AbstractBackgroundThe fasting proinsulin to insulin ratio is elevated in people with type 2 diabetes and has been suggested as a marker of β‐cell health. However, its utility in discriminating between individuals with varying degrees of β‐cell dysfunction is unclear. Proinsulin has a very different half‐life to insulin and unlike insulin does not undergo hepatic extraction prior to reaching the systemic circulation. Given these limitations, we sought to examine the relationship between fasting and postprandial concentrations of β‐cell polypeptides (proinsulin, insulin and C‐peptide) in people with normal and impaired glucose tolerance in differing metabolic environments.DesignSubjects were studied on two occasions in random order while undergoing an oral challenge. During one study day, free fatty acids were elevated (to induce insulin resistance) by infusion of Intralipid with heparin. Proinsulin to insulin and proinsulin to C‐peptide ratios were calculated for the 0‐, 30‐, 60‐ and 240‐minute time points. Insulin action (Si) and β‐cell responsivity (Φ) indices were calculated using the oral minimal model.ResultsThe fasting proinsulin to c‐peptide or fasting proinsulin to insulin ratios did not differ between groups and did not predict subsequent β‐cell responsivity to glucose during the glycerol or Intralipid study days in either group.ConclusionsAmong nondiabetic individuals, the fasting proinsulin to insulin ratio is not a useful marker of β‐cell function.
Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial
Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Hyperglycemia But Not Hyperinsulinemia Is Favorable for Exercise in Type 1 Diabetes: A Pilot Study
OBJECTIVE To distinguish the effects of hyperglycemia and hyperinsulinemia on exercise-induced increases in Rd and endogenous glucose production (EGP) in type 1 diabetes. RESEARCH DESIGN AND METHODS We studied six participants without diabetes and six participants with type 1 diabetes on three visits in random order for the following: euglycemia, low insulin (EuLoI); euglycemia, high insulin (EuHiI); and hyperglycemia, low insulin (HyLoI). Glucose fluxes were measured using [6,6-2H2] glucose before, during, and after 60 min of exercise. RESULTS Rd increased (P < 0.01) with exercise within groups, while peak Rd during exercise was lower (P < 0.01) in participants with type 1 diabetes than participants without diabetes during all visits. In type 1 diabetes participants, EGP increased (P < 0.001) with exercise during EuLoI and HyLoI but not during EuHiI. This demonstrates that hyperinsulinemia, but not hyperglycemia, blunts the compensatory exercise-induced increase in EGP in type 1 diabetes. CONCLUSIONS The data from this pilot study indicate that 1) exercise-induced compensatory increase in EGP was inhibited in participants with type 1 diabetes with hyperinsulinemia but not with hyperglycemia; 2) in contrast, in participants without diabetes, exercise-induced increase in EGP was inhibited only during combined hyperinsulinemia and hyperglycemia. Taken together, these results suggest that low insulin coupled with euglycemia or modest hyperglycemia appear to be the most favorable milieu for type 1 diabetes during exercise.
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P < 0.001). Time >180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P < 0.001) while time <54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
Diabetes-associated genetic variation in TCF7L2 alters pulsatile insulin secretion in humans
BACKGROUND Metabolic disorders such as type 2 diabetes have been associated with a decrease in insulin pulse frequency and amplitude. We hypothesized that the T allele at rs7903146 in TCF7L2, previously associated with β cell dysfunction, would be associated with changes in these insulin pulse characteristics. METHODS Twenty-nine nondiabetic subjects (age 46 ± 2, BMI 28 ± 1 kg/m 2 ) participated in this study. Of these, 16 were homozygous for the C allele at rs7903146 and 13 were homozygous for the T allele. Deconvolution of peripheral C-peptide concentrations allowed the reconstruction of portal insulin secretion over time. These data were used for subsequent analyses. Pulse orderliness was assessed by approximate entropy (ApEn), and the dispersion of insulin pulses was measured by a frequency dispersion index (FDI) after a Fast Fourier Transform (FFT) of individual insulin secretion rates. RESULTS During fasting conditions, the CC genotype group exhibited decreased pulse disorderliness compared with the TT genotype group (1.10 ± 0.03 vs. 1.19 ± 0.04, P = 0.03). FDI decreased in response to hyperglycemia in the CC genotype group, perhaps reflecting less entrainment of insulin secretion during fasting. CONCLUSION Diabetes-associated variation in TCF7L2 is associated with decreased orderliness and pulse dispersion, unchanged by hyperglycemia. Quantification of ApEn and FDI could represent novel markers of β cell health. FUNDING This work was funded by US NIH (DK78646, DK116231), University of Padova research grant CPDA145405, and Mayo Clinic General Clinical Research Center (UL1 TR000135).
A novel natural tracer method to measure complex carbohydrate metabolism
While the triple tracer isotope dilution method has enabled accurate estimation of carbohydrate turnover after a mixed meal, use of the simple carbohydrate glucose as the carbohydrate source limits its translational applicability to everyday meals that typically contain complex carbohydrates. Hence, utilizing the natural enrichment of [13C]polysaccharide in commercially available grains, we devised a novel tracer method to measure postprandial complex carbohydrate turnover and indices of insulin action and β-cell function and compared the parameters to those obtained after a simple carbohydrate containing mixed meal. We studied healthy volunteers after either rice ( n = 8) or sorghum ( n = 8) and glucose ( n = 16) containing mixed meals and modified the triple tracer technique to calculate carbohydrate turnover. All meals were matched for calories and macronutrient composition. Rates of meal glucose appearance (2,658 ± 736 vs. 4,487 ± 909 μM·kg−1·2 h−1), endogenous glucose production (−835 ± 283 vs. −1,123 ± 323 μM·kg−1·2 h−1) and glucose disappearance (1,829 ± 807 vs. 3,606 ± 839 μM·kg−1·2 h−1) differed ( P < 0.01) between complex and simple carbohydrate containing meals, respectively. Interestingly, there were significant increase in indices of insulin sensitivity (32.5 ± 3.5 vs. 25.6 ± 3.2 10−5(dl·kg−1·min−2)/pM, P = 0.006) and β-cell responsivity (disposition index: 1,817 ± 234 vs. 1,236 ± 159 10−14(dl·kg−1·min−2)/pM, P < 0.005) with complex than simple carbohydrate meals. We present a novel triple tracer approach to estimate postprandial turnover of complex carbohydrate containing mixed meals. We also report higher insulin sensitivity and β-cell responsivity with complex than with simple carbohydrates in mixed meals of identical calorie and macronutrient compositions in healthy adults.
Letter to the Editor: “Defects in GLP-1 Response to an Oral Challenge Do Not Play a Significant Role in the Pathogenesis of Prediabetes”
The characteristics of pulsatile insulin secretion are important determinants of type 2 diabetes pathophysiology, but they are understudied due to the difficulties in measuring pulsatile insulin secretion noninvasively. Deconvolution of either peripheral C-peptide or insulin concentrations offers an appealing alternative to hepatic vein catheterization. However, to do so, there are a series of methodological challenges to overcome. C-peptide has a relatively long half-life and accumulates in the circulation. On the other hand, peripheral insulin concentrations reflect relatively fast clearance and hepatic extraction as it leaves the portal circulation to enter the systemic circulation. We propose a method based on nonparametric stochastic deconvolution of C-peptide concentrations, using individually determined C-peptide kinetics, to overcome these limitations. The use of C-peptide (instead of insulin) concentrations allows estimation of portal (and not post-hepatic) insulin pulses, whereas nonparametric stochastic deconvolution allows evaluation of pulsatile signals without any a priori assumptions of pulse shape and occurrence. The only assumption required is the degree of smoothness of the (unknown) secretion rate. We tested this method first on simulated data and then on 29 nondiabetic subjects studied during euglycemia and hyperglycemia and compared our estimates with the profiles obtained from hepatic vein insulin concentrations. This method produced satisfactory results both in the ability to fit the data and in providing reliable estimates of pulsatile secretion, in agreement with hepatic vein measurements. In conclusion, the proposed method enables reliable and noninvasive measurement of pulsatile insulin secretion. Future studies will be needed to validate this method in people with type 2 diabetes.
The International Diabetes Closed-Loop Study: Testing Artificial Pancreas Component Interoperability