Back to Authors

Knight, Bradley P

0000-0002-2129-0401

Mayo Clinic

Division of Cardiology, Internal Medicine, Northwestern University Feinberg School of Medicine, Chicago, Ill.

Citations 23

Process mapping strategies to prevent subcutaneous implantable cardioverter‐defibrillator infections
Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Knight, Bradley P. , El-Chami, Mikhael F , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , Weiss, Raul , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Hansen, Linda K. , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | June 4, 2022 | Volume: 33 | Issue: 7 | Pages: 1628-1635

10.1111/jce.15566 Get It

AbstractBackgroundInfection remains a major complication of cardiac implantable electronic devices and can lead to significant morbidity and mortality. Implantable devices that avoid transvenous leads, such as the subcutaneous implantable cardioverter‐defibrillator (S‐ICD), can reduce the risk of serious infection‐related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S‐ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S‐ICD infections. Therefore, an expert panel was convened to develop a consensus on these topics.MethodsAn expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S‐ICD infections. Two face‐to‐face meetings of high‐volume S‐ICD implanters and an infectious diseases specialist, with expertise in cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre‐, peri‐, and postimplant to reduce S‐ICD infection risk.ResultsExpert panel consensus on recommended steps for patient preparation, S‐ICD implantation, and postoperative management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology for S‐ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S‐ICD infection.
The development of the extravascular defibrillator with substernal lead placement: A new Frontier for device‐based treatment of sudden cardiac arrest
Thompson, Amy , Atwater, Brett D. , Boersma, Lucas V.A. , Crozier, Ian , Engel, Gregory , Friedman, Paul A. , Gimbel, John , Knight, Bradley P. , Manlucu, Jaimie , Murgatroyd, Francis , O’Donnell, David , Kuschyk, Juergen , DeGroot, Paul, Thompson, Amy E , Friedman, Paul A , Knight, Bradley P , Boersma, Lucas , Crozier, Ian , Engel, Gregory

Journal of Cardiovascular Electrophysiology | April 28, 2022 | Volume: 33 | Issue: 6 | Pages: 1085-1095

10.1111/jce.15511 Get It

AbstractIntroductionThe extravascular implantable cardioverter‐defibrillator (EV ICD) system with substernal lead placement is a novel nontransvenous alternative to current commercially available ICD systems. The EV ICD provides defibrillation and pacing therapies without the potential long‐term complications of endovascular lead placement but requires a new procedure for implantation with a safety profile under evaluation.MethodsThis paper summarizes the development of the EV ICD, including the preclinical and clinical evaluations that have contributed to the system and procedural refinements to date.ResultsExtensive preclinical research evaluations and four human clinical studies with >140 combined acute and chronic implants have enabled the development and refinement of the EV ICD system, currently in worldwide pivotal study.ConclusionThe EV ICD may represent a clinically valuable solution in protecting patients from sudden cardiac death while avoiding the long‐term consequences of transvenous hardware. The EV ICD offers advantages over transvenous and subcutaneous systems by avoiding placement in the heart and vasculature; relative to subcutaneous systems, EV ICD requires less energy for defibrillation, enabling a smaller device, and provides pacing features such as antitachycardia and asystole pacing in a single system.
Device‐related infection associated with increased mortality risk in de novo transvenous implantable cardioverter‐defibrillator medicare patients
Liu, Yiyan , Griffiths, Robert I. , Knight, Bradley P. , Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline M., El-Chami, Mikhael F , Weiss, Raul , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | January 23, 2022 | Volume: 33 | Issue: 4 | Pages: 725-730

10.1111/jce.15385 Get It

AbstractIntroductionTransvenous implantable cardioverter‐defibrillators (TV‐ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV‐ICD infection in a large Medicare population with de novo TV‐ICD implants.MethodsA survival analysis was conducted using 100% fee‐for‐service Medicare facility‐level claims data to identify patients who underwent de novo TV‐ICD implantation between 7/2016 and 1/2018. TV‐ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time‐dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.ResultsAmong 26,742 Medicare patients with de novo TV‐ICD, 518 (1.9%) had a device‐related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV‐ICD infection was associated with an increase of 2.4 (95% CI: 2.08–2.85) times in the mortality hazard ratio.ConclusionThe rate of TV‐ICD infection and associated mortality in a large, real‐world Medicare population is noteworthy. The positive association between device‐related infection and risk of mortality further highlights the need to reduce infections
Cover Image, Volume 32, Issue 11
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , Knight, Bradley P , Tzou, Wendy , Schaller, Robert D. , McLeod, Christopher J. , Natale, Andrea

Journal of Cardiovascular Electrophysiology | November 6, 2021 | Volume: 32 | Issue: 11 | Pages: No page available

10.1111/jce.15283 Get It

Evaluation of a novel cardiac signal processing system for electrophysiology procedures: The PURE EP 2.0 study
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , McLeod, Christopher , Natale, Andrea , Knight, Bradley P , Tzou, Wendy , Yasin, Omar , Padmanabhan, Deepak , Natale, Andrea , Schaller, Robert D. , McLeod, Christopher

Journal of Cardiovascular Electrophysiology | September 23, 2021 | Volume: 32 | Issue: 11 | Pages: 2915-2922

10.1111/jce.15250 Get It

AbstractBackgroundIntracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades.ObjectiveThe purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi‐center, prospective study.MethodsIntracardiac signal data of clinical interest were collected from 51 patients undergoing ablation procedures with PURE, the signal recording system, and the 3D mapping system at the same time stamps. The samples were randomized and subjected to blinded, controlled evaluation by three independent electrophysiologists to determine the overall quality and clinical utility of PURE signals when compared to conventional sources. Each reviewer assessed the same (92) signal sample sets and responded to (235) questions using a 10‐point rating scale. If two or more reviewers rated the PURE signal higher than the control, it was deemed superior.ResultsA total of 93% of question responses showed consensus amongst the blinded reviewers. Based on the ratings for each pair of signals, a cumulative total of 164 PURE signals out of 218 (75.2%) were statistically rated as Superior for this data set (p < .001). Only 14 PURE signals out of 218 were rated as Inferior (6.4%).ConclusionThe PURE intracardiac signals were statistically rated as superior when compared to conventional systems.
The extravascular implantable cardioverter‐defibrillator: The pivotal study plan
Crozier, Ian , O’Donnell, David , Boersma, Lucas V.A. , Murgatroyd, Francis , Manlucu, Jaimie , Knight, Bradley P. , Birgersdotter‐Green, Ulrika , Leclercq, Christophe , Thompson, Amy , Sawchuk, Robert, Willey, Sarah, Wiggenhorn, Christopher, Friedman, Paul A. , Friedman, Paul A , Knight, Bradley P , Boersma, Lucas , Crozier, Ian

Journal of Cardiovascular Electrophysiology | July 29, 2021 | Volume: 32 | Issue: 9 | Pages: 2371-2378

10.1111/jce.15190 Get It

AbstractBackgroundTransvenous implantable cardioverter defibrillators (TV ICD) provide life‐saving therapy for millions of patients worldwide. However, they are susceptible to several potential short‐ and long‐ term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD system's novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs.Study DesignThe EV ICD pivotal study is a prospective, multicenter, single‐arm, nonrandomized, premarket clinical study designed to examine the safety and acute efficacy of the system. This study will enroll up to 400 patients with a Class I or IIa indication for implantation of an ICD. Implanted subjects will be followed up to approximately 3.5 years, depending on when the patient is enrolled.ObjectiveThe clinical trial is designed to demonstrate safety and effectiveness of the EV ICD system in human use. The safety endpoint is freedom from major complications, while the efficacy endpoint is defibrillation success. Both endpoints will be assessed against prespecified criteria. Additionally, this study will evaluate antitachycardia pacing performance, electrical performance, extracardiac pacing sensation, asystole pacing, appropriate and inappropriate shocks, as well as a summary of adverse events.ConclusionThe EV ICD pivotal study is designed to provide clear evidence addressing the safety and efficacy performance of the EV ICD System.
Left Ventricular Extracellular Volume Expansion Is Not Associated with Atrial Fibrillation or Atrial Fibrillation–mediated Left Ventricular Systolic Dysfunction
Gunasekaran, Suvai , Lee, Daniel , Knight, Bradley P. , Fan, Lexiaozi , Collins, Jeremy D. , Chow, Kelvin , Carr, James , Kim, Daniel , Lee, Daniel C , Carr, James C. , Passman, Rod , Kim, Daniel , Knight, Bradley P , Collins, Jeremy , Kim, Daniel C.

Radiology: Cardiothoracic Imaging | April 23, 2020 | Volume: 2 | Issue: 2 | Pages: e190096

10.1148/ryct.2020190096 Get It

Diagnosis and management of subcutaneous implantable cardioverter‐defibrillator infections based on process mapping
Baddour, Larry M. , Weiss, Raul , Mark, George E., Biffi, Mauro , Probst, Vincent , Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Hansen, Linda K. , Knight, Bradley P. , El-Chami, Mikhael F , Biffi, Mauro , Probst, Vincent , Lambiase, Pier D , Hansen, Linda K , Knight, Bradley P , Baddour, Larry , Weiss, Raul , El‐Chami, Mikhael F.

Pacing and Clinical Electrophysiology | April 8, 2020 | Volume: 43 | Issue: 9 | Pages: 958-965

10.1111/pace.13902 Get It

AbstractBackgroundInfection is a well‐recognized complication of cardiovascular implantable electronic device (CIED) implantation, including the more recently available subcutaneous implantable cardioverter‐defibrillator (S‐ICD). Although the AHA/ACC/HRS guidelines include recommendations for S‐ICD use, currently there are no clinical trial data that address the diagnosis and management of S‐ICD infections. Therefore, an expert panel was convened to develop consensus on these topics.MethodsA process mapping methodology was used to achieve a primary goal – the development of consensus on the diagnosis and management of S‐ICD infections. Two face‐to‐face meetings of panel experts were conducted to recommend useful information to clinicians in individual patient management of S‐ICD infections.ResultsPanel consensus of a stepwise approach in the diagnosis and management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology in S‐ICD infection diagnosis and management was attainable, and the results should be helpful in individual patient management.