Abstract BACKGROUND Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm ( P = .002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract
Accuracy of detecting enlargement of aneurysms using different MRI modalities and measurement protocols
OBJECTIVEAneurysm growth is considered predictive of future rupture of intracranial aneurysms. However, how accurately neuroradiologists can reliably detect incremental aneurysm growth using clinical MRI is still unknown. The purpose of this study was to assess the agreement rate of detecting aneurysm enlargement employing generally used MRI modalities.METHODSThree silicone flow phantom models, each with 8 aneurysms of various sizes at different sites, were used in this study. The aneurysm models were identical except for an incremental increase in the sizes of the 8 aneurysms, which ranged from 0.4 mm to 2 mm. The phantoms were imaged on 1.5-T and 3-T MRI units with both time-of-flight (TOF) and contrast-enhanced MR angiography. Three independent expert neuroradiologists measured the aneurysms in a blinded manner using different measurement approaches. The individual and agreement detection rates of aneurysm enlargement among the 3 experts were calculated.RESULTSThe mean detection rate of any increase in any aneurysmal dimension was 95.7%. The detection rates of the 3 observers (observers A, B, and C) were 98.0%, 96.6%, and 92.7%, respectively (p = 0.22). The detection rates of each MRI modality were 91.3% using 1.5-T TOF, 97.2% using 1.5-T with Gd, 95.8% using 3.0-T TOF, and 97.2% using 3.0-T with Gd (p = 0.31). On the other hand, the mean detection rate for aneurysm enlargement was 54.8%. Specifically, the detection rates of observers A, B, and C were 49.0%, 46.1%, and 66.7%, respectively (p = 0.009). As the incremental enlargement value increased, the detection rate for aneurysm enlargement increased. The use of 1.5-T Gd improved the detection rate for small incremental enlargement (e.g., 0.4–1 mm) of the aneurysm (p = 0.04). The location of the aneurysm also affected the detection rate for aneurysm enlargement (p < 0.0001).CONCLUSIONSThe detection rate and interobserver agreement were very high for aneurysm enlargement of 0.4–2 mm. The detection rate for at least 1 increase in any aneurysm dimension did not depend on the choice of MRI modality or measurement protocol. Use of Gd improved the accuracy of measurement. Aneurysm location may influence the accuracy of detecting enlargement.
Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial
Abstract BACKGROUND: Early and mid-term safety and efficacy of aneurysm treatment with the Pipeline Embolization Device (PED) has been well demonstrated in prior studies. OBJECTIVE: To present 5-yr follow-up for patients treated in the Pipeline for Uncoilable or Failed Aneurysms clinical trial. METHODS: In our prospective, multicenter trial, 109 complex internal carotid artery (ICA) aneurysms in 107 subjects were treated with the PED. Patients were followed per a standardized protocol at 180 d and 1, 3, and 5 yr. Aneurysm occlusion, in-stent stenosis, modified Rankin Scale scores, and complications were recorded. RESULTS: The primary endpoint of complete aneurysm occlusion at 180 d (73.6%) was previously reported. Aneurysm occlusion for those patients with angiographic follow-up progressively increased over time to 86.8% (79/91), 93.4% (71/76), and 95.2% (60/63) at 1, 3, and 5 yr, respectively. Six aneurysms (5.7%) were retreated. New serious device-related events at 1, 3, and 5 yr were noted in 1% (1/96), 3.5% (3/85), and 0% (0/81) of subjects. There were 4 (3.7%) reported deaths in our trial. Seventy-eight (96.3%) of 81 patients with 5-yr clinical follow-up had modified Rankin Scale scores ≤2. No delayed neurological deaths or hemorrhagic or ischemic cerebrovascular events were reported beyond 6 mo. No recanalization of a previously occluded aneurysm was observed. CONCLUSION: Our 5-yr findings demonstrate that PED is a safe and effective treatment for large and giant wide-necked aneurysms of the intracranial ICA, with high rates of complete occlusion and low rates of delayed adverse events.
GEL THE NEC: a prospective registry evaluating the safety, ease of use, and efficacy of the HydroSoft coil as a finishing device
Background and purpose The HydroSoft coil was developed as a finishing coil, ideally to be placed along the aneurysm neck to enhance intracranial aneurysm healing. The GEL THE NEC (Gaining Efficacy Long Term: Hydrosoft, an Emerging, New, Embolic Coil) multicenter registry was developed to assess the safety and efficacy of HydroSoft coils in treating intracranial aneurysms. We report angiographic and clinical results of this prospective registry. Materials and methods GEL THE NEC was performed at 27 centers in five countries. Patients aged 21–90 years with a ruptured or unruptured aneurysm 3–15 mm in size were eligible for enrollment. The following variables were obtained: demographics/comorbidities, aneurysm geometry, adjunctive devices used, proportion of patients in whom HydroSoft coils were successfully placed, and long-term angiographic outcomes (graded by an independent core laboratory using the Modified Raymond Scale), and procedure-related adverse events. Predictors of good angiographic outcome were studied using χ2 and t-tests. Results A total of 599 patients with 599 aneurysms were included in this study. HydroSoft coils were successfully deployed in 577 (96.4%) patients. Procedure-related major morbidity and mortality were 0.5% (3/599) and 1.3% (8/599), respectively. The most common perioperative complications were iatrogenic vasospasm (30/599, 5.0%), thromboemboli (27/599, 4.5%), and aneurysm perforation (16/599, 2.7%). At last angiographic follow-up (mean 9.0±6.3 months), the complete occlusion rate was 63.2% (280/442) and near complete occlusion rate was 25.2% (107/442). The core laboratory read recanalization rate was 10.8% (46/425) and the retreatment rate was 3.4% (20/599). Conclusions Endovascular treatment of intracranial aneurysms with HydroSoft coils resulted in complete/near complete occlusion rates of 88% and a major complication rate of 1.8%. Trial registration number NCT01000675.
Pipeline for uncoilable or failed aneurysms: 3-year follow-up results
OBJECTIVEThe long-term effectiveness of endovascular treatment of large and giant wide-neck aneurysms using traditional endovascular techniques has been disappointing, with high recanalization and re-treatment rates. Flow diversion with the Pipeline Embolization Device (PED) has been recently used as a stand-alone therapy for complex aneurysms, showing significant improvement in effectiveness while demonstrating a similar safety profile to stent-supported coil treatment. However, relatively little is known about its long-term safety and effectiveness. Here the authors report on the 3-year safety and effectiveness of flow diversion with the PED in a prospective cohort of patients with large and giant internal carotid artery aneurysms enrolled in the Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial.METHODSThe PUFS trial is a prospective study of 107 patients with 109 aneurysms treated with the PED. Primary effectiveness and safety end points were demonstrated based on independently monitored 180-day clinical and angiographic data. Patients were enrolled in a long-term follow-up protocol including 1-, 3-, and 5-year clinical and imaging follow-up. In this paper, the authors report the midstudy (3-year) effectiveness and safety data.RESULTSAt 3 years posttreatment, 74 subjects with 76 aneurysms underwent catheter angiography as required per protocol. Overall, complete angiographic aneurysm occlusion was observed in 71 of these 76 aneurysms (93.4% cure rate). Five aneurysms were re-treated, using either coils or additional PEDs, for failure to occlude, and 3 of these 5 were cured by the 3-year follow-up. Angiographic cure with one or two treatments of Pipeline embolization alone was therefore achieved in 92.1%. No recanalization of a previously completely occluded aneurysm was noted on the 3-year angiograms. There were 3 (2.6%) delayed device- or aneurysm-related serious adverse events, none of which led to permanent neurological sequelae. No major or minor late-onset hemorrhagic or ischemic cerebrovascular events or neurological deaths were observed in the 6-month through 3-year posttreatment period. Among 103 surviving patients, 85 underwent functional outcome assessment in which modified Rankin Scale scores of 0–1 were demonstrated in 80 subjects.CONCLUSIONSPipeline embolization is safe and effective in the treatment of complex large and giant aneurysms of the intracranial internal carotid artery. Unlike more traditional endovascular treatments, flow diversion results in progressive vascular remodeling that leads to complete aneurysm obliteration over longer-term follow-up without delayed aneurysm recanalization and/or growth.Clinical trial registration no.: NCT00777088 (clinicaltrials.gov)
Neuroophthalmological outcomes associated with use of the Pipeline Embolization Device: analysis of the PUFS trial results
OBJECT Neuroophthalmological morbidity is commonly associated with large and giant cavernous and supraclinoid internal carotid artery (ICA) aneurysms. The authors sought to evaluate the neuroophthalmological outcomes after treatment of these aneurysms with the Pipeline Embolization Device (PED). METHODS The Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial was an international, multicenter prospective trial evaluating the safety and efficacy of the PED. All patients underwent complete neuroophthalmological examinations both before the PED procedure and at a 6-month follow-up. All examinations were performed for the purpose of this study and according to study criteria. RESULTS In total, 108 patients were treated in the PUFS trial, 98 of whom had complete neuroophthalmological follow-up. Of the patients with complete follow-up, 39 (40%) presented with a neuroophthalmological baseline deficit that was presumed to be attributable to the aneurysm, and patients with these baseline deficits had significantly larger aneurysms. In 25 of these patients (64%), the baseline deficit showed at least some improvement 6 months after PED treatment, whereas in 1 patient (2.6%), the deficits only worsened. In 5 patients (5%), new deficits had developed at the 6-month follow-up, while in another 6 patients (6%), deficits that were not originally assumed to be related to the aneurysm had improved by that time. A history of diabetes was associated with failure of the baseline deficits to improve after the treatment. The aneurysm maximum diameter was significantly larger in patients with a new deficit or a worse baseline deficit at 6 months postprocedure. CONCLUSIONS Patients treated with the PED for large and giant ICA aneurysms had excellent neuroophthalmological outcomes 6 months after the procedure, with deficits improving in most of the patients, very few deficits worsening, and few new deficits developing.
O-009 Safety of flow diversion: Results from a multicentre registry
Purpose To determine the rates of neurologic adverse events following Pipeline Embolic Device (PED) placement for intracranial aneurysm treatment. Methods A retrospective review of medical records was performed at 19 centres to identify consecutive intracranial aneurysms treated with the PED following regulatory approval for marketing the device in the given country. All patients in whom at least one PED was placed and in whom follow-up was available prior to IRB or ethics panel approval were enrolled. Three anatomic/size subgroups were defined, including 1) pre-PComm, internal carotid artery aneurysms 10mm or greater (“large ICA”), 2) ICA aneurysms >10mm and/or at/distal to the PComm region (“other anterior circulation”), and 3) posterior circulation aneurysms. “Primary safety events” included stroke, haemorrhage, parent artery stenosis, permanent cranial neuropathy, and spontaneous rupture of the target aneurysm. Severe safety events were defined as any event causing significant impairment of functioning causing the inability of the subject to carry out usual activities. Statistical analysis was performed using standard summary statistics; p-values comparing subgroups were computed using Pearson's chi-square test for discrete variables and analysis of variance for continuous variables. Results To date, 580 aneurysms, including 183 large ICA, 344 other anterior circulation, and 53 posterior circulation aneurysms have been treated and followed for a mean duration of 7.8 months (SD 7.3, range 0.1 - 40.8). 437 (76%) of 580 aneurysms were saccular and 80 (14%) were fusiform; 32 (5.5%) were classified as giant (<25mm diameter). 549 (93%) were unruptured. 241 (42%) were treated with multiple PEDs. Primary safety events were noted in 62 (12%) cases. Severe neurological events occurred in 35 (6.8%) cases, and occurred more frequently in posterior circulation aneurysms (7 (13%)) than in either large ICA or other anterior circulation aneurysms (15 (8.8%) and (13 (4.5%), respectively, p=.035). Major stroke occurred in 20 (3.9%) of 515 subjects (4.1%, 3.1%, and 7.5% in large ICA, other anterior circulation, and posterior circulation aneurysms, respectively, p=.31). Ipsilateral intracranial haemorrhage occurred in 12 (2.3%) subjects (3.5%, 1.7%, and 1.9% in large ICA, other anterior circulation, and posterior circulation aneurysms, respectively, p=.47). Spontaneous aneurysm rupture occurred in 3 (0.6%) aneurysms, all of which were giant, resulting in a 9% incidence of rupture in giant aneurysms. Mortality rate was 4.3% and was significantly higher for posterior circulation aneurysms (11.3%) as compared to anterior circulation aneurysms (3.5%, p=.019). Conclusions Preliminary data indicates that in approximately 7% of aneurysms treated with PED, substantial neurologic complications occurred, with rates of both severe neurologic events and mortality occurring significantly higher in the posterior as compared to the anterior circulation. Both ipsilateral haemorrhage and spontaneous aneurysm rupture were rare, with the latter event limited to giant aneurysms. Disclosures D. Kallmes: 1; C; MicroVention, Sequent, Benvenue, eV3. 2; C; General Electric, Codman, eV3. E. Boccardi: None. A. Bonafe: None. S. Cekirge: None. D. Fiorella: 2; C; Pipeline proctor, consultant, (<10K, EV3). R. Hanel: None. P. Jabbour: None. E. Levy: None. D. Lopes: 6; C; Receives compensation for training & proctoring for Pipeline devices. P. Lylyk: None. C. McDougall: None. A. Siddiqui: None. I. Szikora: None. H. Woo: None.