Abstract 4147545: Adverse Events with Pulsed Field Ablation - A Review of the Food and Drug Administration’s Manufacturer and User Facility Device Experience Database
Cooper, Julie , Zagrodzky, William , Zagrodzky, Jason , Omotoye, Samuel, Kaplan, Andrew , Bunch, T. Jared , Daniels, James , Sardana, Mayank , Link, Mark S.

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4147545 Get It

Introduction: Pulsed field ablation (PFA) is an adaptation of direct current ablation first used for catheter ablation in the 1980s. Expectations of a reduced risk profile led to the current resurgence in investment and interest in the technology as a potential alternative energy source for ablations to treat atrial fibrillation (AF). However, reports of adverse events, including new risks, are increasing. Research Question: How many adverse effects are reported with the use of newly available PFA systems? Aims: Quantify and describe the adverse events from PFA reported to date in the Food and Drug Administration’s (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. Methods: We searched the U.S. FDA’s MAUDE database for all reports filed with the code “QZI”, which is the product code for PFA systems created with the first FDA approvals in February 2024. All reports from inception through April 2024 (a total of 3 months) were included in this review. Per manufacturer presentation in May 2024, approximately 1000 cases utilizing PFA had been captured in a post-market registry of the predominant commercially used technology, but the exact number of cases can not be determined from MAUDE data. Results: A total of 217 adverse events were reported over the first 3 months of US approval, with 91 of these considered patient injuries. These injuries included 10 cases of cardiac tamponade, 7 reports of postoperative arrhythmia, 6 instances of device-related tissue entrapment, 5 cases of hemolysis with impaired renal function, 5 cases of stroke or TIA, including both embolic and hemorrhagic, 3 cases of intraoperative heart block, 2 coronary spasms, and 2 cases of intraoperative ST elevation. (Figure) Of the 91 reported patient safety events, 46 required hospitalization, 13 cases required temporary pacing, 11 required pericardiocentesis, 4 required dialysis, 4 required cardiothoracic surgery, and 2 required cardioversion. Conclusions: A number of adverse events have been reported to the MAUDE database in the first 3 months of FDA approval of PFA. The cardiac electrophysiology community should remain vigilant to ensure that the benefit-risk profile remains acceptable for patient safety.
Cover Image, Volume 32, Issue 11
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , Knight, Bradley P , Tzou, Wendy , Schaller, Robert D. , McLeod, Christopher J. , Natale, Andrea

Journal of Cardiovascular Electrophysiology | November 6, 2021 | Volume: 32 | Issue: 11 | Pages: No page available

10.1111/jce.15283 Get It

Evaluation of a novel cardiac signal processing system for electrophysiology procedures: The PURE EP 2.0 study
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , McLeod, Christopher , Natale, Andrea , Knight, Bradley P , Tzou, Wendy , Yasin, Omar , Padmanabhan, Deepak , Natale, Andrea , Schaller, Robert D. , McLeod, Christopher

Journal of Cardiovascular Electrophysiology | September 23, 2021 | Volume: 32 | Issue: 11 | Pages: 2915-2922

10.1111/jce.15250 Get It

AbstractBackgroundIntracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades.ObjectiveThe purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi‐center, prospective study.MethodsIntracardiac signal data of clinical interest were collected from 51 patients undergoing ablation procedures with PURE, the signal recording system, and the 3D mapping system at the same time stamps. The samples were randomized and subjected to blinded, controlled evaluation by three independent electrophysiologists to determine the overall quality and clinical utility of PURE signals when compared to conventional sources. Each reviewer assessed the same (92) signal sample sets and responded to (235) questions using a 10‐point rating scale. If two or more reviewers rated the PURE signal higher than the control, it was deemed superior.ResultsA total of 93% of question responses showed consensus amongst the blinded reviewers. Based on the ratings for each pair of signals, a cumulative total of 164 PURE signals out of 218 (75.2%) were statistically rated as Superior for this data set (p < .001). Only 14 PURE signals out of 218 were rated as Inferior (6.4%).ConclusionThe PURE intracardiac signals were statistically rated as superior when compared to conventional systems.