Back to Authors

Kim, Daniel

0000-0003-0470-8279

Mayo Clinic

Northwestern University

Citations 2

Abstract 4362826: Use of Stress Cardiac Magnetic Resonance to Evaluate Prognosis in Patients with Cardiac Implantable Electronic Devices
Jimenez, M. , Starrett, Lane, Topel, Çağdaş , Jaamour, Dania , Gill, Nathan , Hong, KyungPyo , Knight, Bradley P. , Knight, Bradley P , Jimenez, Maria Davo, Fan, Lexiaozi , Urban, Jacqueline Bexiga , Behnoush, Amir Hossein , Collins, Jeremy D. , Patel, Amit R. , Kim, Daniel , Lee, Daniel

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4362826 Get It

Background: The prevalence of cardiac implantable electronic devices (CIED) is increasing, with over 300,000 new implants annually in the U.S. Stress cardiac magnetic resonance (CMR) has proven as a powerful modality for myocardial characterization, enabling accurate diagnosis of different cardiac conditions. In patients without devices, CMR findings have also demonstrated prognostic value for major adverse cardiovascular events (MACE) and guide clinical decision-making. However, its use in CIED patients has historically been limited due to safety and image quality concerns. Hypothesis: We aimed to evaluate the prognostic value of CMR imaging using wideband sequences in CIED patients. Methods: CIED patients referred for clinical CMR were included prospectively and retrospectively between January 2020 and February 2025. All patients underwent a stress CMR protocol, which included cine, wideband late gadolinium enhancement (LGE), wideband T1 mapping, and wideband stress/rest perfusion imaging. Clinical follow-up is ongoing. The primary endpoint was the occurrence of MACE, defined as the composite of myocardial infarction, heart failure hospitalization, implantable cardioverter defibrillator (ICD) therapy, cardiac death, revascularization, or heart transplant. Results: A total of 89 patients were included (median age 69.0 [58.0–75.5] years; 62.9% male). Device types included pacemakers (33.7%), ICDs (48.3%), and cardiac resynchronization therapy devices (16.9%). Over a median of follow-up of 613 days [355-991], 21 patients experienced a MACE. In unadjusted models, higher left ventricular ejection fraction (LVEF) (per 5%) was significantly associated with a lower risk of MACE (odds ratio [OR] 0.80, 95% confidence interval [CI] 0.65–0.95; p=0.016), as was higher stress myocardial blood flow (MBF) (per 0.25 mL/g/min increase: OR 0.78, 95% CI 0.60–0.98; p=0.05). In contrast, greater LV myocardial mass (per 10 g) was significantly associated with a higher risk of MACE (OR 1.27, 95% CI 1.08–1.52; p = 0.006), figure 1. Conclusion: The use of wideband sequences enabled the assessment of prognostic imaging value in CIED patients. LVEF remains a strong and consistent predictor of MACE in this population and LV mass was significantly associated with higher rates of MACE reflecting the influence of underlying cardiomyopathy. While stress perfusion CMR imaging showed promising trends, further studies with longer follow-up are needed to clarify its prognostic value in this population.
MR characterization of hepatic storage iron in transfusional iron overload
Tang, Haiying, Jensen, Jens H. , Sammet, Christina L., Sheth, Sujit , Swaminathan, Srirama V., Hultman, Kristi, Wu, EX , Brown, Truman R. , Brittenham, Gary M. , Kim, Daniel , Kim, Daniel , Kim, Daniel

Journal of Magnetic Resonance Imaging | May 29, 2013 | Volume: 39 | Issue: 2 | Pages: 307-316

10.1002/jmri.24171 Get It

PurposeTo quantify the two principal forms of hepatic storage iron, diffuse, soluble iron (primarily ferritin), and aggregated, insoluble iron (primarily hemosiderin) using a new MRI method in patients with transfusional iron overload.Materials and MethodsSix healthy volunteers and 20 patients with transfusion‐dependent thalassemia syndromes and iron overload were examined. Ferritin‐ and hemosiderin‐like iron were determined based on the measurement of two distinct relaxation parameters: the “reduced” transverse relaxation rate, RR2, and the “aggregation index,” A, using three sets of Carr‐Purcell‐Meiboom‐Gill (CPMG) datasets with different interecho spacings. Agarose phantoms, simulating the relaxation and susceptibility properties of tissue with different concentrations of dispersed (ferritin‐like) and aggregated (hemosiderin‐like) iron, were used for validation.ResultsBoth phantom and in vivo human data confirmed that transverse relaxation components associated with the dispersed and aggregated iron could be separated using the two‐parameter (RR2, A) method. The MRI‐determined total hepatic storage iron was highly correlated (r = 0.95) with measurements derived from biopsy or biosusceptometry. As total hepatic storage iron increased, the proportion stored as aggregated iron became greater.ConclusionThis method provides a new means for noninvasive MRI determination of the partition of hepatic storage iron between ferritin and hemosiderin in iron overload disorders. J. Magn. Reson. Imaging 2014;39:307–316. © 2013 Wiley Periodicals, Inc.