Objective: To evaluate the function and safety of the SteadiSet™ infusion set over a continuous 7-day wear period in adults with type 1 diabetes. Research Design and Methods: Participants used a SteadiSet infusion set with a t:slim X2™ insulin pump with Control-IQ™ technology, and either insulin aspart or insulin lispro, for a target of 7 days for 12 consecutive wear periods. Each set removed before 7 days was adjudicated by an independent committee to assess the cause of early removal and to determine whether criteria for primary or key secondary endpoints were met. Results: There were 260 participants who inserted 3028 infusion sets. For the primary endpoint, the Kaplan–Meier 7-day survival estimate was 95% (95% CI 94% to 96%). For the key secondary endpoint, which expanded the reasons for a failed infusion set, the Kaplan–Meier 7-day survival estimate was 84% (95% CI 82% to 86%). For both endpoints, the P value was <0.001 compared with a prespecified survival rate of 75%. Time-in-range 70–180 mg/dL (TIR) increased through day 3 of set wear and then decreased through day 7, with the average TIR being 70.6% over the entire wear period across all infusion sets, including those that failed. An increase in total daily insulin was observed from day 4 through day 7. Conclusions: The 7-day survival of the SteadiSet infusion set was very high for the primary endpoint and at an acceptable level with respect to early removal for any reason related to the device.
Adults With Type 2 Diabetes Benefit From Automated Insulin Delivery Irrespective of C-Peptide Level
OBJECTIVE The Centers for Medicare & Medicaid Services (CMS) requires a low C-peptide level for insulin pump coverage unless the individual is β-cell autoantibody positive, which precludes coverage of automated insulin delivery (AID) systems for many people with type 2 diabetes. RESEARCH DESIGN AND METHODS In the Randomized Trial Evaluating the Efficacy and Safety of Control-IQ+ Technology in Adults With Type 2 Diabetes Using Basal-Bolus Insulin Therapy study evaluating the t:slim X2 insulin pump with Control-IQ+ technology, adults with insulin-treated type 2 diabetes were categorized into high C-peptide (n = 195) and low C-peptide (n = 59) groups based on CMS criteria. RESULTS In the AID group, mean HbA1c decreased from baseline by 0.8%, which was significantly greater than in the control group with both high (P < 0.001) and low (P = 0.02) C-peptide levels. Results were similar in participants ≥65 years old. CONCLUSIONS The benefit of AID is present with high and low C-peptide levels. Thus, requiring a low C-peptide level as a prerequisite for AID therapy is not warranted.
A Randomized Trial of Automated Insulin Delivery in Type 2 Diabetes
Abstract INTRODUCTION Cognition is reduced at low and high glucose, reflecting cognitive vulnerability to glucose (CVG) fluctuations. The impact of glucose fluctuations on the aging brain remains unclear. We examined whether CVG is associated with plasma biomarkers of Alzheimer's disease (AD) pathology and neurodegeneration. METHODS Participants included N = 114 adults with type 1 diabetes assessed for processing speed and sustained attention using ecological momentary assessment (EMA) combined with continuous glucose monitoring (CGM). We characterized associations between CVG and amyloid beta (Aβ) 42/40, phosphorylated tau (p‐tau) 181 and 217, neurofilament light chain, and glial fibrillary acidic protein. RESULTS CVG was associated with all plasma biomarkers, except Aβ 42/40. CVG for sustained attention exhibited strong associations with p‐tau biomarkers that persisted across covariate specifications. DISCUSSION CVG may be a useful digital phenotype of AD. It remains unclear whether CVG contributes to versus arises from neurodegeneration. We consider possible mechanisms linking cognitive vulnerability and long‐term glucose variability to the development of neuropathology. Highlights Cognitive vulnerability to glucose (CVG) may be a useful digital phenotype of neurodegeneration. We used cognitive ecological momentary assessment and continuous glucose monitoring to investigate CVG's associations with plasma biomarkers. Associations of CVG for sustained attention and phosphorylated tau 181 remained significant across covariates. We discuss possible mechanisms relating glucose variability, cognition, and neurodegeneration.
Automated Insulin Delivery in Older Adults with Type 1 Diabetes
OBJECTIVE To evaluate a regimen of inhaled Technosphere insulin (TI) plus insulin degludec in adults with type 1 diabetes, who prestudy were predominately using either an automated insulin delivery (AID) system or multiple daily insulin injections (MDI) with continuous glucose monitoring. RESEARCH DESIGN AND METHODS At 19 sites, adults with type 1 diabetes were randomly assigned to TI plus insulin degludec (N = 62) or usual care (UC) with continuation of prestudy insulin delivery method (N = 61) for 17 weeks. RESULTS Prestudy, AID was used by 48% and MDI by 45%. Mean ± SD HbA1c was 7.57% ± 0.97% at baseline and 7.62% ± 1.06% at 17 weeks in the TI group and 7.59% ± 0.80% and 7.54% ± 0.77%, respectively, in the UC group (adjusted difference 0.11%, 95% CI −0.10 to 0.33, P value for noninferiority = 0.01). HbA1c improved from baseline to 17 weeks by >0.5% (5.5 mmol/mol) in 12 (21%) in the TI group and in 3 (5%) in the UC group and worsened by >0.5% (5.5 mmol/mol) in 15 (26%) in the TI group and in 2 (3%) in the UC group. The most common TI side effect was a brief cough; eight participants discontinued TI due to side effects. CONCLUSIONS In adults with type 1 diabetes, HbA1c after 17 weeks with a regimen of TI and degludec was noninferior to UC, which consisted predominately of either AID or MDI. TI should be considered an option for people with type 1 diabetes, particularly those who are motivated to further reduce postprandial hyperglycemia.
A Randomized Comparison of Postprandial Glucose Excursion Using Inhaled Insulin Versus Rapid-Acting Analog Insulin in Adults With Type 1 Diabetes Using Multiple Daily Injections of Insulin or Automated Insulin Delivery
OBJECTIVE To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.
Improved Glycemia with Hybrid Closed-Loop Versus Continuous Subcutaneous Insulin Infusion Therapy: Results from a Randomized Controlled Trial