left bundle V1 morphology observed in 4 of 6 cases (mean burden, 30.1±5.3%). Acute suppression of PVCs was achieved in all cases. Acute suppression with a single PF application in the great cardiac vein-anterior interventricular vein occurred in 2 patients, while 3 patients required additional RF, PF, or combined RF+PF applications at adjacent sites. One patient with an inaccessible great cardiac vein-anterior interventricular vein was successfully treated in the left ventricular outflow tract with RF+PF application. Transient, reversible left anterior descending vasospasm was observed during PF delivery in 2 of 5 cases that underwent PF application adjacent to a coronary artery, despite pretreatment with intracoronary nitroglycerin without ECG or hemodynamic sequelae. All patients had durable suppression of PVCs at follow-up. CONCLUSIONS: In its first human application, dual-modality ablation was feasible and effective for refractory left ventricular summit PVCs. Transient coronary vasospasm occurred, though it was reversible and without acute clinical consequences.
Stroke and systemic embolism following atrial fibrillation ablation: the EMBOL-AF Global Registry
Abstract Background and Aims Stroke and systemic embolism are recognized but poorly characterized complications of atrial fibrillation (AF) and left atrial flutter (AFL) catheter ablation. Their incidence, outcomes, and procedural associations remain insufficiently defined. Methods Retrospective global registry was initiated by the European Heart Rhythm Association Scientific Committee. A secure database captured data from ablation centres worldwide on general AF and left AFL ablation activity, as well as detailed information on patients with symptomatic embolic events between 2017 and 2024. Results Overall, 204 centres reported 335 743 ablation procedures and 550 embolic events (incidence 0.16%). Centre-level rate ranged from 0% to 3.1%. Most events were cerebral (94%), followed by peripheral (5%), and combined (1%). Coronary air embolism accounted for 62% of all peripheral events. Intraprocedural events occurred in 93 patients (17%), within 72 h in 357 (78%) and beyond 72 h in 100 (22%); 128 cases (23%) were diagnosed after hospital discharge. Nonparoxysmal AF (0.23% vs 0.15%; P < .001), centre experience, and ablation energy source (radiofrequency, 0.16%; cryoballoon, 0.16%; pulsed field ablation, 0.25%; laserballoon, 0.88%; P < .001) were associated with embolic risk. Median NIHSS score after stroke was 4 (interquartile range, 2–9). Three-month follow-up was available for 518 patients with embolism (95%): 181 (35%) had sequelae and 16 (3%) died. Conclusions Symptomatic embolic events are infrequent but associated with significant morbidity and mortality. Most events occur early, though a substantial proportion arise later. Higher event rates were observed with laser and possibly with pulsed field ablation. A greater centre experience was associated with a lower embolism incidence.
Atrial fibrillation and flutter conversion with pulsed electric field delivery: preclinical proof of concept
Abstract Background Many patients with atrial fibrillation (AF) suffer life-limiting symptoms and heart failure. Although enormous advances in rhythm control have been made, device-based therapies for treating recurrent episodes are limited. Using pulsed electric fields (PEF) to induce reversible electroporation of cardiac tissue may effectively terminate AF. Purpose To assess the feasibility of PEF delivery for converting atrial arrhythmias via reversible electroporation. Methods Four swine models were used in this acute study. Custom-made decapolar catheters for PEF delivery were deployed with the following configurations: 1. Endocardial right atrium (RA) and coronary sinus (CS), n=2; 2. Endocardial RA and epicardial left atrium (epiLA), n=2. AF and atrial flutter (AFL) were induced with programmed stimulation. PEF delivery was performed using the BTX 830 generator. For each attempt, a single monophasic pulse at 10 or 20µs pulse width was administered, with voltage varied across attempts (range 750-3000V). Successful (type 1 and 2 breaks) and unsuccessful conversion attempts were recorded. Post-PEF signal changes and arrhythmias were identified. Results A total of 58 AF/AFL (28 and 30 respectively) episodes were induced. Of the 37 successful conversion attempts, 33 (89.1%) were type 1 breaks. Conversion success probabilities generally increased with higher voltages for both configurations. >70% conversion success was seen with ≥1500V for the RA/CS configuration and ≥2000V for the RA/epiLA configuration. Arrhythmias including intra-atrial delay and high-grade atrioventricular block were seen, usually following successive PEF deliveries. Significant muscle stimulation was provoked with the current experimental setup. Conclusion Termination of atrial arrhythmias with PEF delivery is feasible, although further work is required to optimize its efficacy and safety.
Ventricular pulsed field defibrillation: preclinical feasibility study
Abstract Background Ventricular fibrillation (VF) is a leading cause of sudden cardiac death worldwide. Defibrillation via direct current shocks is effective but associated with significant pain and morbidity, prompting the need for alternative approaches. Reversible electroporation of cardiac tissue with pulsed electric fields (PEF) may be an effective means of terminating VF. Purpose To assess the feasibility of PEF delivery for terminating VF. Methods 5 acute swine models were used. Mechanical circulatory support with peripheral veno-arterial extracorporeal membrane oxygenation +/- percutaneous left ventricular assist device (Impella 5.5 L) was implemented and titrated to a mean arterial pressure ≥65 mmHg. Decapolar catheters were introduced into the endocardial right and/or left ventricle as well as epicardium. VF was induced with R on T shocks or rapid ventricular pacing. PEF was delivered with the endocardial catheter as the cathode and epicardial catheter as the anode; monophasic pulses (5-10) at 3000V, 100µs, and 200ms inter-pulse intervals were used. If VF persisted post-PEF, catheters were repositioned into regions of intact voltages for repeat delivery. Results 10 VF episodes were induced, 7 of which were successfully terminated with PEF delivery (70.0%). The median number of attempts to achieve VF termination was 2 (range 1-5). The post-VF rhythm was complete heart block with ventricular asystole in all successful defibrillation attempts, with no recovery after 30 minutes of observation. Significant muscle stimulation was seen with the utilized PEF parameters and catheter configurations. Conclusion Termination of VF using PEF – pulsed field defibrillation – is possible. However, further study is required to optimize delivery parameters/configurations to improve effectiveness and avoid muscle stimulation as well as conduction abnormalities.
Outcomes of Transvenous Lead Removal in Patients With Prior Mediastinal Radiation
ABSTRACT Background Transvenous lead removal (TLR) in patients with a history of mediastinal radiation poses unique challenges due to potential radiation‐induced fibrosis, vascular changes, and anatomical distortion, which may increase procedural complexity and complication risk. However, contemporary data on clinical outcomes in this population remain limited. Methods We analyzed the National Readmissions Database (2016–2021) to identify adults (≥ 18 years) undergoing TLR. Patients were stratified by prior mediastinal radiation. Baseline characteristics were compared using standard statistical tests. Multivariable logistic regression was used to evaluate the association between prior mediastinal radiation and in‐hospital outcomes, 30‐day mortality, and 30‐day readmissions after adjustment for demographics and comorbidities. Results A total of 48,985 patients underwent TLR, of whom 735 (1.5%) had a history of mediastinal radiation. Compared with patients without radiation, those with prior radiation were older (70.1 vs. 66.2 years, p < 0.01), were more frequently females (38.2% vs. 31.6%, p < 0.01), and had higher rates of valvular heart disease, atrial fibrillation, and peripheral vascular disease. Adjusted analyses demonstrated no increased risk of in‐hospital mortality (2.3% vs. 3.4%; adjusted odds ratio [aOR] 0.65, 95% confidence interval [CI] 0.41–1.18, p = 0.29) or major complications, including cardiac arrest, pericardial complications, vascular injury, pulmonary complications, or embolic events. Similarly, (3.6% vs. 5.3%; aOR 0.76, 95% CI 0.48–1.43, p = 0.35) and 30‐day all‐cause readmissions (8.7% vs. 9.1%; aOR 0.81, 95% CI 0.64–1.28, p = 0.70) were not significantly different between groups. Subgroup analyses by indication for TLR (infection vs. mechanical complication) revealed no differences in outcomes. Conclusion Despite theoretical concerns, prior mediastinal radiation was not associated with excess procedural risk or worse short‐term outcomes after TLR. These findings may inform procedural planning and risk counseling in clinical practice.