Abstract Aims Heart failure is prevalent; however, there is no cost-effective screening option. Against formal echocardiography, we assessed the diagnostic performance of focused cardiac ultrasound (FoCUS), performed by novice users guided and interpreted by artificial intelligence (AI) for the assessment of left ventricular ejection fraction (LVEF). Methods and results We prospectively enrolled 496 adults referred for diagnostic echocardiography. Novice operators (without clinical or imaging experience) underwent a 4-h imaging workshop, then performed FoCUS using a point-of-care device (Philips Lumify) utilizing real-time AI-image guidance (UltraSight). Images were assessed by AI-image interpretation software (Mayo Clinic), and two expert blinded echocardiologists. Median age was 67, 39% female, and body mass index range 17–56 kg/m2. Forty-one subjects (8.3%) exhibited moderate or greater LV dilatation and 28 (5.6%) had LVEF <40%. The median scan time was 4 min (IQR 3–5). Adequate views were achieved in 95.0% and 97.4% of subjects for AI interpretation and expert analysis, respectively. A two-step diagnostic screening process for low EF in which only abnormal AI reads or uninterpretable scans were reviewed by experts (15.1%) had a sensitivity 96.2%, specificity 95.4%, PPV 54.3%, and NPV 99.8%. A subsequent prospective validation study of 344 subjects demonstrated similar results (sensitivity 100%, specificity 99.4%). Conclusion In this early feasibility investigation, AI-guidance technology embedded on a handheld device, enabled novice users without clinical or imaging experience to acquire sufficient quality images to accurately assess LVEF with minimal training. The technology evaluated in this study may hold promise for AI-guidance and interpretation to facilitate low-cost screening for cardiac dysfunction.
Prognostic Value of Artificial Intelligence–Enabled Electrocardiography–Derived Diastolic Dysfunction Grading and Trajectory in Patients Undergoing Transcatheter Aortic Valve Replacement
Background Artificial intelligence (AI)–enabled electrocardiography has emerged as a tool for detecting cardiac dysfunction. The prognostic relevance of AI‐enabled electrocardiography–derived diastolic dysfunction (DD) in patients undergoing transcatheter aortic valve replacement had not been assessed. Methods We analyzed 3197 patients undergoing transcatheter aortic valve replacement for severe aortic stenosis between 2010 and 2023 with baseline 12‐lead ECGs processed by a validated AI model to classify diastolic function (grades 0–3). Multivariable Cox models and nested model comparisons assessed associations with all‐cause mortality, including a prespecified analysis in patients with indeterminate echocardiographic grading. Trajectories were defined by change in AI‐enabled electrocardiography DD grade (<2 versus ≥2) from baseline to 30‐day or 1‐year follow‐up. Results At baseline, 21% had grade 3, 57% had grade 2, 8% had grade 1, and 14% had grade 0 AI‐enabled electrocardiography DD. Higher grades were associated with adverse cardiac remodeling and comorbidities. Over a median follow‐up of 3.4 years, grade 3 AI‐enabled electrocardiography DD independently predicted mortality (hazard ratio [HR], 1.80 [95% CI, 1.47–2.20]; P <0.001). AI‐enabled electrocardiography DD improved prognostic discrimination beyond clinical and echocardiographic measures (ΔHarrell concordance statistic, 0.016; Δ χ 2 =57; P <0.001). Among 1259 patients with indeterminate echocardiographic grading, AI‐enabled electrocardiography added prognostic value (ΔHarrell concordance statistic, 0.02; Δ χ 2 =13; P =0.006). Worsening or persistently high‐risk trajectories were associated with increased mortality (HRs, 1.45–1.80; all P <0.05). Conclusions AI‐enabled electrocardiography–derived DD independently predicts mortality after transcatheter aortic valve replacement, adds value beyond echocardiographic grading, and enables dynamic risk stratification through longitudinal tracking.