Back to Authors

McCollough, Cynthia H.

https://orcid.org/0000-0002-5346-332X

Mayo Clinic

Mayo Clinic

Citations 202

Targeted Imaging of Renal Fibrosis Using Antibody-Conjugated Gold Nanoparticles in Renal Artery Stenosis
Zhu, Xiang-Yang, Zou, Xiangyu , Yu, Zhicong , Ferguson, Christopher M. , Zhou, Wei , Lerman, Lilach O. , Zhou, Wei , Mukherjee, Rahul K , McCollough, Cynthia H.

Investigative Radiology | May 4, 2018 | Volume: 53 | Issue: 10 | Pages: 623-628

10.1097/rli.0000000000000476 Get It

Objectives The ability to determine the severity of renal fibrosis, which is involved in most chronic kidney diseases, may be beneficial for monitoring disease progression and management. The aim of this study was to assess a new method involving gold nanoparticles conjugated to an anti-collagen-I antibody (Co-I-AuNPs) as a computed tomography (CT) imaging contrast for the evaluation of renal fibrosis in situ. Materials and Methods Gold nanoparticles conjugated to an anti-collagen-I antibody were prepared using gold chloride reduction with sodium citrate and coated with polyethylene glycol (PEG), and their size was determined by electron microscopy and nanoparticle tracking analysis. Anti-collagen-I antibody was then conjugated to PEG-SH/COOH on the AuNP surface. The success of antibody conjugation was tested in vitro using collagen-coated plate and mouse stenotic kidney sections and in vivo using micro-CT and multidetector CT imaging. Results Bare AuNPs were 18.7 ± 0.6 nm and PEG-coated AuNPs were 45.3 ± 0.1 nm in size. In vitro, Co-I-AuNPs specifically bound to both a collagen-coated plate and mouse fibrotic kidneys. Furthermore, the stenotic mouse kidney showed increased Co-I-AuNPs retention compared with the contralateral kidney (59.3 ± 5.1 vs 45.1 ± 1.7 HU, P = 0.05), which correlated with its collagen deposition. Micro-CT also detected gold signals in situ in the Co-I-AuNP-injected kidney, which colocalized with histological trichrome staining. Conclusion Gold nanoparticles conjugated to an anti-collagen-I antibody are able to visualize kidney fibrosis in vitro and in situ and may be useful for nondestructive quantification of tissue fibrosis.
Imaging findings of mammary and systemic silicone deposition secondary to breast implants
Samreen, Naziya , Glazebrook, Katrina N. , Venkatesh, Sudhakar K. , McMenomy, Brendan P., Chandra, Anupam , Adler, Kalie , Bhatt, Asha, Adler, Kalie E, Venkatesh, Sudhakar K , Bhatt, Asha A. , Leng, Shuai , McCollough, Cynthia H.

The British Journal of Radiology | April 16, 2018 | Volume: No volume available | Issue: No issue available | Pages: 20180098

10.1259/bjr.20180098 Get It

Measuring arterial wall perfusion using photon-counting computed tomography (CT): improving CT number accuracy of artery wall using image deconvolution
Rajendran, Kishore , Jorgensen, Steven M., Anderson, Jill , Halaweish, Ahmed F., Abdurakhimova, Dilbar, Ritman, Erik L., Anderson, Jill L, McCollough, Cynthia H , Leng, Shuai , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | December 8, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.044006 Get It

CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection
Diehn, Felix E. , Michalak, Gregory J. , Kotsenas, Amy L. , Lindell, E. Paul , Halaweish, Ahmed F., DeLone, David R. , Campeau, Norbert G , Halaweish, Ahmed F , Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G. , Diehn, Felix E

Acta Radiologica Open | November 27, 2017 | Volume: 6 | Issue: 11 | Pages: 205846011774327

10.1177/2058460117743279 Get It

Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.
Phase-contrast imaging with a compact x-ray light source: system design
Sung, Yongjin , Gupta, Rajiv , Nelson, Brandon , Graves, W. , McCollough, Cynthia H , Leng, Shuai , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | November 23, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.043503 Get It

Low‐dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 Low Dose CT Grand Challenge
Bartley, Adam C. , Carter, Rickey E. , Chen, Baiyu , Drees, Tammy A., Edwards, Phillip K , Holmes, David R. , Huang, Alice E. , Khan, Farhana, McMillan, Kyle, Michalak, Gregory J. , Nunez, Kristina M., Yu, Lifeng , Edwards, Phillip, McMillan, Kyle L, Carter, Rickey E , McCollough, Cynthia H. , Leng, Shuai , Yu, Lifeng , Fletcher, Joel G.

Medical Physics | October 13, 2017 | Volume: 44 | Issue: 10 | Pages: No page available

10.1002/mp.12345 Get It

Purpose Using common datasets, to estimate and compare the diagnostic performance of image‐based denoising techniques or iterative reconstruction algorithms for the task of detecting hepatic metastases. Methods Datasets from contrast‐enhanced CT scans of the liver were provided to participants in an NIH ‐, AAPM ‐ and Mayo Clinic‐sponsored Low Dose CT Grand Challenge. Training data included full‐dose and quarter‐dose scans of the ACR CT accreditation phantom and 10 patient examinations; both images and projections were provided in the training data. Projection data were supplied in a vendor‐neutral standardized format ( DICOM ‐ CT ‐ PD ). Twenty quarter‐dose patient datasets were provided to each participant for testing the performance of their technique. Images were provided to sites intending to perform denoising in the image domain. Fully preprocessed projection data and statistical noise maps were provided to sites intending to perform iterative reconstruction. Upon return of the denoised or iteratively reconstructed quarter‐dose images, randomized, blinded evaluation of the cases was performed using a Latin Square study design by 11 senior radiology residents or fellows, who marked the locations of identified hepatic metastases. Markings were scored against reference locations of clinically or pathologically demonstrated metastases to determine a per‐lesion normalized score and a per‐case normalized score (a faculty abdominal radiologist established the reference location using clinical and pathological information). Scores increased for correct detections; scores decreased for missed or incorrect detections. The winner for the competition was the entry that produced the highest total score (mean of the per‐lesion and per‐case normalized score). Reader confidence was used to compute a Jackknife alternative free‐response receiver operating characteristic ( JAFROC ) figure of merit, which was used for breaking ties. Results 103 participants from 90 sites and 26 countries registered to participate. Training data were shared with 77 sites that completed the data sharing agreements. Subsequently, 41 sites downloaded the 20 test cases, which included only the 25% dose data ( CTDI vol = 3.0 ± 1.8 mG y, SSDE = 3.5 ± 1.3 mG y). 22 sites submitted results for evaluation. One site provided binary images and one site provided images with severe artifacts; cases from these sites were excluded from review and the participants removed from the challenge. The mean (range) per‐lesion and per‐case normalized scores were −24.2% (−75.8%, 3%) and 47% (10%, 70%), respectively. Compared to reader results for commercially reconstructed quarter‐dose images with no noise reduction, 11 of the 20 sites showed a numeric improvement in the mean JAFROC figure of merit. Notably two sites performed comparably to the reader results for full‐dose commercial images. The study was not designed for these comparisons, so wide confidence intervals surrounded these figures of merit and the results should be used only to motivate future testing. Conclusion Infrastructure and methodology were developed to rapidly estimate observer performance for liver metastasis detection in low‐dose CT examinations of the liver after either image‐based denoising or iterative reconstruction. The results demonstrated large differences in detection and classification performance between noise reduction methods, although the majority of methods provided some improvement in performance relative to the commercial quarter‐dose images with no noise reduction applied.
A comparison of relative proton stopping power measurements across patient size using dual- and single-energy CT
Michalak, Gregory J. , Taasti, Vicki Trier , Krauß, Bernhard , Deisher, A., Halaweish, Ahmed F., Deisher, Amanda, McCollough, Cynthia, McCollough, Cynthia H.

Acta Oncologica | September 8, 2017 | Volume: 56 | Issue: 11 | Pages: 1465-1471

10.1080/0284186x.2017.1372625 Get It

Estimation of signal and noise for a whole-body research photon-counting CT system
Li, Zhoubo , Yu, Zhicong , Kappler, S. , Leng, Shuai , McCollough, Cynthia H. , McCollough, Cynthia H , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | June 22, 2017 | Volume: 4 | Issue: 2 | Pages: 023505

10.1117/1.jmi.4.2.023505 Get It

Cochlear Implant Electrode Localization Using an Ultra-High Resolution Scan Mode on Conventional 64-Slice and New Generation 192-Slice Multi-Detector Computed Tomography
Carlson, Matthew L. , Witte, Robert J. , Krecke, Karl N. , Grimes, Josh, Koeller, Kelly K. , Bruesewitz, Michael R. , Lane, John I. , Leng, Shuai , Diehn, Felix E. , McCollough, Cynthia H.

Otology & Neurotology | May 31, 2017 | Volume: 38 | Issue: 7 | Pages: 978-984

10.1097/mao.0000000000001463 Get It

Hypothesis: A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Background: Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Methods: Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Results: Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. Conclusion: The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.
Correlation between a 2D channelized Hotelling observer and human observers in a low‐contrast detection task with multislice reading in CT
Yu, Lifeng , Chen, Baiyu , Kofler, James M., Favazza, Christopher , Kupinski, Matthew A. , Favazza, Christopher P, Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H.

Medical Physics | May 28, 2017 | Volume: 44 | Issue: 8 | Pages: 3990-3999

10.1002/mp.12380 Get It

PurposeModel observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e., multislice reading). The purpose of this study was to correlate human and model observer performance in a low‐contrast detection task performed using both 2D and multislice reading, and to determine if the 2D model observer still correlate well with human observer performance in multislice reading.MethodsA phantom containing 18 low‐contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192‐slice CT scanner at five dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered‐backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side‐by‐side with a signal‐absent VOI to create a 2‐alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multislice channelized Hotelling observer (CHO_MS), which integrates multislice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multislice viewing performance and the two CHO models.ResultsHuman observer performance was well correlated with the CHO_2D performance in the 2D viewing mode [Pearson product‐moment correlation coefficient R = 0.972, 95% confidence interval (CI): 0.919 to 0.990] and with the CHO_MS performance in the multislice viewing mode (R = 0.952, 95% CI: 0.865 to 0.984). The CHO_2D performance, calculated from the 2D viewing mode, also had a strong correlation with human observer performance in the multislice viewing mode (R = 0.957, 95% CI: 879 to 0.985). Human observer performance varied between the multislice and 2D modes. One reader performed better in the multislice mode (P = 0.013); whereas the other two readers showed no significant difference between the two viewing modes (P = 0.057 and P = 0.38).ConclusionsA 2D CHO model is highly correlated with human observer performance in detecting spherical low contrast objects in multislice viewing of CT images. This finding provides some evidence for the use of a simpler, 2D CHO to assess image quality in clinically relevant CT tasks where multislice viewing is used.