Back to Authors

Asirvatham, Samuel J

0000-0001-9835-5536

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester (K.Q.A., J.A.T., I.U.H., A.W., H.N., A.B., S.Y., R.W., F.E., N.Y.T., F.D.-C.M., S.A., C.V.D.).

Citations 269

Local calcium chloride infusion after pulsed field ablation enhances acute efficacy of cardiac electroporation
Otsuka, Naoto , Tri, Jason , Sauer, William H. , Asirvatham, Samuel J, Nguyen, Duy Tien, Asirvatham, Samuel J. , Sauer, William H. , Koya, Taro , Tri, Jason A , Sauer, William H , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | October 4, 2024 | Volume: 35 | Issue: 12 | Pages: 2354-2360

10.1111/jce.16439 Get It

AbstractIntroductionPulsed field ablation (PFA) has emerged as an innovative therapy for cardiac arrhythmias. Drawing parallels with PFA's application in solid tumors, calcium chloride (CaCl2) as an adjuvant therapy, known as calcium electroporation, may amplify PFA's apoptotic effects. We propose that PFA in the atrium could enhance calcium uptake through PFA‐created pores, thereby increasing ablation efficacy even at reduced power levels by exploiting PFA's permeabilization effects.MethodsWe conducted in vivo ablations on the atria of seven pigs using low PFA power (250 V, 20 μs for 50 pulses at 200 ms intervals). Post‐PFA, we randomly administered an infusion of either 200 mg/2 ml CaCl2 (calcium group) or saline (control) directly to the ablation site via the catheter tip. We evaluated reduction in electrogram voltage amplitude, electrocardiography (ECG) parameters, ablation lesion parameters, and histology after PFA.ResultsNineteen lesions from control and calcium groups were examined. Control lesions showed no voltage decrease post‐PFA, whereas calcium‐treated lesions exhibited a significant voltage reduction. Gross pathology indicated marked differences in maximum lesion surface diameter, depth, and volume between the lesion groups. Histologically, calcium group lesions were characterized by a more severe acute PFA response with contraction band necrosis, myocytolysis and nuclear pyknosis in adjacent myocardium, in addition to microhemorrhages.ConclusionInfusing calcium chloride locally after PFA markedly improves the immediate efficacy of electroporation in porcine atria. This study suggests that calcium electroporation could bolster PFA outcomes without higher energy levels, potentially diminishing associated risks. These preliminary findings warrant further research into the long‐term efficacy and potential clinical application of calcium electroporation in PFA.
Pulsed Field Ablation: A Comprehensive Update
Asirvatham, Samuel J. , Nguyen, Duy Tien, Asirvatham, Samuel J , Ezzeddine, Fatima M.

Journal of Clinical Medicine | September 2, 2024 | Volume: 13 | Issue: 17 | Pages: 5191

10.3390/jcm13175191 Get It

One of the recent advancements in the field of cardiac electrophysiology is pulsed field ablation (PFA). PFA is a novel energy modality that does not rely on thermal processes to achieve ablation which, in turn, results in limited collateral damage to surrounding structures. In this review, we discuss the mechanisms, safety, efficacy, and clinical applications of PFA for the management of atrial and ventricular arrhythmias. We also summarize the published pre-clinical and clinical studies regarding this new technology.
Direct Comparison of Methods to Differentiate Wide Complex Tachycardias: Novel Automated Algorithms Versus Manual ECG Interpretation Approaches
LoCoco, Sarah , Kashou, Anthony H. , Deshmukh, Abhishek , Asirvatham, Samuel J. , DeSimone, Christopher V. , Mikhova, Krasimira M., Sodhi, Sandeep , Cuculich, Phillip S. , Ghadban, Rugheed , Cooper, Daniel , Deshmukh, Abhishek J , Sodhi, Sandeep S , Maddox, Thomas M , Noseworthy, Peter A , May, Adam M , Asirvatham, Samuel J , DeSimone, Christopher V , Noseworthy, Peter A. , May, Adam M.

Circulation: Arrhythmia and Electrophysiology | July 25, 2024 | Volume: 17 | Issue: 8 | Pages: No page available

10.1161/circep.123.012663 Get It

BACKGROUND: Differentiating wide complex tachycardias (WCTs) into ventricular tachycardia (VT) and supraventricular wide tachycardia via 12-lead ECG interpretation is a crucial but difficult task. Automated algorithms show promise as alternatives to manual ECG interpretation, but direct comparison of their diagnostic performance has not been undertaken. METHODS: Two electrophysiologists applied 3 manual WCT differentiation approaches (ie, Brugada, Vereckei aVR, and VT score). Simultaneously, computerized data from paired WCT and baseline ECGs were processed by 5 automated WCT differentiation algorithms (WCT Formula, WCT Formula II, VT Prediction Model, Solo Model, and Paired Model). The diagnostic performance of automated algorithms was compared with manual ECG interpretation approaches. RESULTS: A total of 212 WCTs (111 VT and 101 supraventricular wide tachycardia) from 104 patients were analyzed. WCT Formula demonstrated superior accuracy (85.8%) and specificity (87.1%) compared with Brugada (75.2% and 57.4%, respectively) and Vereckei aVR (65.3% and 36.4%, respectively). WCT Formula II achieved higher accuracy (89.6%) and specificity (85.1%) against Brugada and Vereckei aVR. Performance metrics of the WCT Formula (accuracy 85.8%, sensitivity 84.7%, and specificity 87.1%) and WCT Formula II (accuracy 89.8%, sensitivity 89.6%, and specificity 85.1%) were similar to the VT score (accuracy 84.4%, sensitivity 93.8%, and specificity 74.2%). Paired Model was superior to Brugada in accuracy (89.6% versus 75.2%), specificity (97.0% versus 57.4%), and F1 score (0.89 versus 0.80). Paired Model surpassed Vereckei aVR in accuracy (89.6% versus 65.3%), specificity (97.0% versus 75.2%), and F1 score (0.89 versus 0.74). Paired Model demonstrated similar accuracy (89.6% versus 84.4%), inferior sensitivity (79.3% versus 93.8%), but superior specificity (97.0% versus 74.2%) to the VT score. Solo Model and VT Prediction Model accuracy (82.5% and 77.4%, respectively) was superior to the Vereckei aVR (65.3%) but similar to Brugada (75.2%) and the VT score (84.4%). CONCLUSIONS: Automated WCT differentiation algorithms demonstrated favorable diagnostic performance compared with traditional manual ECG interpretation approaches.
Mitral valve prolapse: arrhythmic risk during pregnancy and postpartum
Sabbag, Avi , Aabel, Eivind W. , Castrini, Anna Isotta , Siontis, Konstantinos C. , Duthoit, Guillaume , Asirvatham, Samuel J. , Sehrawat, Ojasay, Kirkels, Feddo P. , Rav, Moshe , Peichl, Petr , Lim, H. , Martins, Raphaël P. , Font, Jonaz , Truong, Nguyen Ngoc Khoi , Estensen, Mette E , Laredo, Mikael , Duthoit, Guillaume , Kirkels, Feddo P , Beinart, Roy , Peichl, Petr , Sohns, Christian , Haugaa, Kristina , Asirvatham, Samuel J , Martins, Raphael , Aabel, Eivind W , Sabbag, Avi , Nizard, J. , Rosendael, Philippe J. van , Beinart, Roy , Haugaa, Kristina H.

European Heart Journal | May 14, 2024 | Volume: 45 | Issue: 20 | Pages: 1831-1839

10.1093/eurheartj/ehae224 Get It

Abstract Background and Aims Arrhythmic mitral valve prolapse (AMVP) is linked to life-threatening ventricular arrhythmias (VAs), and young women are considered at high risk. Cases of AMVP in women with malignant VA during pregnancy have emerged, but the arrhythmic risk during pregnancy is unknown. The authors aimed to describe features of women with high-risk AMVP who developed malignant VA during the perinatal period and to assess if pregnancy and the postpartum period were associated with a higher risk of malignant VA. Methods This retrospective international multi-centre case series included high-risk women with AMVP who experienced malignant VA and at least one pregnancy. Malignant VA included ventricular fibrillation, sustained ventricular tachycardia, or appropriate shock from an implantable cardioverter defibrillator. The authors compared the incidence of malignant VA in non-pregnant periods and perinatal period; the latter defined as occurring during pregnancy and within 6 months after delivery. Results The authors included 18 women with AMVP from 11 centres. During 7.5 (interquartile range 5.8–16.6) years of follow-up, 37 malignant VAs occurred, of which 18 were pregnancy related occurring in 13 (72%) unique patients. Pregnancy and 6 months after delivery showed increased incidence rate of malignant VA compared to the non-pregnancy period (univariate incidence rate ratio 2.66, 95% confidence interval 1.23–5.76). Conclusions The perinatal period could impose increased risk of malignant VA in women with high-risk AMVP. The data may provide general guidance for pre-conception counselling and for nuanced shared decision-making between patients and clinicians.
Unlocking the potential of artificial intelligence in electrocardiogram biometrics: age-related changes, anomaly detection, and data authenticity in mobile health platforms
Mangold, Kathryn, Carter, Rickey E. , Siontis, Konstantinos C. , López-Jiménez, Francisco , Asirvatham, Samuel J. , Friedman, Paul A. , Attia, Zachi I. , Mangold, Kathryn E , Lopez-Jimenez, Francisco , Attia, Zachi I , Asirvatham, Samuel J , Carter, Rickey E , Noseworthy, Peter A.

European Heart Journal - Digital Health | April 22, 2024 | Volume: 5 | Issue: 3 | Pages: 314-323

10.1093/ehjdh/ztae024 Get It

Abstract Aims Mobile devices such as smartphones and watches can now record single-lead electrocardiograms (ECGs), making wearables a potential screening tool for cardiac and wellness monitoring outside of healthcare settings. Because friends and family often share their smart phones and devices, confirmation that a sample is from a given patient is important before it is added to the electronic health record. Methods and results We sought to determine whether the application of Siamese neural network would permit the diagnostic ECG sample to serve as both a medical test and biometric identifier. When using similarity scores to discriminate whether a pair of ECGs came from the same patient or different patients, inputs of single-lead and 12-lead medians produced an area under the curve of 0.94 and 0.97, respectively. Conclusion The similar performance of the single-lead and 12-lead configurations underscores the potential use of mobile devices to monitor cardiac health.
Long‐term outcomes with abandoning versus extracting sterile leads: A 10‐year population‐based study
Lee, Justin Z. , Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Asirvatham, Samuel J. , Kusumoto, Fred , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Valverde, Arturo, Asirvatham, Samuel J , Kusumoto, Fred M , Cha, Yong-Mei , Srivathsan, Komandoor

Pacing and Clinical Electrophysiology | March 16, 2024 | Volume: 47 | Issue: 5 | Pages: 626-634

10.1111/pace.14940 Get It

Abstract Background Long‐term outcomes of sterile lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) remain unclear. Methods We performed a retrospective study of a population residing in southeastern Minnesota with follow‐up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE of sterile leads from January 1, 2000, to January 1, 2011, and had follow‐up for at least 10 years or until their death were included. Results A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. Indications for subsequent lead extraction arose in 9.1% ( n = 14) of patients with initial LA and 5.3% ( n = 1) in patients with initial TLE, after an average of 7 years. Moreover, 28.6% of patients in the LA cohort who required subsequent extraction did not proceed with the extraction, and among those who proceeded, 60% had clinical success and 40% had a clinical failure. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges (5.2% vs. 5.3%). There was no difference in 10‐year survival probability among the LA group and the TLE group ( p = .64). Conclusion An initial lead abandonment strategy was associated with more complicated subsequent extraction procedures compared to patients with an initial transvenous lead extraction strategy. However, there was no difference in 10‐year survival probability between both lead management approaches.
First‐in‐man report of transsubclavian venous implantation of the Aveir leadless cardiac pacing system
Ward, Robert C. , Amin, Hina , Noseworthy, Peter A. , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Balanescu, Dinu V , Ward, Robert C , Noseworthy, Peter A , Asirvatham, Samuel J , Friedman, Paul A , Mulpuru, Siva K , Balanescu, Dinu Valentin

Journal of Cardiovascular Electrophysiology | March 11, 2024 | Volume: 35 | Issue: 5 | Pages: 1041-1045

10.1111/jce.16241 Get It

Abstract Introduction Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. Methods and Results Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same‐day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. Conclusions We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.
Cardiac implantable electronic devices in female patients: Esthetic, breast implant, and anatomic considerations
Salinas, Cristina A., Mulpuru, Siva K. , Asirvatham, Samuel J. , Sharaf, Basel , Ezzeddine, Fatima , Mulpuru, Siva K , Asirvatham, Samuel J , Sharaf, Basel A, Sharaf, Basel A , Ezzeddine, Fatima M.

Journal of Cardiovascular Electrophysiology | February 15, 2024 | Volume: 35 | Issue: 4 | Pages: 747-761

10.1111/jce.16196 Get It

Abstract Introduction The implantation of a cardiac implantable electronic device (CIED) can have esthetic and psychological consequences on patients. We explore a heart team model for care coordination and discuss esthetic approaches for improved cosmetic outcomes in patients undergoing (CIED)‐related procedures or de novo implantation. Methods Patients undergoing CIED surgery for approved indications between June 2015 and June 2022 were identified. Patients were included when surgical care was provided by a collaborative relationship between the primary electrophysiologist and the plastic surgeon. Patient demographics, details of the surgical procedure, information on breast implants, complications, and outcomes related to cosmesis were recorded. Results Twenty‐two female patients were included in this study. The mean age was 50.2 ± 18.2 years. The mean follow‐up duration was 2.2 ± 5.5 months. The top two indications for the procedure included CIED generator change ( n = 9, 41%) and implantable cardioverter‐defibrillator (ICD) implantation ( n = 7, 32%). The most common reasons for involving plastic surgery in the procedure included surgery near breast implants ( n = 10, 45%) and device displacement or discomfort ( n = 8, 36%). CIED pocket position was prepectoral in 10 cases (45%), subpectoral in 11 patients (50%), and intramuscular in one patient (4.5%). The majority of the patients (20, 91%) had cosmetically acceptable results postprocedure. One patient (4.5%) had breast asymmetry on the CIED side, and another continued to have skin erosion over the CIED and leads. Conclusion A heart team approach incorporating the expertize of cardiac electrophysiology and plastic surgery is essential for providing optimal care for patients with breast implants and patients requesting esthetic appeal.
Single-dose Intraoperative Steroid Administration Does Not Impact Early Atrial Fibrillation Recurrence
Agboola, Kolade M. , Karki, Roshan , Lodhi, Fahad, McGill, Trevon, Asirvatham, Samuel J. , Deshmukh, Abhishek , DeSimone, Christopher V. , Asirvatham, Samuel J , DeSimone, Christopher V , Dietrich, Michael

No container title available | January 30, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.170665173.32820618/v1 Get It

Background: Inflammation is integral in the pathogenesis and propagation of atrial fibrillation (AF). Peri-ablation administration of steroids has been shown to significantly reduce AF recurrence at 3 months. We sought to determine the effect of intraoperative dexamethasone on early recurrence at both 3 months and 12 months post-ablation. Methods: A cohort of 94 adult patients (>18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring at less than 3 months or between 3 months and 1 year with an in-person follow-up visit. Results: A total of 36.2% of patients received intravenous dexamethasone compared to 63.8% who did not (providing a 2:1 comparison group). The incidence of documented AF or flutter lasting greater than 30 seconds was 20.6% in the dexamethasone group versus 21.7% in the non-dexamethasone group, p value 1.00. AF or atrial flutter recurrence from 3 months to 1 year was 20.6% in the dexamethasone group compared to 21.7% in the non-dexamethasone group, p value 1.00. Conclusion: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis does not have a significant effect on AF recurrence rates.
Incidence and Outcomes of New-Onset Right Bundle Branch Block Following Transcatheter Aortic Valve Replacement
Tan, Nicholas Y. , Adedinsewo, Demilade , Sabbagh, Abdallah El , Ahmed, Ahmed F. Sayed , Morales-Lara, Andrea Carolina , Wieczorek, Mikolaj A. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Asirvatham, Samuel J. , Eleid, Mackram F. , Friedman, Paul A. , Cha, Yong‐Mei , Killu, Ammar M. , El Sabbagh, Abdallah , Sayed Ahmed, Ahmed F , Carolina Morales-Lara, Andrea , Wieczorek, Mikolaj, Deshmukh, Abhishek J , Asirvatham, Samuel J , Adedinsewo, Demilade A

Circulation: Arrhythmia and Electrophysiology | January 30, 2024 | Volume: 17 | Issue: 2 | Pages: No page available

10.1161/circep.123.012377 Get It

BACKGROUND: The incidence and prognosis of right bundle branch block (RBBB) following transcatheter aortic valve replacement (TAVR) are unknown. Hence, we sought to characterize the incidence of post-TAVR RBBB and determine associated risks of permanent pacemaker (PPM) implantation and mortality. METHODS: All patients 18 years and above without preexisting RBBB or PPM who underwent TAVR at US Mayo Clinic sites and Mayo Clinic Health Systems from June 2010 to May 2021 were evaluated. Post-TAVR RBBB was defined as new-onset RBBB in the postimplantation period. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. RESULTS: Of 1992 patients, 15 (0.75%) experienced new RBBB post-TAVR. There was a higher degree of valve oversizing among patients with new RBBB post-TAVR versus those without (17.9% versus 10.0%; P =0.034). Ten patients (66.7%) with post-TAVR RBBB experienced high-grade atrioventricular block and underwent PPM implantation (median 1 day; Q1, 0.2 and Q3, 4), compared with 268/1977 (13.6%) without RBBB. Following propensity score adjustment for covariates (age, sex, balloon-expandable valve, annulus diameter, and valve oversizing), post-TAVR RBBB was significantly associated with PPM implantation (hazard ratio, 8.36 [95% CI, 4.19–16.7]; P <0.001). No statistically significant increase in mortality was seen with post-TAVR RBBB (hazard ratio, 0.83 [95% CI, 0.33–2.11]; P =0.69), adjusting for age and sex. CONCLUSIONS: Although infrequent, post-TAVR RBBB was associated with elevated PPM implantation risk. The mechanisms for its development and its clinical prognosis require further study.