Background: Inflammation is integral in the pathogenesis and propagation of atrial fibrillation (AF). Peri-ablation administration of steroids has been shown to significantly reduce AF recurrence at 3 months. We sought to determine the effect of intraoperative dexamethasone on early recurrence at both 3 months and 12 months post-ablation. Methods: A cohort of 94 adult patients (>18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring at less than 3 months or between 3 months and 1 year with an in-person follow-up visit. Results: A total of 36.2% of patients received intravenous dexamethasone compared to 63.8% who did not (providing a 2:1 comparison group). The incidence of documented AF or flutter lasting greater than 30 seconds was 20.6% in the dexamethasone group versus 21.7% in the non-dexamethasone group, p value 1.00. AF or atrial flutter recurrence from 3 months to 1 year was 20.6% in the dexamethasone group compared to 21.7% in the non-dexamethasone group, p value 1.00. Conclusion: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis does not have a significant effect on AF recurrence rates.
Automatic wide complex tachycardia differentiation using mathematically synthesized vectorcardiogram signals
AbstractBackgroundAutomated wide complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) may be accomplished using novel calculations that quantify the extent of mean electrical vector changes between the WCT and baseline electrocardiogram (ECG). At present, it is unknown whether quantifying mean electrical vector changes within three orthogonal vectorcardiogram (VCG) leads (X, Y, and Z leads) can improve automated VT and SWCT classification.MethodsA derivation cohort of paired WCT and baseline ECGs was used to derive five logistic regression models: (i) one novel WCT differentiation model (i.e., VCG Model), (ii) three previously developed WCT differentiation models (i.e., WCT Formula, VT Prediction Model, and WCT Formula II), and (iii) one “all‐inclusive” model (i.e., Hybrid Model). A separate validation cohort of paired WCT and baseline ECGs was used to trial and compare each model's performance.ResultsThe VCG Model, composed of WCT QRS duration, baseline QRS duration, absolute change in QRS duration, X‐lead QRS amplitude change, Y‐lead QRS amplitude change, and Z‐lead QRS amplitude change, demonstrated effective WCT differentiation (area under the curve [AUC] 0.94) for the derivation cohort. For the validation cohort, the diagnostic performance of the VCG Model (AUC 0.94) was similar to that achieved by the WCT Formula (AUC 0.95), VT Prediction Model (AUC 0.91), WCT Formula II (AUC 0.94), and Hybrid Model (AUC 0.95).ConclusionCustom calculations derived from mathematically synthesized VCG signals may be used to formulate an effective means to differentiate WCTs automatically.
Single-Dose Intraoperative Steroid Administration Does Not Impact Early Atrial Fibrillation Recurrence
Abstract Purpose: To evaluate the effect of single-dose intravenous dexamethasone on AF recurrence following radiofrequency catheter ablation. Methods: A cohort of 94 adult patients (>18 years) underwent catheter ablation at Mayo Clinic Rochester from January to March 2019. Only first-time ablation patients were included, with all re-do ablations excluded to minimize heterogeneity. Administration of intraoperative dexamethasone 4 mg or 8 mg was determined by chart review from the procedure. At our institution, intraoperative intravenous steroids are administered for postoperative nausea and vomiting (PONV) prophylaxis at the discretion of the anesthesiologist. AF recurrence was determined by ECG or cardiac monitoring at less than 3 months or between 3 months and 1 year with an in-person follow-up visit. Results: A total of 36.2% of patients received intravenous dexamethasone compared to 63.8% who did not (providing a 2:1 comparison group). The incidence of documented AF or flutter lasting greater than 30 seconds was 20.6% in the dexamethasone group versus 21.7% in the non-dexamethasone group, p value 1.00. AF or atrial flutter recurrence from 3 months to 1 year was 20.6% in the dexamethasone group compared to 21.7% in the non-dexamethasone group, p value 1.00. Conclusion: These data suggest that intraoperative intravenous dexamethasone administered during AF ablation for postoperative nausea and vomiting prophylaxis does not have a significant effect on AF recurrence rates.
The Role of Genetic Testing in the Evaluation of Dilated Cardiomyopathies
We present an adolescent African American male admitted to the cardiac intensive care unit with cardiogenic shock and acute respiratory failure. Through an overview of his presentation, diagnostic workup, and treatment, we demonstrate the clinical utility of genetic testing in the evaluation of unexplained dilated cardiomyopathies.
Infection Rate and Outcomes of Watchman Devices: Results from a Single Center 14-Year Experience
Background: Left atrial appendage occlusion with the Watchman device is an alternative strategy for stroke risk reduction in patients with non-valvular atrial fibrillation. There are rare case reports of Watchman associated infection. Currently, there is no formal study that evaluated the incidence and outcomes of Watchman-related infections. Methods: All patients who underwent Watchman implantation over a 14 year study period (July 2004 through December 2018) comprised our cohort. Baseline characteristics, procedural data, and post-implantation events were identified. Primary study outcomes included Watchman related infection, other cardiovascular device related infection, bacteremia, and mortality. Results: A total of 181 patients with an average age of 75, and a median CHA2DS2-VASc Score of 4 (interquartile range 2) and a median HAS-BLED Score of 3 (interquartile range 1), were included for analysis. A total of 534.7 patient years of follow up was accrued with an average of 2.9 years per patient. The most common indications for implantation included gastrointestinal bleeding (56 patients; 30.9%) and intracerebral bleeding (51 patients; 28.2%). During follow up, 38 patients (21%) died. Six developed evidence of bacteremia. Only one developed an implantable cardioverter defibrillator (ICD) infection that required complete system extraction. None of the cohort developed Watchman-related device infection during the study period. Conclusion: In a single center study spanning a 14 year period, we report no Watchman-related devices infections. This is despite the presence of patients with bacteremia, as well as an ICD infection requiring extraction. These data suggest that Watchman devices are extremely unlikely to become infected.