Back to Authors

Vandenberk, Bert

0000-0001-8296-920X

Mayo Clinic

Universitair Ziekenhuis Leuven

Citations 6

Incidence and type of recurrent ventricular arrhythmia in patients with arrhythmic mitral valve prolapse and implantable cardioverter defibrillator for secondary prevention
Kneizeh, Kinan , Sacher, F, Notaristefano, Francesco , Vlachos, Konstantinos , Ditac, Geoffroy , Duchâteau, Josselin , Munoz, Freddy Del‐Carpio , Jaworski, K, Alqarawi, Wael, Vandenberk, Bert , Verheul, Lisa M , Hassnik, Rutger J , Deville, Lucas, Yvorel, Cédric , Boukhris, Marouane , Pierrard, Romain, Ploux, Sylvain , Witte, K K, Costa, A Da, Bénali, Karim , Sacher, Frederic , Del-Carpio Munoz, Freddy , Jaworski, Krysztof , Figliozzi, Stefano , Verheul, Lisa M , Hassnik, Rutger J , Deville, Lucas , Yvorel, Cedric , Boukhris, Marouane , Pierrard, Romain , Ploux, Sylvain , Jaïs, Pierre , Hocini, Mélèze , Frontera, Antonio , Witte, Klaus K , Pürerfellner, Helmut , Haissaguerre, Michel , Da Costa, Antoine , Benali, Karim , Kneizeh, Kinan , Sacher, Frédéric , Duchâteau, Josselin , Alqarawi, Wael , Vandenberk, Bert , Jaı̈s, Pierre

Europace | May 3, 2026 | Volume: 28 | Issue: 6 | Pages: No page available

10.1093/europace/euag101 Get It

Abstract Aims Mitral valve prolapse (MVP) is a common valvular disorder associated with ventricular arrhythmias (VAs) in a subgroup of patients, known as arrhythmic MVP (AMVP). Arrhythmic MVP patients with malignant VAs typically receive an implantable cardioverter-defibrillator (ICD) for secondary prevention. However, data regarding the incidence of appropriate ICD therapy and the type of arrhythmia recurrence in this population remain scarce. This study aimed to evaluate the incidence of appropriate ICD therapies and type of arrhythmia recurrence in AMVP patients with an ICD implanted for secondary prevention. Methods and results A systematic literature search was conducted in PubMed/MEDLINE and EMBASE databases until January 2025. Studies reporting the incidence of appropriate ICD therapy in AMVP patients were included. A total of 9 studies met the inclusion criteria, resulting in 166 AMVP patients with ICDs for secondary prevention. The mean age was 41.8 years, with 55.8% of patients being female. Over a weighted mean follow-up of 4.9 ± 3.1 years, 34.9% [95% confidence interval (CI): 28.1–42.5] of the patients experienced recurrence of VA. The pooled incidence of appropriate ICD therapies during follow-up was 8.1 per 100 person-years (95% CI: 5.6–10.5, I2: 11.7%). Regarding the type of arrhythmic recurrence, the majority of arrhythmias (53.8%, 95% CI: 44.3–63.0%) were in the form of ventricular fibrillation or polymorphic ventricular tachycardia (VT), while the remaining arrhythmias were reported as monomorphic VT. Among 67 ventricular arrhythmic episodes reported in 7 studies with available data, 65 required shock therapy, corresponding to a shock proportion of 97.0% (95% CI: 89.6–99.6%). Conclusion Arrhythmic MVP patients with ICDs for secondary prevention exhibit a high risk of recurrent arrhythmias, with recurrences in the form of polymorphic VA occurring in more than half of the cases. PROSPERO registration number: CRD42024588610
Abstract 4366487: Artificial Intelligence-Enabled Electrocardiogram for the Detection of Elevated Filling Pressure in Hypertrophic Cardiomyopathy and Cardiac Amyloidosis
Lerberghe, Robin Van, Servaes, Veerle, Robyns, Tomas , Aelst, Lucas Van , Mangold, Kathryn, Oh, Jae K. , Grogan, Martha, Friedman, Paul A. , Herrmann, Joerg, Janssens, Stefan , Robyns, Tomas , Van Aelst, Lucas N L , Vandenberk, Bert , Jacobs, Johanna, Attia, Zachi I. , Oh, Jae K. , Grogan, Martha , Herrmann, Joerg

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4366487 Get It

Introduction: Diastolic dysfunction is a hallmark of heart failure with preserved ejection fraction, yet echocardiographic grading is challenging in patients with hypertrophic or amyloid cardiomyopathies due to variable structural and functional remodeling. Consequently, there is a need for additional diagnostic tools to identify patients at increased risk of diastolic dysfunction and enhanced filling pressure. Research Question: What is the accuracy of an artificial intelligence (AI)-enabled electrocardiogram (ECG) model to predict diastolic dysfunction in hypertrophic and amyloid cardiomyopathy? Methods: We included patients with diverse phenotypes of hypertrophic cardiomyopathy (HCM) and cardiac amyloidosis and validated Mayo Clinic's AI-enabled ECG model to grade diastolic function (normal: grade 0/1; abnormal: grade 2/3). Echocardiographic analysis of systolic (LVEF) and diastolic function was performed within 14 days of ECG recording. Diastolic function was graded based on E/e’ (>14), left atrial volume index (>34 mL/m2), pulmonary venous atrial reversal flow duration (≥30 ms), and peak tricuspid regurgitation velocity (>2.8 m/s). Filling pressure was considered increased if ≥3 parameters were abnormal, inconclusive if 2 were abnomal, and normal if ≥3 were normal. Echocardiograms with severe mitral regurgitation were excluded. Results: We identified and matched 840 ECGs from non-obstructive HCM patients (n=125, age 58±19y, 70% male), 145 ECGs from obstructive HCM patients (n=29, age 56±18y, 66% male), 225 ECGs from apical HCM patients (n=33, age 66±14y, 61% male), and 382 ECGs from cardiac amyloidosis patients (n=49, age 70±13y, 57% male). The AI-enabled ECG model predicted diastolic dysfunction with an accuracy of 65% (non-obstructive HCM), 67% (obstructive HCM), 65% (apical HCM), and 75% (cardiac amyloidosis), with sensitivities of 94% and 97% for obstructive HCM and cardiac amyloidosis, respectively, and high positive and negative predictive values for cardiac amyloidosis. Systolic dysfunction (LVEF≤40%) was more common in cardiac amyloidosis (29%) than in all HCM patients (5%). Conclusion: The AI-enabled ECG model demonstrates moderate accuracy but high sensitivity for detecting diastolic dysfunction and increased filling pressure, especially in obstructive HCM and cardiac amyloidosis. The AI-enabled ECG is a useful, widely scalable, and low cost tool to identify patients at increased risk for diastolic dysfunction.
Abstract 18324: Artificial Intelligence ECG as a Novel Method to Detect Cardiotoxicity After Anthracyclines
Jacobs, J. , Greason, Grace , Willems, Rik , Janssens, Stefan , Voigt, Jens‐Uwe , Friedman, Paul A. , Aelst, Lucas Van , Herrmann, Joerg , Jacobs, Johanna E J , Van Aelst, Lucas N L , Voigt, Jens-Uwe , Wildiers, Hans , Noseworthy, Peter A. , López-Jiménez, Francisco , Vandenberk, Bert , Attia, Zachi I.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18324 Get It

Introduction: Cardiotoxicity is a serious side effect of anthracycline treatment, most commonly manifesting as a reduction in left ventricular ejection fraction (LVEF) on cardiac imaging. Cost-effective alternatives to cardiac imaging are currently not available. Artificial intelligence (AI) models have been developed to detect a reduced LVEF from 12-lead electrocardiograms (ECGs) in the general population. Hypothesis: AI-ECG model can detect a reduced LVEF after anthracycline therapy (i.e. cardiotoxicity). Methods: We included an unbiased oncological population of 989 female breast cancer patients receiving (neo)adjuvant anthracycline chemotherapy. Average follow-up time was 9.83±4.2 years. Patients with incomplete transthoracic echocardiography (TTE) data, HER-2-directed therapy, significant comorbidities, upfront metastatic disease, second primary malignancy or pre-existing cardiovascular disease were excluded from the analyses. Patients with LVEF decline for reasons other than anthracycline-induced cardiotoxicity were also excluded. Primary readout was the diagnostic performance of AI-ECG by area under the curve (AUC) for various levels of LVEF <50%. Results: Using 1,877 ECGs from 703 unique patients, the AI-ECG model detected an LVEF <50% and ≤35% after anthracycline therapy with an AUC of 0.93 and 0.94, respectively. Conclusions: These data support the use of AI-ECG for cardiomyopathy (cardiotoxicity) screening after anthracycline-based chemotherapy. This technology could serve as a gatekeeper to more costly testing and could enable patients to monitor themselves over long periods of time.
Artificial intelligence electrocardiogram as a novel screening tool to detect a newly abnormal left ventricular ejection fraction after anthracycline-based cancer therapy
Jacobs, J. , Greason, Grace , Mangold, Kathryn, Wildiers, Hans , Willems, Rik , Janssens, Stefan , López-Jiménez, Francisco , Voigt, Jens‐Uwe , Friedman, Paul A. , Aelst, Lucas Van , Vandenberk, Bert , Attia, Zachi Itzhak, Herrmann, Joerg , Jacobs, Johanna E J , Mangold, Kathryn E, Lopez-Jimenez, Francisco , Voigt, Jens-Uwe , Van Aelst, Lucas N L , Wildiers, Hans , Noseworthy, Peter A. , Vandenberk, Bert , Attia, Zachi I.

European Journal of Preventive Cardiology | November 6, 2023 | Volume: 31 | Issue: 5 | Pages: 560-566

10.1093/eurjpc/zwad348 Get It

Abstract Aims Cardiotoxicity is a serious side effect of anthracycline treatment, most commonly manifesting as a reduction in left ventricular ejection fraction (EF). Early recognition and treatment have been advocated, but robust, convenient, and cost-effective alternatives to cardiac imaging are missing. Recent developments in artificial intelligence (AI) techniques applied to electrocardiograms (ECGs) may fill this gap, but no study so far has demonstrated its merit for the detection of an abnormal EF after anthracycline therapy. Methods and results Single centre consecutive cohort study of all breast cancer patients with ECG and transthoracic echocardiography (TTE) evaluation before and after (neo)adjuvant anthracycline chemotherapy. Patients with HER2-directed therapy, metastatic disease, second primary malignancy, or pre-existing cardiovascular disease were excluded from the analyses as were patients with EF decline for reasons other than anthracycline-induced cardiotoxicity. Primary readout was the diagnostic performance of AI-ECG by area under the curve (AUC) for EFs &lt; 50%. Of 989 consecutive female breast cancer patients, 22 developed a decline in EF attributed to anthracycline therapy over a follow-up time of 9.8 ± 4.2 years. After exclusion of patients who did not have ECGs within 90 days of a TTE, 20 cases and 683 controls remained. The AI-ECG model detected an EF &lt; 50% and ≤ 35% after anthracycline therapy with an AUC of 0.93 and 0.94, respectively. Conclusion These data support the use of AI-ECG for cardiotoxicity screening after anthracycline-based chemotherapy. This technology could serve as a gatekeeper to more costly cardiac imaging and could enable patients to monitor themselves over long periods of time.
2023 HRS/EHRA/APHRS/LAHRS Expert Consensus Statement on Practical Management of the Remote Device Clinic
Ferrick, Aileen M., Kojodjojo, Pipin , López-Cabanillas, Néstor , Chew, Derek S. , Choi, Jong‐Il , Dagres, Nikolaos , Dalal, Aarti , Dechert, Brynn E. , Frazier‐Mills, Camille, Gilbert, Olivia , Hewit, Sherri, Kneeland, Christine , Mirza, Starr DeEllen, Runté, Mary, Sinclair, Susan, Teixeira, Ricardo Alkmim , Vandenberk, Bert , Davenport, Elizabeth , Freedenberg, Vicki , Glotzer, Taya V. , Ikeda, Takanori , Kramer, Daniel B. , Lin, David , Rojel-Martínez, Ulises, Stühlinger, Markus , Varosy, Paul D. , Dagres, Nikolaos , Raj, Satish R , Deneke, Thomas , Abe, Haruhiko , Bovéda, Serge , Han, Janet K. , Hewit, Sherri, Mittal, Suneet , Ricci, Renato Pietro , Teixeira, Ricardo Alkmim , Vandenberk, Bert , Varma, Niraj , Huang, Jin‐Long

Europace | May 20, 2023 | Volume: 25 | Issue: 5 | Pages: No page available

10.1093/europace/euad123 Get It

Abstract Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.
2023 HRS/EHRA/APHRS/LAHRS Expert Consensus Statement on Practical Management of the Remote Device Clinic
Ferrick, Aileen M., Kojodjojo, Pipin , López-Cabanillas, Néstor , Chew, Derek S. , Choi, Jong‐Il , Dagres, Nikolaos , Dalal, Aarti , Dechert, Brynn E. , Frazier‐Mills, Camille, Gilbert, Olivia , Hewit, Sherri, Kneeland, Christine , Mirza, Starr DeEllen, Runté, Mary, Sinclair, Susan, Teixeira, Ricardo Alkmim , Vandenberk, Bert , Reviewers, Document, Davenport, Elizabeth , Freedenberg, Vicki , Glotzer, Taya V. , Ikeda, Takanori , Kramer, Daniel B. , Lin, David , Rojel‐Martínez, Ulises, Stühlinger, Markus , Varosy, Paul D. , Huang, Jin-Long, Rojel-Martínez, Ulises, Dagres, Nikolaos , Raj, Satish R , Deneke, Thomas , Abe, Haruhiko , Bovéda, Serge , Han, Janet K. , Mittal, Suneet , Ricci, Renato Pietro , Teixeira, Ricardo Alkmim , Vandenberk, Bert , Varma, Niraj , Reviewers, Document, Huang, Jin‐Long

Journal of Arrhythmia | May 19, 2023 | Volume: 39 | Issue: 3 | Pages: 250-302

10.1002/joa3.12851 Get It

AbstractRemote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third‐party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence‐based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.