A 32-fold accelerated real-time cine MRI sequence (radial sampling) demonstrated better temporal resolution and image quality than a 16-fold sequence (Cartesian sampling) in patients with cardiac implantable electronic devices and arrhythmias.
Aortic velocity measurements derived from phase‐contrast MRI are influenced by a cardiac implantable electronic device in both adult and pediatric human subjects
AbstractPurposeOverall there is a lack of evidence on the accuracy and precision of phase‐contrast (PC) MRI in patients with cardiac implantable electronic devices (CIEDs). The purpose of this study is to determine whether aortic velocity measurements are influenced by a CIED.MethodsWe scanned 21 adult patients and 8 pediatric volunteers using clinical standard PC and real‐time PC (rt‐PC) sequences with and without a CIED generator taped on human subjects (below the left clavicle for adults and children; also on the abdomen for children) to mimic image artifacts. Peak and mean velocities above the aortic valve were calculated.ResultsThe Bland–Altman analyses on peak velocity measurements in pediatric subjects showed that both the accuracy and precision worsen as the distance between the CIED and aortic valve decreases (i.e., from abdomen to below the left clavicle). Specifically, both the bias and the coefficient of variation (CV) for both clinical PC and rt‐PC increased from the abdominal position (clinical: bias = −1.1%, CV = 4.3%; rt‐PC: bias = −0.3%, CV = 3.4%) to the clavicle position (clinical: bias = −4.0%, CV = 8.1%; rt‐PC: bias = 8.2%, CV = 7.3%). A similar trend was observed for mean velocity. The mean difference in peak and mean velocity measurements between rt‐PC with CIED (either position) and clinical standard PC with no CIED was within 7.5%. In adult patients, the mean difference between rt‐PC with CIED and clinical standard PC with CIED in peak velocity was 6.9%, and the CV was 7.9%.ConclusionThis study demonstrates that aortic velocity measurements are influenced by CIED in both adult and pediatric subjects.
Left Ventricular Extracellular Volume Expansion Is Not Associated with Atrial Fibrillation or Atrial Fibrillation–mediated Left Ventricular Systolic Dysfunction
AbstractIntroductionA recent study reported that diffuse left ventricular (LV) fibrosis is a predictor of atrial fibrillation (AF) recurrence following catheter ablation, by measuring postcontrast cardiac T1 (an error prone metric as per the 2017 Society for Cardiovascular Magnetic Resonance consensus statement) using an inversion‐recovery pulse sequence (an error prone method in arrhythmia) in AF ablation candidates. The purpose of this study was to verify the prior study, by measuring extracellular volume (ECV) fraction (an accurate metric) using a saturation‐recovery pulse sequence (accurate method in arrhythmia).Methods and ResultsThis study examined 100 AF patients (mean age = 62 ± 11 years, 69 males and 31 females, 67 paroxysmal [pAF] and 33 persistent [peAF]) who underwent a preablation cardiovascular magnetic resonance (CMR) exam. LV ECV and left atrial (LA) and LV functional parameters were quantified using standard analysis methods. During an average follow‐up period of 457 ± 261 days with 4 ± 3 rhythm checks per patient, 72 patients maintained sinus rhythm. Between those who maintained sinus rhythm (n = 72) and those who reverted to AF (n = 28), the only clinical characteristic that was significantly different was age (60 ± 12 years vs 66 ± 9 years); for CMR metrics, neither mean LV ECV (25.1 ± 3.3% vs 24.7 ± 3.7%), native LV T1 (1093.8 ± 73.5 ms vs 1070.2 ± 115.9 ms), left ventricular ejection fraction (54.1 ± 11.2% vs 55.7 ± 7.1%), nor LA end diastolic volume/body surface area (42.4 ± 14.8 mL/m2 vs 43.4 ± 19.6 mL/m2) were significantly different (P ≥ .23). According to Cox regression tests, none of the clinical and imaging variables predict AF recurrence.ConclusionNeither LV ECV nor other CMR metrics predict recurrence of AF following catheter ablation.
MR characterization of hepatic storage iron in transfusional iron overload