Citations

Mayo Clinic

Clear

1172 citation(s) found for "Ma, Cynthia".

P472 Efficacy of intravenous ustekinumab re-induction in patients with Crohn’s disease with a loss of response
Heron, Valérie , Panaccione, Nicola, Candido, Kristen, Bitton, Alain , Seow, Cynthia H. , Afif, Waqqas , Bessissow, Talat , Panaccione, Remo

Journal of Crohn's and Colitis | January 25, 2019 | Volume: 13 | Issue: Supplement_1 | Pages: S347-S348

10.1093/ecco-jcc/jjy222.596 Get It

Frequency and predictors of the potential overprescribing of antidepressants in elderly residents of a geographically defined U.S. population
Bobo, William V. , Leung, Jonathan G. , Stoppel, Cynthia , Hoel, Robert W. , Chang, Zheng , Lachner, Christian , Chauhan, Mohit , Flowers, L, Brue, Scott M., Frye, Mark A. , Sauver, Jennifer L. St. , Rocca, Walter A. , Sutor, Bruce, Grossardt, Brandon R. , Takahashi, Paul Y. , Flowers, Lee, St Sauver, Jennifer, Leung, Jonathan G , V Bobo, William , St Sauver, Jennifer L , Lapid, Maria I. , Chauhan, Mohit

Pharmacology Research & Perspectives | January 24, 2019 | Volume: 7 | Issue: 1 | Pages: No page available

10.1002/prp2.461 | PMID 30693088 Get It

AbstractThe purpose of this study was to estimate the extent of potential antidepressant overprescribing in a geographically defined U.S. population, and to determine the indications and factors that account for it. We conducted a cohort study of new antidepressant prescriptions for elderly residents of Olmsted County, Minnesota, 2005‐2012, using the Rochester Epidemiology Project medical records‐linkage system. Indications for antidepressants were abstracted from health records for all cohort members. Potential antidepressant overprescribing was defined based on regulatory approval, the level of evidence identified from a standardized drug information database, and multidisciplinary expert review. Predictors of potential antidepressant overprescribing were investigated using logistic regression models, stratified by general antidepressant indication (general medical indication, specific psychiatric diagnosis, and non‐specific psychiatric symptoms). Potential antidepressant overprescribing occurred in 24% of 3199 incident antidepressant prescriptions during the study period, and involved primarily newer antidepressants that were prescribed for non‐specific psychiatric symptoms and subthreshold diagnoses. Potential antidepressant overprescribing was associated with nursing home residence, having a higher number of comorbid medical conditions and outpatient prescribers, taking more concomitant medications, having greater use of urgent or acute care services in the year preceding the index antidepressant prescription, and being prescribed antidepressants via telephone, e‐mail, or patient portal. In conclusion, potential antidepressant overprescribing occurred in elderly persons and involved mainly newer antidepressants used for non‐specific psychiatric symptoms and subthreshold diagnoses, and was associated with indicators of higher clinical complexity or severity and with prescribing without face‐to‐face patient contact.
Response to Weisschuh’s “Comment: a novel missense mutation in BEST1 associated with an autosomal-dominant vitreoretinochoroidopathy (ADVIRC) phenotype”
Mano, Fukutaro , Pfannkoch, Cynthia, Olsen, Timothy W. , Marmorstein, Alan D. , Pulido, José S. , LoBue, Stephen A , Marmorstein, Alan D

Ophthalmic Genetics | January 11, 2019 | Volume: 40 | Issue: 1 | Pages: 88-89

10.1080/13816810.2018.1558264 | PMID 30632873 Get It

Safety of Sports for Young Patients With Implantable Cardioverter-Defibrillators
Saarel, Elizabeth V. , Law, Ian H. , Berul, Charles I. , Ackerman, Michael J. , Kanter, Ronald J. , Sanatani, Shubhayan , Berger, Stuart, Fischbach, Peter , Dziura, James , Simone, Laura, Olshansky, Brian , Cannom, David S. , Lampert, Rachel , Sanatani, Shubhayan , Olshansky, Brian , Law, Ian H , Burton, David A., Brandt, Cynthia , Li, Fangyong

Circulation: Arrhythmia and Electrophysiology | January 7, 2019 | Volume: 11 | Issue: 11 | Pages: No page available

10.1161/circep.118.006305 | PMID 30520349 Get It

Background: Despite safety concerns, many young patients with implantable cardioverter-defibrillators (ICDs) participate in sports. We undertook a prospective, multinational registry to determine the incidence of serious adverse events because of sports participation. The primary end points were death or resuscitated arrest during sports or injury during sports because of arrhythmia or shock. Secondary end points included system malfunction and incidence of ventricular arrhythmias requiring multiple shocks for termination. Methods: Athletes with ICDs aged ≤21 years were included in this post hoc subanalysis of the ICD Sports Registry. Data on sports and clinical outcomes were obtained by phone interview and medical records review. ICD shocks and clinical details of lead malfunction were classified by 2 electrophysiologists. Results: A total of 129 young athletes participating in competitive (n=117) or dangerous (n=12) sports were enrolled. The mean age was 16 years (range, 10–21; 40% female; 92% white). The most common diagnoses were long QT syndrome (n=49), hypertrophic cardiomyopathy (n=30), and congenital heart disease (n=16). The most common sports were basketball and soccer, including 79 varsity/junior varsity high school and college athletes. During a median follow-up of 42 months, 35 athletes (27%) received 38 shocks. There were no occurrences of death, arrest, or injury related to arrhythmia, during sports. There was 1 ventricular tachycardia/ventricular fibrillation storm during competition. Freedom from lead malfunction was 92.3% at 5 years and 79.6% at 10 years. Conclusions: Although shocks related to competition/practice are not uncommon, there were no serious adverse sequelae. Lead malfunction rates were similar to previously reported in unselected pediatric ICD populations. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00637754.
Phase II trial of single agent PARP inhibitor ABT-888 (veliparib [vel]) followed by postprogression therapy of vel with carboplatin (carb) in patients (pts) with stage BRCA-associated metastatic breast cancer (MBC): California Cancer Consortium trial PHII-
Somlo, George, Frankel, Paul , Luu, Thehang, Cynthia, X. , García, Agustin A. , Cigler, Tessa, Cream, Leah, Harvey, Harold A., Nanda, Rita , Chew, Helen K. , Moynihan, Timothy J. , Hurria, Arti , Chen, Alice P. , Arun, Banu , Sparano, Joseph A. , Vahdat, Linda T. , Goetz, Matthew P. , Mortimer, Joanne , Gandara, David R. , Weitzel, Jeffrey N.

Journal of Clinical Oncology | January 3, 2019 | Volume: 32 | Issue: 15_suppl | Pages: 1021-1021

10.1200/jco.2014.32.15_suppl.1021 Get It

Analyzing the efficacy and safety of immunotherapy in pancreatic ductal adenocarcinoma (PDA): A systematic review and meta-analysis.
Zahid, Umar, Scott, Aaron J. , Elliott, Cynthia M, Boiles, Alejandro Recio, Elquza, Emad , Mahadevan, Daruka , Babiker, Hani M. , Howe, Carol , Riaz, Irbaz Bin , Acharya, Utkarsh

Journal of Clinical Oncology | January 2, 2019 | Volume: 36 | Issue: 4_suppl | Pages: 512-512

10.1200/jco.2018.36.4_suppl.512 Get It

512 Background: The tumor microenvironment in PDA is heterogeneous and immunosuppressive given the presence of regulatory T cells and exhausted effector T cells. Despite the upsurge of effective immunotherapeutic agents (IA) in other tumor types, the role in PDA remains unknown. We conducted a meta-analysis of IA in PDA. Methods: Following PRISMA guidelines, we searched PubMed/MEDLINE, Elsevier/Embase, Wiley/Cochrane Library and ClinicalTrials.gov. Articles were selected per the following criteria: (1) Study participants had a diagnosis of PDA; (2) An IA was used in the trial. Titles, abstracts and full text articles were reviewed by 2 independent reviewers; disagreements were resolved by a third. Data extraction and analysis were performed by 3 independent reviewers. Descriptive analysis, mean, median, confidence interval and forest plots were used for statistical analysis. Results: We found 20,792 studies through the database, 16,105 remained after duplicates were removed and 15,889 were excluded due to irrelevance. Strict inclusion criteria were applied to the full text of 216 articles. The most common reason for exclusion were conference abstracts (44%) and ongoing trials (16%). Fifty-four trials (39 metastatic (met), 12 adjuvant (Ad) and 3 neoadjuvant (nAd) met criteria for further analysis. Age range was 27-86 (median 61) and 52.3% were males. IA included cytokine therapy (33%), peptide vaccines (22%), dendritic cell vaccine (13%), oncolytic viruses (9%), CTLA-4 inhibitors (2%) and others. IA in met-PDA had a median overall survival (mOS) of 8.1 months (ms) and a disease control rate (DCR) of 55.4% (95% CI, 51.85-58.95). There was no statistical difference in DCR among IA subtypes (range 49-60%) (p = 0.22). The mOS of Ad-PDA trials was 25 ms (historically comparable to gemcitabine, p = 0.75) and 18 ms for nAd-PDA. The most common Gr1/2 toxicities were skin reactions, fever, and chills and Gr3/4 were cytopenias, diarrhea, and mucositis. One death occurred due to neutropenic sepsis. Conclusions: IA demonstrates modest efficacy in the treatment of met-PDA albeit exhibits a favorable toxicity profile. Many trial results are available only in abstract format and some are ongoing.
Computed Tomography Technology—and Dose—in the 21st Century
McCollough, Cynthia H.

Health Physics | December 24, 2018 | Volume: 116 | Issue: 2 | Pages: 157-162

10.1097/hp.0000000000000997 | PMID 30585957 Get It

AbstractIn the last decade or so, a number of disruptive technological advances have taken place in x-ray computed tomography, making possible new clinical applications. Changes in scanner design have included the use of two x-ray sources and two detectors or the use of large detector arrays that provide 16 cm of longitudinal coverage in one gantry rotation. These advances have allowed images of the entire heart to be acquired in just one heartbeat, lowering the effective dose from cardiac computed tomography from ~15 mSv to <1 mSv. Dual-energy computed tomography is now in widespread clinical use, enabling the assessment of material composition and concentration, as well as a range of new clinical applications. An emerging technology known as photon-counting detector computed tomography directly measures the energies of detected photons and is capable of simultaneously acquiring more than two energy data sets. Photon-counting detector computed tomography also provides advantages such as the ability to reject electronic noise, better iodine contrast-to-noise for a given dose, and spatial resolution as fine as 150 μm. Optimized x-ray tube potential selection has allowed reduction in radiation and contrast doses. Finally, wide adoption of iterative reconstruction and noise-reduction techniques has occurred. In all, body computed tomography doses have fallen dramatically, for example, by over a factor of 3 from the early 1980s. All of these advances increase the medical benefit and decrease the potential radiation risk associated with computed tomography. However, care must be taken to ensure that doses are not lowered to the level at which the clinical task is compromised.
Estimating a size‐specific dose for helical head CT examinations using Monte Carlo simulation methods
Hardy, Anthony J. , Bostani, Maryam, Hernandez, Andrew M. , Zankl, M. , Cagnon, Chris H., Boone, John M. , McCollough, Cynthia, McCollough, Cynthia H. , McNitt‐Gray, Michael F.

Medical Physics | December 19, 2018 | Volume: 46 | Issue: 2 | Pages: 902-912

10.1002/mp.13301 | PMID 30565704 Get It

PurposeSize‐specific dose estimates (SSDE) conversion factors have been determined byAAPMReport 204 to adjustCTDIvolto account for patient size but were limited to bodyCTexaminations. The purpose of this work was to determine conversion factors that could be used for anSSDEfor helical, headCTexaminations for patients of different sizes.MethodsValidated Monte Carlo (MC) simulation methods were used to estimate dose to the center of the scan volume from a routine, helical head examination for a group of patient models representing a range of ages and sizes. Ten GSF/ICRP voxelized phantom models and five pediatric voxelized patient models created from CT image data were used in this study. CT scans were simulated using a Siemens multidetector row CT equivalent source model. Scan parameters were taken from the AAPM Routine Head protocols for a fixed tube current (FTC), helical protocol, and scan lengths were adapted to the anatomy of each patient model. MC simulations were performed using mesh tallies to produce voxelized dose distributions for the entire scan volume of each model. Three tally regions were investigated: (1) a small 0.6 cc volume at the center of the scan volume, (2) 0.8–1.0 cm axial slab at the center of the scan volume, and (3) the entire scan volume. Mean dose to brain parenchyma for all three regions was calculated. Mean bone dose and a mass‐weighted average dose, consisting of brain parenchyma and bone, were also calculated for the slab in the central plane and the entire scan volume. All dose measures were then normalized by CTDIvolfor the 16 cm phantom (CTDIvol,16). Conversion factors were determined by calculating the relationship between normalized doses and water equivalent diameter (Dw).ResultsCTDIvol,16‐normalized mean brain parenchyma dose values within the 0.6 cc volume, 0.8–1.0 cm central axial slab, and the entire scan volume, when parameterized byDw, had an exponential relationship with a coefficient of determination (R2) of 0.86, 0.84, and 0.88, respectively. There was no statistically significant difference between the conversion factors resulting from these three different tally regions. Exponential relationships between CTDIvol,16‐normalized mean bone doses hadR2values of 0.83 and 0.87 for the central slab and for the entire scan volume, respectively. CTDIvol,16‐normalized mass‐weighted average doses hadR2values of 0.39 and 0.51 for the central slab and for the entire scan volume, respectively.ConclusionsConversion factors that describe the exponential relationship between CTDIvol,16‐normalized mean brain dose and a size metric (Dw) for helical head CT examinations have been reported for two different interpretations of the center of the scan volume. These dose descriptors have been extended to describe the dose to bone in the center of the scan volume as well as a mass‐weighted average dose to brain and bone. These may be used, when combined with other efforts, to develop an SSDE dose coefficients for routine, helical head CT examinations.
Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
Zhou, Wei , Bartlett, David J. , Glazebrook, Katrina N. , Carter, Rickey E. , Zhou, Wei , Carter, Rickey E , Diehn, Felix E. , Kotsenas, Amy L. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Investigative Radiology | December 18, 2018 | Volume: 54 | Issue: 4 | Pages: 204-211

10.1097/rli.0000000000000535 | PMID 30562270 Get It

Objectives The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. Materials and Methods A 3D-printed spine with pedicle screws was scanned on a PCD-CT system with and without tin filtration. Image noise and severity of artifacts were measured for low-energy threshold (TL) and TH images. In a prospective, institutional review board–approved, Health Insurance Portability and Accountability Act-compliant study, 20 patients having a clinical energy-integrating detector (EID) CT were scanned on a PCD-CT system using tin filtration. Images were reviewed by 3 radiologists to evaluate visualization of anatomic structures, diagnostic confidence, and image preference. Artifact severity and image noise were measured. Wilcoxon signed rank was used to test differences between PCD-CT TH and EID-CT images. Results Phantom TH images with tin filtration reduced metal artifacts and had comparable noise (32 HU) to TL images (29 HU) acquired without tin filtration. Visualization scores for the cortex, trabeculae, and implant-trabecular interface from PCD-CT TH images (4.4 ± 0.9, 4.4 ± 1.0, and 4.4 ± 1.0) were significantly higher (P < 0.0001) than EID-CT images (3.3 ± 1.3, 3.3 ± 1.2, and 3.3 ± 1.6). A strong preference was shown for PCD-CT TH images due to improved diagnostic confidence and decreased artifact severity. Noise in PCD-CT TH images (93 ± 41 HU) was significantly lower than that in EID-CT images (133 ± 92 HU, P < 0.05). Conclusions Threshold high images acquired with tin filtration on PCD-CT demonstrated a substantial decrease in metal artifacts and an increase in dose efficiency compared with EID-CT.
Clinical Assessment of Metal Artifact Reduction Methods in Dual-Energy CT Examinations of Instrumented Spines
Long, Zaiyang , Nagelschneider, Alex A. , Michalak, Gregory J. , Yu, Lifeng , DeLone, David R. , Kotsenas, Amy L. , Lehman, Vance T. , Fletcher, Joel G. , McCollough, Cynthia H. , Yu, Lifeng

American Journal of Roentgenology | December 12, 2018 | Volume: 212 | Issue: 2 | Pages: 395-401

10.2214/ajr.18.19757 | PMID 30667317 Get It