Back to Authors

Oh, Jae K.

0000-0002-8303-5780

Mayo Clinic

Mayo Clinic

Citations 20

Prognostic Value of Artificial Intelligence ECG–Derived Diastolic Function in Surgical Aortic Valve Replacement
Sawma, Tedy , Schaff, Hartzell V. , Danesh, Sina , Arghami, Arman , Lee, Eunjung , Aslahishahri, Masoomeh, Stulak, John, Greason, Kevin L. , Dearani, Joseph A. , López-Jiménez, Francisco , Friedman, Paul A. , Oh, Jae K. , Dearani, Joseph A. , Greason, Kevin , Sabbah, Michael S. , Attia, Zachi I , Oh, Jae K. , Crestanello, Juan A , Lopez-Jimenez, Francisco , Arghami, Arman , Schaff, Hartzell , Stulak, John M., Pislaru, Sorin V. , Attia, Zachi I. , Crestanello, Juan A.

Journal of the American Heart Association | August 31, 2026 | Volume: 15 | Issue: 19 | Pages: No page available

10.1161/jaha.126.050492 Get It

Background Diastolic dysfunction is common in patients with aortic stenosis and may influence outcomes following surgical aortic valve replacement. We aimed to examine the association of preoperative artificial intelligence (AI)‐generated diastolic function grades with early and late outcomes following aortic valve replacement and how postoperative progression influence prognosis. Methods We identified 5503 patients undergoing aortic valve replacement between 2000 and 2023. Diastolic function was assessed using a validated deep‐learning AI model applied to 12‐lead ECGs done preoperatively and on postoperative follow‐up. Diastolic grades were classified by AI into Grades 1 to 3. Longitudinal trend analyses and multivariable regression models were used to assess study end points. Results Among 5503 patients (mean age 72.4±10.8 years; 39% female), higher AI ECG diastolic grades were associated with greater comorbidity burden, including diabetes, renal disease, and heart failure. AI ECG diastolic Grade 3 was independently associated with higher in‐hospital mortality (odds ratio, 2.5; P =0.007) and other complications. At 5‐year follow‐up, patients with Grade 3 showed the least improvement in diastolic function by both ECG and echocardiography. Grades 2 and 3 diastolic function at baseline were independently associated with increased late mortality (hazard ratio, 1.3 and 2.45, respectively; both P <0.001). Additionally, lack of improvement in AI ECG diastolic grade by 1 year was also independently associated with late mortality. Conclusions AI ECG–derived diastolic function grades strongly correlates with early complications and long‐term mortality and diastolic progression after aortic valve replacement. AI ECG provides a powerful, noninvasive tool for risk stratification and longitudinal monitoring of patients with aortic stenosis.
Echocardiography-Based, Artificial Intelligence-Enabled Electrocardiography (AI-ECG) for Diastolic Hemodynamics Phenotyping in Acute Heart Failure (AHF)
Wong, Yee Weng, Abbasi, Muhannad , Lee, Eunjung , Tsaban, Gal, Attia, Zachi I. , Friedman, Paul A., Noseworthy, Peter A. , Lopez-Jimenez, F., Chen, H H, Lin, Grace , Scott, Luis R. , Ezzeddine, Omar F. Abou, Oh, Jae K., López-Jiménez, Francisco , Noseworthy, Peter A , Lopez-Jimenez, Francisco , Attia, Zachi I , Lin, Grace , Wong, Yee W , Tsaban, Gal , Friedman, Paul A. , Chen, Horng H. , AbouEzzeddine, Omar F. , Oh, Jae K.

No container title available | March 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.03.05.26347763 Get It

ABSTRACT Background Acute heart failure (AHF) exhibits marked heterogeneity in diastolic hemodynamics, yet comprehensive echocardiographic assessment of diastolic function (DF) and filling pressure (FP) is often infeasible. We evaluated whether artificial intelligence–enabled electrocardiography (AI-ECG) could provide scalable DF grading and FP estimation in hospitalized AHF patients. Methods We retrospectively studied adults hospitalized for AHF across Mayo Clinic sites (2013–2023) who received ≥1 dose of intravenous loop diuretic and had paired 12-lead ECG and TTE. The previously validated AI-ECG DF model was applied without retraining to generate four DF grades and a continuous FP probability. Clinical outcomes were all-cause mortality and heart failure rehospitalization. Associations with clinical severity markers and echocardiographic indices were examined. Kaplan–Meier survival analysis and adjusted multivariable Cox proportional hazards models were performed. Exploratory analyses examine the kinetics of change in FP probability and impact on mortality. Results Among 11,513 patients (median age 75 years, 39% female), AI-ECG DF grading was feasible in 100%, whereas echocardiographic DF was indeterminate in 44% of clinically eligible patients. In 2,582 patients with determinate echocardiographic DF, AI-ECG FP probability discriminated TTE Grade 2–3 dysfunction with AUC 0.85 (95% CI 0.83 – 0.86). Higher AI-ECG DF grades were associated with higher comorbidity burden, worse NYHA class, elevated NT-proBNP, higher MAGGIC scores, elevated PCWP, and more advanced structural remodeling. After multivariable adjustment, AI-ECG DF remained independently associated with mortality (hazard ratio [HR] 1.25, 95% CI 1.16–1.35 for Grade 2; HR 1.44, 95% CI 1.33–1.56 for Grade 3 versus Normal/Grade 1). Combining AI-ECG DF with MAGGIC scores yielded ordered risk gradients, with highest mortality in patients with both high MAGGIC and Grade 2–3 DF. Among patients with serial ECGs, improvement in FP probability was independently associated with lower mortality (HR 0.85, 95% CI 0.79–0.91), whereas worsening did not show a consistent adverse gradient beyond baseline DF. Conclusions In a large, geographically diverse AHF cohort, AI-ECG DF grading was universally feasible, correlated with established hemodynamic severity markers, and provided independent prognostic information beyond established risk factors, supporting its role as a pragmatic, scalable diastolic biomarker in AHF. CLINICAL PERSPECTIVE What Is New? In 11,513 hospitalized acute heart failure (HF) patients, artificial intelligence-enabled electrocardiography provided diastolic function grading in 100% of patients from a single 12-lead ECG without requiring additional clinical variables, compared with 56% feasibility for guideline-based echocardiography grading. AI-ECG diastolic function grades correlated with established marker of severity (NYHA functional class, NT-proBNP, MAGGIC risk scores, and pulmonary capillary wedge pressure) and remained independently associated with both mortality and HF rehospitalization after multivariable adjustment. Serial AI-ECG measurements identified post-discharge filling pressure trajectories, with improvement independently associated with 15% lower mortality, a first demonstration that longitudinal ECG assessment can track post-discharge hemodynamic recovery. What Are the Clinical Implications? AI-ECG transforms the universally obtained 12-lead ECG into an actionable hemodynamic biomarker that addresses the critical gap when echocardiographic diastolic function assessment is indeterminate or unavailable in acute HF patients. Despite markedly different hemodynamic severity and long-term outcomes across AI-ECG diastolic function grades, hospitalization length of stay did not differ, suggesting advanced diastolic dysfunction represents occult risk not easily recognized during routine acute care and highlighting the need for improved post-discharge risk stratification. The continuous filling pressure probability metric enables longitudinal monitoring of post-discharge hemodynamic status using serial routine ECGs, potentially identifying patients requiring intensified follow-up or specialist referral.
Prognostic Value of Artificial Intelligence–Enabled Electrocardiography–Derived Diastolic Dysfunction Grading and Trajectory in Patients Undergoing Transcatheter Aortic Valve Replacement
Tsai, Chieh-Mei , Naser, Jwan A. , Tsaban, Gal, Lee, Eunjung , Wood, Julia, Luis, Allen S., Thaden, Jeremy J. , Kane, Garvan C., Pislaru, Sorin V. , Simard, Trevor J., Greason, Kevin L. , Eleid, Mackram F., Oh, Jae K., Kane, Garvan C. , Simard, Trevor , Tsaban, Gal , Luis, Sushil A , Simard, Trevor , Eleid, Mackram F , Nkomo, Vuyisile T , Oh, Jae K. , Sabbah, Michael S. , Naser, Jwan A , Tsaban, Gal , Eleid, Mackram F. , Nkomo, Vuyisile T. , Oh, Jae K.

Journal of the American Heart Association | January 30, 2026 | Volume: 15 | Issue: 3 | Pages: No page available

10.1161/jaha.125.046558 Get It

Background Artificial intelligence (AI)–enabled electrocardiography has emerged as a tool for detecting cardiac dysfunction. The prognostic relevance of AI‐enabled electrocardiography–derived diastolic dysfunction (DD) in patients undergoing transcatheter aortic valve replacement had not been assessed. Methods We analyzed 3197 patients undergoing transcatheter aortic valve replacement for severe aortic stenosis between 2010 and 2023 with baseline 12‐lead ECGs processed by a validated AI model to classify diastolic function (grades 0–3). Multivariable Cox models and nested model comparisons assessed associations with all‐cause mortality, including a prespecified analysis in patients with indeterminate echocardiographic grading. Trajectories were defined by change in AI‐enabled electrocardiography DD grade (<2 versus ≥2) from baseline to 30‐day or 1‐year follow‐up. Results At baseline, 21% had grade 3, 57% had grade 2, 8% had grade 1, and 14% had grade 0 AI‐enabled electrocardiography DD. Higher grades were associated with adverse cardiac remodeling and comorbidities. Over a median follow‐up of 3.4 years, grade 3 AI‐enabled electrocardiography DD independently predicted mortality (hazard ratio [HR], 1.80 [95% CI, 1.47–2.20]; P <0.001). AI‐enabled electrocardiography DD improved prognostic discrimination beyond clinical and echocardiographic measures (ΔHarrell concordance statistic, 0.016; Δ χ 2 =57; P <0.001). Among 1259 patients with indeterminate echocardiographic grading, AI‐enabled electrocardiography added prognostic value (ΔHarrell concordance statistic, 0.02; Δ χ 2 =13; P =0.006). Worsening or persistently high‐risk trajectories were associated with increased mortality (HRs, 1.45–1.80; all P <0.05). Conclusions AI‐enabled electrocardiography–derived DD independently predicts mortality after transcatheter aortic valve replacement, adds value beyond echocardiographic grading, and enables dynamic risk stratification through longitudinal tracking.
Abstract 4366487: Artificial Intelligence-Enabled Electrocardiogram for the Detection of Elevated Filling Pressure in Hypertrophic Cardiomyopathy and Cardiac Amyloidosis
Lerberghe, Robin Van, Servaes, Veerle, Robyns, Tomas , Aelst, Lucas Van , Mangold, Kathryn, Oh, Jae K. , Grogan, Martha, Friedman, Paul A. , Herrmann, Joerg, Janssens, Stefan , Robyns, Tomas , Van Aelst, Lucas N L , Vandenberk, Bert , Jacobs, Johanna, Attia, Zachi I. , Oh, Jae K. , Grogan, Martha , Herrmann, Joerg

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4366487 Get It

Introduction: Diastolic dysfunction is a hallmark of heart failure with preserved ejection fraction, yet echocardiographic grading is challenging in patients with hypertrophic or amyloid cardiomyopathies due to variable structural and functional remodeling. Consequently, there is a need for additional diagnostic tools to identify patients at increased risk of diastolic dysfunction and enhanced filling pressure. Research Question: What is the accuracy of an artificial intelligence (AI)-enabled electrocardiogram (ECG) model to predict diastolic dysfunction in hypertrophic and amyloid cardiomyopathy? Methods: We included patients with diverse phenotypes of hypertrophic cardiomyopathy (HCM) and cardiac amyloidosis and validated Mayo Clinic's AI-enabled ECG model to grade diastolic function (normal: grade 0/1; abnormal: grade 2/3). Echocardiographic analysis of systolic (LVEF) and diastolic function was performed within 14 days of ECG recording. Diastolic function was graded based on E/e’ (>14), left atrial volume index (>34 mL/m2), pulmonary venous atrial reversal flow duration (≥30 ms), and peak tricuspid regurgitation velocity (>2.8 m/s). Filling pressure was considered increased if ≥3 parameters were abnormal, inconclusive if 2 were abnomal, and normal if ≥3 were normal. Echocardiograms with severe mitral regurgitation were excluded. Results: We identified and matched 840 ECGs from non-obstructive HCM patients (n=125, age 58±19y, 70% male), 145 ECGs from obstructive HCM patients (n=29, age 56±18y, 66% male), 225 ECGs from apical HCM patients (n=33, age 66±14y, 61% male), and 382 ECGs from cardiac amyloidosis patients (n=49, age 70±13y, 57% male). The AI-enabled ECG model predicted diastolic dysfunction with an accuracy of 65% (non-obstructive HCM), 67% (obstructive HCM), 65% (apical HCM), and 75% (cardiac amyloidosis), with sensitivities of 94% and 97% for obstructive HCM and cardiac amyloidosis, respectively, and high positive and negative predictive values for cardiac amyloidosis. Systolic dysfunction (LVEF≤40%) was more common in cardiac amyloidosis (29%) than in all HCM patients (5%). Conclusion: The AI-enabled ECG model demonstrates moderate accuracy but high sensitivity for detecting diastolic dysfunction and increased filling pressure, especially in obstructive HCM and cardiac amyloidosis. The AI-enabled ECG is a useful, widely scalable, and low cost tool to identify patients at increased risk for diastolic dysfunction.
Artificial Intelligence ECG Diastolic Dysfunction and Survival in Cardiac Intensive Care Unit Patients
Jentzer, Jacob C. , Lee, Eunjung , Attia, Zachi I. , Kane, Garvan C. , López-Jiménez, Francisco , Noseworthy, Peter A. , Friedman, Paul A. , Oh, Jae K. , Attia, Zachi I , Hillerson, Dustin , Lopez-Jimenez, Francisco , Noseworthy, Peter A , Friedman, Paul A , Oh, Jae K. , Jentzer, Jacob C

Journal of the American Heart Association | February 19, 2025 | Volume: 14 | Issue: 5 | Pages: No page available

10.1161/jaha.124.037839 Get It

Background Left ventricular diastolic dysfunction (LVDD) predicts mortality in patients in cardiac intensive care units. An artificial intelligence enhanced ECG (AIECG) algorithm can predict LVDD and mortality in general populations but has not been examined in cardiac intensive care units. Methods This historical cohort study included consecutive adults admitted to Mayo Clinic cardiac intensive care unit from 2007 to 2018 with an admission AIECG. The AIECG assigned the LVDD grade (0–3). Medial mitral E/e' ratio >15 on transthoracic echocardiogram (TTE) defined elevated filling pressures. In‐hospital and 1‐year mortality was evaluated, before and after multivariable adjustment. Results We included 11 868 patients (median age 69.5 years, 37.7% female); 48% had heart failure and 44% had acute coronary syndromes. AIECG LVDD grade was 0 (normal), 33%; 1, 7%; 2, 39%; and 3, 21%. In‐hospital and 1‐year mortality increased in each higher AIECG LVDD grade. After adjustment, each higher AIECG LVDD grade was associated with higher in‐hospital (adjusted odds ratio [OR], 1.22 [95% CI, 1.13–1.32]) and 1‐year mortality (adjusted hazard ratio [HR], 1.23 [95% CI, 1.19–1.29]); this persisted after adjustment for TTE measurements. Patients with grade 2 or 3 LVDD by AIECG and medial mitral E/e' ratio >15 by TTE had the highest in‐hospital (adjusted OR, 2.54 [95% CI, 1.69–3.88]) and 1‐year (adjusted HR, 2.03 [95% CI, 1.65–2.48]) mortality, whereas patients meeting either of these criteria had similar, elevated mortality. Conclusions The AIECG LVDD grade was strongly associated with in‐hospital and 1‐year mortality in patients in cardiac intensive care units, even after adjusting for clinical variables and TTE measurements. Patients with concordant AIECG and TTE for elevated filling pressures were at highest risk.
Artificial intelligence-enhanced electrocardiogram left ventricular diastolic function assessment for prognostic assessment in mitral annulus calcification
Tsaban, Gal , Lee, Emma , Wong, Y.W. James, Wopperer, Samuel B., Abbasi, Mokhtar Ali, Eleid, M, Deshmukh, A J, Friedman, Paul A. , Oh, Jae K. , Abbasi, M A, Kane, Garvan C. , López-Jiménez, Francisco , Guerrero, Mayra , Eleid, M, Nkomo, Vuyisile T. , Noseworthy, Peter A. , Attia, I, Oh, Jae K.

European Heart Journal - Cardiovascular Imaging | January 29, 2025 | Volume: 26 | Issue: Supplement_1 | Pages: No page available

10.1093/ehjci/jeae333.087 Get It

Abstract Background Moderate-severe mitral annulus calcification (MAC) and left ventricular (LV) diastolic dysfunction are both linked to increased risks of heart failure and mortality. Assessing LV diastolic function (LVDF) in moderate-severe-MAC by echocardiography is frequently challenging and unreliable. We recently validated an AI-ECG model for LVDF. We aimed to determine if this tool can predict long-term mortality in patients with moderate-severe-MAC and whether it can help establish MAC-specific echocardiographic LVDF parameter cutoffs. Methods This retrospective study included all patients from the AI-ECG LVDF study test cohort who underwent comprehensive transthoracic echocardiography confirming moderate-severe-MAC and ECG within fourteen days of each other at Mayo Clinic between 09/2001 and 06/2022. AI-ECG LVDF was determined based on the index ECG. Patients were categorized based on AI-ECG into groups representing normal/grade-1 LVDF, grade-2 LVDF, or grade-3 LVDG (DF-1, DF-2, and DF-3, respectively). Results Of 2,506 patients with moderate-severe-MAC [mean age 77, 64.1% females], 709 (28.3%), 1,510 (60.3%), and 287 (11.5%) were classified as DF-1, DF-2, and DF-3, respectively. Worse LVDF grade was associated with older age, male sex, lower LV ejection fraction, and higher rates of noncardiovascular and cardiovascular comorbidities. Over a median follow-up of 2.8 years, 1,059 (42.3%) patients died. In multivariable survival analysis, DF-2 [adjusted hazard ratio (aHR) 1.43, 95% confidence interval (95%CI) 1.21-1.68] and DF-3 (aHR 1.54, 95%CI 1.22-1.93) were independently associated with a higher risk of death (figure). Findings were also consistent after adjusting to mitral inflow gradients. When comparing LVDF echocardiographic parameters in controls without MAC matched by age, sex, left ventricular ejection fraction, and AI-ECG DF grade, significant differences were observed. Patients with moderate to severe MAC generally exhibited lower e' velocities, higher TR velocities, elevated E/e' ratios, and increased LAVi. Interestingly, the E/A ratio between MAC patients and their matched controls across AI-ECG LVDF grades remained consistent. Conclusion AI-ECG LVDF predicts mortality risk in patients with moderate-severe-MAC, regardless of mitral inflow gradients. Utilizing AI-ECG LVDF might aid in the risk stratification of patients with significant MAC.
A new paradigm for structural heart disease detection: cost savings of screening with AI-ECG and POCUS
Schlesinger, Reid, Alexandrino, Francisco B. , Bird, Jared, Deshmukh, Abhishek , Oh, Jae K. , Friedman, Paul J., Tsaban, Gal , Schlesinger, Reid P , Kane, Garvan C. , Pellikka, Patricia A. , Oh, Jae K. , Noseworthy, Peter A. , López-Jiménez, Francisco , Friedman, P, Pislaru, Sorin V.

European Heart Journal - Cardiovascular Imaging | January 29, 2025 | Volume: 26 | Issue: Supplement_1 | Pages: No page available

10.1093/ehjci/jeae333.017 Get It

Abstract Background AI-enhanced electrocardiogram (AI-ECG) is a cost-effective tool for left ventricular dysfunction screening. However, its cost-effectiveness for other forms of structural heart disease (SHD) is unknown. While AI-ECG is inexpensive, the relatively low positive predictive value (PPV) of many models can lead to high costs from unnecessary follow-up tests like transthoracic echocardiography (TTE). Therefore, strategies to improve the yield of AI-ECG-based screening are needed. Purpose To evaluate the cost savings of a stepwise approach to SHD screening using AI-ECG followed by point-of-care ultrasound (POCUS) compared to AI-ECG alone. Methods 286 adult outpatients undergoing AI-ECG were randomly selected to undergo same-day POCUS. All participants were required to have a recent TTE, our gold standard for SHD diagnosis, for comparison purposes. We evaluated four SHDs: aortic stenosis, cardiac amyloidosis, hypertrophic cardiomyopathy, and left ventricular dysfunction (defined as left ventricular ejection fraction &lt;50%). The costs of AI-ECG ($75/test) and TTE ($1,305/test) were sourced from Healthcare Bluebook, while the cost of POCUS ($100/test) was independently estimated. We compared the costs of screening with AI-ECG alone to stepwise screening with AI-ECG followed by POCUS. Costs were analyzed for two paradigms: screening for all forms of SHD in parallel and screening for each SHD individually. Results AI-ECG alone identified potential SHD in 125 out of 286 patients. When compared to TTE, only 39 out of 125 were true positives (31% PPV). Among the AI-ECG-positive patients, POCUS demonstrated findings of SHD in 52 out of 125 cases. When compared to TTE, this stepwise approach yielded 32 true positives and 20 false positives (62% PPV). In the parallel screening paradigm, the cost per patient diagnosed with SHD was $4,733 with AI-ECG alone, which decreased to $3,182 with stepwise screening (33% cost savings). For the individual SHD screening paradigm, cost reductions were as follows: aortic stenosis ($18,724 to $6,315, 66% savings), cardiac amyloidosis ($21,023 to $12,230, 42% savings), hypertrophic cardiomyopathy ($9,883 to $6,175, 38% savings), and left ventricular dysfunction ($4,019 to $3,582, 11% savings). Conclusions Stepwise SDH screening with AI-ECG followed by POCUS markedly reduces costs compared to AI-ECG alone. The greatest cost savings for individual SHD screening were observed for aortic stenosis and cardiac amyloidosis, conditions where AI-ECG models have lower PPVs. Parallel screening for multiple SHDs is also less costly than screening for any individual SHD alone. Therefore, a parallel screening approach may maximize SHD detection while minimizing screening costs. Stepwise Screening Approach for SHD SDH Screening Costs
Global longitudinal strain is a predictor of mortality in patients with cardiogenic shock
Berg‐Hansen, Kristoffer , Ito, Saki , Oh, Jae K. , Yang, Jeong Hoon , Oh, Jae, Wiggers, Henrik , Ito, Saki , Oh, Jae K. , Jentzer, Jacob C.

European Heart Journal - Cardiovascular Imaging | December 5, 2024 | Volume: 26 | Issue: 4 | Pages: 643-653

10.1093/ehjci/jeae316 Get It

Abstract Aims Cardiogenic shock (CS) is a critical manifestation of severe cardiac dysfunction, necessitating precise evaluation of left ventricular (LV) function by transthoracic echocardiography. The prognostic value of global longitudinal strain (GLS) has not been examined in patients with CS. Therefore, we aimed to assess the prognostic significance of GLS in patients with CS. Methods and results This was a retrospective study of patients with CS from 2007 to 2018 who had a transthoracic echocardiography performed within 24 h of admission. GLS was measured, and conventional parameters were obtained. LV dysfunction was categorized by GLS: &gt; 9.7% (Quartile 1), 7.0% &lt; GLS ≤ 9.7% (Quartile 2), 5.0% &lt; GLS ≤ 7.0% (Quartile 3), and ≤5.0% (Quartile 4). Outcomes included in-hospital and 1-year all-cause mortality. Among 623 patients with CS with the median LVEF of 31% [inter-quartile range (IQR): 24–41%] and the median GLS of 7.0% (IQR: 5.0–9.7%), in-hospital mortality was 29%. Mortality increased across GLS quartiles: Quartile 1: 17%; Quartile 2: 22%; Quartile 3: 35%; and Quartile 4: 42%. GLS remained the only independent echocardiographic predictor of in-hospital mortality after adjusting for clinical covariates (adjusted odds ratio: 1.23 per 1% decrease, 95% confidence interval: 1.04–1.46, P = 0.015). GLS independently predicted 1-year all-cause mortality (P &lt; 0.001). The prognostic value of GLS was superior in cases with acute coronary syndrome. A classification and regression tree analysis identified GLS as the most important echocardiographic variable for predicting in-hospital mortality. Conclusion GLS independently predicted short- and long-term mortality in patients with CS, surpassing conventional echocardiographic parameters in prognostic value, supporting its potential role in risk stratification in this population.
Abstract 4144907: Left ventricular-arterial coupling and mortality in the cardiac intensive care unit
Fazzini, Luca, Berg, K. , Oh, Jae K. , Kane, Garvan C. , Berg‐Hansen, Kristoffer , Padkins, Mitchell , Fazzini, Luca , Berg, Kristoffer, Gori, Mauro , Oh, Jae K. , Hillerson, Dustin , Tavazzi, Guido , Jentzer, Jacob C.

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4144907 Get It

Background: Ventricular-arterial coupling (VAC) refers to the ratio of afterload (effective arterial elastance) to contractility (left ventricular (LV) end-systolic elastance) as an integrated marker of cardiac performance. Echocardiography might be used to evaluate VAC through a simple time-efficient bedside evaluation. Hypothesis: VAC is useful for mortality risk stratification in an unselected cardiac intensive care unit (CICU) cohort. Aims: We sought to determine whether the VAC ratio, defined using the ratio of LV end-systolic volume (LVESV) to stroke volume (SV), predicted mortality in the CICU. Methods: Consecutive patients admitted to the Mayo Clinic CICU between 2007 and 2018 were included. The simplified VAC ratio was calculated as the LVESV calculated from 2D measurements using the Teichholz formula divided by the SV calculated from the LV outflow tract pulsed wave Doppler measurement, with values >1 reflecting ventricular-arterial uncoupling. The main outcome was all-cause in-hospital mortality. Results: We included 4685 patients with a median age of 69 (58-79) years; 37% were females. The median VAC ratio was 1.0 (0.7 to 1.8) and 21% of patients had a VAC ratio >2. Most clinical and echocardiographic variables differed in patients with higher VAC ratio, reflecting greater severity of illness with worse cardiac systolic and diastolic function. A total of 329 (7.0%) patients died during hospitalization. An incremental association was observed between a higher VAC and in-hospital mortality (unadjusted OR 1.22, 95% CI 1.16-1.29, p<0.001). Patients with a VAC ratio >1 (unadjusted OR 2.85, 95% CI 2.22-3.69, p <0.001) and especially those with VAC ratio >2 (unadjusted OR 4.28, 95% CI 3.24-5.69, p<0.001) had higher in-hospital mortality overall and in each admission diagnosis subgroup of interest ( Figure ). After multivariable adjustment, patients with a VAC ratio >2 remained at higher risk of in-hospital mortality (adjusted OR 1.63, 95% CI 1.17-2.28, p = 0.01). Conclusions: Ventricular-arterial uncoupling was associated with worse outcomes in an unselected CICU cohort. The echocardiographic VAC ratio is a simple non-invasive bedside measure that can be used for risk prediction in the CICU.
Abstract 4142502: Stepwise Screening with AI-Enhanced Electrocardiogram and Point-of-Care Ultrasound Improves Cost Savings of Structural Heart Disease Detection Compared to AI-Enhanced Electrocardiogram Alone
Schlesinger, Reid, Alexandrino, Francisco B. , Bird, Jared, Kane, Garvan C. , Deshmukh, Abhishek , Oh, Jae K. , Lopez‐Jimenez, Francisco, Friedman, Paul A. , Tsaban, Gal , Schlesinger, Reid P , Pellikka, Patricia A. , Oh, Jae K. , Noseworthy, Peter A. , López-Jiménez, Francisco , Pislaru, Sorin V.

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4142502 Get It

Background: AI-ECG is a cost-effective tool for left ventricular dysfunction (LVD) screening. However, its cost-effectiveness for other forms of structural heart disease (SHD) is unknown. While AI-ECG is inexpensive, a drawback is low positive predictive value (PPV), which leads to high costs from unnecessary follow-up tests. Therefore, strategies to improve the yield of AI-ECG-based screening are needed. Aim: To evaluate the cost savings of a stepwise approach to SHD screening with AI-ECG followed by POCUS compared to AI-ECG alone. Methods: 286 adult outpatients undergoing AI-ECG were selected at random. Participants received same-day POCUS and had a recent TTE (our gold standard for SHD). We evaluated four SHDs: aortic stenosis (AS), cardiac amyloidosis (CA), HCM, and LVD. The costs of AI-ECG ($75) and TTE ($1,305) were obtained from Healthcare Bluebook. The cost of POCUS ($100) was estimated independently. Cost savings were analyzed for simultaneous screening for all forms of SHD and screening for individual SHDs. Results: AI-ECG identified potential SHD in 125 patients, but only 39 were true positives by TTE (31% PPV). In AI-ECG positive patients, POCUS demonstrated findings of SHD in 52/125. Compared to TTE, this stepwise approach yielded 32 true positives and 20 false positives (62% PPV). The cost per patient diagnosed with SHD was $4,733 with AI-ECG alone but decreased to $3,182 with stepwise screening (33% cost savings). Screening for individual SHDs resulted in cost reduction from $18,724 to $6,315 (66% savings) for AS, $21,023 to $12,230 (42% savings) for CA, $9,883 to $6,175 (38% savings) for HCM, and $4,019 to $3,582 (11% savings) for LVD. Conclusions: Stepwise screening for SHD with AI-ECG followed by POCUS significantly reduces costs compared to AI-ECG alone. We also suggest a model for parallel screening for multiple SHDs, which is likely more cost-effective than screening for individual SHDs.