Back to Authors

Kim, Daniel

https://orcid.org/0000-0003-2660-8973

Mayo Clinic

Northwestern Memorial Hospital

Citations 6

Generative AI and Foundation Models in Radiology: Applications, Opportunities, and Potential Challenges
Tavakoli, Neda , Abad, Zahra Shakeri Hossein , Gowda, Vrushab, Samsel, Konrad , Bedayat, Arash , Ghasemiesfe, Ahmadreza , Bagci, Ulas, Hsiao, Albert , Leiner, Tim , Carr, James , Kim, Daniel , Shakeri, Zahra , Rahsepar, Amir Ali , Kim, Daniel , Leiner, Tim , Gowda, Vrushab , Bağcı, Ulaş

Radiology | November 18, 2025 | Volume: 317 | Issue: 2 | Pages: No page available

10.1148/radiol.242961 Get It

Foundation models can streamline imaging workflows, improve diagnostic accuracy, enable personalized treatment, and, via integrated generative artificial intelligence, create synthetic images to augment scarce real-world data; however, successful adoption requires explainability, trust, and workflow integration.
Highly Accelerated Real-time Cine MRI Pulse Sequence for Cardiac Implantable Electronic Devices and Arrhythmias
Bishara, Dima , Hong, KyungPyo , Davó-Jiménez, María , Collins, Jeremy D. , Topel, Çağdaş , Fan, Lexiaozi , Sarnari, Roberto, Knight, Bradley P. , Lee, Daniel , Kim, Daniel , Knight, Bradley P , Lee, Daniel C , Kim, Daniel , Collins, Jeremy

Radiology: Cardiothoracic Imaging | November 13, 2025 | Volume: 7 | Issue: 6 | Pages: No page available

10.1148/ryct.240554 Get It

A 32-fold accelerated real-time cine MRI sequence (radial sampling) demonstrated better temporal resolution and image quality than a 16-fold sequence (Cartesian sampling) in patients with cardiac implantable electronic devices and arrhythmias.
Aortic velocity measurements derived from phase‐contrast MRI are influenced by a cardiac implantable electronic device in both adult and pediatric human subjects
Yang, Huili , Aboyewa, Oluyemi , Shah, Dhaivat , Golestanirad, Laleh , Baraboo, Justin , Markl, Michael , Knight, Bradley P. , Hong, KyungPyo , Kim, Daniel , Hong, KyungPyo , Aboyewa, Oluyemi B , Shah, Dhaivat , Golestanirad, Laleh , Baraboo, Justin J , Collins, Jeremy D. , Kim, Daniel , Knight, Bradley P , Markl, Michael , Webster, Gregory , Patel, Amit R. , Lee, Daniel

Magnetic Resonance in Medicine | December 6, 2024 | Volume: 93 | Issue: 5 | Pages: 2099-2107

10.1002/mrm.30399 Get It

AbstractPurposeOverall there is a lack of evidence on the accuracy and precision of phase‐contrast (PC) MRI in patients with cardiac implantable electronic devices (CIEDs). The purpose of this study is to determine whether aortic velocity measurements are influenced by a CIED.MethodsWe scanned 21 adult patients and 8 pediatric volunteers using clinical standard PC and real‐time PC (rt‐PC) sequences with and without a CIED generator taped on human subjects (below the left clavicle for adults and children; also on the abdomen for children) to mimic image artifacts. Peak and mean velocities above the aortic valve were calculated.ResultsThe Bland–Altman analyses on peak velocity measurements in pediatric subjects showed that both the accuracy and precision worsen as the distance between the CIED and aortic valve decreases (i.e., from abdomen to below the left clavicle). Specifically, both the bias and the coefficient of variation (CV) for both clinical PC and rt‐PC increased from the abdominal position (clinical: bias = −1.1%, CV = 4.3%; rt‐PC: bias = −0.3%, CV = 3.4%) to the clavicle position (clinical: bias = −4.0%, CV = 8.1%; rt‐PC: bias = 8.2%, CV = 7.3%). A similar trend was observed for mean velocity. The mean difference in peak and mean velocity measurements between rt‐PC with CIED (either position) and clinical standard PC with no CIED was within 7.5%. In adult patients, the mean difference between rt‐PC with CIED and clinical standard PC with CIED in peak velocity was 6.9%, and the CV was 7.9%.ConclusionThis study demonstrates that aortic velocity measurements are influenced by CIED in both adult and pediatric subjects.
Left Ventricular Extracellular Volume Expansion Is Not Associated with Atrial Fibrillation or Atrial Fibrillation–mediated Left Ventricular Systolic Dysfunction
Gunasekaran, Suvai , Lee, Daniel , Knight, Bradley P. , Fan, Lexiaozi , Collins, Jeremy D. , Chow, Kelvin , Carr, James , Kim, Daniel , Lee, Daniel C , Carr, James C. , Passman, Rod , Kim, Daniel , Knight, Bradley P , Collins, Jeremy , Kim, Daniel C.

Radiology: Cardiothoracic Imaging | April 23, 2020 | Volume: 2 | Issue: 2 | Pages: e190096

10.1148/ryct.2020190096 Get It

Left ventricular extracellular volume expansion does not predict recurrence of atrial fibrillation following catheter ablation
Gunasekaran, Suvai , Lee, Daniel , Knight, Bradley P. , Fan, Lexiaozi , Trivedi, Amar, Ragin, Ann , Carr, James , Kim, Daniel , Collins, Jeremy D. , Kim, Daniel , Knight, Bradley P , Lee, Daniel C , Passman, Rod

Pacing and Clinical Electrophysiology | December 4, 2019 | Volume: 43 | Issue: 2 | Pages: 159-166

10.1111/pace.13853 Get It

AbstractIntroductionA recent study reported that diffuse left ventricular (LV) fibrosis is a predictor of atrial fibrillation (AF) recurrence following catheter ablation, by measuring postcontrast cardiac T1 (an error prone metric as per the 2017 Society for Cardiovascular Magnetic Resonance consensus statement) using an inversion‐recovery pulse sequence (an error prone method in arrhythmia) in AF ablation candidates. The purpose of this study was to verify the prior study, by measuring extracellular volume (ECV) fraction (an accurate metric) using a saturation‐recovery pulse sequence (accurate method in arrhythmia).Methods and ResultsThis study examined 100 AF patients (mean age = 62 ± 11 years, 69 males and 31 females, 67 paroxysmal [pAF] and 33 persistent [peAF]) who underwent a preablation cardiovascular magnetic resonance (CMR) exam. LV ECV and left atrial (LA) and LV functional parameters were quantified using standard analysis methods. During an average follow‐up period of 457 ± 261 days with 4 ± 3 rhythm checks per patient, 72 patients maintained sinus rhythm. Between those who maintained sinus rhythm (n = 72) and those who reverted to AF (n = 28), the only clinical characteristic that was significantly different was age (60 ± 12 years vs 66 ± 9 years); for CMR metrics, neither mean LV ECV (25.1 ± 3.3% vs 24.7 ± 3.7%), native LV T1 (1093.8 ± 73.5 ms vs 1070.2 ± 115.9 ms), left ventricular ejection fraction (54.1 ± 11.2% vs 55.7 ± 7.1%), nor LA end diastolic volume/body surface area (42.4 ± 14.8 mL/m2 vs 43.4 ± 19.6 mL/m2) were significantly different (P ≥ .23). According to Cox regression tests, none of the clinical and imaging variables predict AF recurrence.ConclusionNeither LV ECV nor other CMR metrics predict recurrence of AF following catheter ablation.
MR characterization of hepatic storage iron in transfusional iron overload
Tang, Haiying, Jensen, Jens H. , Sammet, Christina L., Sheth, Sujit , Swaminathan, Srirama V., Hultman, Kristi, Wu, EX , Brown, Truman R. , Brittenham, Gary M. , Kim, Daniel , Kim, Daniel , Kim, Daniel

Journal of Magnetic Resonance Imaging | May 29, 2013 | Volume: 39 | Issue: 2 | Pages: 307-316

10.1002/jmri.24171 Get It

PurposeTo quantify the two principal forms of hepatic storage iron, diffuse, soluble iron (primarily ferritin), and aggregated, insoluble iron (primarily hemosiderin) using a new MRI method in patients with transfusional iron overload.Materials and MethodsSix healthy volunteers and 20 patients with transfusion‐dependent thalassemia syndromes and iron overload were examined. Ferritin‐ and hemosiderin‐like iron were determined based on the measurement of two distinct relaxation parameters: the “reduced” transverse relaxation rate, RR2, and the “aggregation index,” A, using three sets of Carr‐Purcell‐Meiboom‐Gill (CPMG) datasets with different interecho spacings. Agarose phantoms, simulating the relaxation and susceptibility properties of tissue with different concentrations of dispersed (ferritin‐like) and aggregated (hemosiderin‐like) iron, were used for validation.ResultsBoth phantom and in vivo human data confirmed that transverse relaxation components associated with the dispersed and aggregated iron could be separated using the two‐parameter (RR2, A) method. The MRI‐determined total hepatic storage iron was highly correlated (r = 0.95) with measurements derived from biopsy or biosusceptometry. As total hepatic storage iron increased, the proportion stored as aggregated iron became greater.ConclusionThis method provides a new means for noninvasive MRI determination of the partition of hepatic storage iron between ferritin and hemosiderin in iron overload disorders. J. Magn. Reson. Imaging 2014;39:307–316. © 2013 Wiley Periodicals, Inc.