Back to Authors

Fletcher, Joel G.

https://orcid.org/0000-0002-8941-5434

Mayo Clinic

Mayo Clinic

Citations 159

Adult Abdominal Photon-Counting CT Protocols: A Multiinstitutional Consensus of the Society of Abdominal Radiology Photon-Counting Detector CT Emerging Technology Commission
Anathakrishnan, Lakshmi, Marin, Daniele , Toia, Giuseppe V. , Borhani, Amir A. , Chung, Ryan , Morgan, Desiree E. , Dane, Bari , Schwartz, Fides R. , Leng, Shuai , Fletcher, Joel G.

American Journal of Roentgenology | October 8, 2025 | Volume: 225 | Issue: 6 | Pages: No page available

10.2214/ajr.25.33625 Get It

SAR Consensus Recommendations for Defining Small Bowel Crohn Disease Strictures at CT and MR Enterography
Dillman, Jonathan R. , Fidler, Jeff L. , Anupindi, Sudha A. , Fulmer, Clifton G. , Gordon, Ilyssa O. , Bruining, David H. , Deepak, Parakkal , Abualruz, Abdul Rahman , Al-Hawary, Mahmoud M. , Altinmakas, Emre , Guglielmo, Flavius F. , Jaffe, Tracy A. , Rieder, Florian , Baker, Mark E. , Dane, Bari , Dillman, Jonathan R , Fidler, Jeff L. , Anupindi, Sudha A , Fulmer, Clifton , Gordon, Ilyssa O , Bruining, David Henry , Deepak, Parakkal , Abualruz, Abdul-Rahman , Al-Hawary, Mahmoud , Guglielmo, Flavius F , Jaffe, Tracy , Bettenworth, Dominik , Rieder, Florian , Fletcher, Joel G , Baker, Mark E , Rimola, Jordi , Fletcher, Joel G.

Radiology | July 15, 2025 | Volume: 316 | Issue: 1 | Pages: No page available

10.1148/radiol.243123 Get It

This consensus by the Society of Abdominal Radiology Inflammatory Bowel Disease Disease Focused Panel provides an updated imaging-based definition of small bowel Crohn disease stricture for CT and MR enterography.
Mucinous Appendiceal Neoplasms and Pseudomyxoma Peritonei: Imaging Features and Current Therapies
Jorgenson, Laura C. , Wang, Sherry S. , Navin, Patrick J. , Favazza, Christopher , Venkatesh, Sudhakar K. , Fidler, Jeff L. , Fletcher, Joel G. , Ehman, Eric C. , Sheedy, Shannon P. , Navin, Patrick , Venkatesh, Sudhakar K , Fidler, Jeff L. , Fletcher, Joel G , Grotz, Travis E. , Graham, Rondell P.

RadioGraphics | May 29, 2025 | Volume: 45 | Issue: 6 | Pages: No page available

10.1148/rg.240131 Get It

Radiologists are integral members of the interdisciplinary team for patients with mucinous appendiceal neoplasms and can directly affect care by suggesting the diagnosis of pseudomyxoma peritonei, optimizing imaging protocols for evaluating peritoneal implants, and reporting the primary tumor and spilled tumor cells thoroughly.
Quantitative CT imaging: where are we, and what is missing?
Treb, Kevin , Sadaney, Ahmed O El , Ferrero, Andrea , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Rajendran, Kishore , Treb, Kevin J, El Sadaney, Ahmed O , Leng, Shuai , Yu, Lifeng , Rajiah, Prabhakar Shantha, McCollough, Cynthia H , Rajendran, Kishore , Treb, Kevin , Baffour, Francis , Rajiah, Prabhakar , Fletcher, Joel G.

British Journal of Radiology | April 7, 2025 | Volume: 98 | Issue: 1175 | Pages: 1834-1842

10.1093/bjr/tqaf075 Get It

Abstract Quantitative computed tomography (CT) enables the measurement of biophysical processes characterized by morphology, composition, flow, and/or motion to aid in clinical diagnosis and intervention. Since its initial application for determining bone mineral density for skeletal fragility assessment, quantitative CT has continued to evolve alongside CT’s technological advancements. A key challenge facing quantitative CT is the lack of standardization pertinent to image acquisition, reconstruction, and image analysis. With the introduction of spectral CT involving dual-energy approaches and photon-counting detectors (PCD), we are now able to obtain detailed information regarding mass densities of endogenous and exogeneous materials. Furthermore, energy-resolved CT yields spectral image types (eg, virtual monoenergetic image) that are, in principle, independent of tube potential and patient size. This paves the way for workflow standardization and helps improve the consistency and reproducibility of CT-derived measurements. In this article, we review clinical applications of quantitative CT, discuss key challenges associated with quantitative CT and its adoption into routine practice, and outline the unique benefits ushered by new CT technologies such as PCD-CT towards improving quantitative imaging.
Physics‐informed model‐based generative neural network for synthesizing scanner‐ and algorithm‐specific low‐dose CT exams
Yu, Lifeng , Hsieh, Scott S. , Gong, Hao , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Medical Physics | February 13, 2025 | Volume: 52 | Issue: 6 | Pages: 3940-3958

10.1002/mp.17680 Get It

Abstract Background Accurate low‐dose CT simulation is required to efficiently assess reconstruction and dose reduction techniques. Projection domain noise insertion requires proprietary information from manufacturers. Analytic image domain noise insertion methods are successful for linear reconstruction algorithms, however extending them to non‐linear algorithms remains challenging. Emerging, deep‐learning‐based image domain noise insertion methods have potential, but few approaches have explicitly incorporated physics information and a texture‐synthesis model to guide the generation of locally and globally correlated noise texture. Purpose We proposed a p hysics‐informed model‐based gener a tive neura l network for simulating scann e r‐ and algori t hm‐specific low‐dose C T e xams (PALETTE). It is expected to provide an alternative to projection domain noise insertion methods in the absence of manufacturers’ proprietary information and tools. Methods PALETTE integrated a physics‐based noise prior generation process, a Noise2Noisier sub‐network, and a noise texture synthesis sub‐network. The Noise2Noisier sub‐network provided a bias prior, which, combined with the noise prior, served as the inputs to noise texture synthesis sub‐network. Explicit regularizations in spatial and frequency domains were developed to account for noise spatial correlation and frequency characteristics. For proof‐of‐concept, PALETTE was trained and validated for a commercial iterative reconstruction algorithm (SAFIRE, Siemens Healthineers), using the paired routine and 25% dose images from CT phantoms (lateral size 30–40 cm; three training and four testing phantoms) and open‐access patient cases (10 training and 20 testing cases). In phantom validation, noise power spectra (NPS) were compared in water background and tissue‐mimicking inserts, using peak frequency and mean‐absolute‐error (MAE). In patient case evaluation, visual inspection and quantitative assessment were conducted on axial, coronal, and sagittal planes. Local and global noise texture were visually inspected in low‐dose CT images and the difference images between routine and low dose. Noise levels in liver and fat were measured. Local and global 2D Fourier magnitude spectra of the difference images and the corresponding radial mean profiles were used to assess similarity in noise frequency components within tissues and entire field‐of‐view, using spectral correlation mapper (SCM) and spectral angle mapper (SAM). Several baseline neural network models (e.g., GAN) were included in the evaluation. Statistical significance was tested using a t ‐test for related samples. Results PALETTE‐derived NPS showed accurate noise peak frequency (PALETTE/reference: water 1.40/1.40 lp/cm; inserts 1.7/1.7lp/cm) and small MAE (≤0.65 HU 2 cm 2 ). PALETTE created anatomy‐dependent noise texture, showing realistic local and global granularity and streaks. No statistically significant difference was observed in noise levels ( p > 0.05). Noise range was comparable across 3D image volume (PALETTE / reference):liver – [18.0, 53.4] / [19.3, 50.0] HU; fat – [11.7, 42.4] / [12.1, 41.3] HU. Percent absolute difference of local noise was small (mean ± standard deviation): liver 4.1%±3.1%, fat 4.6%±3.1%. Noise frequency distribution was close to the reference (mean per case): SCM ≥ 0.92, SAM ≤ 0.22. Additionally, PALETTE outperformed all baseline models in visual inspection and quantitative comparison. Conclusion PALETTE can provide high‐quality image domain noise insertion for simulating accurate low‐dose CT images created with a commercial non‐linear reconstruction algorithm.
Circulating and Magnetic Resonance Imaging Biomarkers of Intestinal Fibrosis in Small Bowel Crohn’s Disease
Dillman, Jonathan R. , Tkach, Jean A. , Bruining, David H. , Lu, Aiming , Kugathasan, Subra , Knight‐Scott, Jack, Adler, Jeremy, Minar, Phillip , Bonkowski, Erin , Jurrell, Holden, Swanson, Scott D. , Fei, Lin , Qian, Lucia, Towbin, Alexander J. , Kocaoğlu, Murat , Anton, Christopher G. , Imbus, Rebecca, Denson, Lee A. , Kugathasan, Subra , Minar, Phillip , Dillman, Jonathan R , Fletcher, Joel G. , Alazraki, Adina , Stidham, Ryan W , Adler, Jeremy, Trapnell, Bruce C. , Lopez‐Nunez, Oscar , Collins, Margaret H. , Dudley, Jonathan A.

Inflammatory Bowel Diseases | January 24, 2025 | Volume: 31 | Issue: 5 | Pages: 1380-1391

10.1093/ibd/izae319 Get It

Abstract Background We previously identified circulating and MRI biomarkers associated with the surgical management of Crohn’s disease (CD). Here we tested associations between these biomarkers and ileal resection inflammation and collagen content. Methods Fifty CD patients undergoing ileal resection were prospectively enrolled at 4 centers. Circulating CD64, extracellular matrix protein 1 (ECM1), GM-CSF autoantibodies (GM-CSF Ab), and fecal calprotectin were measured by ELISA. Ileal 3-dimensional magnetization transfer ratio (3D MTR), modified Look-Locker inversion recovery (MOLLI) T1 relaxation, diffusion-weighted intravoxel incoherent motion (IVIM), and the simplified magnetic resonance index of activity (sMaRIA) were measured by MRI. Ileal resection specimen acute inflammation was graded, and collagen content was measured quantitatively using second harmonic imaging microscopy. Associations between biomarkers and ileal collagen content were tested. Results Median (interquartile range [IQR]) age was 19.5 (16-33) years. We observed an inverse relationship between ileal acute inflammation and collagen content (r = −0.39 [95% confidence interval {CI}: −0.61, −0.10], P = .008). Most patients (33 [66%]) received biologics, with no variation in collagen content with treatment exposures. In the univariate analysis, CD64, GM-CSF Ab, fecal calprotectin, and sMaRIA were positively associated with acute inflammation and negatively associated with collagen content (P < .1). The multivariable model for ileal collagen content (R2 = 0.31 [95% CI: 0.11, 0.52]) included log CD64 (β = −.27; P = .19), log ECM1 (β = .47; P = .06), log GM-CSF Ab (β = −.15; P = .01), IVIM f (β = .29, P = .10), and IVIM D* (β = 1.69, P = .13). Conclusions Clinically available and exploratory circulating and MRI biomarkers are associated with the degree of inflammation versus fibrosis in CD ileal resections. With further validation, these biomarkers may be used to guide medical and surgical decision-making for refractory CD.
P0238 Reliability of magnetic resonance imaging indices for evaluating perianal fistulizing disease activity in paediatric Crohn’s disease
Karpewycz, John , Watson, Tom A. , Schneider, R, Alsabban, Zehour , Cytter-Kuint, Ruth, Lewindon, Peter , Gee, Michael S. , Hyams, J S, Allmen, Daniel von, Overstraeten, Anthony de Buck van , Shackelton, L, Rémillard, J, Ashton, H A, Taylor, Stuart A. , Church, Peter, Feagan, B, Griffiths, A, Crowley, Eileen , Rimola, Jordi , Schneider, R, Ma, Christopher , Zou, Guangyong , Gee, Michael Stanley , Rosen, Michael J. , Ashton, H, Dillman, Jonathan R , Fletcher, Joel G. , Church, Peter , Jairath, Vipul , Greer, Mary‐Louise C.

Journal of Crohn's and Colitis | January 22, 2025 | Volume: 19 | Issue: Supplement_1 | Pages: i660-i661

10.1093/ecco-jcc/jjae190.0412 Get It

Abstract Background Progress in clinical trials and drug development for paediatric perianal fistulising CD (pfCD) depends upon accurate, reproducible imaging to assess disease activity and measure treatment response. We evaluated the inter- and intra-rater reliability of existing radiologic disease activity indices and anatomical classification systems previously identified as appropriate for assessment of paediatric pfCD.1 Methods A retrospective cohort (N=50) of magnetic resonance imaging (MRI) exams representing a full spectrum of paediatric (<18 years) perianal CD severity was selected by a single expert paediatric radiologist. Methods described by Zou2 were used to estimate sample size. Three separate radiologists (2 paediatric) blinded to clinical information assessed pfCD in the exams using the Magnetic Resonance Novel Index for Fistula Imaging in CD (MAGNIFI-CD), Van Assche Index (VAI), modified VAI (mVAI), Paediatric MRI based Perianal Crohn’s disease (PEMPAC) index, a visual analogue scale (VAS) of overall pfCD disease severity (range, 0-100 mm), as well as with the Park’s and St. James University Hospital anatomic classification systems. Two radiologists read all exams twice, separated by 2 weeks, and 1 radiologist read the exams once (250 total reads). Intra- and inter-rater reliability was evaluated using intraclass correlation coefficients (ICC; equivalent to weighted kappa). Precision of the ICC estimates was quantified with 95% confidence intervals (CIs) obtained using clustered bootstrapping. Degree of reliability was interpreted with benchmarks proposed by Landis and Koch3. Results Median age of children was 13.5 years (IQR 11.4-16.1), and 64% were male. Median Paediatric Crohn’s Disease Activity Index score at time of imaging was 17.5 (IQR 10-32.5). Substantial (ICC>0.61) inter-rater reliability was observed for MAGNIFI-CD, VAI, and mVAI (Table 1), with the highest ICCs observed for the mVAI (0.72 [0.6 to 0.79]). Moderate (ICC>0.41) inter-rater reliability was observed for PEMPAC, St. James University Hospital classification, and the VAS, and fair (ICC>0.21) inter-rater reliability was observed for Parks classification. Intra-rater reliability was nearly perfect (ICC>0.81) for the VAS, and substantial for all indices except for Parks classification, which had moderate (0.60 [0.44 to 0.75]) intra-rater reliability (Table 1). Conclusion Most existing multi-item MRI-based disease activity indices and the St. James Hospital classification were reliable for the assessment of paediatric pfCD in our cohort. Our preliminary results suggest that the disease activity indices may have utility to measure treatment effect in paediatric pfCD clinical trials. References 1.Crowley E, Ma C, Guizzetti L, Zou G, Lewindon PJ, Gee MS, et al. Recommendations for Standardizing MRI-based Evaluation of Perianal Fistulizing Disease Activity in Pediatric Crohn's Disease Clinical Trials. Inflamm Bowel Dis. 2024;30(3):357-69. 2.Zou GY. Sample size formulas for estimating intraclass correlation coefficients with precision and assurance. Statistics in Medicine. 2012;31(29):3972-398 3.Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159-74.
Opportunistic Bone Mineral Density Measurement Using Photon-Counting Detector CT Spectral Localizer Images: A Prospective Study
Sadaney, Ahmed O El , Ferrero, Andrea , Jasper, Sören , Mazza, Gina L. , Shanblatt, Elisabeth R. , Nowak, Tristan , El Sadaney, Ahmed O , Mazza, Gina L , Rajendran, Kishore , Broski, Stephen M. , Fletcher, Joel G. , McCollough, Cynthia H. , Baffour, Francis

American Journal of Roentgenology | October 30, 2024 | Volume: 224 | Issue: 1 | Pages: No page available

10.2214/ajr.24.31909 Get It

Feasibility of thin-slice, low noise images created using multi-kernel synthesis to replace multiple image series in head CT
Diehn, Felix E. , Nagelschneider, Alex A. , Passe, Theodore J. , Nelson, Brandon , Cardona, Daniel Gomez , Huber, Nathan R. , Missert, Andrew D, Yu, Lifeng , Johnson, Matthew P. , Holmes, David R. , Lee, Yong S. , Thorne, Jamison E. , Diehn, Felix E , DeLone, David R. , Nelson, Brandon J, Gomez Cardona, Daniel G , Thorne, Jamison E , Fletcher, Joel G , Inoue, Akitoshi , Missert, Andrew D, Yu, Lifeng , McCollough, Cynthia H. , Fletcher, Joel G.

Acta Radiologica | October 17, 2024 | Volume: 65 | Issue: 11 | Pages: 1411-1421

10.1177/02841851241280365 Get It

Background SynthesiZed Improved Resolution and Concurrent nOise reductioN (ZIRCON) is a multi-kernel synthesis method that creates a single series of thin-slice computed tomography (CT) images displaying low noise and high spatial resolution, increasing reader efficiency and minimizing partial volume averaging. Purpose To compare the diagnostic performance of a single set of ZIRCON images to two routine clinical image series using conventional CT head and bone reconstruction kernels for diagnosing intracranial findings and fractures in patients with trauma or suspected acute neurologic deficit. Material and Methods In total, 50 patients underwent clinically indicated head CT in the ER (15 normal, 35 abnormal cases). A non-reader neuroradiologist established the reference standard. Three neuroradiologists reviewed two routine clinical series (head and bone kernels) and a single ZIRCON series, detecting intracranial findings or fractures and rating confidence (0–100). Sensitivity, specificity, and jackknife free-response receiver operating characteristic (JAFROC) figure of merit (FOM) were compared (limit of non-inferiority: −0.10). Results ZIRCON and conventional images demonstrated comparable performance for fractures (sensitivity: 51.5% vs. 54.5%; specificity: 40.2% vs. 34.2%) and intracranial findings (sensitivity: 88.2% vs. 91.4%; specificity: 77.2% vs. 73.7%).The estimated difference of JAFROC FOM demonstrated ZIRCON non-inferiority for acute pathologies overall (0.003 [95% CI=−0.051–0.057]) and fractures (0.048 [95% CI=−0.050–0.145]) but not for intracranial findings alone (−0.024 [95% CI=−0.100–0.052]). Conclusion Thin-slice, low noise, and high spatial resolution images can be created to display intracranial findings and fractures replacing multiple images series in head CT with similar performance. Future studies in more patients and further algorithmic development are warranted.
Performance evaluation of single‐ and dual‐contrast spectral imaging on a photon‐counting‐detector CT
Ren, Liqiang , Zhou, Zhongxing , Ahmed, Zaki , Yu, Lifeng , Rajendran, Kishore , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | September 5, 2024 | Volume: 51 | Issue: 11 | Pages: 8034-8046

10.1002/mp.17367 Get It

AbstractBackgroundThe first commercially available photon‐counting‐detector CT (PCD‐CT) has been introduced for clinical use. However, its spectral performance on single‐ and dual‐contrast imaging tasks has not been comprehensively assessed.PurposeTo evaluate the spectral imaging performance of a clinical PCD‐CT system for single‐contrast material [iodine (I) or gadolinium (Gd)] and dual‐contrast materials (I and Gd) in comparison with a dual‐source dual‐energy CT (DS‐DECT).MethodsIodine (5, 10, and 15 mg/mL) and gadolinium (3.3, 6.6, and 9.9 mg/mL) samples, and their mixtures (I/Gd: 5/3.3 and 10/6.6 mg/mL) were prepared and placed in two torso‐shaped water phantoms (lateral dimensions: 30 and 40 cm). These phantoms were scanned on a PCD‐CT (NAEOTOM Alpha, Siemens) at 90, 120, and 140 kV. The same phantoms were scanned on a DS‐DECT (SOMATOM Force, Siemens) with 70/Sn150, 80/Sn150, 90/Sn150, and 100/Sn150 kV. The radiation dose levels were matched [volume CT dose index (CTDIvol): 10 mGy for the 30 cm phantom and 20 mGy for the 40 cm phantom] across all tube voltage settings and between scanners. Two‐material decomposition (I/water or Gd/water) was performed on iodine or gadolinium samples, and three‐material decomposition (I/Gd/water) on both individual samples and mixtures. On each decomposed image, mean mass concentration (± standard deviation) was measured in circular region‐of‐interests placed on the contrast samples. Root‐mean‐square‐error (RMSE) values of iodine and gadolinium concentrations were reported based on the measurements across all contrast samples and repeated on 10 consecutive slices.ResultsFor all material decomposition tasks on the DS‐DECT, the kV pairs with greater spectral separation (70/Sn150 kV and 80/Sn150 kV) yielded lower RMSE values than other DS‐DECT and PCD‐CT alternatives. Specifically, for the optimal 70/Sn150 kV, RMSE values were 1.2 ± 0.1 mg/mL (I) for I/water material decomposition, 1.0 ± 0.1 mg/mL (Gd) for Gd/water material decomposition, and 4.5 ± 0.2 mg/mL (I) and 3.7 ± 0.2 mg/mL (Gd), respectively, for I/Gd/water material decomposition. On the PCD‐CT, the optimal tube voltages were 120 or 140 kV for I/water decomposition with RMSE values of 2.0 ± 0.1 mg/mL (I). For Gd/water decomposition on PCD‐CT, the optimal tube voltage was 140 kV with gadolinium RMSE values of 1.5 ± 0.1 mg/mL (Gd), with the 90 kV setting on PCD‐CT generating higher RMSE values for gadolinium concentration compared to all DS‐DECT and PCD‐CT alternatives. For three material decomposition, both imaging modalities demonstrated substantially higher RMSE values for iodine and gadolinium, with 90 kV being the optimal tube potential for Gd/I quantitation on PCD‐CT [5.4 ± 0.3 mg/mL (I) and 3.9 ± 0.2 mg/mL (Gd)], and DS‐DECT at 100/Sn150 kV having larger RMSE values for both materials compared to the alternatives for either modality.ConclusionOptimal tube voltage for material decomposition on the clinical PCD‐CT is task‐dependent but inferior to DS‐DECT using 70/Sn150 kV or 80/Sn150 kV in two‐material decomposition for single‐contrast imaging (iodine/water or gadolinium/water). Three material decomposition (iodine/gadolinium/water) in dual‐contrast imaging yields substantially higher RMSE for both imaging platforms.