Patient‐reported quality of life and acceptance of the extravascular implantable cardioverter‐defibrillator: Results from pivotal study
Harrell, Rebecca , Crozier, Ian , Murgatroyd, Francis , Boersma, Lucas V.A. , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Birgersdotter‐Green, Ulrika , Wiggenhorn, Christopher, Hilleren, Gregory, Friedman, Paul A. , Sears, Samuel F , Harrell, Rebecca , Crozier, Ian , Boersma, Lucas , Manlucu, Jaimie , Friedman, Paul A , Knight, Bradley P , Sears, Samuel F.

Journal of Cardiovascular Electrophysiology | December 4, 2023 | Volume: 35 | Issue: 2 | Pages: 240-246

10.1111/jce.16151 Get It

Abstract Introduction The pivotal study of the extravascular implantable cardioverter‐defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient‐reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. Methods The EV ICD Pivotal Study was a prospective, single‐arm, nonrandomized, global, premarket approval trial. Patients completed the 12‐Item Short Form Survey (SF‐12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. Results From baseline to 6 months, patients within the EV ICD Pivotal Study ( n = 247) reported statistically significant SF‐12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV‐ICD or S‐ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S‐ICD and 73.0 ± 17.4, p = .004 for TV‐ICD). Conclusion The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6‐month follow‐up and markedly better overall acceptance of their ICD compared to a previous study with S‐ICD and TV‐ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.
Chronic safety and performance of the extravascular ICD: results from the global EV ICD Pivotal study
Friedman, Paul A. , Murgatroyd, Francis , Manlucu, Jaimie , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Wiggenhorn, Christopher, Boersma, Lucas V.A. , Knight, Bradley P. , Clémenty, Nicolas , Merkely, Béla , Chan, J Y S, Biffi, Mauro , Knops, Reinoud Elwin , Crozier, Ian

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.682 Get It

Abstract Background Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death in patients at high risk for ventricular arrhythmias, but conventional systems carry a risk of transvenous (TV) lead-related complications. The novel extravascular ICD (EV ICD) may reduce some of these complications, while offering anti-tachycardia pacing (ATP), pause prevention pacing, and a device of similar size and projected battery longevity as a TV ICD, by placing a lead substernally. The EV ICD Pivotal study demonstrated EV ICD safety and performance for termination of ventricular arrythmias at 6 months. Longer-term performance is unknown. Purpose To report the chronic safety and performance of the EV ICD system. Methods The extravascular implantable cardioverter defibrillator (EV ICD) Pivotal study was a prospective, international, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Freedom from major system- and/or procedure-related complications at 18 mo was evaluated, as well as conversion of arrhythmias by anti-tachycardia pacing (ATP) or shock through all available follow up. Rates of ATP success were evaluated using the generalized estimating equation (GEE) and simple proportions. Results Implantation was attempted in 316 patients: 74.7% male, age 53.8±13.1 years, 82% primary prevention, left ventricular ejection fraction of 38.9%±15.4%, and New York Heart Association Class I (23.4%) or II/III (65.5%). Of 299 implanted patients (average follow up 16.2±7.2 mo), 19 experienced 80 spontaneous, appropriately treated arrhythmic episodes: 37 treated by ATP, 15 by ATP and shock, and 28 by shock alone with a Kaplan-Meier (KM) estimated 6.8% of patients experiencing appropriate therapy by 18 mo (Figure). Of discrete episodes treated with shock, 21/21 (100%) were successfully terminated. ATP was delivered in 12 patients, successfully treating 35/52 episodes (67.3%; GEE adjusted 59.0%). Inappropriate shocks occurred in 35 patients through all follow up, with a rate of 10.2% at 1 year. The KM estimate of freedom from major EV ICD system-or procedure-related complications rate through 18 mo was 91.9% (95% CI: 88.2% to 94.4%). The most common event was lead dislodgment (10 events in 9 patients) identified 0 to 120 days post-implant, predominantly due to anchoring technique. Conclusion The safety and effectiveness of a novel EV ICD system with a substernal lead extends through chronic follow up. Shocks were avoided in nearly half of all spontaneous episodes because of the availability of ATP.Figure
Process mapping strategies to prevent subcutaneous implantable cardioverter‐defibrillator infections
Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , McClernon, Timothy R., Knight, Bradley P. , El-Chami, Mikhael F , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , Weiss, Raul , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Hansen, Linda K. , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | June 4, 2022 | Volume: 33 | Issue: 7 | Pages: 1628-1635

10.1111/jce.15566 Get It

AbstractBackgroundInfection remains a major complication of cardiac implantable electronic devices and can lead to significant morbidity and mortality. Implantable devices that avoid transvenous leads, such as the subcutaneous implantable cardioverter‐defibrillator (S‐ICD), can reduce the risk of serious infection‐related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S‐ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S‐ICD infections. Therefore, an expert panel was convened to develop a consensus on these topics.MethodsAn expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S‐ICD infections. Two face‐to‐face meetings of high‐volume S‐ICD implanters and an infectious diseases specialist, with expertise in cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre‐, peri‐, and postimplant to reduce S‐ICD infection risk.ResultsExpert panel consensus on recommended steps for patient preparation, S‐ICD implantation, and postoperative management was developed to provide guidance in individual patient management.ConclusionAchieving expert panel consensus by process mapping methodology for S‐ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S‐ICD infection.
Abstract 12087: Device-Related Infection Associated With Increased Mortality Risk in de novo Transvenous Implantable Cardioverter-Defibrillator Medicare Patients
Liu, Yiyan , Weiss, Raul, Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline, Lambiase, Pier D , El‐Chami, Mikhael F. , Griffiths, Robert, Knight, Bradley P. , Biffi, Mauro , Probst, Vincent , Jacobsen, Caroline M., Baddour, Larry M.

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.12087 Get It

Introduction: Device-related infection is estimated to occur in 1.9% of the Medicare patients with de novo transvenous (TV) implantable cardioverter-defibrillators (ICD) within 2 years post-implant. TV-ICD infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to expand on limited published data and assess mortality risk associated with TV-ICD infection in a large Medicare population with de novo TV-ICD implants. Methods: A survival analysis was conducted using 100% fee-for-service Medicare facility-level claims data to identify patients who underwent de novo TV-ICD implantation between 7/2016 and 1/2018. TV-ICD infection within 2 years of implantation was identified using ICD-10 and CPT codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time-dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias. Results: Among 26,742 Medicare patients with de novo TV-ICD, 518 (1.9%) had a device-related infection. The overall number of decedents was 4,721 (17.7%) over 2 years, with 4,555 (17%) in the non-infection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV-ICD infection was associated with an increase of 2.4 [95% CI: 2.08-2.85] times in the mortality hazard ratio (see attached Figure). Most of the baseline patient risk factors were also associated with higher risk of mortality in the Cox model. Conclusion: The rate of de novo TV-ICD infection and associated mortality in a large, real-world Medicare population is noteworthy. The positive association between device-related infection and risk of mortality further highlights the need to reduce infections.
The development of the extravascular defibrillator with substernal lead placement: A new Frontier for device‐based treatment of sudden cardiac arrest
Thompson, Amy , Atwater, Brett D. , Boersma, Lucas V.A. , Crozier, Ian , Engel, Gregory , Friedman, Paul A. , Gimbel, John , Knight, Bradley P. , Manlucu, Jaimie , Murgatroyd, Francis , O’Donnell, David , Kuschyk, Juergen , DeGroot, Paul, Thompson, Amy E , Friedman, Paul A , Knight, Bradley P , Boersma, Lucas , Crozier, Ian , Engel, Gregory

Journal of Cardiovascular Electrophysiology | April 28, 2022 | Volume: 33 | Issue: 6 | Pages: 1085-1095

10.1111/jce.15511 Get It

AbstractIntroductionThe extravascular implantable cardioverter‐defibrillator (EV ICD) system with substernal lead placement is a novel nontransvenous alternative to current commercially available ICD systems. The EV ICD provides defibrillation and pacing therapies without the potential long‐term complications of endovascular lead placement but requires a new procedure for implantation with a safety profile under evaluation.MethodsThis paper summarizes the development of the EV ICD, including the preclinical and clinical evaluations that have contributed to the system and procedural refinements to date.ResultsExtensive preclinical research evaluations and four human clinical studies with >140 combined acute and chronic implants have enabled the development and refinement of the EV ICD system, currently in worldwide pivotal study.ConclusionThe EV ICD may represent a clinically valuable solution in protecting patients from sudden cardiac death while avoiding the long‐term consequences of transvenous hardware. The EV ICD offers advantages over transvenous and subcutaneous systems by avoiding placement in the heart and vasculature; relative to subcutaneous systems, EV ICD requires less energy for defibrillation, enabling a smaller device, and provides pacing features such as antitachycardia and asystole pacing in a single system.
Device‐related infection associated with increased mortality risk in de novo transvenous implantable cardioverter‐defibrillator medicare patients
Liu, Yiyan , Griffiths, Robert I. , Knight, Bradley P. , Weiss, Raul , Mark, George E., Lambiase, Pier D. , Miller, Marc A. , Jacobsen, Caroline M., El-Chami, Mikhael F , Weiss, Raul , Miller, Marc A , Lambiase, Pier D , Knight, Bradley P , El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Baddour, Larry M.

Journal of Cardiovascular Electrophysiology | January 23, 2022 | Volume: 33 | Issue: 4 | Pages: 725-730

10.1111/jce.15385 Get It

AbstractIntroductionTransvenous implantable cardioverter‐defibrillators (TV‐ICD) infection is a serious complication that frequently requires complete device removal for attempted cure, which can be associated with patient morbidity and mortality. The objective of this study is to assess mortality risk associated with TV‐ICD infection in a large Medicare population with de novo TV‐ICD implants.MethodsA survival analysis was conducted using 100% fee‐for‐service Medicare facility‐level claims data to identify patients who underwent de novo TV‐ICD implantation between 7/2016 and 1/2018. TV‐ICD infection within 2 years of implantation was identified using International Classification of Disease, 10th Edition and current procedural terminology codes. Baseline patient risk factors associated with mortality were identified using the Charlson Comorbidity Index categories. Infection was treated as a time‐dependent variable in a multivariate Cox proportional hazards model to account for immortal time bias.ResultsAmong 26,742 Medicare patients with de novo TV‐ICD, 518 (1.9%) had a device‐related infection. The overall number of decedents was 4721 (17.7%) over 2 years, with 4555 (17%) in the noninfection group and 166 (32%) in the infection group. After adjusting for baseline patient demographic characteristics and various comorbidities, the presence of TV‐ICD infection was associated with an increase of 2.4 (95% CI: 2.08–2.85) times in the mortality hazard ratio.ConclusionThe rate of TV‐ICD infection and associated mortality in a large, real‐world Medicare population is noteworthy. The positive association between device‐related infection and risk of mortality further highlights the need to reduce infections
Process Mapping Strategies to Prevent Subcutaneous Implantable Cardioverter-Defibrillator Infection
Weiss, Raul , Mark, G. J., Miller, Marc A. , McClernon, Timothy R., Weiss, Raul , Mark, George, El‐Chami, Mikhael F. , Biffi, Mauro , Probst, Vincent , Lambiase, Pier D. , Hansen, Linda, Knight, Bradley P. , Baddour, Larry M.

No container title available | January 2, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.164118494.47265902/v1 Get It

Background: Infection remains a major complication of cardiac implantable electronic devices (CIEDs) and can lead to significant morbidity and mortality. Extrathoracic devices that avoid epicardial or transvenous leads, such as the subcutaneous implantable cardioverter-defibrillator (S-ICD), can reduce the risk of serious infection-related complications, such as bloodstream infection and infective endocarditis. While the 2017 AHA/ACC/HRS guidelines include recommendations for S-ICD use for patients at high risk of infection, currently, there are no clinical trial data that address best practices for the prevention of S-ICD infections. Therefore, an expert panel was convened to develop consensus on these topics. Methods: An expert process mapping methodology was used to achieve consensus on the appropriate steps to minimize or prevent S-ICD infections. Two face-to-face meetings of high-volume S-ICD implanters and an infectious diseases specialist, with expertise on cardiovascular implantable electronic device infections, were conducted to develop consensus on useful strategies pre-, peri-, and post-implant to reduce S-ICD infection risk. Results: Expert panel consensus of recommended steps for patient preparation, S-ICD implantation, and post-operative management were developed to provide guidance in individual patient management. Conclusion: Achieving expert panel consensus by process mapping methodology for S-ICD infection prevention was attainable, and the results should be helpful to clinicians in adopting interventions to minimize risks of S-ICD infection.
Cover Image, Volume 32, Issue 11
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , Knight, Bradley P , Tzou, Wendy , Schaller, Robert D. , McLeod, Christopher J. , Natale, Andrea

Journal of Cardiovascular Electrophysiology | November 6, 2021 | Volume: 32 | Issue: 11 | Pages: No page available

10.1111/jce.15283 Get It

Evaluation of a novel cardiac signal processing system for electrophysiology procedures: The PURE EP 2.0 study
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , McLeod, Christopher , Natale, Andrea , Knight, Bradley P , Tzou, Wendy , Yasin, Omar , Padmanabhan, Deepak , Natale, Andrea , Schaller, Robert D. , McLeod, Christopher

Journal of Cardiovascular Electrophysiology | September 23, 2021 | Volume: 32 | Issue: 11 | Pages: 2915-2922

10.1111/jce.15250 Get It

AbstractBackgroundIntracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades.ObjectiveThe purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi‐center, prospective study.MethodsIntracardiac signal data of clinical interest were collected from 51 patients undergoing ablation procedures with PURE, the signal recording system, and the 3D mapping system at the same time stamps. The samples were randomized and subjected to blinded, controlled evaluation by three independent electrophysiologists to determine the overall quality and clinical utility of PURE signals when compared to conventional sources. Each reviewer assessed the same (92) signal sample sets and responded to (235) questions using a 10‐point rating scale. If two or more reviewers rated the PURE signal higher than the control, it was deemed superior.ResultsA total of 93% of question responses showed consensus amongst the blinded reviewers. Based on the ratings for each pair of signals, a cumulative total of 164 PURE signals out of 218 (75.2%) were statistically rated as Superior for this data set (p < .001). Only 14 PURE signals out of 218 were rated as Inferior (6.4%).ConclusionThe PURE intracardiac signals were statistically rated as superior when compared to conventional systems.