Citations

Mayo Clinic

Clear

188 citation(s) found for "Huston, J".

Does the Poly (ADP-Ribose) Polymerase Inhibitor Veliparib Merit Further Study for Cancer-Associated Weight Loss? Observations and Conclusions from Sixty Prospectively Treated Patients
Doles, Jason D. , Hogan, Kelly A. , O’Connor, Jennifer M. , Hendrickson, Andrea E. Wahner , Huston, Olivia, Jatoi, Aminah , O'Connor, Jennifer, Wahner Hendrickson, Andrea E, Doles, Jason D

Journal of Palliative Medicine | May 24, 2018 | Volume: 21 | Issue: 9 | Pages: 1334-1338

10.1089/jpm.2018.0023 | PMID 29792535 Get It

In vivo characterization of 3D skull and brain motion during dynamic head vibration using magnetic resonance elastography
Yin, Ziying , Sui, Yi , Trzasko, Joshua D. , Rossman, Phillip J. , Manduca, Armando , Ehman, Richard L. , Huston, John , Sui, Yi , Yin, Ziying

Magnetic Resonance in Medicine | May 18, 2018 | Volume: 80 | Issue: 6 | Pages: 2573-2585

10.1002/mrm.27347 | PMID 29774594 Get It

PurposeTo introduce newly developed MR elastography (MRE)‐based dual‐saturation imaging and dual‐sensitivity motion encoding schemes to directly measure in vivo skull–brain motion, and to study the skull–brain coupling in volunteers with these approaches.MethodsSix volunteers were scanned with a high‐performance compact 3T‐MRI scanner. The skull–brain MRE images were obtained with a dual‐saturation imaging where the skull and brain motion were acquired with fat‐ and water‐suppression scans, respectively. A dual‐sensitivity motion encoding scheme was applied to estimate the heavily wrapped phase in skull by the simultaneous acquisition of both low‐ and high‐sensitivity phase during a single MRE exam. The low‐sensitivity phase was used to guide unwrapping of the high‐sensitivity phase. The amplitude and temporal phase delay of the rigid‐body motion between the skull and brain was measured, and the skull–brain interface was visualized by slip interface imaging (SII).ResultsBoth skull and brain motion can be successfully acquired and unwrapped. The skull–brain motion analysis demonstrated the motion transmission from the skull to the brain is attenuated in amplitude and delayed. However, this attenuation (%) and delay (rad) were considerably greater with rotation (59 ± 7%, 0.68 ± 0.14 rad) than with translation (92 ± 5%, 0.04 ± 0.02 rad). With SII the skull–brain slip interface was not completely evident, and the slip pattern was spatially heterogeneous.ConclusionThis study provides a framework for acquiring in vivo voxel‐based skull and brain displacement using MRE that can be used to characterize the skull–brain coupling system for understanding of mechanical brain protection mechanisms, which has potential to facilitate risk management for future injury.
Lightweight, compact, and high‐performance 3T MR system for imaging the brain and extremities
Foo, Thomas , Laskaris, E.T., Vermilyea, Mark, Xu, Minfeng , Thompson, Paul, Conte, Gene, Epps, Christopher Van, Immer, Christopher, Tan, Ek T. , Graziani, Dominic, Mathieu, Jean‐Baptise, Hardy, Christopher J., Schenck, John F., Fiveland, Eric, Stautner, Wolfgang , Ricci, Justin, Piel, Joseph E., Park, Keith, Hua, Yihe , Bai, Ye , Kagan, Alex, Stanley, David A. , Weavers, Paul T., Gray, Erin M. , Shu, Yunhong , Frick, Matthew A., Trzasko, Joshua D. , Foo, Thomas K F , Tan, Ek T , Gray, Erin, Trzasko, Joshua, Bernstein, Matt A , Thompson, Paul, Epps, Chris Van, Lee, Seung‐Kyun , Campeau, Norbert G. , Huston, John , Bernstein, Matt A.

Magnetic Resonance in Medicine | March 15, 2018 | Volume: 80 | Issue: 5 | Pages: 2232-2245

10.1002/mrm.27175 | PMID 29536587 Get It

PurposeTo build and evaluate a small‐footprint, lightweight, high‐performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole‐body clinical 3T MRI scanners, while achieving substantial reductions in installation costs.MethodsA conduction‐cooled magnet was developed that uses less than 12 liters of liquid helium in a gas‐charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42‐cm inner‐diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet‐gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80‐mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1‐MVA gradient drivers.ResultsIn a comparison of anatomical imaging in 16 patients using T2‐weighted 3D fluid‐attenuated inversion recovery (FLAIR) between the compact 3T and whole‐body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80‐mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain.ConclusionsThe compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole‐body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.
Accuracy of detecting enlargement of aneurysms using different MRI modalities and measurement protocols
Nakagawa, Daichi , Nagahama, Yasunori , Policeni, Bruno , Raghavan, Madhavan L. , Dillard, Seth, Schumacher, Anna , Sarathy, Srivats, Wilson, Saul, Allan, Lauren , Woo, Henry H. , Cloft, Harry J. , Torner, James C., Brown, Robert D., Torner, James C. , Dlouhy, Brian J , Huston, John , Wintermark, Max , Hasan, David

Journal of Neurosurgery | March 9, 2018 | Volume: 130 | Issue: 2 | Pages: 559-565

10.3171/2017.9.jns171811 | PMID 29521585 Get It

OBJECTIVEAneurysm growth is considered predictive of future rupture of intracranial aneurysms. However, how accurately neuroradiologists can reliably detect incremental aneurysm growth using clinical MRI is still unknown. The purpose of this study was to assess the agreement rate of detecting aneurysm enlargement employing generally used MRI modalities.METHODSThree silicone flow phantom models, each with 8 aneurysms of various sizes at different sites, were used in this study. The aneurysm models were identical except for an incremental increase in the sizes of the 8 aneurysms, which ranged from 0.4 mm to 2 mm. The phantoms were imaged on 1.5-T and 3-T MRI units with both time-of-flight (TOF) and contrast-enhanced MR angiography. Three independent expert neuroradiologists measured the aneurysms in a blinded manner using different measurement approaches. The individual and agreement detection rates of aneurysm enlargement among the 3 experts were calculated.RESULTSThe mean detection rate of any increase in any aneurysmal dimension was 95.7%. The detection rates of the 3 observers (observers A, B, and C) were 98.0%, 96.6%, and 92.7%, respectively (p = 0.22). The detection rates of each MRI modality were 91.3% using 1.5-T TOF, 97.2% using 1.5-T with Gd, 95.8% using 3.0-T TOF, and 97.2% using 3.0-T with Gd (p = 0.31). On the other hand, the mean detection rate for aneurysm enlargement was 54.8%. Specifically, the detection rates of observers A, B, and C were 49.0%, 46.1%, and 66.7%, respectively (p = 0.009). As the incremental enlargement value increased, the detection rate for aneurysm enlargement increased. The use of 1.5-T Gd improved the detection rate for small incremental enlargement (e.g., 0.4–1 mm) of the aneurysm (p = 0.04). The location of the aneurysm also affected the detection rate for aneurysm enlargement (p < 0.0001).CONCLUSIONSThe detection rate and interobserver agreement were very high for aneurysm enlargement of 0.4–2 mm. The detection rate for at least 1 increase in any aneurysm dimension did not depend on the choice of MRI modality or measurement protocol. Use of Gd improved the accuracy of measurement. Aneurysm location may influence the accuracy of detecting enlargement.
Time‐resolved contrast‐enhanced MR angiography with single‐echo Dixon fat suppression
Stinson, Eric G. , Trzasko, Joshua D. , Glockner, James F., Young, Phillip M. , Riederer, Stephen J. , Campeau, Norbert G. , Huston, John

Magnetic Resonance in Medicine | February 28, 2018 | Volume: 80 | Issue: 4 | Pages: 1556-1567

10.1002/mrm.27152 | PMID 29488251 Get It

PurposeDixon‐based fat suppression has recently gained interest for dynamic contrast‐enhanced MRI, but multi‐echo techniques require longer scan times and reduce temporal resolution compared to single‐echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single‐echo Dixon imaging with high spatial and temporal resolution.Theory and MethodsReal‐valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat‐water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8.ResultsSingle‐echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast‐enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single‐echo Dixon work.ConclusionTime‐resolved contrast‐enhanced MRI with single‐echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time‐subtraction methods.
Diagnostic accuracy of a clinical carotid plaque MR protocol using a neurovascular coil compared to a surface coil protocol
Brinjikji, Waleed , DeMarco, J. Kevin , Shih, Robert , Hilditch, Christopher Alan , Nicholson, Patrick , Shih, Robert Y , Lanzino, Giuseppe , Rabinstein, Alejandro A. , Huston, John

Journal of Magnetic Resonance Imaging | February 26, 2018 | Volume: 48 | Issue: 5 | Pages: 1264-1272

10.1002/jmri.25984 | PMID 29479763 Get It

BackgroundCarotid plaque imaging with MRI is becoming more commonplace, but practical challenges exist in performing plaque imaging with surface coils.PurposeTo compare the diagnostic performance of a carotid plaque MRI protocol using a standard neurovascular coil (Neurovascular Coil Protocol) to a higher‐resolution carotid plaque MRI using carotid surface coils (Surface Coil Protocol) in characterizing carotid plaque.Study TypeProspective study comparing two MR techniques in plaque characterization.PopulationThirty‐eight consecutive carotid artery disease patients.Field Strength/SequencePatients underwent 3T MRI using 1) a Neurovascular Coil Protocol including the following sequences: 3D‐FSE T1 pre/postcontrast and precontrast 3D IR‐FSPGR, and 2) a Surface Coil Protocol using standard multicontrast MRI sequences.AssessmentPlaque characteristics analyzed by two independent neuroradiologists included intraplaque hemorrhage (IPH), lipid‐rich necrotic‐core (LRNC), and thin/ruptured fibrous cap (TRFC).Statistical TestsDiagnostic performance of the Neurovascular Coil Protocol was compared to the Surface Coil Protocol reference standard using receiver‐operating curves.ResultsFor IPH, sensitivity, specificity, and area under the curve (AUC) of the Neurovascular Coil Protocol were 91.1% (95% confidence interval [CI] = 78.8–97.5%), 87.0% (95% CI = 66.4–97.2%), and 0.92, respectively. For LRNC without IPH sensitivity, specificity, and AUC were 73.3% (95% CI = 44.9–92.2%), 85.7% (95% CI = 67.3–96.0%), and 0.84, respectively. For TRFC, sensitivity, specificity, and AUC were 35.3% (95% CI = 14.2–61.7%), 97.6% (95% CI = 87.4–99.9%), and 0.66 respectively. Interobserver agreement for IPH, LRNC, and TRFC using the Neurovascular Coil Protocol were k = 0.87 (95% CI = 0.75–0.99), k = 0.54 (95% CI = 0.29–0.80), and k = 0.41 (95% CI = 0.08–0.74), respectively.Data ConclusionOur Neurovascular Coil Protocol has high sensitivity, specificity, and accuracy in identifying IPH and LRNC but is limited in assessment of TRFC.Level of Evidence: 1Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2018;47:1264–1272.
Primary central nervous system vasculitis associated with lymphoma
Brown, Robert D. , Christianson, Teresa J., Ansell, Stephen M. , Hunder, Gene G. , Christianson, Teresa J H, Salvarani, Carlo , Huston, John , Giannini, Caterina

Neurology | February 13, 2018 | Volume: 90 | Issue: 10 | Pages: No page available

10.1212/wnl.0000000000005062 | PMID 29429967 Get It

Artificial neural networks for stiffness estimation in magnetic resonance elastography
Murphy, Matthew C. , Trzasko, Joshua D. , Glaser, Kevin J. , Manduca, Armando , Huston, John , Ehman, Richard L.

Magnetic Resonance in Medicine | November 29, 2017 | Volume: 80 | Issue: 1 | Pages: 351-360

10.1002/mrm.27019 | PMID 29193306 Get It

PurposeTo investigate the feasibility of using artificial neural networks to estimate stiffness from MR elastography (MRE) data.MethodsArtificial neural networks were fit using model‐based training patterns to estimate stiffness from images of displacement using a patch size of ∼1 cm in each dimension. These neural network inversions (NNIs) were then evaluated in a set of simulation experiments designed to investigate the effects of wave interference and noise on NNI accuracy. NNI was also tested in vivo, comparing NNI results against currently used methods.ResultsIn 4 simulation experiments, NNI performed as well or better than direct inversion (DI) for predicting the known stiffness of the data. Summary NNI results were also shown to be significantly correlated with DI results in the liver (R2 = 0.974) and in the brain (R2 = 0.915), and also correlated with established biological effects including fibrosis stage in the liver and age in the brain. Finally, repeatability error was lower in the brain using NNI compared to DI, and voxel‐wise modeling using NNI stiffness maps detected larger effects than using DI maps with similar levels of smoothing.ConclusionArtificial neural networks represent a new approach to inversion of MRE data. Summary results from NNI and DI are highly correlated and both are capable of detecting biologically relevant signals. Preliminary evidence suggests that NNI stiffness estimates may be more resistant to noise than an algebraic DI approach. Taken together, these results merit future investigation into NNIs to improve the estimation of stiffness in small regions. Magn Reson Med 80:351–360, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Reduced acoustic noise in diffusion tensor imaging on a compact MRI system
Tan, Ek T. , Hardy, Christopher J., Shu, Yunhong , In, Myung‐Ho , Guidon, Arnaud , Bernstein, Matt A. , Foo, Thomas , Bernstein, Matt A , Foo, Thomas K F , Tan, Ek T , Huston, John , In, Myung-Ho

Magnetic Resonance in Medicine | October 3, 2017 | Volume: 79 | Issue: 6 | Pages: 2902-2911

10.1002/mrm.26949 | PMID 28971512 Get It

PurposeTo investigate the feasibility of substantially reducing acoustic noise while performing diffusion tensor imaging (DTI) on a compact 3T (C3T) MRI scanner equipped with a 42‐cm inner‐diameter asymmetric gradient.MethodsA‐weighted acoustic measurements were made using 10 mT/m‐amplitude sinusoidal waveforms, corresponding to echo‐planar imaging (EPI) echo spacing of 0.25 to 5.0 ms, on a conventional, whole‐body 3T MRI and on the C3T. Acoustic measurements of DTI with trapezoidal EPI waveforms were then made at peak gradient performance on the C3T (80 mT/m amplitude, 700 T/m/s slew rate) and at derated performance (33 mT/m, 10 to 50 T/m/s) for acoustic noise reduction. DTI was acquired in two different phantoms and in seven human subjects, with and without gradient‐derating corresponding to multi‐ and single‐shot acquisitions, respectively.ResultsSinusoidal waveforms on the C3T were quieter by 8.5 to 15.6 A‐weighted decibels (dBA) on average as compared to the whole‐body MRI. The derated multishot DTI acquisition noise level was only 8.7 dBA (at 13 T/m/s slew rate) above ambient, and was quieter than non‐derated, single‐shot DTI by 22.3 dBA; however, the scan time was almost quadrupled. Although derating resulted in negligible diffusivity differences in the phantoms, small biases in diffusivity measurements were observed in human subjects (apparent diffusion coefficient = +9.3 ± 8.8%, fractional anisotropy = +3.2 ± 11.2%, radial diffusivity = +9.4 ± 16.8%, parallel diffusivity = +10.3 ± 8.4%).ConclusionThe feasibility of achieving reduced acoustic noise levels with whole‐brain DTI on the C3T MRI was demonstrated. Magn Reson Med 79:2902–2911, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Change in Anterior Cruciate Ligament Graft Choice and Outcomes Over Time
Kaeding, Christopher C. , Pedroza, Angela , Reinke, Emily K. , Huston, Laura J. , Hewett, Timothy E. , Flanigan, David C. , Group, MOON Knee, Brophy, Robert H. , Wolf, Brian R. , Jones, Morgan H. , McCarty, Eric C. , Brophy, Robert H. , Jones, Morgan H , Group, MOON knee, Spindler, Kurt P , McCarty, Eric C

Arthroscopy | August 26, 2017 | Volume: 33 | Issue: 11 | Pages: 2007-2014

10.1016/j.arthro.2017.06.019 | PMID 28847572 Get It

Purpose To analyze failure rate in 2‐year increments to determine if graft choice changed over time and graft failure rate. Methods A prospective 2002‐2008 database was used to identify risk factors for anterior cruciate ligament (ACL) retear. Subjects who had primary ACL retear with no history of contralateral surgery and 2‐year follow‐up were included. Subjects who underwent a multiligament reconstruction were excluded. Graft type, age, sex, smoking status, body mass index, Marx activity level at index surgery, medial and lateral meniscus status at time of ACL retear, sport played after ACL reconstruction, and clinical site were evaluated. Analysis was repeated using 2002‐2003 (early) and 2007‐2008 (late) 2‐year databases. Analysis of variance with post hoc analysis was performed to detect significant differences in age and Marx score by graft type over time. Results Two‐year follow‐up for graft failure was obtained on 2,497 of 2,692 (93%) subjects. There were 112 of 2,497 (4.5%) ACL retears identified at 2‐year follow‐up. The only predictor that changed between early/late periods was allograft use. Allograft odds ratio decreased from 13.1 to 9.5 ( P < .01). Allografts were used in older patients (31‐40 years) and with lower Marx scores (10‐8) from early to late periods. The mean age of subjects who received bone–patellar tendon–bone autografts did not significantly change over time (22.8‐23.5). The mean age of subjects who received hamstring autografts fell (27.9‐25.5). The mean age of subjects who received allografts rose significantly (31.3‐39.8, P < .01). The mean Marx score of subjects who received bone–patellar tendon–bone and hamstring autografts did not significantly change over time. The mean Marx score of subjects who received allografts decreased significantly ( P < .01). Conclusions After early recognition, allograft use in young active patients was a risk factor for retear; graft choice by surgeons changed in the late period to use of allografts in older and less‐active patients, which correlated with a significant decrease in retear risk. Level of Evidence Level III, case control study.