Background Diastolic dysfunction is common in patients with aortic stenosis and may influence outcomes following surgical aortic valve replacement. We aimed to examine the association of preoperative artificial intelligence (AI)‐generated diastolic function grades with early and late outcomes following aortic valve replacement and how postoperative progression influence prognosis. Methods We identified 5503 patients undergoing aortic valve replacement between 2000 and 2023. Diastolic function was assessed using a validated deep‐learning AI model applied to 12‐lead ECGs done preoperatively and on postoperative follow‐up. Diastolic grades were classified by AI into Grades 1 to 3. Longitudinal trend analyses and multivariable regression models were used to assess study end points. Results Among 5503 patients (mean age 72.4±10.8 years; 39% female), higher AI ECG diastolic grades were associated with greater comorbidity burden, including diabetes, renal disease, and heart failure. AI ECG diastolic Grade 3 was independently associated with higher in‐hospital mortality (odds ratio, 2.5; P =0.007) and other complications. At 5‐year follow‐up, patients with Grade 3 showed the least improvement in diastolic function by both ECG and echocardiography. Grades 2 and 3 diastolic function at baseline were independently associated with increased late mortality (hazard ratio, 1.3 and 2.45, respectively; both P <0.001). Additionally, lack of improvement in AI ECG diastolic grade by 1 year was also independently associated with late mortality. Conclusions AI ECG–derived diastolic function grades strongly correlates with early complications and long‐term mortality and diastolic progression after aortic valve replacement. AI ECG provides a powerful, noninvasive tool for risk stratification and longitudinal monitoring of patients with aortic stenosis.
Artificial Intelligence–Enabled Acquisition and Interpretation for Screening Aortic Stenosis
Importance Timely identification of aortic stenosis (AS) is essential for appropriate clinical management, yet screening remains limited by dependence on comprehensive echocardiography and trained imaging personnel. Objective To develop and validate a deep learning algorithm for detection of moderate or greater AS and prospectively evaluate its performance using artificial intelligence (AI)–guided focused cardiac ultrasound (FoCUS) acquired by novice operators. Design, Setting, and Participants This diagnostic study included retrospective algorithm development and validation and prospective evaluation of AI-guided FoCUS across Mayo Clinic sites in the Midwest, Arizona, and Florida. The model was developed using 6753 patients and evaluated in internal validation (n = 852), internal test (n = 844), and validation (n = 1912) cohorts. Performance was assessed on FoCUS acquired by experienced sonographers (n = 602) and prospectively by novice operators (n = 1302). The retrospective model development and validation cohorts comprised studies performed from January 2005 through September 2022. Prospective study was conducted in 2 enrollment periods from June to August 2024 and from June to September 2025. Participants from both periods were combined to comprise the final prospective cohort. Exposure AI-guided FoCUS acquisition and automated deep learning–based assessment for detection of moderate or greater AS. Main Outcomes and Measures Detection of moderate or greater AS. Performance was assessed using area under the receiver operating characteristic curve (AUROC), sensitivity, specificity, and positive predictive value. Results The model demonstrated excellent discrimination in the internal test cohort (AUROC, 0.99; 95% CI, 0.98-1.00) and geographically distinct validation cohorts in Arizona (AUROC, 0.99; 95% CI, 0.97-1.00) and Florida (AUROC, 0.99; 95% CI, 0.96-1.00). Among FoCUS examinations acquired by experienced sonographers, sensitivity was 95% (95% CI, 82-99) and specificity was 97% (95% CI, 95-98). In the prospective novice-operator cohort, 1258 of 1302 examinations (96.6%) were suitable for automated analysis. Sensitivity was 93% (95% CI, 82-99) and specificity was 96% (95% CI, 95-97). Expert review of AI-positive and uninterpretable examinations increased the positive predictive value from 49.4% to 91.1%, with sensitivity of 85.4%. Conclusions and Relevance A deep learning algorithm accurately detected moderate or greater AS across validation cohorts in this study. In prospective evaluation, novice operators were able to acquire AI-guided FoCUS examinations that enabled accurate detection of moderate or greater AS. These findings support a scalable strategy that may expand access to AS detection in settings with limited echocardiography resources.
Predicting cardiac index from coronary angiogram videos: a novel application of 3D convolutional neural networks
Objective Data on cardiac index (CI) in patients undergoing coronary angiography (CAG) can enhance decision-making and improve clinical outcomes. However, this necessitates an additional invasive procedure, and therefore, it is frequently omitted. This study explores the novel application of convolutional neural networks (CNNs) to predict CI from routine CAGs. Methods and analysis Patients who underwent CAG and simultaneous right heart catheterisation at Mayo Clinic between 2002 and 2023 were included. A three-dimensional (3D)-CNN model (X3D architecture) was developed to predict binary CI categories (normal: CI≥2.2 vs abnormal: CI<2.2 L/min/m²) from CAG videos. CAGs were randomly split into training (70%), validation (15%) and test (15%) sets. All available videos from each study were entered into the model. The model’s performance was evaluated using the area under the curve (AUC), sensitivity, specificity and F1 score. Results A total of 15 297 CAG studies were considered. After applying a quality-check algorithm to exclude low-quality or irrelevant CAGs, 11 475 studies from 9103 patients were included. CI was abnormal in 25.2% of studies. The model achieved an AUC of 0.83 (95% CI 0.81 to 0.85), sensitivity of 0.72 (95% CI 0.68 to 0.77), specificity of 0.78 (95% CI 0.75 to 0.80) and F1 score of 0.62 (95% CI 0.58 to 0.65) on the test dataset. Limiting the input to 4, 3 or 2 prespecified CAG videos representing standard views did not significantly affect the model’s performance, supporting its applicability in varied clinical workflows. Conclusions This study demonstrates the feasibility of leveraging deep learning models to predict CI from CAG videos. The proposed 3D-CNN model shows promise as a tool for providing physicians with real-time data to aid decision-making during CAG procedures.
Echocardiography-Based, Artificial Intelligence-Enabled Electrocardiography (AI-ECG) for Diastolic Hemodynamics Phenotyping in Acute Heart Failure (AHF)
ABSTRACT Background Acute heart failure (AHF) exhibits marked heterogeneity in diastolic hemodynamics, yet comprehensive echocardiographic assessment of diastolic function (DF) and filling pressure (FP) is often infeasible. We evaluated whether artificial intelligence–enabled electrocardiography (AI-ECG) could provide scalable DF grading and FP estimation in hospitalized AHF patients. Methods We retrospectively studied adults hospitalized for AHF across Mayo Clinic sites (2013–2023) who received ≥1 dose of intravenous loop diuretic and had paired 12-lead ECG and TTE. The previously validated AI-ECG DF model was applied without retraining to generate four DF grades and a continuous FP probability. Clinical outcomes were all-cause mortality and heart failure rehospitalization. Associations with clinical severity markers and echocardiographic indices were examined. Kaplan–Meier survival analysis and adjusted multivariable Cox proportional hazards models were performed. Exploratory analyses examine the kinetics of change in FP probability and impact on mortality. Results Among 11,513 patients (median age 75 years, 39% female), AI-ECG DF grading was feasible in 100%, whereas echocardiographic DF was indeterminate in 44% of clinically eligible patients. In 2,582 patients with determinate echocardiographic DF, AI-ECG FP probability discriminated TTE Grade 2–3 dysfunction with AUC 0.85 (95% CI 0.83 – 0.86). Higher AI-ECG DF grades were associated with higher comorbidity burden, worse NYHA class, elevated NT-proBNP, higher MAGGIC scores, elevated PCWP, and more advanced structural remodeling. After multivariable adjustment, AI-ECG DF remained independently associated with mortality (hazard ratio [HR] 1.25, 95% CI 1.16–1.35 for Grade 2; HR 1.44, 95% CI 1.33–1.56 for Grade 3 versus Normal/Grade 1). Combining AI-ECG DF with MAGGIC scores yielded ordered risk gradients, with highest mortality in patients with both high MAGGIC and Grade 2–3 DF. Among patients with serial ECGs, improvement in FP probability was independently associated with lower mortality (HR 0.85, 95% CI 0.79–0.91), whereas worsening did not show a consistent adverse gradient beyond baseline DF. Conclusions In a large, geographically diverse AHF cohort, AI-ECG DF grading was universally feasible, correlated with established hemodynamic severity markers, and provided independent prognostic information beyond established risk factors, supporting its role as a pragmatic, scalable diastolic biomarker in AHF. CLINICAL PERSPECTIVE What Is New? In 11,513 hospitalized acute heart failure (HF) patients, artificial intelligence-enabled electrocardiography provided diastolic function grading in 100% of patients from a single 12-lead ECG without requiring additional clinical variables, compared with 56% feasibility for guideline-based echocardiography grading. AI-ECG diastolic function grades correlated with established marker of severity (NYHA functional class, NT-proBNP, MAGGIC risk scores, and pulmonary capillary wedge pressure) and remained independently associated with both mortality and HF rehospitalization after multivariable adjustment. Serial AI-ECG measurements identified post-discharge filling pressure trajectories, with improvement independently associated with 15% lower mortality, a first demonstration that longitudinal ECG assessment can track post-discharge hemodynamic recovery. What Are the Clinical Implications? AI-ECG transforms the universally obtained 12-lead ECG into an actionable hemodynamic biomarker that addresses the critical gap when echocardiographic diastolic function assessment is indeterminate or unavailable in acute HF patients. Despite markedly different hemodynamic severity and long-term outcomes across AI-ECG diastolic function grades, hospitalization length of stay did not differ, suggesting advanced diastolic dysfunction represents occult risk not easily recognized during routine acute care and highlighting the need for improved post-discharge risk stratification. The continuous filling pressure probability metric enables longitudinal monitoring of post-discharge hemodynamic status using serial routine ECGs, potentially identifying patients requiring intensified follow-up or specialist referral.
Prognostic Value of Artificial Intelligence–Enabled Electrocardiography–Derived Diastolic Dysfunction Grading and Trajectory in Patients Undergoing Transcatheter Aortic Valve Replacement
Background Artificial intelligence (AI)–enabled electrocardiography has emerged as a tool for detecting cardiac dysfunction. The prognostic relevance of AI‐enabled electrocardiography–derived diastolic dysfunction (DD) in patients undergoing transcatheter aortic valve replacement had not been assessed. Methods We analyzed 3197 patients undergoing transcatheter aortic valve replacement for severe aortic stenosis between 2010 and 2023 with baseline 12‐lead ECGs processed by a validated AI model to classify diastolic function (grades 0–3). Multivariable Cox models and nested model comparisons assessed associations with all‐cause mortality, including a prespecified analysis in patients with indeterminate echocardiographic grading. Trajectories were defined by change in AI‐enabled electrocardiography DD grade (<2 versus ≥2) from baseline to 30‐day or 1‐year follow‐up. Results At baseline, 21% had grade 3, 57% had grade 2, 8% had grade 1, and 14% had grade 0 AI‐enabled electrocardiography DD. Higher grades were associated with adverse cardiac remodeling and comorbidities. Over a median follow‐up of 3.4 years, grade 3 AI‐enabled electrocardiography DD independently predicted mortality (hazard ratio [HR], 1.80 [95% CI, 1.47–2.20]; P <0.001). AI‐enabled electrocardiography DD improved prognostic discrimination beyond clinical and echocardiographic measures (ΔHarrell concordance statistic, 0.016; Δ χ 2 =57; P <0.001). Among 1259 patients with indeterminate echocardiographic grading, AI‐enabled electrocardiography added prognostic value (ΔHarrell concordance statistic, 0.02; Δ χ 2 =13; P =0.006). Worsening or persistently high‐risk trajectories were associated with increased mortality (HRs, 1.45–1.80; all P <0.05). Conclusions AI‐enabled electrocardiography–derived DD independently predicts mortality after transcatheter aortic valve replacement, adds value beyond echocardiographic grading, and enables dynamic risk stratification through longitudinal tracking.
Deep learning for estimating right ventricular function from routine coronary angiography
Abstract Aims Coronary angiography might contain clinically relevant information, beyond its traditional role in delineating coronary artery disease. We sought to explore the role of deep learning (DL) in detecting right ventricular dysfunction from routinely acquired cine images during coronary angiography. Methods and results 3D-convolutional neural networks (CNN) were trained to identify right ventricle (RV) dysfunction from diagnostic angiography of the right coronary artery (RCA). The model’s input was two cine angiograms from LAO and RAO projections. The model’s output was normal vs. abnormal RV function. Ground truth on RV function was obtained from the nearest transthoracic echocardiogram to the coronary angiogram. Two analyses were performed to identify (i) any RV dysfunction (≥mild) and (ii) significant RV dysfunction (≥mild–moderate). A total of 10 336 coronary angiograms from 9849 patients (mean age 66, 36% women) were included. The cohort was split into training (70%), validation (15%), and testing (15%) sets. In the testing sets, the models attained an area under the ROC curve (AUC), sensitivity, and specificity of 0.82 (95% CI: 0.80–0.84), 0.75, and 0.74, for detecting any RV dysfunction, and 0.83 (95% CI: 0.80–0.86), 0.82, and 0.70 for detecting significant (≥mild–moderate) RV dysfunction. Combining an ECG-driven AI model with the angio-driven model improved the AUC values to 0.83 and 0.87 for detecting any or advanced RV dysfunction, respectively. Conclusion A novel deep learning algorithm yielded acceptable classification accuracy in detecting RV dysfunction from routine cine angiography of the RCA. The model’s performance improved further by adding ECG to its inputs.
Artificial Intelligence ECG Diastolic Dysfunction and Survival in Cardiac Intensive Care Unit Patients
Background Left ventricular diastolic dysfunction (LVDD) predicts mortality in patients in cardiac intensive care units. An artificial intelligence enhanced ECG (AIECG) algorithm can predict LVDD and mortality in general populations but has not been examined in cardiac intensive care units. Methods This historical cohort study included consecutive adults admitted to Mayo Clinic cardiac intensive care unit from 2007 to 2018 with an admission AIECG. The AIECG assigned the LVDD grade (0–3). Medial mitral E/e' ratio >15 on transthoracic echocardiogram (TTE) defined elevated filling pressures. In‐hospital and 1‐year mortality was evaluated, before and after multivariable adjustment. Results We included 11 868 patients (median age 69.5 years, 37.7% female); 48% had heart failure and 44% had acute coronary syndromes. AIECG LVDD grade was 0 (normal), 33%; 1, 7%; 2, 39%; and 3, 21%. In‐hospital and 1‐year mortality increased in each higher AIECG LVDD grade. After adjustment, each higher AIECG LVDD grade was associated with higher in‐hospital (adjusted odds ratio [OR], 1.22 [95% CI, 1.13–1.32]) and 1‐year mortality (adjusted hazard ratio [HR], 1.23 [95% CI, 1.19–1.29]); this persisted after adjustment for TTE measurements. Patients with grade 2 or 3 LVDD by AIECG and medial mitral E/e' ratio >15 by TTE had the highest in‐hospital (adjusted OR, 2.54 [95% CI, 1.69–3.88]) and 1‐year (adjusted HR, 2.03 [95% CI, 1.65–2.48]) mortality, whereas patients meeting either of these criteria had similar, elevated mortality. Conclusions The AIECG LVDD grade was strongly associated with in‐hospital and 1‐year mortality in patients in cardiac intensive care units, even after adjusting for clinical variables and TTE measurements. Patients with concordant AIECG and TTE for elevated filling pressures were at highest risk.
Artificial intelligence–derived electrocardiographic aging and risk of atrial fibrillation: a multi-national study
Abstract Background and Aims Artificial intelligence (AI) algorithms in 12-lead electrocardiogram (ECG) provides promising age prediction methods. This study investigated whether the discrepancy between ECG-derived AI-predicted age (AI-ECG age) and chronological age, termed electrocardiographic aging (ECG aging), is associated with atrial fibrillation (AF) risk. Methods An AI-ECG age prediction model was developed using a large-scale dataset (1 533 042 ECGs from 689 639 participants) and validated with six independent and multi-national datasets (737 133 ECGs from 330 794 participants). The AI-ECG age gap was calculated across two South Korean cohorts [mean (standard deviation) follow-up: 4.1 (4.3) years for 111 483 participants and 6.1 (3.8) years for 37 517 participants], one UK cohort [3.0 (1.6) years; 40 973 participants], and one US cohort [12.9 (8.6) years; 90 639 participants]. Participants were classified into two groups: normal group (age gap < 7 years) and ECG-aged group (age gap ≥ 7 years). The predictive capability of ECG aging for new- and early-onset AF risk was assessed. Results The mean AI-ECG ages were 51.9 (16.2), 47.4 (12.5), 68.4 (7.8), and 56.7 (14.6) years with age gaps of .0 (6.8), −.1 (6.0), 4.7 (8.7), and −1.4 (8.9) years in the two South Korean, UK, and US cohorts, respectively. In the ECG-aged group, increased risks of new-onset AF were observed with hazard ratios (95% confidence intervals) of 2.50 (2.24–2.78), 1.89 (1.46–2.43), 1.90 (1.55–2.33), and 1.76 (1.67–1.86) in the two South Korean, UK, and US cohorts, respectively. For early-onset AF, odds ratios were 2.89 (2.47–3.37), 1.94 (1.39–2.70), 1.58 (1.06–2.35), and 1.79 (1.62–1.97) in these cohorts compared with the normal group. Conclusions The AI-derived ECG aging was associated with the risk of new- and early-onset AF, suggesting its potential utility to identify individuals for AF prevention across diverse populations.
Abstract 4146270: Real-World Performance of the Artificial Intelligence-Enabled Electrocardiogram to Detect Increased Left Ventricular Filling Pressure to Predict Incidence of Heart Failure
Background: Our team recently developed an Artificial Intelligence model that enables the identification of increased left ventricular filling pressures using a single-lead electrocardiogram (AI-ECG) with excellent performance (AUC 0.91). However, its ability to predict incident heart failure (HF) in the community is yet to be evaluated. Hypothesis: We tested the hypothesis that the output from the AI-ECG will predict the long-term incidence of heart failure (HF) and HF with preserved ejection fraction (HFpEF), and would refine the HF predictive capabilities of the AHA Predicting Risk of Cardiovascular Disease EVENTs (PREVENT TM ) Equations. Methods: Leveraging the resources of the Rochester Epidemiology Project (REP) we analyzed data from patients who sought primary care in Olmsted County, MN, between 1997-2003 with passive follow-up until April 2024. We included those with a digital ECG at baseline and excluded those who were part of the original algorithm development or history of heart failure. The diagnosis of heart failure was ascertained by using ICD codes (ICD9-428,ICD10-I.50) and a word search for the terms related to heart failure. HFpEF was ascertained using the Ejection Fraction (EF) data closest to the heart failure diagnosis date, using EF more than 40% as the criterion. We tested the association between AI-ECG predicted probabilities and new-onset HF and HFpEF using Cox proportional hazard models. These models were also adjusted for cardiovascular risk factors and were stratified to evaluate the effect of the AI-ECG output on PREVENT TM -predicted HF at 10 years. Results: We included 20,276 subjects, mean age 55±14.03, 52% women, 92% non-Hispanic white. After 18.2±8.5 years of follow-up, 4,008 (19.76%) were diagnosed with HF and 3,812 (18.8%) HFpEF. Risks of HF and HFpEF significantly increased in patients with increased left ventricular filling pressures by AI-ECG, independent of risk factors, all p for trend <0.001, see Fig A-B , respectively. AI-ECG enhanced the prediction capabilities of the PREVENT TM score across all risk groups, see Fig-C. Conclusions: AI-ECG-Derived increased left ventricular filling pressure is associated with new-onset HF and HFpEF in the community and was associated with incidental heart failure at any PREVENT TM risk category. Those results suggest a potential role of AI ECG in predicting heart failure.
Secondary tricuspid regurgitation: incidence, types, and outcomes in atrial fibrillation vs. sinus rhythm
Abstract Background and Aims Incidence and types of secondary tricuspid regurgitation (TR) are not well defined in atrial fibrillation (AFib) and sinus rhythm (SR). Atrial secondary TR (A-STR) is associated with pre-existing AFib; however, close to 50% of patients with A-STR do not have AFib. The aim of this study was to assess incidence, types, and outcomes of ≥ moderate TR in AFib vs. SR. Methods Adults with and without new-onset AFib without structural heart disease or ≥ moderate TR at baseline were followed for the development of ≥ moderate TR. Tricuspid regurgitation types were pacemaker, left-sided valve disease, left ventricular (LV) dysfunction, pulmonary hypertension (PH), isolated ventricular, and A-STR. Results Among 1359 patients with AFib and 20 438 in SR, 109 and 378 patients developed ≥ moderate TR, respectively. The individual types of TR occurred more frequently in AFib related to the higher pacemaker implantation rates (1.12 vs. 0.19 per 100 person-years, P < .001), larger right atrial size (median 78 vs. 53 mL, P < .001), and higher pulmonary pressures (median 30 vs. 28 mmHg, P < .001). The most common TR types irrespective of rhythm were LV dysfunction-TR and A-STR. Among patients in SR, those with A-STR were older, predominantly women with more diastolic abnormalities and higher pulmonary pressures. All types of secondary TR were associated with all-cause mortality, highest in PH-TR and LV dysfunction-TR. Conclusions New-onset AFib vs. SR conferred a higher risk of the individual TR types related to sequelae of AFib and higher pacemaker implantation rates, although the distribution of TR types was similar. Secondary TR was universally associated with increased mortality.