AbstractIntroductionThe use of intracardiac echocardiography (ICE) is beneficial during the ablation of atrial fibrillation (AF). Evidence is conflicting regarding the clinical impact of using ICE on arrhythmia recurrence and mortality.MethodsPatients undergoing catheter ablation of AF during 2010–2017 were identified using the International Classification of Diseases‐9th and 10th Revision‐Clinical Modification (ICD‐9‐CM and ICD‐10‐CM) from the Nationwide Readmissions Database. Propensity matching was used to generate a control group. Patient demographics, Charlson comorbidity indexes, time from discharge to readmission, and the reason of readmission were extracted.ResultsFrom 2010 to 2017, 51 129 patients were included in the analysis out of which ICE was used in 8005 (15.7%) patients. The in‐hospital mortality at readmission was significantly higher in the patients without ICE use (2.9% vs. 1.7%, p = .02). The length of stay (LOS) at readmission was significantly higher in non‐ICE arm (median [interquartile range, IQR]: 3 [2–6] vs. 2 [3–5] days, p < .0001) with similar healthcare‐associated cost (HAC) in both the groups (median [IQR]: US$7507.3 [4057.8–15 474.2] vs. 7339.4 [4024.8–15 191.6], p = .43). Freedom from readmission was 12% higher (hazard ratio [HR] [95% confidence interval, CI]: 0.88 [0.83–0.94], p < .0001) with the use of ICE at 90‐day follow‐up, which was driven by 24% reduction in heart failure (HF) at follow‐up (HR [95% CI]: 0.76 [0.60–0.96], p = .02).ConclusionsICE use during AF ablation procedure reduces readmissions at 90 days by 12%, driven by a 24% decrease in HF‐related admissions. The non‐ICE arm showed a significantly higher LOS which offsets marginally higher HAC in the ICE arm.
Frequency of Arrhythmias and Postural Orthostatic Tachycardia Syndrome in Patients With Marfan Syndrome: A Nationwide Inpatient Study
Background Marfan syndrome (MFS) is an autosomal dominant connective tissue disorder affecting multiple systems, particularly the cardiovascular system. The leading causes of death in MFS are aortopathies and valvular disease. We wanted to identify the frequency of arrhythmia and postural orthostatic tachycardia syndrome, length of hospital stay, health care–associated costs (HAC), and in‐hospital mortality in patients with MFS. Methods and Results The National Inpatient Sample database from 2005 to 2014 was queried using International Classification of Diseases, Ninth Revision, Clinical Modification ( ICD‐9‐CM ) codes for MFS and arrhythmias. Patients were classified into subgroups: supraventricular tachycardia, ventricular tachycardia (VT), atrial fibrillation, atrial flutter, and without any type of arrhythmia. Data about length of stay, HAC, and in‐hospital mortality were also abstracted from National Inpatient Sample database. Adjusted HAC was calculated as multiplying HAC and cost‐to‐charge ratio; 12 079 MFS hospitalizations were identified; 1893 patients (15.7%) had an arrhythmia; and 4.9% of the patients had postural orthostatic tachycardia syndrome. Median values of length of stay and adjusted HAC in VT group were the highest among the groups (VT: 6 days, $18 975.8; supraventricular tachycardia: 4 days, $11 906.6; atrial flutter: 4 days, $11 274.5; atrial fibrillation: 5 days, $10431.4; without any type of arrhythmia: 4 days, $8336.6; both P =0.0001). VT group had highest in‐patient mortality (VT: 5.3%, atrial fibrillation: 4.1%, without any type of arrhythmia: 2.1%, atrial flutter: 1.7%, supraventricular tachycardia: 0%; P <0.0001) even after adjustment for potential confounders (without any type of arrhythmia versus VT; odds ratio [95% CI]: 3.18 [1.62–6.24], P =0.001). Conclusions Arrhythmias and postural orthostatic tachycardia syndrome in MFS were high and associated with increased length of stay, HAC, and in‐hospital mortality especially in patients with VT.
Evaluation of a novel cardiac signal processing system for electrophysiology procedures: The PURE EP 2.0 study
AbstractBackgroundIntracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades.ObjectiveThe purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi‐center, prospective study.MethodsIntracardiac signal data of clinical interest were collected from 51 patients undergoing ablation procedures with PURE, the signal recording system, and the 3D mapping system at the same time stamps. The samples were randomized and subjected to blinded, controlled evaluation by three independent electrophysiologists to determine the overall quality and clinical utility of PURE signals when compared to conventional sources. Each reviewer assessed the same (92) signal sample sets and responded to (235) questions using a 10‐point rating scale. If two or more reviewers rated the PURE signal higher than the control, it was deemed superior.ResultsA total of 93% of question responses showed consensus amongst the blinded reviewers. Based on the ratings for each pair of signals, a cumulative total of 164 PURE signals out of 218 (75.2%) were statistically rated as Superior for this data set (p < .001). Only 14 PURE signals out of 218 were rated as Inferior (6.4%).ConclusionThe PURE intracardiac signals were statistically rated as superior when compared to conventional systems.